Thu Sep 16 15:21:21 2021, Paco, DailyProgress, 1418 nm AUX ECDL, Free space AOM
|
Wed Sep 22 16:44:34 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, Free space AOM
|
Mon Oct 4 17:44:34 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, Free space AOM
|
Tue Oct 19 13:52:03 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1418nm ECDL Frequency noise 
|
Tue Mar 8 09:32:56 2022, Paco, DailyProgress, 1418 nm AUX ECDL, 1418nm ECDL Frequency noise   
|
Thu Sep 2 17:31:38 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1418 nm ECDL Relative Intensity Noise
|
Wed Jul 7 13:05:07 2021, Paco, DailyProgress, 1418 nm AUX ECDL, New aspheric flexures
|
Fri Jul 9 11:40:42 2021, Paco, DailyProgress, 1418 nm AUX ECDL, New aspheric flexures
|
Wed Jul 14 12:21:08 2021, Paco, DailyProgress, 1418 nm AUX ECDL, ECDL lases... and MZ locked mid-fringe
|
Wed Aug 4 11:36:30 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL with 2um AOM tests 
|
Tue Aug 10 09:51:44 2021, Paco, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz
|
Thu Aug 12 11:49:59 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz 
|
Tue Aug 17 11:09:29 2021, rana, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz
|
Wed Sep 1 13:12:02 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz
|
Tue Aug 10 11:00:43 2021, Paco, DailyProgress, DOPO, DOPO v2
|
Thu Jun 10 09:59:52 2021, Paco, Lab Infrastructure, DOPO, Disassembly for new optical table
|
Wed Jun 2 18:37:09 2021, Paco, Summary, Crackle, Vent crackle experiment
|
Thu May 20 17:09:43 2021, Koji, Summary, General, Another Heimann Sensor
|
Wed May 19 09:25:34 2021, Paco, Noise Hunting, DOPO, 316 Hz noise
|
Tue Mar 30 15:18:06 2021, Paco, Lab Infrastructure, EquipmentLoan, 2um CCD borrowed 
|
Tue May 18 10:28:50 2021, Paco, Lab Infrastructure, EquipmentLoan, heimann sensor update 
|
Wed Apr 14 16:49:30 2021, Paco, Misc, Optomechanics, DOPO mount v2
|
Tue Mar 9 19:21:38 2021, Paco, Misc, Optics, DOPO cavity pole
|
Thu Feb 25 10:28:07 2021, Paco, DailyProgress, Optics, DOPO lock endurance
|
Wed Feb 24 17:42:49 2021, Paco, DailyProgress, General, DOPO locking and SHG
|
Thu Feb 18 09:39:01 2021, Paco, DailyProgress, Electronics, PDH error signal misbehaving
|
Wed Feb 17 11:56:48 2021, Paco, Lab Infrastructure, Electronics, UPDH box zero model and SR560 "lock" 
|
Thu Feb 4 16:46:06 2021, Paco, DailyProgress, Optics, OPO cavity lock  
|
Fri Feb 5 14:15:22 2021, rana, DailyProgress, Optics, OPO cavity lock
|
Tue Feb 2 10:32:25 2021, Anchal, Summary, Optics, Figuring out how much astigmatism is hurting us
|
Tue Feb 2 17:39:52 2021, Paco, DailyProgress, Optics, re: Figuring out how much astigmatism is hurting us
|
Tue Jan 26 11:47:12 2021, Paco, DailyProgress, General, low quality PDH error signal
|
Wed Nov 18 17:49:05 2020, Paco, DailyProgress, Optics, beam profiles 
|
Mon Dec 21 16:35:14 2020, Anchal, DailyProgress, Optics, Took beam profile of laser right off the head  
|
Tue Dec 22 15:54:03 2020, Anchal, DailyProgress, Optics, Took beam profile of near EOM area
|
Mon Dec 28 15:51:51 2020, Anchal, DailyProgress, Optics, Mode matching solution for Cavity
|
Thu Dec 31 16:41:59 2020, Anchal, DailyProgress, Optics, Mode matching solution for Cavity
|
Wed Jan 6 09:34:34 2021, Anchal, DailyProgress, Optics, Corrected analysis and found better solutions.
