Unchanged field: ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ FP cavity modal analysis using cold optics parameters ROC(ITM) = 1934, ROC(ETM) = 2245, Cavity lenggth = 3994.499999672, total Gouy = 2.7169491305278 Fval(ITM) = -4297.7777755379, OPL(ITM) = 0.13793083662307, Fval(ETM) = -4988.8888885557 waist size = 0.01203704073212, waist position from ITM = 1834.2198819617, Rayleigh range = 427.80682127602 Mode parameters of cavity fields ETM AR (out base) : w = 0.0619634 R = 1548.276 z = 1519.925 z0 = 207.583 w0 = 0.008384783 (out fit ) : w = 0.06195473 R = 1548.354 (x0,y0)=( 0 , 0 ) power / HMfrac = 0.001417401 / 5.11e-07 ETM HR (in base) : w = 0.0619634 R = 2245 z = 2160.28 z0 = 427.8068 w0 = 0.01203704 (in fit ) : w = 0.06195473 R = 2245.165 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4804 / 3.565e-07 (out fit ) : w = 0.06195473 R = -2244.835 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4788 / 5.11e-07 ITM HR (in base) : w = 0.05299391 R = 1934 z = 1834.22 z0 = 427.8068 w0 = 0.01203704 (in fit ) : w = 0.05300038 R = 1933.926 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4788 / 5.11e-07 (out fit ) : w = 0.05299988 R = -1934.073 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4804 / 3.565e-07 ITM AR (in base) : w = 0.05299391 R = -1333.793 z = -1300.153 z0 = 209.1332 w0 = 0.008416031 (in fit ) : w = 0.05299391 R = -1333.793 (x0,y0)=( 0 , 0 ) power / HMfrac = 1 / 9.392e-14 (out fit ) : w = 0.05300681 R = 1333.723 (x0,y0)=( 0 , 0 ) power / HMfrac = 0.9983715 / 1.453e-06 -------------------------------------------------------------------------------------------------------------- +++ Field "fromITM" +++ Amplitude = ( Re, Im ) [ subPower, fraction ] only those modes are listed whose powers > 1e-06 of the total power HG( 0 , 0 ) = ( 16.836926640666, 1.3650949721178e-06 ) [ 283.48209870319, 0.99999964143443 ] Total power = 283.48220035014 Tabulated Power fraction = 0.99999964143443 Low power mode fraction = 1.2799053118676e-08 Higher order mode fraction = 3.4576652174767e-07 Modified ROC++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ FP cavity modal analysis using cold optics parameters ROC(ITM) = 1934, ROC(ETM) = 2228.49, Cavity lenggth = 3994.499999672, total Gouy = 2.7359777032173 Fval(ITM) = -4297.7777755379, OPL(ITM) = 0.13793083662307, Fval(ETM) = -4952.199994359 waist size = 0.011760407204314, waist position from ITM = 1843.5407055726, Rayleigh range = 408.36918526538 Mode parameters of cavity fields ETM AR (out base) : w = 0.06305083 R = 1536.89 z = 1510.986 z0 = 197.8396 w0 = 0.008185636 (out fit ) : w = 0.0630373 R = 1536.934 (x0,y0)=( 0 , 0 ) power / HMfrac = 0.001417398 / 1.043e-06 ETM HR (in base) : w = 0.06305083 R = 2228.49 z = 2150.959 z0 = 408.3692 w0 = 0.01176041 (in fit ) : w = 0.0630373 R = 2228.583 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4798 / 8.095e-07 (out fit ) : w = 0.0630373 R = -2228.397 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4782 / 1.043e-06 ITM