40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog, Page 1 of 34  Not logged in ELOG logo
Entry  Sun Oct 21 23:06:49 2007, rana, Lab Infrastructure, HVAC, Its too cold again 
Entry  Sun Oct 21 23:11:20 2007, rana, Laser, MOPA, Laser Turn on report 
Entry  Mon Oct 22 20:04:28 2007, rana, Misc, General, Magnetic Levitation Giazotto-ESmirror.pdf
Entry  Fri Oct 26 15:38:43 2007, Tobin Fricke, Laser, PSL, Polarizer polarizer.pdfpolarizer.m
Entry  Sun Nov 4 23:44:36 2007, rana, Laser, PSL, More Laser setup info 
Entry  Wed Oct 24 23:50:27 2007, dmass, Laser, General, Tip Tilt Frequency Response 6x
    Reply  Thu Nov 8 01:58:37 2007, dmass, Laser, General, Tip Tilt Frequency Response allfour.jpgTTstruc.JPGPit_Yaw.pdf
Entry  Thu Nov 8 18:54:41 2007, Stefan, Laser, PSL, 35W laser ISS loop closed with LIGO ISS electronics 
Entry  Mon Nov 12 21:33:41 2007, Stefan, Laser, PSL, ISS servo work 
    Reply  Tue Nov 13 19:06:18 2007, rana, Laser, PSL, ISS servo work 
Entry  Wed Nov 28 16:20:04 2007, Andrey , Lab Infrastructure, General, Enclosure cleaning 
Entry  Wed Dec 12 16:10:19 2007, tobin, Lab Infrastructure, HVAC, Lab Temperature 
Entry  Wed Dec 12 16:19:00 2007, tobin, Lab Infrastructure, HVAC, Lab Temperature temperature.pdf
Entry  Thu Dec 13 18:47:02 2007, tobin, Lab Infrastructure, HVAC, Lab Temperature 
Entry  Tue Dec 18 13:49:50 2007, tobin, Lab Infrastructure, HVAC, Lab Temperature temperature-20071218.pdf
Entry  Fri Dec 21 21:27:12 2007, tobin, Lab Infrastructure, HVAC, Lab Temperature 
Entry  Wed Dec 26 21:30:05 2007, rana, Laser, PSL, laser power 
Entry  Wed Jan 2 15:10:24 2008, tobin, Lab Infrastructure, HVAC, Lab Temperature 
Entry  Thu Jan 24 19:43:53 2008, Stefan, Electronics, ISS, ISS servo work ISSOLG.pdfISSnoise.pdf
Entry  Mon Jan 28 16:51:06 2008, Stefan Ballmer, Laser, PSL, PDH locked pre-mode cleaner 
Entry  Mon Jan 28 18:02:04 2008, Stefan Ballmer, Laser, General, 1.2MHz Laser intensity oscillation 
Entry  Tue Jan 29 12:50:00 2008, Dmass, Things to Buy, General, Things to buy wiki 
Entry  Wed Jan 30 12:57:53 2008, Dmass, Laser, PSL, Characterizing Beam 
Entry  Tue Feb 5 18:59:07 2008, Stefan Ballmer, Laser, General, Bork-space running 
Entry  Sun Feb 10 13:18:07 2008, Stefan Ballmer, Laser, General, Trend of Laser Power over 20h LaserPower20h.png
Entry  Sun Feb 10 13:27:57 2008, Stefan Ballmer, Computing, General, Pictures of Bork-Space setup CIMG3586.JPGCIMG3587.JPGCIMG3588.JPGCIMG3589.JPG
Entry  Tue Feb 12 16:54:13 2008, Dmass, Laser, PSL, 35W profile/waist 
Entry  Tue Feb 12 17:00:35 2008, Dmass, Laser, PSL, Mode Matching/Lock PMC_MM.JPGlenses_mmJPG.JPG
Entry  Sat Feb 16 13:46:19 2008, Dmass, Laser, PSL, Laser Aperture closed. 
Entry  Sat Feb 16 15:33:25 2008, Dmass, Laser, PSL, Radial Beam Profile 2_16_0835w.bmp
Entry  Tue Feb 26 19:52:08 2008, Rana, Electronics, CDS, channels 
Entry  Tue Feb 26 21:05:47 2008, Stefan Ballmer, Laser, General,  
Entry  Wed Feb 27 17:14:47 2008, Stefan Ballmer, Electronics, General, PZT driver powered up 
Entry  Wed Feb 27 17:56:45 2008, Stefan Ballmer, Electronics, General,  
Entry  Mon Mar 3 01:21:19 2008, rana, Laser, MOPA, power drift test.pngtest2.png
Entry  Tue Mar 4 16:00:28 2008, Dmass, Laser, PSL, ISS 
Entry  Fri Mar 7 15:33:14 2008, Dmass, Laser, EOM, EOM shipped 
Entry  Thu Mar 27 13:25:38 2008, Stefan Ballmer, Laser, ISS, Modifications to ISS (D080149-00-C) D080149-00-C.pdf
Entry  Tue Apr 1 20:50:37 2008, Dmass, Laser, EOM, Transfer Function EOM_PD_xsfer.jpgHFlogxsfer.jpgHFxsfer.jpg
    Reply  Thu Apr 3 17:56:35 2008, Dmass, Laser, EOM, Transfer Function EOMPMCTF.png
Entry  Fri Apr 11 16:37:03 2008, Stefan Ballmer, Computing, General, Set up CDS wireless router / controlling from nokia handheld works 
Entry  Fri Apr 11 17:15:49 2008, Dmass, Laser, EOM, Transfer Function EOM_PMC_tf.png
Entry  Mon Apr 7 16:43:15 2008, Dmass, Laser, PSL, Profile of 35W PSL scancap.png3dbeamprof.bmpflatprof.bmpApr7_08scan.asc.zip
    Reply  Tue Apr 22 16:25:24 2008, rob, Laser, PSL, Profile of 35W PSL 
       Reply  Tue Apr 22 20:07:50 2008, Dmass, Laser, PSL, Profile of 35W PSL 
Entry  Fri Apr 25 13:33:35 2008, Dmass, Laser, PSL, power drift trend2.pngtrend3.png
Entry  Tue Jan 29 12:47:44 2008, Dmass, Laser, General, Strange Noise 
    Reply  Fri May 2 21:09:26 2008, Dmass, Laser, General, Strange Noise 
Entry  Fri May 2 21:39:13 2008, Dmass, Laser, PSL, Laser power on table lowered 
Entry  Fri May 2 22:00:17 2008, Dmass, Computing, , Daq Channels 
Entry  Fri May 2 22:54:44 2008, Dmass, Computing, , Screens 
Entry  Mon May 5 20:32:50 2008, Dmass, Computing, General, MEDM, FB, FE, Etc 
Entry  Wed May 7 04:44:31 2008, Dmass, Computing, General, DTT and Fast Channels fixed 
Entry  Tue May 13 12:37:31 2008, Dmass, Laser, Fiber, New fiber 00011.png
Entry  Tue May 6 18:18:59 2008, Dmass, Laser, EOM, EOM Phase lag TF_setup1.pngMODSUM.png
    Reply  Tue May 20 15:55:31 2008, Dmass, Laser, EOM, EOM Phase lag RawTF.pngcorrtf.png
Entry  Thu May 29 20:00:48 2008, tobin, Computing, Fugly, borkspace compiling 
Entry  Sun Jun 1 18:52:49 2008, tobin, Computing, General, borkspace compiling 
Entry  Fri Jul 11 16:20:21 2008, Stefan Ballmer, Electronics, , PMC 
Entry  Mon Jul 14 16:01:45 2008, Stefan Ballmer, Electronics, ISS, H1 ISS spare tested 
Entry  Wed Jul 16 11:47:18 2008, Dmass, Computing, General, Front End Machine Namechange 
Entry  Thu Jul 17 16:44:27 2008, Dmass, Laser, PSL, Laser is off 
Entry  Fri Jul 18 16:14:28 2008, Dmass, Electronics, General, Universal PDH box PDH_User_Manual1.pdfUniPDH.png
    Reply  Wed Jul 23 12:04:01 2008, Dmass, Electronics, General, Universal PDH box PDH_LF.pngPDH_HF.png
Entry  Tue Jul 22 18:43:06 2008, Dmass, Computing, fubar, digital control broken. 
