  2121   Tue Jun 13 16:45:38 2017 DhruvaLaserWOPODiabolo ProfilingI reprofiled the 1064 beam today. I also
found that the DataRay software gives me
the beam diameter and not the spot size.
 532_profile.pdf1064_profile.pdf 
  2122   Fri Jun 16 18:55:40 2017 DhruvaUpdateWOPOMode Matching the 1064nm Beam into fibreIn order to collimate the 1064nm beam from
the laser into the fibre, we are using the
Thorlabs F240-APC-1064 fixed focus collimation
 3_lens_solution.pdf1064_f1_profile.pdf1064_f2_profile.pdfMode_Matching_Lenses.jpg 
  2123   Thu Jun 22 16:45:17 2017 DhruvaLaserWOPOAdvR Waveguide Spec SheetHere is the spec sheet for the squeezing
waveguide

Please, don't place
  
  2124   Mon Jun 26 10:55:02 2017 DhruvaUpdateWOPOTemperature Control of the PPKTP WaveguideFor the temperature control of the non
linear waveguide, we will be using the Newport
3040 Temperature Controller. The phase matching
 10x 
  2125   Tue Jun 27 11:34:00 2017 DhruvaUpdateWOPOMode Matching Woes - Fibre issuesThe WOPO experiment has been quite stagnant
for the last two weeks because ineffective
coupling of the 1064 light into the fibre
 image2.JPGimage4.JPG 
  2126   Wed Jun 28 13:24:35 2017 awadeUpdateWOPOPDs for homodyne detectorI asked Koji if he had any hight QE photodiodes
to use in a ballenced homodyne detector.
 None of the Ad LIGO ones can be used
 2017-06-28_13.21.32.jpg2017-06-28_13.17.32.jpg2017-06-28_13.17.00.jpg2017-06-28_13.16.51.jpg 
  2127   Wed Jun 28 20:05:02 2017 KojiUpdateWOPOPDs for homodyne detectorI beieve that they are Exelitas C30642.
FYI: There also is one on the former-gyro
optical table. This one doesn't have
  
  2128   Thu Jun 29 22:42:28 2017 awadeUpdateWOPOMode Matching Woes - Fibre issuesI've reordered fiber that was damaged.
 

Need to profile the beam actually
  
  2129   Fri Jun 30 12:17:07 2017 KojiUpdateWOPOMode Matching Woes - Fibre issuesMeasure the profile of the back propagation
beam by injecting a beam from the other side.
This gives you how the input mode
  
  2130   Sun Jul 2 19:47:35 2017 awadeUpdateWOPOMode Matching Woes - Fibre issuesDo you recall if there are any fiber coupled
1064 nm lasers anywhere in the 40m or other
bridge west labs?
  
  2131   Sun Jul 2 21:21:39 2017 KojiUpdateWOPOMode Matching Woes - Fibre issuesJenne's laser at the 40m PD testing
table is a fiber coupled 1064nm DL.

But you just can couple 5~10% of
  
  2132   Wed Jul 5 16:44:34 2017 KojiUpdateWOPOPDs for homodyne detectorCorrection: If the diode is 3mm x 3mm,
it is Excelitas C30665.
  
  2133   Thu Jul 6 15:03:07 2017 DhruvaUpdateWOPOHomodyne DesignI am attaching a schematic of the proposed
design for the Homodyne detector. The damping
capacitance in the two photodetectors has
 Homodyne.pdf 
  2135   Mon Jul 10 12:12:26 2017 DhruvaUpdateWOPOEfficient Fibre Coupling and Phase Matching PlotUsing the 632nm laser provided by Gautam
to back couple the 1064nm light into the
fibre, I managed to finally get efficient
 Phase_Matching.pdfGreen_Loss_1.jpgGreen_Loss_2.jpg 
  2140   Mon Jul 17 22:19:36 2017 DhruvaSummaryWOPOLast Week in WOPO1. I have achieved 50% fibre coupling efficiency
for the 532nm beam. I have attached the simulation
of the estimated solution in ABCD and
 532_MM.pdf532_f1.pdf532_f2.pdfsm1064att.pdfsm1064out.pdf 
  2141   Tue Jul 18 22:09:14 2017 DhruvaUpdateWOPOPhotodetector Dark NoiseThese are the plots of the dark noise of
the Thorlabs photodetectors lying in the
ATF lab using the FFT network analyser. For
 20170714-pda55noise.pdf 
  2142   Thu Jul 20 18:16:33 2017 ranaUpdateWOPOPhotodetector Dark NoiseUgh - I deleted those 1000 bad plots. Just
give us 1 trace per PD, all on one plot.
Each trace should also include the model
  
