40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  SUS Lab eLog, Page 2 of 29  Not logged in ELOG logo
Entry  Tue Jan 21 16:13:03 2020, Duo, DailyProgress, , Distortion of noisemon IMG_1658.PNGIMG_1659.PNGupconv.pdfupconv5Hz.pdfupconvLinear.pdf
    Reply  Tue Jan 28 08:46:13 2020, rana, DailyProgress, Electronics, Distortion of noisemon 
Entry  Tue Jan 14 17:07:49 2020, Duo, DailyProgress, , Testing another two boards 
Entry  Mon Jan 13 16:48:52 2020, Duo, DailyProgress, , Noisemon updates 
Entry  Thu Dec 12 16:48:39 2019, Duo, DailyProgress, , Modifying the board changes the transfer function ModifiedVsIntact.pdfModifedVsIntact.xml.gzgainDiff.pdflisocomparison.pdf
Entry  Mon Dec 9 22:06:19 2019, Duo, DailyProgress, , Two boards tested 
Entry  Wed Dec 4 19:00:37 2019, Noisemon board modified, DailyProgress, , Noisemon board modifications 
    Reply  Thu Dec 5 12:37:58 2019, Noisemon board modified, DailyProgress, , Noisemon board modifications ModificationComparison.pdf
       Reply  Thu Dec 5 20:42:55 2019, Duo, DailyProgress, Electronics, Noisemon board modifications NoDrive.pdf10HzSine.pdfTF.pdf
Entry  Tue Dec 3 09:50:18 2019, Duo, DailyProgress, , Interesting observation on noisemon debugging Saturating.pdfdiaggui.pdfGoodagain.pdf
Entry  Mon Dec 2 15:28:03 2019, Duo, Misc, , S1900296 board damaged 
Entry  Wed Nov 27 23:45:29 2019, Duo, DailyProgress, , Noisemon Debug Progress saturating.pdfAfterRestart.pdf
Entry  Mon Nov 25 16:43:50 2019, Duo, DailyProgress, , Time domain projection is consistent with LLO data (except LL channel, which saturates) timeresponse.pdf49892_20191113153034_ITMY_NoiseMon.pngdrive.pdfarchive.tar.gz
Entry  Thu Nov 14 17:14:32 2019, Duo, DailyProgress, , Noisemon problem observation Screenshot_from_2019-11-14_17-13-46.pngts.xmlScreenshot_from_2019-11-14_17-26-55.png
Entry  Thu Nov 14 15:54:57 2019, Duo, DailyProgress, , Issue consistency among ETMY, ITMX and ITMY Screenshot_from_2019-11-14_15-54-27.pngScreenshot_from_2019-11-14_15-51-25.pngScreenshot_from_2019-11-14_15-51-15.png
Entry  Thu Nov 14 15:04:25 2019, Duo, DailyProgress, , ETMY check Screenshot_from_2019-11-14_15-02-05.pngScreenshot_from_2019-11-14_15-08-42.pngScreenshot_from_2019-11-14_15-15-56.pngScreenshot_from_2019-11-14_15-30-07.png
Entry  Mon Nov 11 20:35:13 2019, Duo, DailyProgress, , First sign of ITMY LL noisemon saturation Screenshot_from_2019-11-11_20-33-46.png
Entry  Fri Nov 8 13:32:15 2019, Duo, DailyProgress, , Noisemon and FastIMON at L1 6x
Entry  Wed Oct 23 20:37:53 2019, Duo, DailyProgress, , Nosiemon check Screenshot_from_2019-10-23_20-48-13.png
Entry  Tue Oct 8 17:31:27 2019, Duo, Summary, , Noisemon check  6x
Entry  Wed Oct 2 13:50:03 2019, Duo, DailyProgress, , ITMY noisemon 9x
Entry  Fri Aug 30 13:15:07 2019, Duo, Summary, Electronics, ITMX DAC noise plot.pdfDesktop.zipprojected.pdfArchive.zip
    Reply  Sat Aug 31 19:21:13 2019, rana, Summary, Electronics, ITMX DAC noise 
       Reply  Wed Sep 11 17:24:43 2019, Duo, Summary, Electronics, ITMX DAC noise plot.pdfbeforeSub.pdf
Entry  Fri Aug 30 14:45:42 2019, rana, Computing, DAQ, Download data with pyNDS ChanList_darm.txtgetData.py
