40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog, Page 7 of 34  Not logged in ELOG logo
Entry  Fri Sep 7 23:12:51 2018, awade, Misc, Lab Monitoring, Temperature logging started in ATF lab 
    Reply  Sat Sep 8 17:14:37 2018, awade, Misc, Lab Monitoring, Temperature logging: activity in lab 
    Reply  Thu Oct 11 20:29:00 2018, awade, Misc, Lab Monitoring, Temperature logging started in ATF lab 20181011_ATFLabTemp_Sep9toOct11_AbsUncal_HourTrend.pdfMinuteTrend_Sep_atfLabTempData.txt
Entry  Mon Aug 6 03:45:37 2018, Vinny W., DailyProgress, 2micronLasers, Thermal Sensor Circuit Update scheme_voltageref.JPGscheme_thermalsensor.JPG20180806_162441.jpg20180806_135423.jpg
    Reply  Tue Aug 7 10:47:43 2018, awade, DailyProgress, 2micronLasers, Thermal Sensor Circuit Update LISOModel_Sallen-Key.ipynb.zip
       Reply  Thu Sep 6 10:19:54 2018, awade, DailyProgress, 2micronLasers, Thermal Sensor Circuit: Modifications 8x
Entry  Thu Aug 30 18:13:28 2018, awade, Howto, General, Running Acromag IOC epics servers out of docker modbus__defaults.zipDockerfile
Entry  Wed Aug 29 17:43:05 2018, John Martyn, DailyProgress, Homodyne, An Elusive Short Circuit and a Functional BHD 6x
Entry  Wed Aug 22 14:13:18 2018, Rahul, Lab Infrastructure, , Cryo-vacuum chamber layout cryo_vacuum_schematic.jpg
Entry  Tue Aug 14 13:44:47 2018, Vinny W., DailyProgress, 2micronLasers, Noise Analyses 
Entry  Tue Aug 14 10:14:11 2018, John Martyn, DailyProgress, Homodyne, BHD Circuits and Set Up BHDPictures.pngBHD_TF3.pdfBHD_Noise.pdfBHDCircuit1.pdf
Entry  Fri Aug 10 21:55:52 2018, John Martyn, DailyProgress, Homodyne, BHD Electronics BHD_TF2.pdf
    Reply  Mon Aug 13 19:15:47 2018, awade, John Martyn, DailyProgress, Homodyne, BHD Electronics, digitizing 
Entry  Thu Aug 2 18:14:36 2018, John Martyn, DailyProgress, Homodyne, Outreach IFO Photodetector image3.pdfimage2.pdfimage1.pdfOutreachPDCircuit3.pdf
Entry  Thu Jul 19 11:50:11 2018, Vinny W., DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA TIAcircuit.JPGTIAnoiseanalysis.JPG
    Reply  Sat Jul 21 14:17:20 2018, awade, DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA notebook_pyliso_WOPO1mmTransImp-v3.ipynb.zip
    Reply  Thu Aug 2 18:06:54 2018, awade, DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA 
Entry  Fri Jul 27 15:50:16 2018, Aidan, Computing, TempCtrl, FB4 has stopped recording second trends 
Entry  Wed Jul 25 19:21:19 2018, John Martyn, DailyProgress, Homodyne, Transimpedance Amplifier and Photodiode Characterization TIA_Noise.pdfTIA_Transfer_Function.pdfNoise_and_Transfer_Function_Measurements.zipTIAPic.PNGTransImpAmpCircuit2.pdf
    Reply  Fri Jul 27 12:26:58 2018, John Martyn, DailyProgress, , Progress 7/25/18 
Entry  Thu Jul 26 17:49:28 2018, Vinny W., DailyProgress, 2micronLasers, Power Loss through different optic components poweranalysis.JPG
Entry  Sun Jul 22 11:47:02 2018, John Martyn, DailyProgress, Homodyne, Progress 7/22/18 TIANoise.pngTIATransferFunction.pngSallenKeyPD4.pdf
    Reply  Sun Jul 22 20:12:23 2018, awade, DailyProgress, , Progress 7/22/18 
Entry  Mon Jul 16 22:56:06 2018, John Martyn, DailyProgress, Homodyne, Transimpedance Amplifier Design SallenKeyPD2.pdf
    Reply  Sat Jul 21 14:28:34 2018, awade, DailyProgress, M2 ISS, Progress 7/17/18 
Entry  Sat Jul 21 01:45:00 2018, Vinny W., DailyProgress, 2micronLasers, The Gentle Sway of the EP2004 p_aafo_i.png20180720_181301.jpg20180720_174216.jpg
    Reply  Sat Jul 21 13:32:07 2018, awade, DailyProgress, 2micronLasers, The Gentle Sway of the EP2004 
Entry  Wed Jul 11 16:30:40 2018, Vinny W., Summary, 2micronLasers, Acoustic and Thermal Sensitivity 
Entry  Fri Jul 6 22:30:20 2018, John Martyn, DailyProgress, Homodyne, Beam Profiling VoltageFit1.pngwFit.png
Entry  Mon Jul 2 11:23:06 2018, John Martyn, DailyProgress, Homodyne, BHD Optical Setup 
Entry  Tue Jun 19 14:38:23 2018, Aidan, Electronics, TMTF, Ordered clamp plates to mount TECs to fiber for low-bandwidth control TOP_clamp_fiber_TEC.pdfBASE_clamp_fiber_TEC.pdf
    Reply  Thu Jun 28 16:59:17 2018, Aidan, Electronics, TMTF, Ordered clamp plates to mount TECs to fiber for low-bandwidth control IMG_4256.jpgIMG_4257.jpgIMG_4254.jpg