  2144   Sat Jul 22 14:25:55 2017 DhruvaUpdateWOPOTable Noise Issues Yesterday, with a lot of help from Koji,
we built the transimpedance circuit (Gain
= 10k) for the photodetectors of the
 20170721-_table_noise.pdf20170721_Circuit_in_Air.jpg20170721_Circuit_on_Table.jpg 
  2145   Sat Jul 22 14:41:07 2017 DhruvaUpdateWOPOPhotodetector Dark Noise 




 20170721-dark_noise.pdf 
  2146   Sat Jul 22 14:43:16 2017 DhruvaUpdateWOPOSubtractor Circuit NoiseI also made a op-amp subtractor circuit
for the homodyne detector and measured the
noise. It is significantly lower than the
 20170721-subnoise.pdf 
  2187   Wed Jan 3 20:20:07 2018 awadeDailyProgressWOPOReboot WOPOLaser restarted + 1064 for Shotnoise +
SQZ measurment

I've restarted
the Diabolo and am checking the alignment
  
  2188   Wed Jan 10 17:03:55 2018 awadeDailyProgressWOPOWOPO some shot noise numbersSummary, here are some numbers relating
to requirements for for the WOPO squeezing
detection:
  
  Draft   Wed Jan 17 10:41:45 2018 awadeSummaryWOPOMaking a transformer coupled photodiodes[DRAFT]

These are some some summary notes
on bandwidth and noise budget of transformer
 BasicSchematic_TranCoupledPD.pdf 
  2199   Wed May 23 20:38:10 2018 ranaSummaryWOPOTransformer coupled photodiodesWhat is going on with this fossilized squeezing
experiment? I reckon that there is a loss
diagram out there somewhere. Le'ts see
  
  2225   Thu Aug 2 15:01:21 2018 awadeDailyProgressWOPOBuilding a SN limited detector for WOPO experimentFor WOPO squeezing detection I've ditched
the idea of using a transformer coupled PD:
its a nice idea but more complicated that
 6x 
  2229   Mon Aug 6 17:30:53 2018 awadeDailyProgressWOPOToo much RIN, making a balanced detectorI tweaked up the alignment into the 1064
nm fiber and directed 1 mW onto my new detector. 
The noise I see is well in excess of the
 plot20180803_Single6p8kTIADect_NoiseSpectrum.pdfSch20180806_SumWtTrim_IMG_3631.JPG 
  2231   Thu Aug 9 16:51:43 2018 awadeDailyProgressWOPOTesting balanced detectorI did a number of initial tests and then
attempted to inject 30 mW of light into the
WOPO to see if I could at least some amplification
  
  2235   Mon Aug 13 01:48:48 2018 ranaDailyProgressWOPOSR560 battery as a voltage supplyWhen powering from the SR560 bananananas,
you should disconnect AC power, else it may
produce extra lines due to the charger.
  
  2236   Mon Aug 13 01:53:21 2018 ranaDailyProgressWOPOzero-span spec OR RF bandpassI know the squeezing people often use the
zero-span feature of a spectrum analyzer
to produce their McDonalds plots, but why
  
  2237   Mon Aug 13 15:43:55 2018 ChrisDailyProgressWOPOzero-span spec OR RF bandpassIt's also been done with the AD8361
eval board, for the 40m
squeezer way
  
  2241   Wed Aug 15 09:57:56 2018 awadeDailyProgressWOPOSR560 battery as a voltage supplyI think this was unplugged from the wall
at the time. I guess I should be careful
about the grounding in connections to the
  
  2242   Mon Aug 20 12:08:17 2018 awadeDailyProgressWOPOzero-span spec OR RF bandpasszero-span is just for a quick and dirty
measurement.  As long as the there is
ok noise clearance its usually enough to
  
  2243   Mon Aug 20 12:11:45 2018 awadeDailyProgressWOPOTesting (freespace) balanced detectorSmall polarization drift seems to have
a significant impact on splitting ratio of
the TN1064R5A2A. 
 18-08-17_22-59-08_3649.jpg 
  2244   Mon Aug 20 22:09:27 2018 awadeDailyProgressWOPOPZT broken no slow phase modulation on LOThis afternoon I constructed a Mach–Zehnder
around the PZT to confirm if it was actually
providing modulation.  It isn't.
  