Entry  Wed Aug 28 13:39:29 2019, Duo, DailyProgress, , Changed bin size to 0.1Hz and got it plot.pdfDesktop.zip
    Reply  Wed Aug 28 16:15:51 2019, rana, DailyProgress, , Changed bin size to 0.1Hz and got it 
Entry  Wed Aug 28 13:20:01 2019, Duo, DailyProgress, , Window changed to BMH plot.pdf
Entry  Tue Aug 27 14:41:04 2019, Duo, DailyProgress, , Average 10 ETMY_Feb.xml
    Reply  Tue Aug 27 14:59:00 2019, Duo, DailyProgress, , Average 10 plot.pdfDesktop.zipplot.pdf
Entry  Mon Aug 26 15:13:41 2019, Duo, DailyProgress, , Noise vs number of avg Archive.zipplot_10.pdfplot_100.pdf
Entry  Mon Aug 26 14:57:47 2019, Duo, DailyProgress, , ETMY noise vs. ITMX noise plot.pdfArchive.zip
Entry  Fri Aug 23 15:22:59 2019, Duo, DailyProgress, , L1 noise and average l1_10.xmll1_50.xmll1_100.xmll1_500.xml
Entry  Fri Aug 23 15:11:36 2019, Duo, DailyProgress, , ETMY noisemon l1_ETMY_template.xmlScreenshot_from_2019-08-23_15-11-05.png
Entry  Thu Aug 22 18:13:19 2019, Duo, DailyProgress, , Noisemon Data from all four channels l1_template.xml
    Reply  Fri Aug 23 13:42:16 2019, Duo, DailyProgress, , Noisemon Data from all four channels plot.pdfArchive.zip
Entry  Tue Aug 20 18:15:11 2019, Duo, DailyProgress, , Noisemon data more avg plot.pdfArchive.zip
Entry  Tue Aug 20 10:31:12 2019, Duo, DailyProgress, , Noisemon test Archive.zipplot.pdf
Entry  Thu Aug 15 17:23:40 2019, Duo, DailyProgress, , L1 noisemon 1-coherence datScreenshot_from_2019-08-16_09-53-19.pngScreenshot_from_2019-08-16_09-52-44.pngScreenshot_from_2019-08-16_09-52-07.pngScreenshot_from_2019-08-16_09-51-24.png
Entry  Sat Aug 3 23:19:55 2019, Duo, Summary, Electronics, Op amp oscillation caused by capacitive loading and its fix osci.filosci.pdf
Entry  Fri Jul 12 13:45:39 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan 
    Reply  Thu Jul 18 11:50:43 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan noisetf
       Reply  Thu Jul 18 16:44:30 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan tf.pdftf.zip
          Reply  Fri Jul 19 23:55:19 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan noise.pdfnoise.zip
             Reply  Tue Jul 23 16:31:19 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan noise.zipnoise.pdf
    Reply  Tue Jul 23 18:44:34 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan tf
       Reply  Wed Jul 24 00:12:18 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan TransferFunction.pdftf.zipTransferFunction1.pdf
          Reply  Mon Jul 29 13:59:02 2019, Duo, Noise Hunting, Electronics, Noisemon board test plan DesktopScreenshot_from_2019-07-29_13-59-25.png
Entry  Wed Jul 17 13:35:02 2019, Duo, DailyProgress, , Unknown issue image1.jpegScreenshot_from_2019-07-17_13-34-29.png
Entry  Sat Jun 8 15:52:48 2019, Duo, Misc, , Arrival date of noisemon 
Entry  Wed Apr 17 16:34:37 2019, Duo, DailyProgress, , Noisemon update MonitorCircuit.SchDocMonitorBoard.SchDocMonitorBoard1.PcbDocnoisemon.pdf
Entry  Mon Apr 1 20:25:20 2019, Duo, DailyProgress, , Changes on noisemon being made noisemon.pdf
Entry  Tue Feb 19 18:11:43 2019, Duo, DailyProgress, , Tuesday report noisemon.pdf
Entry  Fri Feb 15 18:38:00 2019, rana, Noise Hunting, Electronics, NoiseMon nonlinearity? 