    Reply  Fri Jul 25 14:59:24 2008, Dmass, Computing, fubar, digital control broken. 
Entry  Fri Jul 25 15:23:14 2008, Dmass, Laser, PSL, New Vertical PSL NPRO.pngHEPA.png
Entry  Mon May 19 17:28:44 2008, Dmass, Laser, PMC, Cavity Pole Measurement on the PMC 
    Reply  Fri Jul 25 17:07:34 2008, Dmass, Laser, PMC, Cavity Pole Measurement on the PMC 
Entry  Tue Jul 29 00:47:37 2008, Masha, Laser, Fiber, mach zehnder setup setup1.JPGsetup3.JPGsetup4.JPG
Entry  Tue Jul 29 00:58:36 2008, Masha, Laser, Fiber, first fiber noise measurement MZnoise_sources0727.png
Entry  Mon Jul 28 15:58:49 2008, Dmass, Computing, DAQ, Daq not recording 
    Reply  Fri Aug 1 14:52:27 2008, Dmass, Computing, DAQ, Daq not recording 
Entry  Fri Aug 1 15:06:11 2008, Dmass, Computing, CDS, ATF system 
    Reply  Tue Aug 5 15:23:38 2008, Dmass, Computing, CDS, ATF system 
    Reply  Mon Aug 11 14:15:57 2008, Dmass, Computing, CDS, ATF system 
Entry  Mon Aug 11 15:32:00 2008, Stefan Ballmer, Electronics, General, no DAC output voltage when running OMS didgital system 
    Reply  Fri Aug 15 02:17:46 2008, Dmass, Electronics, General, no DAC output voltage when running OMS didgital system 
Entry  Fri Aug 15 15:59:07 2008, Dmass, Computing, DAQ, DAC DAQ and ADC working 
Entry  Mon Aug 18 23:46:42 2008, Dmass, Computing, DAQ, More on the DAQ 
Entry  Wed Aug 20 23:19:39 2008, Dmass, Laser, Doubling, Preliminary Doubling MZ Setup MachZenderPPKTP.PNG
Entry  Tue Sep 2 11:01:00 2008, Aidan, Electronics, Fiber, Fiber stabilization loop diagram masha_layout_elec.png
Entry  Tue Sep 2 15:06:42 2008, Aidan, Laser, Fiber, Attempted calibration of fiber noise ... issues! peak_peak_calibration.pdf
    Reply  Tue Sep 2 23:09:38 2008, Aidan, Laser, Fiber, Attempted calibration of fiber noise. NPRO current = 1.903A peak_peak_calibration_1903mA.eps
    Reply  Wed Sep 3 16:43:56 2008, Aidan, Bram, Laser, Fiber, Fringe visibility fluctuation ... Bram's suggestions 
Entry  Wed Sep 3 13:35:56 2008, Aidan, Laser, Fiber, Calibrated noise spectra ... does not agree with previous measurements noise_calibrated_080902.jpgnoise_calibrated_080902.eps
    Reply  Wed Sep 3 18:22:20 2008, Aidan, Laser, Fiber, Calibrated noise spectra ... does not agree with previous measurements 
Entry  Tue Sep 9 15:49:22 2008, Dmass, Lab Infrastructure, HVAC, HEPA Filters 
Entry  Tue Sep 2 22:48:47 2008, Dmass, Laser, PSL, Connectors needed connectors.png
    Reply  Fri Sep 5 03:24:37 2008, Dmass, Laser, PSL, Connectors needed 
       Reply  Tue Sep 9 16:36:01 2008, Dmass, Laser, PSL, Connectors needed 
          Reply  Tue Sep 16 22:55:30 2008, Dmass, Laser, PSL, Connectors needed 
Entry  Fri Sep 19 13:18:00 2008, Dmass, Laser, PSL, Chiller on. 35W on. 
    Reply  Sun Sep 21 15:45:21 2008, Dmass, Laser, PSL, Chiller on. 35W on. Chiller_Back.png
Entry  Mon Sep 22 18:03:34 2008, Dmass, Computing, DAQ, DAQ IS BACK - as is the 35W 
Entry  Mon Sep 22 20:20:25 2008, Aidan, Laser, Fiber, Fringe magnitude fluctuation investigation fiber_coupler_rotation_angle_output_fluctuation.jpg00003.jpg
    Reply  Tue Sep 23 10:15:15 2008, Aidan, Laser, Fiber, Fringe magnitude fluctuation investigation - why isn' the maximum 45 degrees from the minimum? 
Entry  Tue Sep 23 12:10:08 2008, Aidan, Laser, Fiber, Maximized fiber coupler ROLL angle. 
Entry  Thu Oct 9 08:47:54 2008, Aidan, Laser, Fiber, Dismantled fiber stabilization setup 
Entry  Wed Oct 8 13:40:02 2008, Dmass, Laser, PSL, Chiller Noise 
    Reply  Sat Nov 8 21:38:17 2008, Dmass, Laser, PSL, Chiller Noise 
Entry  Tue Nov 25 17:30:32 2008, Aidan, Laser, Fiber, Preliminary noise budgets for fibre stabilization simulation_v1B.jpgphaseNoiseBudget-NPRO-PDA255.pdffreqNoiseBudget-NPRO-PDA255.pdf
Entry  Thu Jan 8 19:59:50 2009, Aidan, Misc, General, Earthquake ... 
Entry  Tue Nov 25 17:12:01 2008, Aidan, Things to Buy, Fiber, Residual things to buy for FS adhikari_lab_v1C.jpg
    Reply  Wed Jan 14 11:33:58 2009, Aidan, Things to Buy, Fiber, Residual things to buy for FS - QWPs, HWPs, output coupler 
       Reply  Wed Jan 14 18:14:23 2009, Aidan, Things to Buy, Fiber, Residual things to buy for FS - extra photodiodes 
Entry  Fri Jan 23 16:48:29 2009, Dmass, Laser, PSL, Chiller noise and DeI water 
Entry  Wed Mar 4 15:20:14 2009, pking, Laser, PSL, laser re-aligned 
Entry  Thu Mar 5 19:24:06 2009, ken mailand, Laser, General, 35 watt table beam dump Vertical_Test_Beam_Dump_Heat_Sink.jpg32_watt_test.jpgBeam_Dump_Assem_.jpgBeam_Dump_Assem_.pdf
Entry  Thu Apr 9 09:52:54 2009, alastair, Lab Infrastructure, DAQ, DAQ up and running model1.pngmodel2.png
Entry  Thu Apr 9 10:02:24 2009, alastair, Lab Infrastructure, General, Audio/mp3 
Entry  Fri Apr 17 20:05:59 2009, Aidan, Lab Infrastructure, General, Another workbench and a filing cabinet 
Entry  Sun Apr 19 16:01:35 2009, dmass, Laser, PSL, Laser On 
Entry  Sun Apr 19 16:08:03 2009, dmass, Laser, PSL, The chiller wants new filters 
Entry  Thu Apr 9 11:26:21 2009, alastair, Computing, DAQ, DAC now working 
    Reply  Fri Apr 17 20:04:17 2009, dmass, Computing, DAQ, ADC no longer working! 
       Reply  Mon Apr 20 18:03:44 2009, dmass, Computing, DAQ, ADC no longer working! 
Entry  Wed Apr 22 11:33:24 2009, Dmass, Computing, DAQ, DAQ back up and running 
    Reply  Wed Apr 22 14:47:47 2009, Dmass, Computing, DAQ, DAQ back up and running 
Entry  Thu Apr 23 15:25:35 2009, Dmass, Computing, DAQ, ATF Screens/DAQ up and running. 
