Message ID:
1871
Entry time:
Thu Dec 3 12:20:19 2020
Author:
Anchal
Type:
Summary
Category:
Electronics
Subject:
Tuned and characterized EOM Driver for 37 MHz phase modulation
Measurement details:
Connected New Focus 4004 broadband IR phase modulator to the output of the SN06 EOM driver.
Splitted R output of AG4395A. One end went to the input of SN06 EOM driver.
The other end goes to input R of Ag4395A.
The RFMon of the driver is fed to input A of AG4395A.
Used a tuning stick for the coilcraft inductor to tune the resonance peak to 36 MHz.
Took measurements with the configuration files in this directory.
Data
Attachment 1:
EOMDriver_TF_Inp_to_RFMon_CloseUp_03-12-2020_121040.pdf
24 kB
|
Hide
|
Hide all
Attachment 2:
EOMDriver_TF_Inp_to_RFMon_Wide_03-12-2020_120819.pdf
31 kB
|
Hide
|
Hide all
ELOG V3.1.3-