HR (in base) : w = 0.0543781 R = 1934 z = 1843.541 z0 = 408.3692 w0 = 0.01176041 (in fit ) : w = 0.0543891 R = 1933.937 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4782 / 1.043e-06 (out fit ) : w = 0.05438902 R = -1934.069 (x0,y0)=( 0 , 0 ) power / HMfrac = 283.4798 / 8.095e-07 ITM AR (in base) : w = 0.0543781 R = -1333.793 z = -1303.375 z0 = 199.1139 w0 = 0.008211957 (in fit ) : w = 0.0543781 R = -1333.793 (x0,y0)=( 0 , 0 ) power / HMfrac = 1 / 9.814e-14 (out fit ) : w = 0.05440004 R = 1333.733 (x0,y0)=( 0 , 0 ) power / HMfrac = 0.9983681 / 3.268e-06 -------------------------------------------------------------------------------------------------------------- +++ Field "fromITM" +++ Amplitude = ( Re, Im ) [ subPower, fraction ] only those modes are listed whose powers > 1e-06 of the total power HG( 0 , 0 ) = ( 16.836851139551, -0.00020989334660248 ) [ 283.47955633945, 0.99999919053137 ] Total power = 283.47978580744 Tabulated Power fraction = 0.99999919053137 Low power mode fraction = 8.2032544870322e-09 Higher order mode fraction = 8.0126537127523e-07 Added on HR Phase ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ FP cavity modal analysis using cold optics parameters ROC(ITM) = 1934, ROC(ETM) = 2245, Cavity lenggth = 3994.499999672, total Gouy = 2.7169491305288 Fval(ITM) = -4270.969192163, OPL(ITM) = 0.13793083662307, Fval(ETM) = -4988.8888885557 waist size = 0.012037040732107, waist position from ITM = 1834.2198819622, Rayleigh range = 427.80682127506 Mode parameters of cavity fields ETM AR (out base) : w = 0.0619634 R = 1548.276 z = 1519.925 z0 = 207.583 w0 = 0.008384783 (out fit ) : (wX,wY)=(0.063172, 0.063169) R(x/y) = ( 1548.33 , 1548.386) (x0,y0)=(-6.462e-06 , -1.403e-06 ) power / HMfrac = 0.00141645 / 0.0003833 ETM HR (in base) : w = 0.0619634 R = 2245 z = 2160.28 z0 = 427.8068 w0 = 0.01203704 (in fit ) : (wX,wY)=(0.063172, 0.063169) R(x/y) = ( 2245.113, 2245.231) (x0,y0)=(-6.462e-06 , -1.403e-06 ) power / HMfrac = 283.2902 / 0.0003835 (out fit ) : (wX,wY)=(0.063172, 0.063169) R(x/y) = (-2244.887, -2244.769) (x0,y0)=( 6.462e-06 , -1.403e-06 ) power / HMfrac = 283.2886 / 0.0003833 ITM HR (in base) : w = 0.05299391 R = 1934 z = 1834.22 z0 = 427.8068 w0 = 0.01203704 (in fit ) : (wX,wY)=(0.053713, 0.053704) R(x/y) = ( 1921.172, 1921.127) (x0,y0)=(-5.704e-06 , -7.536e-08 ) power / HMfrac = 283.2886 / 0.0003833 (out fit ) : (wX,wY)=(0.053709, 0.053699) R(x/y) = (-1921.16 , -1921.227) (x0,y0)=( 5.507e-06 , -1.27e-07 ) power / HMfrac = 283.2902 / 0.0003835 ITM AR (in base) : w = 0.05299391 R = -1333.793 z = -1300.153 z0 = 209.1332 w0 = 0.008416031 (in fit ) : w = 0.05299391 R = -1333.793 (x0,y0)=( 0 , 0 ) power / HMfrac = 1 / 1.02e-13 (out fit ) : (wX,wY)=(0.054484, 0.054465) R(x/y) = ( 1333.299, 1333.247) (x0,y0)=(-1.125e-05 , 2.802e-08 ) power / HMfrac = 0.9982727 / 0.000739 -------------------------------------------------------------------------------------------------------------- +++ Field "fromITM" +++ Amplitude = ( Re, Im ) [ subPower, fraction ] only those modes are listed whose powers > 1e-06 of the total power HG( 0 , 0 ) = ( 16.823233328289, -3.3347981121967e-07 ) [ 283.02117961806, 0.99926952963977 ] HG( 2 , 0 ) = ( 0.3218538817865, 0.0011120308394485 ) [ 0.10359115783363, 0.00036575173526922 ] HG( 0 , 2 ) = ( 0.32025942436321, 0.0011157068532504 ) [ 0.10256734369524, 0.00036213693063203 ] Total power = 283.22806932789 Tabulated Power fraction = 0.99999741830567 Low power mode fraction = 6.6941152371119e-07 Higher order mode fraction = 1.9122828043283e-06 HR Phase (10%) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ FP cavity modal analysis using cold optics parameters ROC(ITM) = 1934, ROC(ETM) = 2245, Cavity lenggth = 3994.499999672, total Gouy = 2.7169491305288 Fval(ITM) = -4297.7777755379, OPL(ITM) = 0.13793083662307, Fval(ETM) = -4952.8015394783 waist size = 0.012037040732107, waist position from ITM = 1834.2198819622, Rayleigh range = 427.80682127506 Mode parameters of cavity fields ETM AR (out base) : w = 0.0619634 R = 1548.276 z = 1519.925 z0 = 207.583 w0 = 0.008384783 (out fit ) : (wX,wY)=(0.063095, 0.063087) R(x/y) = ( 1536.446, 1536.449) (x0,y0)=(-5.048e-06 , 7.605e-07 ) power / HMfrac = 0.001416324 / 0.001161 ETM HR (in base) : w = 0.0619634 R = 2245 z = 2160.28 z0 = 427.8068 w0 = 0.01203704 (in fit ) : (wX,wY)=(0.063095, 0.063087) R(x/y) = ( 2227.926, 2227.932) (x0,y0)=(-5.048e-06 , 7.605e-07 ) power / HMfrac = 283.265 / 0.0007261 (out fit ) : (wX,wY)=(0.063095, 0.063087) R(x/y) = (-2227.412, -2227.408) (x0,y0)=( 5.048e-06 , 7.606e-07 ) power / HMfrac = 283.2634 / 0.0007368 ITM HR (in base) : w = 0.05299391 R = 1934 z = 1834.22 z0 = 427.8068 w0 = 0.01203704 (in fit ) : (wX,wY)=( 0.05446, 0.05446) R(x/y) = ( 1933.954, 1934.054) (x0,y0)=(-3.914e-06 , -1.471e-06 ) power / HMfrac = 283.2634 / 0.0007368 (out fit ) : (wX,wY)=(0.054449, 0.05445) R(x/y) = (-1934.045, -1933.947) (x0,y0)=( 3.665e-06 , -1.431e-06 ) power / HMfrac = 283.265 / 0.0007261 ITM AR (in base) : w = 0.05299391 R = -1333.793 z = -1300.153 z0 = 209.1332 w0 = 0.008416031 (in fit ) : w = 0.05299391 R = -1333.793 (x0,y0)=( 0 , 0 ) power / HMfrac = 1 / 1.081e-13 (out fit ) : (wX,wY)=(0.055943, 0.055939) R(x/y) = ( 1333.785, 1333.859) (x0,y0)=(-7.397e-06 , -3.43e-07 ) power / HMfrac = 0.9983147 / 0.002925 -------------------------------------------------------------------------------------------------------------- Amplitude = ( Re, Im ) [ subPower, fraction ] only those modes are listed whose powers > 1e-06 of the total power HG( 0 , 0 ) = ( 16.824366631994, 9.3506166250062e-07 ) [ 283.05931256777, 0.99927386396804 ] HG( 2 , 0 ) = ( 0.32071751149464, 0.001108454578718 ) [ 0.10286095085087, 0.00036312622565125 ] HG( 0 , 2 ) = ( 0.31999451038744, 0.0011083966062525 ) [ 0.10239771522113, 0.00036149088197203 ] Total power = 283.26500149195 Tabulated Power fraction = 0.99999848107566 Low power mode fraction = 5.3523730785232e-07 Higher order mode fraction = 9.83687030498e-07