    Reply  Sat Apr 25 12:11:54 2009, rana, Computing, DAQ, ATF Screens/DAQ up and running. 
Entry  Fri May 1 16:39:12 2009, Aidan, Computing, CDS, RCG make screwiness - how do i clean up old and failed makes? 
    Reply  Tue May 5 14:43:05 2009, Aidan, Computing, CDS, RCG make screwiness - how do i clean up old and failed makes? 
Entry  Tue May 5 16:36:40 2009, Aidan, Computing, CDS, Realtime code generation (RCG) troubleshooting 
Entry  Wed May 13 17:13:29 2009, Dmass, Laser, PSL, Beam Scans afterPBS.bmp
Entry  Wed May 13 16:57:28 2009, Dmass, Laser, PMC, Relocking the PMC 
    Reply  Thu May 14 20:57:22 2009, rana, Laser, PMC, Relocking the PMC 
       Reply  Fri May 15 04:23:19 2009, Dmass, Laser, PMC, Relocking the PMC Pmclock.png
Entry  Fri May 15 17:32:30 2009, Aidan, Computing, Fiber, Started screen for Fiber Stabilization - and claiming CDS channels Screenshot-C2ATF_FS_CONTROL.adl.pngScreenshot-C2ATF_MASTER.adl.png
Entry  Fri May 15 14:13:18 2009, Dmass, Laser, Doubling, SHG Ovens shgoven.png
    Reply  Fri May 15 17:41:43 2009, Dmass, Laser, Doubling, SHG Ovens SmallFirstlight.png
Entry  Fri May 15 17:53:25 2009, Dmass, Laser, PSL, Chiller making funny noises 
Entry  Fri May 15 18:27:01 2009, Dmass, Laser, PMC, New table layout for PMC NewLayout.pngNewLayout2.png
Entry  Sat May 23 16:04:57 2009, Aidan, Laser, Fiber, Blocking out FS experiment ... Table_Layout_v1.0.jpgphoto.jpgphoto1.jpg
Entry  Sat May 23 17:19:08 2009, Aidan, Things to Buy, General, Clamps, pedestals, mirror mounts, photodiodes 
Entry  Sat May 23 17:22:58 2009, Aidan, Laser, Fiber, FS expt is blocked out 
    Reply  Sat May 23 17:39:46 2009, Aidan, Laser, Fiber, FS expt is blocked out 
Entry  Mon May 25 16:31:36 2009, Aidan, Laser, Fiber, Photo of FS setup photo5.jpg
Entry  Mon Jun 1 15:59:42 2009, Dmass, Laser, PSL, Chiller Almost Empty 
Entry  Tue Jun 23 19:16:53 2009, Michelle Stephens, Connor Mooney, Laser, Fiber, Calibration of FS NPRO output power vs drive current Power_output_for_Nd-YAG_Plot.pdf
Entry  Thu Jun 25 10:44:46 2009, Michelle, Misc, General, Weekly Summary 1 
Entry  Sat Jun 27 22:09:36 2009, Dmass, Laser, PSL, I did some things in lab, some of which were bad. 
Entry  Wed Jul 1 17:06:30 2009, MStephens, Misc, General, New Gyro Design and Week 2 Summary NewerGyroDesign.PNG
Entry  Wed Jul 1 15:34:26 2009, Connor Mooney, Misc, Fiber, Weekly Report 
    Reply  Wed Jul 1 16:37:33 2009, Connor Mooney, Misc, Fiber, Weekly Report 
       Reply  Thu Jul 2 15:37:57 2009, Aidan, Misc, Fiber, Weekly Report - query on previous reply 
Entry  Thu Jul 2 21:40:57 2009, Aidan, Connor, Computing, DAQ, Frame builder shenanigans 
Entry  Fri Jul 3 19:49:30 2009, Aidan, Computing, DAQ, DAQ Map medm screen - Connectors and Channel names C2ATF_DAQ_MAP.png
    Reply  Fri Jul 3 21:26:13 2009, Aidan, Computing, DAQ, DAQ Map medm screen - added channel frame acquisition status C2ATF_DAQ_MAP_v1.1.png
Entry  Sat Jul 4 12:42:06 2009, Aidan , Computing, DAQ, DAq Map screen complete - just need to work out how to generate it automatically now C2ATF_DAQ_MAP_v1.11.png
Entry  Mon Jul 6 15:31:07 2009, Aidan, Alastair, Misc, General, Equipment moved from 58C 
Entry  Mon Jul 6 16:59:47 2009, Michelle Stephens, Connor Mooney, Laser, , Power Output of 495 mW NPRO PowervCurrent495mW.pdf
Entry  Fri Jun 26 17:20:45 2009, Michelle Stephens, Connor Mooney, Laser, Fiber, NPRO beam width divergence measurements NPRObeamdiv.pdf
    Reply  Mon Jul 6 21:03:47 2009, Dmass, Laser, Fiber, NPRO beam width divergence measurements 
Entry  Tue Jul 7 09:26:48 2009, Aidan, Computing, DAQ, Frame builder not restarting ... 
    Reply  Tue Jul 7 15:16:35 2009, Aidan, Computing, DAQ, Frame builder not restarting ... fixed! 
Entry  Tue Jul 7 16:49:05 2009, Michelle Stephens, Connor Mooney, Laser, General, Noise Measurements 495mW_NPRO_Noise.pdfNPRONoise.m
Entry  Wed Jul 8 10:36:44 2009, Michelle, Misc, , Week 3 Update 
Entry  Wed Jul 8 10:46:58 2009, Connor, Misc, General, Weekly Report #3 
Entry  Wed Jul 8 17:29:46 2009, Connor Mooney, Michelle Stephens, Laser, Fiber, Beam Divergence of 495mW NPRO beamdiv495mW.pdf
Entry  Wed Jul 8 19:05:49 2009, Dmass, Laser, PSL, Mode Matching and the PMC PMCbeamwaist.pdf
    Reply  Thu Jul 9 02:24:07 2009, rana, Laser, PSL, Mode Matching and the PMC 
Entry  Thu Jul 9 10:45:16 2009, Aidan, Computing, DAQ, Alex's frame builder problem diagnosis ... 
Entry  Thu Jul 9 10:46:52 2009, Aidan, Computing, DAQ, Deleted old /frame/full directories and rebuilt directory structure ... 
Entry  Thu Jul 9 10:48:03 2009, Connor, Laser, Fiber, Beamscan for 1w NPRO 
Entry  Thu Jul 9 13:29:08 2009, Aidan, Computing, DAQ, More from Alex on frame builder disk being full 
Entry  Tue Jul 14 15:08:07 2009, Connor Mooney, Laser, PSL, Beam Divergence of PSL 
Entry  Mon Jul 13 13:59:19 2009, Michelle, Laser, General, NPRO acting up 
    Reply  Mon Jul 13 21:39:11 2009, Michelle, Laser, General, NPRO acting up 
    Reply  Wed Jul 15 10:47:55 2009, Michelle, Laser, General, NPRO acting up 
Entry  Wed Jul 15 12:36:17 2009, Connor Mooney, Misc, General, Weekly Report #4 
Entry  Wed Jul 15 14:40:44 2009, Michelle, Laser, , NPRO ... fixed? 