  2245   Wed Aug 22 00:42:42 2018 awadeDailyProgressWOPONew PZT mounted mirrorKoji showed me the collection of PZTs at
the 40m.  I've epoxied a 9 mm mirror
to the end of a P-810.10 peizo
 18-08-22_22-28-27_3673.jpg18-08-22_22-32-51_3678.jpg18-08-22_22-34-17_3680.jpg18-08-23_12-02-38_3684.jpg18-08-23_12-02-48_3686.jpg 
  2247   Thu Aug 23 12:49:17 2018 awadeDailyProgressWOPONew PZT mounted mirror mountedThe bake overnight settled at 64 C. 
This wasn't quiet the minimum recomended
for EPO-TEK 353ND but
 IMG_3690_ThePriestAndTheBeast.JPG 
  2255   Fri Oct 12 19:05:51 2018 awadeDailyProgressWOPOGluing 532 nm PZT mirrorI'm making a PZT mounted 532 nm mirror,
so I have some independant control of the
pumping light phase for optimizing the classical
  
  2257   Mon Oct 29 19:05:58 2018 awadeDailyProgressWOPOFixing MM into 532nm collimatorAfter a number of changes to the path for
the pump light (532 nm) it has be very difficult
to get any decent amount of pumping power
 18-10-29_19-05-15_4347.jpg 
  2262   Wed Nov 28 12:14:35 2018 awadeDailyProgressWOPOMode field diameter choosing best patch for WOPO inputThere is some loss in fiber-to-fiber connection
when there is a different mode field diameter
between the two.  Ideally one would
  
  2268   Tue Dec 4 19:34:22 2018 awadeDailyProgressWOPODiabolo 532 nm power drop and retuningI restarted the Diabolo laser after
it had been shut down for a lab tour. 
The using the throlabs S130C head the 1064
 18-12-04_DiaboloInside_annotate.jpegplot20181204_DiaboloSHGRaligned1064nm.pdfplot20181204_DiaboloSHGRErrSig.pdf20181204_RetuneDiaboloSHGAlignment.zip 
  2273   Thu Dec 6 20:04:50 2018 awadeDailyProgressWOPODiabolo 532 nm power drop and retuningI've continued to have problems getting
the Diabolo laser SHG to lock. 

I get nice clean fundamental resonance
  
  2277   Fri Dec 7 20:31:06 2018 awadeDailyProgressWOPODiabolo: cleaning dust out of SHG unit, self heating issuesI've managed to vastly improve the
power output of the SHG by doing a little
cleaning inside the box.
 18-12-07_20-06-46_4774.jpg18-12-07_20-06-58_4776.jpg18-12-07_20-07-44_4780.jpgIMG_4785.JPGIMG_4766.MOV 
  2280   Thu Dec 13 14:01:13 2018 awadeDailyProgressWOPODiabolo: contacted coherentI've contacted the people at Coherent
about getting instructions for repair or
whether they can still service this unit
  
  2281   Thu Dec 13 16:24:06 2018 awadeDailyProgressWOPODiabolo: baseline numbers for coherentSome numbers for the Diabolo laser for
reference (to quote to Coherent, if they
get back to us with help).
 plot20181218_PhaseMatchingCurveFastScanDiaboloSHG.pdf20181213_SHGScanWithLNTempTuning.zip 
  2283   Wed Dec 19 16:48:18 2018 awadeDailyProgressWOPODiabolo: baseline numbers for coherentContact with Coherent re Diabolo

I
got in contact with Coherent they have provided
some instructions on aligning the laser cavity,
  
  2284   Thu Dec 20 19:20:50 2018 awadeDailyProgressWOPODiabolo: trialing SHG oven set temperature points to see if there is a maxima when lockedThe strategy locking at lower laser power
and optimizing phase matching temperature
by slowly walking the temperature and laser
 plot20181220_SHGLockedOutputVsOvenSetpointTemperature.pdf20181220_SHGLockedPowerVsSetPointTemp.zip 
  2286   Fri Dec 21 15:33:26 2018 KojiDailyProgressWOPODiabolo: trialing SHG oven set temperature points to see if there is a maxima when lockedThis means that you want to make the SHG
crystal longer. Is that true? If so, can
you change the temperature for the optimal
  
  2287   Fri Dec 21 15:51:27 2018 awadeDailyProgressWOPODiabolo: trialing SHG oven set temperature points to see if there is a maxima when lockedNo I don't think so.  The temperature
of the oven is important for the phase matching
condition.  Its the nob you can turn
  
  2289   Mon Dec 24 10:08:49 2018 awadeDailyProgressWOPODiabolo: back to power with deliberate pre-misalignmentI think I've managed to bring the power
of the Diabolo back to a usable level for
WOPO.
 18-12-21_22-04-30_4812.jpg18-12-21_22-04-54_4813.jpg18-12-21_22-07-55_4814.jpg 
  2290   Mon Dec 24 12:07:18 2018 KojiDailyProgressWOPODiabolo: back to power with deliberate pre-misalignmentGreat recovery job!

 
  