Entry  Tue Feb 5 20:55:34 2019, Duo, Summary, , Noisemon test results 6x
Entry  Sun Jan 20 16:00:37 2019, Duo, DailyProgress, , Update on the noisemon board TF_20-01-2019_155018_Spectrum.pdfTF_20-01-2019_155018.txtnoisespectrum_20-01-2019_150429_Spectrum.pdfnoisespectrum_20-01-2019_150429.txtTimeSeries.jpg
    Reply  Fri Feb 1 12:35:13 2019, not Duo, DailyProgress, , Update on the noisemon board new_noisemon_tf.pngnew_noisemon_spectra.pngold_noisemon_tf.pngold_noisemon_spectra.png
Entry  Sun Jan 6 15:37:39 2019, Duo, DailyProgress, , Isolated test of the oscillating op amp oscilliscope.jpgboard.jpg
    Reply  Tue Jan 8 22:47:07 2019, Duo, DailyProgress, , Isolated test of the oscillating op amp asdf.jpgaqf.jpg
Entry  Sat Dec 15 15:30:44 2018, Duo, DailyProgress, , Noise in the last Low pass sallen key filter IMG_0488.JPG
    Reply  Mon Dec 17 11:20:32 2018, rana, DailyProgress, Electronics, SR785 netgpibdata 
       Reply  Fri Jan 4 22:18:53 2019, Duo, DailyProgress, Electronics, Updates 8x
    Reply  Thu Jan 3 16:24:22 2019, Duo, DailyProgress, , Noise in the last Low pass sallen key filter 
Entry  Thu Jan 3 15:33:40 2019, Duo, DailyProgress, , New, Full noisemon completed MonitorCircuit.SchDocMonitorBoard.PcbDocMonitorBoard.SchDoc
Entry  Wed Dec 12 21:50:44 2018, Duo, DailyProgress, , New board arrived and other components on the board placed in Altium board.jpg
Entry  Fri Dec 7 18:27:27 2018, Duo, Misc, , Noisemon problem identified and another order placed 
Entry  Sat Nov 24 20:09:14 2018, Duo, Misc, , Noise monitor PCB assembly completed 
    Reply  Sun Nov 25 19:25:37 2018, rana, HowTo, Electronics, Noise monitor PCB assembly completed 
Entry  Sat Oct 20 00:38:43 2018, Duo, HowTo, , DAC Noise monitor PCB layers 
    Reply  Tue Oct 23 00:57:13 2018, Duo, HowTo, , DAC Noise monitor PCB layers NoiseMonitor.pdf
       Reply  Wed Oct 24 15:01:50 2018, Duo, HowTo, , DAC Noise monitor PCB layers NoiseMonitor.pdf
          Reply  Wed Oct 24 21:55:45 2018, Duo, HowTo, , DAC Noise monitor PCB layers NoiseMonitor.pdf
Entry  Mon Jun 4 11:15:17 2018, gautam, Lab Infrastructure, EquipmentLoan, Crackle lab ---> 40m 
Entry  Wed Oct 25 23:30:43 2017, Xiaoyue, DailyProgress, Crackle, Rebuild connectors summary_spectrum.pngsummary_spectrum.pngsummary_spectrum.png
ELOG V3.1.3-