    Reply  Wed Jul 15 22:13:09 2009, rana, Laser, General, Gyro NPRO 
Entry  Thu Jul 16 23:21:40 2009, Dmass, Laser, PSL, PSL Diode Powers and temperatures 
Entry  Sun Jul 19 09:44:09 2009, Aidan, Computing, General, Aliases added for standard LIGO tools 
Entry  Wed Jul 15 16:05:53 2009, Dmass, Laser, PSL, PSL Realigned, now better 
    Reply  Thu Jul 16 17:46:41 2009, Dmass, Laser, PSL, PSL Realigned, now better 
    Reply  Tue Jul 21 02:09:45 2009, Dmass, Laser, PSL, PSL Realigned, now better PSLRealignment.png
Entry  Tue Jul 21 18:45:26 2009, Connor, Laser, Fiber, alignment of optics FSprelimsetup.jpg
Entry  Tue Jul 21 20:39:18 2009, Dmass, Laser, PSL, PSL Beam Scans VertPSLScan.pdfHorPSLScan.pdf
Entry  Thu Jul 16 04:59:38 2009, Dmass, Laser, PSL, Razor Blades! Photo_1.jpgPhoto_3.jpg
    Reply  Thu Jul 16 15:01:48 2009, Koji & Connor , Laser, PSL, Razor Blades! 
       Reply  Thu Jul 16 17:43:59 2009, Dmass, Laser, PSL, Razor Blades! 
          Reply  Mon Jul 20 23:19:49 2009, rana, Laser, PSL, Razor Blades! 
             Reply  Tue Jul 21 20:41:56 2009, Dmass, Laser, PSL, Razor Blades! 
    Reply  Fri Jul 17 15:39:31 2009, Dmass, Laser, PSL, Razor Blades! RazorScans.pdf
Entry  Wed Jul 22 09:43:53 2009, Connor, Misc, , Weekly Report #5 
Entry  Wed Jul 22 11:09:45 2009, Michelle, Misc, , Weekly Update 5 
Entry  Wed Jul 22 20:36:37 2009, Aidan, Connor, Laser, Fiber, Aligned beam into fiber ... mode-matching needs a little work 
Entry  Thu Jul 23 07:22:35 2009, Aidan, Computing, CDS, Checked out the 40m MEDM screens from SVN to /cvs/cds/caltech/medm/c1 
Entry  Thu Jul 23 07:33:41 2009, Aidan, Computing, CDS, Added C2 MEDM screens to 40m SVN. 
Entry  Thu Jul 23 13:14:03 2009, Aidan, Connor, Laser, Fiber, AOM Aligned, beam matched into fiber, pick off from beam splitter correct size FS_layout_2009_07_23.pngphoto.jpg
Entry  Thu Jul 23 16:55:24 2009, Aidan, Connor, Laser, Fiber, Fiber coupling dominance - 19% transmission. 
Entry  Fri Jul 24 16:59:10 2009, Connor, Laser, Fiber, 1W NPRO minimum extinction ratio ExtRatio1WNPRO.pdf
Entry  Thu Jul 23 16:31:28 2009, Michelle, Laser, , I've done some things in lab. 
    Reply  Fri Jul 24 19:00:37 2009, rana, Laser, , I've done some things in lab. 
Entry  Thu Jul 23 16:05:48 2009, Dmass, Laser, PSL, More Mode Matching OldMMSol.pdfMMSol500500.pdfMMSol1000400.pdf
    Reply  Mon Jul 27 17:57:55 2009, Dmass, Laser, PSL, More Mode Matching 
Entry  Tue Jul 28 18:30:29 2009, Connor, Laser, Fiber, FS Reference Beam Calibration Ref_Power_vs_HWP_Angle.pdf
Entry  Wed Jul 29 15:46:38 2009, Aidan, Connor, Laser, Fiber, Output from demodulated AC channel in FS expt - polarization not totally matched 2009-07-29_PD1_Demodulated_output.pdf
Entry  Wed Jul 29 16:39:00 2009, Aidan, Connor, Laser, Fiber, Interference signal setup for FS Single_Pass_Noise_Measurement_Setup.jpg
Entry  Wed Jul 29 16:57:26 2009, Aidan, Connor, Laser, Fiber, Current fiber electronic setup  FS_layout_2009_07_29.png
Entry  Wed Jul 29 18:04:54 2009, Aidan, Connor, Laser, Fiber, Noise Budget for Single-Pass Setup 2009-07-29_PD1_Demodulated_output_noise_budget.pdf
Entry  Wed Jul 29 19:59:15 2009, Aidan, Connor, Laser, Fiber, HWP inserted to match input polarization to fast axis of PM fiber 2009-07-29_wandering_polarization.pdf
Entry  Thu Jul 30 21:39:49 2009, Aidan, Connor, Laser, Fiber, FIber Input HWP set to 356.4 degrees. Fibre_Polarization_Matching_Input.jpgFibre_Polarization_Matching_Output.jpg
Entry  Fri Jul 31 12:27:19 2009, Aidan, Connor, Laser, Fiber, Adjusting angle of fiber-input-HWP to minimize fluctuations in the output 2009-07-31_matching_input_polarization.pdf
Entry  Fri Jul 31 01:12:41 2009, Dmass, Laser, PSL, ReReReLocking the PMC aaaaaand stuck. ErrSignal.png
    Reply  Fri Jul 31 14:38:51 2009, Dmass, Laser, PSL, ReReReLocking the PMC aaaaaand stuck. 
       Reply  Fri Jul 31 14:58:14 2009, Koji, Laser, PSL, ReReReLocking the PMC aaaaaand stuck. 
Entry  Sun Aug 2 22:41:23 2009, Dmass, Electronics, General, Photodiode Woes 
Entry  Sun Aug 2 17:01:45 2009, Dmass, Laser, PSL, PMC Locking woes 
    Reply  Sun Aug 2 22:43:44 2009, Dmass, Laser, PSL, PMC Locking woes 
Entry  Sun Aug 2 22:48:53 2009, Dmass, Laser, PSL, PMC Locked - 10% Transmission 
Entry  Mon Aug 3 21:23:46 2009, Aidan, Connor, Laser, Fiber, Success! Fiber noise suppression ... again (but not calibrated) 2009-08-03_noise_reduction.pdf
Entry  Mon Aug 3 17:32:52 2009, Dmass, Electronics, PMC, Blood Feud Over PMCTRANSLoopGains.pdfPMCTransLoopgains.jpg
    Reply  Mon Aug 3 22:41:26 2009, Dmass, Electronics, PMC, Blood Feud Over PMCTransGainsreal.jpg
Entry  Mon Aug 3 22:53:11 2009, Dmass, Laser, PMC, Photodiodes and Power meters - confusion 
Entry  Wed Jun 24 15:17:59 2009, Dmass, Computing, CDS, Nokia Wireless Device 
    Reply  Tue Aug 4 15:37:17 2009, Dmass, Computing, CDS, Nokia Wireless Device 
Entry  Tue Aug 4 15:46:46 2009, Dmass, Lab Infrastructure, HVAC, Temperature update 
Entry  Wed Aug 5 10:10:11 2009, Michelle, Misc, General, Weekly Update (7?) 
Entry  Wed Aug 5 15:14:55 2009, Dmass, Computing, CDS, AWG and TP now up 
Entry  Tue Aug 4 15:01:28 2009, Dmass, Computing, DAQ, Transfer Functions and DTT 
    Reply  Tue Aug 4 18:41:49 2009, Dmass, Computing, DAQ, Transfer Functions and DTT OMCOLTF2.jpg
       Reply  Tue Aug 4 19:33:47 2009, Koji, Computing, DAQ, Transfer Functions and DTT 
          Reply  Tue Aug 4 21:55:00 2009, Dmass, Computing, DAQ, Transfer Functions and DTT 
             Reply  Tue Aug 4 23:52:06 2009, Koji, Computing, DAQ, Transfer Functions and DTT Pages_from_ando_d.png
                Reply  Wed Aug 5 16:59:45 2009, Dmass, Computing, DAQ, Transfer Functions and DTT PMCOLTFSWEEP.jpg
Entry  Thu Aug 6 09:55:39 2009, Aidan, Computing, DAQ, And it all comes crashing down again ... 
Entry  Thu Aug 6 10:01:34 2009, Aidan, Connor, Laser, Fiber, Phase matching the RF and LO signals in the fiber stabilization ... wow, that helps. 
