40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog, Page 54 of 56  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  1490   Thu Aug 4 16:01:34 2011 ranaLaserGYROAccelerometer calibrationto get a high precision relative calibration
you ought to do a huddle test like what Jenne
does. And plot the residual instead of 2
  
  1501   Tue Aug 9 15:03:54 2011 ranaLaserGYROHuddleIf you use the same X-scale for the accelerometer
coherence as for the spectra, I think that
you will see that there is no coherence below
  
  1529   Wed Aug 24 05:26:03 2011 ranaElectronicsGYROLC homodyne discriminatorThe reason I went for cable length instead
of LC, is that the LC is basically a version
of a VCO with a PLL, except that the VCO
  
  1532   Tue Sep 6 10:56:22 2011 ranaMiscGYROThermal Expansion Noise -> Gyro NoiseA nice webpage on making Iodine cells:

http://exoplanets.astro.yale.edu/instrumentation/iodine_cells.php
  
  1551   Sat Oct 15 11:03:18 2011 ranaLaserGYROmore testingI bet $5 that its
the NPRO's weirdness. Install the PMC and
see what's what.
  
  1558   Tue Oct 25 00:48:13 2011 ranaMiscGYROChandlerhttp://prl.aps.org/abstract/PRL/v107/i17/e173904   
  1682   Wed May 30 19:11:35 2012 ranaLaserGYRObetter AM TF 
  
  1684   Tue Jun 5 23:23:36 2012 ranaLaserGYRObetter AM TF Good idea. It doesn't matter exactly
how you measure it; its a linear system,
so as long as its locked you can measure
  
  1702   Wed Jun 27 10:34:06 2012 ranaElectronicsIodineTemp controller PCB almost done Temp controller
FP should be red.
 You sure that
  
  1705   Sun Jul 1 01:33:57 2012 ranaElectronicsIodineTemp controller design re-revised  I hope that 298 K is not   
  1728   Fri Aug 10 15:57:03 2012 ranaLaserGYROnoise spectrum with servos switched 
 My understanding is that the
next step is to squash the transmitted power
  
  1731   Sat Aug 11 11:51:51 2012 ranaLaserGYROCW_TRANS intensity noise testing My first impulse is to say that you
should set up a dual DC coupled ISS
using the trans light as the reference. Same
  
  1747   Fri Aug 24 15:47:22 2012 ranaLaserGYROPDH2 locking attempts 
 How about a high Q LC notch
instead?
  
  1757   Tue Sep 4 10:31:50 2012 ranaElectronicsGYROMarconi phase noise vs deviation

    

       
            
  
  1767   Thu Sep 13 10:20:36 2012 ranaElectronicsGYROExcess demod noise 
 Seems like if you fix this
excess RFPD noise, you could then lower the
  
  1777   Fri Oct 5 04:40:51 2012 ranaLaserGYROgyro frequency noise monitor set up 
 That's great news - there is
now a way to measure all the noise. I would
  
  1804   Wed May 1 21:47:20 2013 ranaElectronicsFiberBeat delay line transfer function 
 The delay line should be much
longer.
  
  1808   Fri May 3 01:15:15 2013 ranaElectronicsFiberBeat delay line transfer function 
 This is OK. Better to use a
1.9 MHz low pass after the mixer. And the
  
  1840   Mon Jun 3 18:57:34 2013 ranaComputingGeneralHow to make high quality plots in Matlabfigure(77)
 


 makePDF.csh 
  1870   Mon May 19 22:19:21 2014 ranaLaserGYROSeismometer filteringI think you got to use more seis channels
to make a good RZ. The residual that you
see is not the GUR noise, but due to improper
  
  1876   Fri Jun 20 09:19:41 2014 ranaLaserGYROGyro noise better by 10x *NOPE* Also, try out using Sujan's median
Welch PSD code to see if it estimates a lower
noise spectrum. Its better when there are
  
  1879   Sun Jun 22 12:38:44 2014 ranaElectronicsGYROMarconi noise measurement verification 
 But, to be realistic, don't
you have to use 2 Rubidium clocks to make
  
  1881   Tue Jun 24 10:47:35 2014 ranaElectronicsGYROMarconi noise measurement verification That's remarkable. If the gyro signal
can be read out from the 2nd loop error,
with no 2nd loop locking, it means that the
  
  1892   Fri Dec 19 12:22:37 2014 ranaLab InfrastructureGeneraloverhead lightsI noticed that some of the ceiling flourescent
lights are out. Since when have these ceiling
lights been out?
  
  1893   Tue Dec 23 19:58:49 2014 ranaElectronicsM2 ISSM2 bias/readout board evaluation 
 Re: the high ON resistance
of the CMOS switches:
  
  1907   Sun Feb 22 01:49:11 2015 ranaMiscSeismometerFinding Modal Frequencies of FrameRubber handles give too much low pass action
- use the plastic handle of a ball driver
instead. For a more calibrated result, even
  
  1921   Mon May 11 18:38:14 2015 ranaMiscSeismometerANSYS Videos and Building UpdateI would expect that there should be 2 more
modes in here, with frequencies between 0.1
and 4 Hz. The lowest mode is the pitch mode
  
  1924   Wed May 20 21:33:36 2015 ranaMiscSeismometerThermal Enclosure conceptWe want to make a thermal enclosure for
the seismometer. The attached diagram shows
the concept and I am hereby handing it off
 ThermalEnclosure.pdf 
  1926   Mon Jun 1 18:26:01 2015 ranaLab InfrastructureHVAChot spots in lab - hot air coming from Gyro table HEPAKate noticed that two spots were hot in
the lab. The east and west ends of the Gyro
optical table.
  