|
Fri Jan 8 17:00:26 2021, Anchal, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Fri Jan 8 17:17:19 2021, Anchal, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Tue Jan 26 11:33:32 2021, rana, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Tue Jan 26 11:34:51 2021, rana, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Fri Jan 15 17:21:53 2021, Paco, DailyProgress, Electronics, RFPD TF
|
Fri Jan 15 10:57:39 2021, Paco, Lab Infrastructure, EquipmentLoan, Borrow AG4395A and EOM Driver TF re-tune 
|
Wed Jan 13 17:52:35 2021, Paco, DailyProgress, Optics, OPO cavity resonance 
|
Thu Jan 7 17:09:16 2021, Paco & Anchal, DailyProgress, Optics, Mode matching OPO
|
Thu Jan 7 09:44:52 2021, Paco, DailyProgress, Optics, Shaping the OPO cavity mode
|
Wed Dec 30 09:57:56 2020, Paco, DailyProgress, Optics, DOPO crystal oven 
|
Wed Dec 23 15:43:01 2020, Paco, DailyProgress, , OPO cavity assembly
|
Thu Dec 17 12:01:54 2020, Paco, Lab Infrastructure, Optics, crystal ovens, clips and controllers
|
Thu Dec 17 11:59:14 2020, Paco, Misc, EquipmentLoan, beam profiler
|
Wed Dec 16 22:13:43 2020, anchal, Misc, EquipmentLoan, Took delay line box, compressed nitrogen cylinder and lens
|
Wed Dec 16 22:38:55 2020, Koji, Misc, EquipmentLoan, Took delay line box, compressed nitrogen cylinder and lens
|
Tue Dec 15 13:00:41 2020, anchal, Lab Infrastructure, EquipmentLoan, Received Marconi and Rb clock from CTN
|
Fri Dec 11 17:53:07 2020, Paco, DailyProgress, Electronics, UPDH box alternative power supply
|
Fri Dec 11 16:04:36 2020, Paco, Lab Infrastructure, Optics, PPKTP crystals 
|
Wed Dec 9 18:03:31 2020, Paco, DailyProgress, General, Lab organization
|
Wed Dec 9 17:47:12 2020, Paco, Misc, Electronics, quick test of 14.75 MHz RFPD  
|
Thu Dec 3 12:20:19 2020, Anchal, Summary, Electronics, Tuned and characterized EOM Driver for 37 MHz phase modulation 
|
Tue Dec 1 18:37:09 2020, Paco, DailyProgress, Optics, OPO pump steering
|
Tue Nov 24 16:30:59 2020, Paco, Misc, EquipmentLoan, broadband EOM
|
Mon Nov 23 11:44:13 2020, Paco, Misc, General, MDT694B python controller
|
Tue Nov 24 12:32:56 2020, Koji, Misc, General, MDT694B python controller
|
Wed Nov 18 09:14:11 2020, shruti, Misc, EquipmentLoan, beam profiler
|
Wed Nov 18 14:29:00 2020, Koji, Misc, EquipmentLoan, beam profiler
|
Mon Nov 23 11:43:26 2020, Paco, Misc, EquipmentLoan, beam profiler
|
Tue Oct 20 20:41:59 2020, Koji, Summary, General, Delivered the instrument / components for 2um ECDL
|
Fri Nov 20 18:43:31 2020, Koji, Summary, General, Delivered the instrument / components for 2um ECDL
|
Wed Nov 11 12:55:18 2020, Paco, Lab Infrastructure, General, 1064 pump power curve
|
Mon Nov 9 17:38:18 2020, Paco, DailyProgress, General, SAF gain chip first light   
|
Tue Nov 10 00:02:20 2020, Koji, DailyProgress, General, SAF gain chip first light
|
Tue Nov 10 10:32:57 2020, Paco, DailyProgress, General, SAF gain chip first light
|
Wed Nov 11 12:28:33 2020, Paco, DailyProgress, General, EP30 softening
|
Fri Nov 6 11:58:02 2020, Koji, Lab Infrastructure, General, ECDL Gratings / Lenses delivered. Powermeter lending from OMC Lab
|
Fri Nov 6 10:47:49 2020, Paco, DailyProgress, General, Connecting SAF1900S 
|
Wed Nov 4 01:25:37 2020, Koji, Summary, Optics, Aspheric Lenses and Grating Plates bonded on their mounts  
|
Mon Nov 2 18:23:46 2020, Paco, DailyProgress, General,
|
Wed Oct 28 17:29:14 2020, Paco, Summary, General, Lab organization 
|
Thu Feb 13 00:25:36 2020, Duo, DailyProgress, , Noisemon at L1 
|
Wed Mar 11 12:46:20 2020, rana, Computing, Noise Budget, Noisemon at L1
|
Sat Apr 18 16:21:32 2020, Duo, Computing, Noise Budget, Noisemon:DAC noise analysis from L1 and H1  
|
Mon Apr 20 22:56:30 2020, rana, DailyProgress, Noise Budget, Noisemon:DAC noise analysis from L1 and H1 
|
Mon Feb 3 17:15:59 2020, Duo, DailyProgress, Electronics, Some confusing noisemon findings 12x
|
Tue Feb 4 17:30:50 2020, Duo, DailyProgress, Electronics, Some confusing noisemon findings   
|
Tue Jan 21 16:13:03 2020, Duo, DailyProgress, , Distortion of noisemon    
|
Tue Jan 28 08:46:13 2020, rana, DailyProgress, Electronics, Distortion of noisemon
|
|