Entry  Thu Aug 6 16:35:34 2009, Dmass, Computing, DAQ, DAQ, Hard Drives, and Size 
    Reply  Fri Aug 7 02:06:34 2009, rana, Computing, DAQ, DAQ, Hard Drives, and Size 
Entry  Fri Aug 7 10:39:20 2009, Michelle, Lab Infrastructure, , Changing Lasers 
Entry  Fri Aug 7 17:40:30 2009, Dmass, Laser, PSL, EOM Impedance Matching 
    Reply  Sat Aug 8 09:26:09 2009, rana, Laser, PSL, EOM Impedance Matching 
       Reply  Mon Aug 10 04:14:02 2009, Dmass, Laser, PSL, EOM Impedance Matching EOMmeasurement.pngEOMRefls.pdfEOMRefls2.png
Entry  Mon Aug 10 08:43:22 2009, Aidan, Laser, Fiber, DC intensity noise measurement over the weekend 2009-08-10_two_day_DC_level.pdf
Entry  Mon Aug 10 19:32:54 2009, Aidan, Connor, Laser, Fiber, Calibrated fiber stabilized phase and freq. noise measurement 2009-08-10_phase_noise_measurement-presentation.pdf
Entry  Wed Jul 22 20:40:13 2009, Aidan, Lab Infrastructure, fubar, Filing cabinet lock engaged ... with no key 
    Reply  Mon Aug 10 20:14:11 2009, Aidan, Lab Infrastructure, fubar, Filing cabinet lock engaged ... with no key 
Entry  Mon Aug 10 20:33:17 2009, Aidan, Connor, Electronics, General, Power reflected from AOMs when driven off resonance power_reflected_from_AOMs.pdfpower_reflected_from_AOMs.png
Entry  Tue Aug 11 00:16:29 2009, Dmass, Electronics, EOM, Wenzel Gone (for now) Wenzel.JPG
Entry  Mon Aug 10 17:34:43 2009, Michelle, Laser, General, Working Beam Profiler 
    Reply  Tue Aug 11 12:52:09 2009, Koji, Laser, General, Working Beam Profiler astigmatic.png
Entry  Tue Aug 11 15:33:38 2009, Aidan, Electronics, General, Marconi Memory Settings 101 and 102 Memory_101.pngMemory_102.png
Entry  Tue Aug 11 16:38:25 2009, Aidan, Things to Buy, General, Ordered mixers, splitters, LPFs and HPFs 
Entry  Tue Aug 11 18:14:49 2009, Aidan, Misc, General, Hive of activity ... 00001.png
Entry  Tue Aug 11 18:59:34 2009, Michelle, Zach, Laser, General, Locked! 00002.jpg2.00001.jpg
Entry  Tue Aug 11 22:33:54 2009, Dmass, Laser, PMC, SR560 - Yoink 
Entry  Wed Aug 12 01:02:21 2009, Dmass, Laser, PMC, PMC Locked - loop more stable PMCerrtrans.jpgPMCSweep.pdf
    Reply  Wed Aug 12 02:03:33 2009, Dmass, Laser, PMC, PMC Locked - loop more stable 
       Reply  Wed Aug 12 03:27:45 2009, rana, Laser, General, PMC Locked - loop more stable 
          Reply  Wed Aug 12 03:42:35 2009, Dmass, Laser, General, PMC Locked - loop more stable 
Entry  Wed Aug 12 11:19:57 2009, Aidan, Things to Buy, General, New Focus Order pending ... 
    Reply  Wed Aug 12 14:12:22 2009, Aidan, Things to Buy, General, New Focus Order pending ... 
Entry  Wed Aug 12 19:09:33 2009, Aidan, Connor, Laser, Fiber, Increased 80MHz signal by realigning and increasing power to PDs 
    Reply  Wed Aug 12 19:24:37 2009, Aidan, Connor, Laser, Fiber, Increased 80MHz signal by realigning and increasing power to PDs 2009-08-12_realigned_MZ_spectra_broadband_noise.pdf
Entry  Thu Aug 13 03:31:12 2009, Dmass, Laser, Doubling, Alignment/optimization of PMC and oven 
Entry  Thu Aug 13 03:35:17 2009, Dmass, Laser, PSL, PSL On - Long measurement Running 
Entry  Thu Aug 13 19:37:59 2009, Dmass, Laser, Doubling, Phase Matching Curve Measured CrudePM.pdfCrudePM.png
    Reply  Thu Aug 13 20:46:37 2009, Koji, Misc, Doubling, Phase Matching Curve Measured darkside.jpg
Entry  Mon Aug 17 18:17:42 2009, Aidan, Connor, Laser, Fiber, High PD noise due to poor overlap at output of MZ interferometer 
Entry  Mon Aug 17 23:02:53 2009, Dmass, Laser, PMC, PMC Mode Matching = <click to see> 
Entry  Tue Aug 18 03:37:57 2009, Dmass, Computing, DAQ, fb0 not ok. 
Entry  Tue Aug 18 02:45:39 2009, Dmass, Electronics, General, Bad Scope? 
    Reply  Tue Aug 18 09:15:21 2009, Dmass, Electronics, General, Bad Scope? 
Entry  Tue Aug 18 08:50:56 2009, Aidan, Computing, DAQ, Overflows on DAQ channels Screenshot.pngScreenshot-3.png
    Reply  Tue Aug 18 14:08:43 2009, DMass, Computing, DAQ, Overflows on DAQ channels 
Entry  Tue Aug 18 17:49:52 2009, Aidan, Laser, Fiber, MZ beam overlap after tweaking alignment: better @ 9% but still low 
Entry  Wed Aug 19 09:42:38 2009, Aidan, Computing, DAQ, Overflows: PMC PZT output in the billions of counts ... burtrestore issue? Screenshot.png
    Reply  Wed Aug 19 11:20:03 2009, rob, Computing, DAQ, billions flower.png
Entry  Wed Aug 12 16:30:01 2009, Dmass, Computing, PMC, PMC Loop Changed PMCOLTF_Boost.pdfPMCTranErrBoost.pdf
    Reply  Wed Aug 19 11:27:59 2009, rob, Computing, PMC, PMC Loop Changed 
Entry  Fri Aug 21 11:10:57 2009, Zach, Alastair, Laser, General, Progress with triangular cavity 
Entry  Fri Aug 21 18:44:33 2009, Aidan, Lab Infrastructure, General, Marconi Memory Setting 103 - 80.0001MHz 
Entry  Fri Aug 21 18:47:42 2009, Zach, Laser, General, some more progress 
Entry  Sat Aug 22 21:04:28 2009, Aidan, Laser, Fiber, Closed Loop on Single Pass again - strange saturation at low freq.  2009-08-22_uncal_phase_matched_SR560.pdf
Entry  Sun Aug 23 12:37:54 2009, Aidan, Laser, Fiber, Low Freq Acoustic Noise source [50-200Hz] identified 2009-08-23_low_freq_acoustic_noise.pdf
Entry  Sun Aug 23 12:41:18 2009, Aidan, Misc, General, Lower lab temperature 3 degrees. Too warm in here. 
Entry  Sun Aug 23 18:21:32 2009, Aidan, Laser, DAQ, Whitening Filter for Fiber signals into DAQ FILT-AB1.zip
Entry  Wed Aug 26 01:05:27 2009, Zach, Laser, General, modifications with some success 
    Reply  Wed Aug 26 15:06:51 2009, rana, Laser, General, modifications with some success 
Entry  Thu Aug 27 20:00:59 2009, Alastair, Lab Infrastructure, stuff happens, Lenses 
    Reply  Thu Aug 27 21:40:20 2009, (not) Alastair, Lab Infrastructure, stuff happens, Lenses 
       Reply  Fri Aug 28 10:26:12 2009, Alastair, Lab Infrastructure, stuff happens, Lenses 
          Reply  Fri Aug 28 10:52:35 2009, Alastair, Lab Infrastructure, stuff happens, Lenses 
             Reply  Fri Aug 28 12:26:14 2009, Dmass, Lab Infrastructure, stuff happens, Lenses 
                Reply  Fri Aug 28 12:39:00 2009, Alastair, Lab Infrastructure, stuff happens, Lenses 
                   Reply  Fri Aug 28 13:04:13 2009, Dmass, Lab Infrastructure, Purchases, Bought some lens mounts 
Entry  Sat Aug 29 18:49:06 2009, Zach, Laser, General, Diagram/Pictures loop.png00004s.jpg00003s.jpg
Entry  Mon Aug 31 00:20:23 2009, Dmass, Things to Buy, Purchases, "Can we have a pool dad?" 