  1936   Tue Jun 16 17:09:46 2015 ranaMiscSeismometerThermal Enclosure conceptSome Foam Notes:


http://built-envi.com/portfolio/hot-box-measurements-of-wall-thermal-performance/
https://en.wikipedia.org/wiki/R-value_(insulation)


I've
  
  1938   Thu Jun 18 22:24:31 2015 ranaElectronicsPD noiseResistor noise observations,analysis and inferenceThis is possibly nice, but please replace
the EPS with PDF and make all of the fonts
(including superscripts) larger than the
  
  1958   Mon Jul 6 08:15:53 2015 ranaMiscTempCtrltemperature noise plotSince its hard to find, here is a plot
from Frank Siefert from years ago, showing
the temperature fluctuations in a metal box
 tempnoise_final.pdf 
  1959   Mon Jul 6 13:27:48 2015 ranaMiscSeismometerInverted Pendulum linksInverted Pendulum links:


http://dx.doi.org/10.1063/1.1149783
http://dx.doi.org/10.1016/j.nima.2007.08.161
https://en.wikipedia.org/wiki/Inverted_pendulum
  
  1983   Fri Jul 17 18:12:36 2015 ranaMiscPD noisePD noise updatesomething seems bogus here...the suppression
at 1 Hz is much more than the open loop gain.
usually this is mathematically impossible...
  
  1988   Fri Jul 24 17:59:39 2015 ranaMiscSeismometerMini thermal enclosure testI've ordered some thermal paste (should
show up at the 40m on Wednesday) for the
thermistors and 2 silicone heaters for the
  
  2011   Tue Jan 5 14:48:08 2016 ranaSafetyLab InfrastructureHVACheating and coolingAs noticed by Kate a few times last year,
the north side of the lab has hot air comiing
out of the HEPA vents and the south side
  
  2026   Sun Feb 21 14:27:24 2016 ranaMiscPD QEMeasurement of the enhanced QE of the PD without glass window My interpretation of this is that we get
~2% increase in the peak EQE for p-pol by
doing the extra bounce. Is that correct?
  
  2058   Wed Aug 3 18:46:13 2016 ranaMiscScatterometerGathering parts: 1550 nm scatter righttps://nodus.ligo.caltech.edu:8081/Cryo_Lab/46

This entry from Dmass lists the
high noise diode lasers we had in the cryo
 1772-NM-40-02-FC-PM.pdf 
  2059   Mon Aug 8 00:31:59 2016 ranaComputingGeneralWiki upgradeATF Wiki upgraded to 2016 Isabel version
of Docuwiki. Theme updated to Bootstrap3
using the Extension/Theme plugin updater.
  
  2060   Mon Aug 8 17:05:28 2016 ranaMiscGeneralRaspberry Pi beam profiles: possible student projecthttp://hackaday.com/2015/12/21/raspberry-pi-laser-beam-profiler/

UCLA project. Should we try to
make one of these?
  
  2065   Tue Sep 20 22:19:54 2016 ranaMiscScatterometerGathering parts: 1550 nm scatter rigI'd make a beam with a 0.5 mm waist
in the sample and then translate the sample
around so that we could measure scatter at
  
  2068   Wed Oct 5 10:50:24 2016 ranaLaserFiberfrequency noiseThis is a nice plot from https://doi.org/10.1364/OE.18.022781 (Kenji's
laser noise paper) comparing the frequency
noise of different papers. Worth comparing
 oe-18-22-22781-g007.pdf 
  2076   Thu Dec 8 20:43:44 2016 ranaLab InfrastructureGeneralLab flooding and AC control issuesNeed to have a couple of room temperature
sensors logged into the frames so that we
can do long term lookback of the lab temperature.
  
  2080   Tue Jan 3 20:15:12 2017 ranaLaserTMTFfiber based laser phase noise measurementsThe Folks at IIT Madras (Deepa, Shanti,
and Anil) recommend making a heterodyne measurement
instead to get away from the 1/f noise in
  
  2084   Sat Jan 28 13:02:40 2017 ranaThings to BuyCDScheap DAQSome more cheap DAQ interfaces, whether
for coffee or in the labs without CyMac:

https://labjack.com/
  
  2087   Wed Apr 19 10:57:42 2017 ranaLaserGYROlaser to LiyuanNPRO from Gyro table lent to Liyuan for
cavity ringdown / contamination tests.
  
  2089   Thu Apr 20 13:26:23 2017 ranaLaserTMTFDET-10 thoughtsThe DET-10D
is an extended InGaAs photodiode which is
biased either using a battery or an external
 DET10D.pdf 
  2092   Wed Apr 26 18:40:30 2017 ranaComputingGeneralATF Wiki updatedto 2017-02-19b
"Frusterick Manners" +CAPTCHA +Wrap
  
  2108   Tue May 23 15:19:48 2017 ranaLab InfrastructureRF10 MHz reference distribution system planningThis is pretty close, but for the section
that runs down from the cable tray to the
breakout box, it needs to be 
  
  2110   Tue May 23 16:59:39 2017 ranaLab InfrastructureRF10 MHz reference distribution system planningFULLY ENCLOSED!!!!! less Mickey Mouse   
ELOG V3.1.3-