Entry  Tue Jun 26 17:35:33 2018, John Martyn, DailyProgress, Homodyne, First Week Progress 
Entry  Tue Jun 5 13:59:43 2018, Eric, Summary, , LabJack Summary 9x
Entry  Tue May 29 16:12:48 2018, awade, Lab Infrastructure, Computing, Upgraded top level QIL/PSL/TCS lab's router IMG_3440.JPG
Entry  Sun May 27 16:10:27 2018, awade, Computing, Computing, Accessing 3com switch from screen on mac 
Entry  Wed Jan 17 10:41:45 2018, awade, Summary, WOPO, Making a transformer coupled photodiodes BasicSchematic_TranCoupledPD.pdf
    Reply  Wed May 23 20:38:10 2018, rana, Summary, WOPO, Transformer coupled photodiodes 
Entry  Sat May 5 06:08:35 2018, Eric, Update, , LabJack U3 New Setup Figure1.JPGFigure2.JPG
Entry  Mon Apr 23 12:44:07 2018, Jon Richardson, Computing, General, Added TCS/AWC Lab Port Forwards back to Linksys Router TCS-AWC_port_fwd.jpg
Entry  Thu Mar 8 13:23:57 2018, Craig, awade, Computing, General, gateway Linksys router was wiped via factory-reset, awade saves the day LinksysSetupBasicSetup.pngLinksysSetupApplicationAndGamingPortRangeForwarding.png
Entry  Thu Feb 22 12:09:20 2018, Jon Richardson, Computing, General, Reset Gateway Router 
    Reply  Thu Feb 22 12:13:27 2018, awade, Computing, General, Reset Gateway Router 
Entry  Thu Feb 15 16:58:31 2018, Eric, Misc, General, Plan for LabJack U3-HV 20KHz.png20Hz-10KHz.pngLabJack_diagram.JPG
Entry  Fri Feb 9 15:20:59 2018, Aidan, Electronics, Cameras, Heimann Sensor thermopile array qualitative test 10x
Entry  Mon Feb 5 15:12:06 2018, Aidan, Computing, General, Major error with FB4 clock 
Entry  Fri Jan 27 13:36:04 2017, Aidan, Lab Infrastructure, PEM, Got old PEM sensors running with Windows 7 OPC server 
    Reply  Sat Feb 3 17:21:28 2018, awade, Lab Infrastructure, PEM, Modified Newport Sensors to use USB power in instead of AAs IMG_2261.JPGIMG_2263.JPGIMG_2264.JPG
Entry  Wed Jan 3 20:20:07 2018, awade, DailyProgress, WOPO, Reboot WOPO 
    Reply  Wed Jan 10 17:03:55 2018, awade, DailyProgress, WOPO, WOPO some shot noise numbers 
Entry  Fri Nov 10 20:23:48 2017, awade, Computing, , Reset top level router 
    Reply  Sun Dec 10 15:12:22 2017, awade, Computing, , Reset top level router 
Entry  Sun Dec 10 04:48:59 2017, rana, Computing, General, dokuwiki updated 
Entry  Sun Nov 5 15:12:06 2017, rana, Summary, Computing, diaggui on Mac laptops 
Entry  Wed Sep 27 12:41:57 2017, Jon Richardson, Lab Infrastructure, Computing, TCS Subnet Back Up 
Entry  Thu Sep 21 12:25:05 2017, awade, Computing, Computing, Rebuild ws1 in ATF 
Entry  Mon May 22 17:08:33 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
    Reply  Mon May 22 23:40:42 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
    Reply  Thu Sep 21 12:03:27 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
Entry  Mon Sep 18 19:29:24 2017, awade, Computing, General, Internet access down 
    Reply  Mon Sep 18 20:46:43 2017, awade, Computing, General, Internet access down 
Entry  Fri Sep 15 14:12:38 2017, Aidan, Lab Infrastructure, General, QIL (ATF) Lab preparation for the plumbing work 13x
Entry  Wed Sep 6 11:51:40 2017, Jon, Lab Infrastructure, Computing, Gateway PC set up 
Entry  Wed Sep 6 11:50:12 2017, Jon, Lab Infrastructure, Computing, Gateway PC set up 
Entry  Wed Aug 30 21:22:20 2017, awade, Lab Infrastructure, CDS, Reboot fb1 
Entry  Tue Aug 29 20:59:11 2017, awade, Jon, Lab Infrastructure, Computing, Setting up a gateway PC 
Entry  Sun Aug 27 21:55:14 2017, awade, Computing, Computing, Mapping the ATF/PSL/TCS lab 
    Reply  Mon Aug 28 17:11:47 2017, awade, Computing, Computing, Mapping the ATF/PSL/TCS lab 
Entry  Tue Aug 22 11:59:56 2017, awade, Safety, General, Leak in the ATF Lab 2017-08-22_11.58.43.jpg
    Reply  Thu Aug 24 13:47:00 2017, Aidan, Safety, General, Leak in the ATF Lab IMG_0673_(1).jpgIMG_0674_(1).jpgIMG_0675_(1).jpgIMG_0676_(1).jpg
Entry  Wed Aug 16 19:04:47 2017, Amani Garvin, DailyProgress, Scatterometer, Image of Beam in Silicon 200ms_Beam_Through_Sample.tify_norm_axis_counts.pngx_axis_counts.pngLASERBEAM_calibrated.tif
Entry  Wed Aug 16 10:16:25 2017, Amani Garvin, DailyProgress, Scatterometer, Varying the Distance Between Camera and Silicon 10x
ELOG V3.1.3-