Entry  Mon Aug 31 10:17:15 2009, Dmass, Lab Infrastructure, HVAC, Smokey Flavor in Lab 
Entry  Mon Aug 31 14:11:16 2009, Dmass, Computing, DAQ, More Disrepair for the DAQ 
Entry  Thu Sep 3 18:06:17 2009, Alastair, Laser, GYRO, Locking & Feedback 
Entry  Fri Sep 4 15:33:12 2009, Frank, Computing, DAQ, DV doesn't work in "realtime"-mode  
Entry  Fri Sep 4 15:35:53 2009, Frank, Laser, DAQ, All laser channels online 
Entry  Fri Sep 4 17:49:30 2009, Alastair, Laser, GYRO, Feedback 
Entry  Fri Sep 4 15:49:11 2009, Frank, Laser, General, 35W laser - bad beam profile 
    Reply  Fri Sep 4 20:36:55 2009, Dmass, Laser, General, 35W laser - bad beam profile 
Entry  Fri Sep 4 20:57:02 2009, Alastair, Laser, GYRO, Feedback slow_feedback.jpg
Entry  Tue Sep 8 09:36:07 2009, Alastair, Electronics, GYRO, Slow feedback filter version 1 slow_filter_version_1.tif
Entry  Tue Sep 8 13:40:22 2009, Alastair, Electronics, GYRO, New filter transfer function slow_filter_version_2.tifslow_filter_version_2_bypass_resistor.tif
Entry  Wed Sep 9 14:08:51 2009, Alastair, Lab Infrastructure, General, Lens kit is lookin' good 00005.jpg4.00001.jpg
Entry  Mon Sep 14 17:31:31 2009, Zach, Laser, GYRO, DAQ it up 
Entry  Tue Sep 15 16:45:04 2009, Aidan, Electronics, Fiber, Effect of whitening filter on fiber stabilization out of loop PD 2009-09-15_Whitening_dewhitening.pdf
Entry  Tue Sep 15 13:30:02 2009, Aidan, Electronics, Fiber, Whitening Filter transfer function WHITE001.MATWHITE001.ASCWhitening_FIlter_-_SR785.pdf2009-09-15_Whitening_Filter_Fit.png
    Reply  Wed Sep 16 06:52:57 2009, Aidan, Electronics, Fiber, Whitening Filter transfer function 
Entry  Wed Sep 16 09:49:51 2009, Aidan, Electronics, Fiber, Open and closed loop fiber noise with wnd without whitening filter 2009-09-16_whitening_filter_open_closed_loop.pdf2009-09-16_whitening_open_closed_2x50KHz.jpg
Entry  Tue Sep 15 16:28:31 2009, Zach, Laser, GYRO, Drumroll please... 
    Reply  Tue Sep 15 23:14:19 2009, Koji, Laser, GYRO, Drumroll please... Pages_from_kawabe_d.pngPages_from_kawabe_d.pdf
    Reply  Tue Sep 15 23:37:33 2009, rana, Laser, GYRO, Drumroll please... 
       Reply  Wed Sep 16 09:58:46 2009, Zach, Laser, GYRO, Drumroll please... 
Entry  Wed Sep 16 12:09:21 2009, Frank, Laser, General, 35W laser - laser update 
Entry  Wed Sep 16 12:13:00 2009, Frank, Computing, DAQ, new FB disk space comming soon 
Entry  Wed Sep 16 12:20:51 2009, Frank, Lab Infrastructure, General, cleaning the lab 
Entry  Wed Sep 16 12:24:38 2009, Frank, Computing, DAQ, new workstation 
Entry  Wed Sep 16 17:15:59 2009, Aidan, Computing, Fiber, Whitening filter and noise spectra 2009-09-16_whitening_filter_open_closed_loop_electronics.pdf
Entry  Thu Sep 17 09:48:19 2009, Aidan, Laser, Fiber, Closed loop with DAQ. Success. Screenshot-1.png
Entry  Thu Sep 17 09:53:06 2009, Aidan, Lab Infrastructure, Purchases, Lighting for bench photo.jpg
Entry  Thu Sep 17 08:22:16 2009, Aidan, Laser, General, Chiller warning - DI cartridge needs changing Screenshot.png
    Reply  Thu Sep 17 14:46:29 2009, not Aidan, Laser, General, Chiller warning - DI cartridge needs changing 
Entry  Thu Sep 17 18:22:05 2009, Aidan, Computing, Fiber, Loop closed with DAQ. Script running overnight 
Entry  Thu Sep 17 21:14:20 2009, Frank, Laser, Pulser, first tests 
Entry  Thu Sep 17 15:43:20 2009, Zach, Laser, GYRO, Friends of the electron: help, please 
    Reply  Thu Sep 17 22:56:20 2009, Koji, Laser, GYRO, Friends of the electron: help, please 
       Reply  Fri Sep 18 09:40:27 2009, Zach, Laser, GYRO, Friends of the electron: help, please 
Entry  Thu Sep 17 16:14:36 2009, Aidan, Laser, Fiber, Yesterday's spectra with shot noise included 2009-09-16_whitening_filter_open_closed_loop_electronics_shot.pdf
    Reply  Thu Sep 17 18:35:09 2009, rana, Laser, Fiber, Yesterday's spectra with shot noise included 
       Reply  Fri Sep 18 16:07:15 2009, Aidan, Laser, Fiber, (nearly) Calibrated noise spectra through DAQ 2009-09-18_closed_loo_DAQ.pdf00001.png
Entry  Fri Sep 18 11:30:44 2009, Zach, Laser, GYRO, Open-loop transfer function open_loop_TF.png2.png3.png
    Reply  Fri Sep 18 13:42:24 2009, Koji, Laser, GYRO, Open-loop transfer function 
       Reply  Fri Sep 18 14:13:51 2009, Zach, Laser, GYRO, Open-loop transfer function 2bode.png3bode.png
          Reply  Fri Sep 18 15:04:22 2009, Koji, Laser, GYRO, Open-loop transfer function 
             Reply  Fri Sep 18 15:31:32 2009, Zach, Laser, GYRO, Open-loop transfer function 
                Reply  Fri Sep 18 16:36:54 2009, Koji, Laser, GYRO, Open-loop transfer function 
Entry  Fri Sep 18 20:39:57 2009, Frank, Laser, Pulser, setup with pockel cell doesn't work 
Entry  Fri Sep 18 20:44:07 2009, Frank, Laser, PMC, PMC now re-aligned 
Entry  Fri Sep 18 20:49:04 2009, Frank, Lab Infrastructure, General, new optical filters (ND and longpass) 
Entry  Mon Sep 21 23:10:40 2009, Frank, Computing, DAQ, network working again 
Entry  Tue Sep 22 14:45:51 2009, Aidan, Electronics, Fiber, DAQ transfer function - phase delay bit me as well DAQTFFS1.zip2009-09-22_DAQ_TF.png2009-09-22_DAQ_transfer_function.pdf
Entry  Wed Sep 23 12:43:47 2009, Frank, Lab Infrastructure, General, new beam analyzer 
Entry  Wed Sep 23 19:29:38 2009, Aidan, Electronics, Fiber, VCO and mixer transfer function - saturated. VCO1E5HZ.zip2009-09-23_VCO_transfer_function.png2009-09-23_VCO_transfer_function.pdf
Entry  Wed Sep 23 21:09:10 2009, Frank, Laser, PMC, new output coupler for 35W laser PMC path 
Entry  Wed Sep 23 21:19:23 2009, Frank, Computing, General, new network address space 
Entry  Fri Sep 25 21:30:14 2009, Frank, Laser, MOPA, laser power back to 30+W 
Entry  Sun Sep 27 18:48:33 2009, Dmass, Lab Infrastructure, General, New Noise Source! 
Entry  Sun Sep 27 21:37:41 2009, Dmass, Computing, DAQ, Hack @ DAQ 
    Reply  Mon Sep 28 17:43:47 2009, rob, Computing, DAQ, Hack @ DAQ 
Entry  Mon Sep 28 16:53:07 2009, Zach, Misc, General, AOMs  AFD-402.pngAOM703M.png
    Reply  Mon Sep 28 17:17:08 2009, Koji, Misc, General, AOMs  
       Reply  Mon Sep 28 17:56:42 2009, Zach, Misc, General, AOMs  
Entry  Mon Sep 28 20:40:53 2009, Aidan, Misc, stuff happens, Please do not leave the permanent marker by the whiteboard ... 
Entry  Tue Sep 29 00:29:08 2009, Dmass, Laser, PMC, PMC Loop Model PMC_OLTF_FotonModel.jpgPMCOLTF_DTT.jpgPMC_OLTF_FotonModel.jpg
Entry  Tue Sep 29 02:56:13 2009, Dmass, Computing, DAQ, DAQ VERY BROKEN 
    Reply  Tue Sep 29 18:02:20 2009, Dmass, Computing, DAQ, DAQ VERY BROKEN 
Entry  Wed Sep 30 11:55:45 2009, Zach, Laser, GYRO, PZT transfer function block_diagram_simple.pngA1_inferred.png
Entry  Wed Sep 30 19:15:20 2009, Dmass, Computing, DAQ, DAQ VERY NOT BROKEN 
Entry  Thu Oct 1 11:05:09 2009, Zach, Misc, General, Telemarketers 
Entry  Tue Oct 6 23:37:06 2009, Aidan, Lab Infrastructure, General, Enclosure and cable tray installation before.jpgafter.jpg
Entry  Wed Oct 7 00:05:17 2009, Aidan, Misc, Fiber, Intraaction 70 MHz AOM - photos aom1.jpgaom2.jpgaom3.jpgaom4.jpgaom5.jpg
Entry  Wed Oct 7 00:51:35 2009, Aidan, Laser, Fiber, AOM installed and running on far side of fiber 00001.jpg
    Reply  Wed Oct 7 01:14:26 2009, Aidan, Laser, Fiber, AOM installed and running on far side of fiber PBS.jpg
Entry  Wed Oct 7 02:47:41 2009, Aidan, Misc, stuff happens, Digital camera is in my office 
Entry  Wed Oct 7 22:00:43 2009, Aidan, Laser, Fiber, Beam profile of double-passed transmission from fiber. 2009-10-07_double_passed_fiber.PNG
Entry  Wed Oct 7 15:55:03 2009, Alex M, Laser, Fiber, FS layout FSdiagram.gif
    Reply  Wed Oct 7 22:04:49 2009, Aidan, Laser, Fiber, FS layout 
Entry  Fri Oct 9 20:05:12 2009, Frank, Computing, General, new monitors @ WS2 
Entry  Fri Oct 9 20:20:03 2009, Frank, Computing, General, matlab R2009b on WS2 
Entry  Fri Oct 9 20:33:21 2009, Frank, Misc, Purchases, optomechanics / small monitors / long BNC cables 
Entry  Sat Oct 10 00:44:36 2009, Aidan, Laser, Fiber, MZ phase/frequency noise MZ_phase_noise.pdf
Entry  Mon Oct 12 17:09:27 2009, Frank, Lab Infrastructure, General, environmental monitoring 
Entry  Wed Oct 7 21:54:47 2009, Frank, Computing, General, new, static IP address 
    Reply  Sun Oct 11 04:22:20 2009, rana, Computing, General, new, static IP address 
       Reply  Mon Oct 12 22:38:06 2009, rana, Computing, General, new, static IP address 
Entry  Tue Oct 13 18:15:49 2009, Frank, Misc, General, optomechanics now in stock 
Entry  Tue Oct 13 18:39:36 2009, Frank, Computing, General, firefox and java plugin 
Entry  Wed Oct 14 20:18:52 2009, Frank, Lab Infrastructure, General, BNC cables and patch panels 
Entry  Wed Oct 14 20:28:07 2009, Frank, Computing, DAQ, fileserver and network in the lab 
Entry  Thu Oct 15 10:34:22 2009, Frank, Computing, General, network changes AdhikariLab-network.jpgAdhikariLab-network.jpg
Entry  Wed Aug 19 15:11:42 2009, Frank, Computing, DAQ, laser data now online 
    Reply  Wed Oct 14 23:49:03 2009, rana, Computing, DAQ, laser data now online Untitled.pngUntitled.png
       Reply  Thu Oct 15 10:57:18 2009, Frank, Computing, DAQ, laser data now online 
Entry  Thu Oct 15 17:16:56 2009, Frank, Computing, DAQ, DAQ and network down the next couple of hours 
Entry  Thu Oct 15 20:48:02 2009, Frank, Computing, DAQ, network up again 
Entry  Fri Oct 16 14:28:51 2009, Zach, Laser, GYRO, Diagram gyro_diagram.png
Entry  Fri Oct 16 17:01:50 2009, Frank, Computing, General, network address changes done NOW 
Entry  Fri Oct 16 19:48:32 2009, Frank, Computing, General, network changed and up again 
Entry  Fri Oct 16 20:51:06 2009, Frank, Laser, General, 35W laser & DAQ up and running 
Entry  Sun Oct 18 19:17:20 2009, Frank, Computing, General, new network addresses AdhikariLab-network.jpg
Entry  Mon Oct 19 17:32:54 2009, Zach, Misc, GYRO, shot-noise-limited sensitivity shot_noise_calc.pdf
Entry  Tue Oct 20 18:14:06 2009, Frank, Misc, FSS, old refcav at 40m 
Entry  Tue Oct 20 18:21:41 2009, Frank, Lab Infrastructure, General, dirty air 
Entry  Tue Oct 20 20:06:04 2009, Frank, Computing, General, fileserver, home directories and new framebuilder 
Entry  Wed Oct 21 16:07:25 2009, Frank, Lab Infrastructure, General, new particle counter 
Entry  Wed Oct 21 18:35:54 2009, Frank, Lab Infrastructure, General, Environmental monitoring - first data envmon.PNG
Entry  Thu Oct 22 13:54:04 2009, Frank, Computing, DAQ, Newport opc license 
Entry  Thu Oct 22 17:11:41 2009, Frank, Lab Infrastructure, General, pictures of leaks 10x
Entry  Tue Oct 20 19:37:57 2009, Mott, Electronics, Fiber, Marconi Phase Noise MarconiG.jpgMarconiPSD_cor.jpgMarconiPhaseNoise_Cor.jpg
    Reply  Wed Oct 21 01:19:49 2009, Koji, Electronics, Fiber, Marconi Phase Noise 
       Reply  Wed Oct 21 16:10:57 2009, Mott, Electronics, Fiber, Marconi Phase Noise IsometVsMarconi_corr.jpg
          Reply  Wed Oct 21 20:45:12 2009, Koji, Electronics, Fiber, Marconi Phase Noise 
             Reply  Thu Oct 22 14:59:43 2009, Mott, Electronics, Fiber, Marconi Phase Noise IsometVsMarconi_corr.jpg
                Reply  Thu Oct 22 22:10:58 2009, Koji, Electronics, Fiber, Marconi Phase Noise 
Entry  Fri Oct 23 12:35:18 2009, Frank, Computing, DAQ, fb1 not working 
Entry  Fri Oct 23 16:48:32 2009, Frank, Computing, DAQ, fb1 now online 
Entry  Fri Oct 23 17:00:08 2009, Frank, Lab Infrastructure, General, environmental monitoring data now available 
    Reply  Sat Oct 24 05:04:13 2009, Frank, Lab Infrastructure, General, environmental monitoring data now available 
       Reply  Mon Oct 26 17:23:43 2009, Frank, Lab Infrastructure, General, environmental monitoring data now available 
          Reply  Wed Oct 28 08:00:20 2009, rana, Lab Infrastructure, General, environmental monitoring data now available 
Entry  Fri Oct 30 12:25:06 2009, Frank, Lab Infrastructure, DAQ, new PEM channels 
Entry  Fri Oct 30 13:02:53 2009, Frank, Computing, DAQ, FE hard drives replaced 
Entry  Fri Oct 30 19:41:31 2009, Frank, Laser, RefCav, reference cavity moved to ATF 8x
Entry  Fri Oct 30 21:08:49 2009, Frank, Computing, DAQ, disk space for frames 
Entry  Fri Oct 30 21:26:10 2009, Frank, Computing, General, updated network schematic Adhikari-lab-network_v2.1.jpg
Entry  Mon Nov 2 22:55:07 2009, Frank, Lab Infrastructure, General, custom made 35ft cables arrived 
Entry  Tue Nov 3 11:44:05 2009, Zach, Laser, GYRO, revised sensitivity calculation shot_noise_calc.pdf
    Reply  Tue Nov 3 22:21:40 2009, rana, Laser, GYRO, revised sensitivity calculation 
Entry  Wed Nov 4 17:49:17 2009, Mott, Electronics, Fiber, Plant Phase Noise Measurements for Fiber Stabilization PlantPhaseNoise.jpgPlantPhaseNoiseFreq.jpg
Entry  Wed Nov 4 18:36:44 2009, Frank, Lab Infrastructure, General, some AC leaks sealed 
Entry  Wed Nov 4 18:45:33 2009, Frank, Laser, RefCav, reference cavity replaced and locked 100_0351.JPG100_0345.JPG100_0348.JPG100_0344.JPG100_0350.JPG
Entry  Sat Nov 7 04:09:32 2009, Mott, Electronics, Fiber, NEOS Phase noise 
Entry  Sun Nov 8 14:10:06 2009, Frank, Lab Infrastructure, General, ATF particle counter - first data available AdhikariLab_data_091107_104657_new.jpg
Entry  Fri Nov 6 19:46:57 2009, Aidan, Laser, Fiber, VCO phase noise requirements for Fiber Stabilization VCO_requirements.pdfVCO_requirements.jpg
    Reply  Sun Nov 8 13:14:43 2009, Aidan, Laser, Fiber, Correction: VCO phase noise requirements for Fiber Stabilization FS_control_loop.pngFS_control_loop.pdf
       Reply  Sun Nov 8 14:23:46 2009, Aidan, Laser, Fiber, VCO as LO phase noise requirements for FS VCO_PN_requirement.pdfVCO_PN_requirement.png
          Reply  Mon Nov 9 10:36:04 2009, Aidan, Laser, Fiber, VCO as LO phase noise requirements for FS VCO_phase_noise_requirements.pngVCO_phase_noise_requirements.pdfVCO_freq_noise_requirements.pngVCO_freq_noise_requirements.pdf
Entry  Thu Nov 12 14:40:34 2009, Dmass, Computing, DAQ, 16 Hz comb in test points 
Entry  Fri Nov 13 14:37:11 2009, Mott, Electronics, Fiber, Isomet and Marconi Phase noise Datasets MarconiData.matIsometData.mat
Entry  Fri Nov 13 12:54:57 2009, Aidan, Computing, DAQ, Naming conventions ... 
    Reply  Fri Nov 13 15:11:40 2009, Jenne, Computing, DAQ, Naming conventions ... 
Entry  Fri Nov 13 20:23:28 2009, Aidan, Mott, Laser, Fiber, Double-passed fiber beam and the 20MHz beat 
    Reply  Sat Nov 14 18:23:05 2009, rana, Laser, Fiber, Double-passed fiber beam and the 20MHz beat 
       Reply  Sun Nov 15 13:50:48 2009, Aidan, Laser, Fiber, Frequency Counter: BK Precision 1856D 
Entry  Wed Nov 11 18:20:29 2009, Dmass, Laser, Doubling, Data 
    Reply  Thu Nov 12 08:54:51 2009, Dmass, Laser, Doubling, Data 
       Reply  Fri Nov 13 16:38:25 2009, Dmass, Laser, Doubling, Data test2.pdf
          Reply  Fri Nov 13 17:21:06 2009, Dmass, Laser, Doubling, Data MZPDNoiseCoh.pdf
             Reply  Sun Nov 15 14:21:41 2009, rana, Laser, Doubling, Data 
Entry  Mon Nov 16 11:33:16 2009, Aidan, Computing, DAQ, Unable to restart framebuilder ... 
    Reply  Mon Nov 16 11:50:27 2009, Aidan, Computing, DAQ, Unable to restart framebuilder ... 
       Reply  Tue Nov 17 12:13:23 2009, Frank, Computing, DAQ, Unable to restart framebuilder ... 
Entry  Tue Nov 17 12:17:33 2009, Aidan, Laser, Fiber, Beam propagation after partial reflector on far side of fiber 2009_11_17-beam_propagation_from_PRR.pdf
    Reply  Tue Nov 17 16:27:17 2009, Aidan, Laser, Fiber, Added cylindrical lenses to fiber transmission 2009_11_17-beam_propagation_from_PRR_post_cylindrical.pdf
Entry  Tue Nov 17 18:46:36 2009, Aidan, Laser, Fiber, Heterodyne beat on far side of fiber 
Entry  Mon Nov 9 16:57:30 2009, Dmass, Laser, Doubling, Doubling Noise Experiment MZ1.pngMZ2.png
    Reply  Wed Nov 11 15:51:30 2009, Dmass, Laser, Doubling, Doubling Noise Experiment 
    Reply  Tue Nov 17 15:00:27 2009, Dmass, Laser, Doubling, Doubling Noise Experiment 
       Reply  Tue Nov 17 21:48:26 2009, Dmass, Laser, Doubling, Doubling Noise Experiment Arm1blocked.pdfArm2blocked.pdfBeamblocked.pdf
          Reply  Tue Nov 17 22:34:39 2009, Koji, Laser, Doubling, Doubling Noise Experiment 
Entry  Thu Nov 19 16:06:09 2009, Alberto, Computing, General, Elog debugging output - Down time programmed today to make changes 
    Reply  Thu Nov 19 18:50:22 2009, Alberto, Computing, General, Elog debugging output - Down time programmed today to make changes 
Entry  Thu Nov 19 21:36:19 2009, Dmass, Laser, Doubling, Doubling Noise List 
Entry  Wed Nov 18 21:08:41 2009, Aidan, Mott, Laser, Fiber, Out of loop measurement of stabilized fiber phase noise 2009_11_18-double-passed-fiber-initial.pdf
    Reply  Thu Nov 19 10:20:52 2009, rana, Laser, Fiber, Out of loop measurement of stabilized fiber phase noise 
       Reply  Fri Nov 20 10:59:29 2009, Aidan, Laser, Fiber, Out of loop measurement of stabilized fiber phase noise 
Entry  Mon Nov 23 14:28:51 2009, Mott, Computing, General, slight change to network topology 
Entry  Mon Nov 23 15:50:07 2009, Mott, Computing, General, slight change to network topology 
Entry  Sat Nov 21 16:03:58 2009, Frank, Computing, DAQ, FE error messages 100_0370.JPG
    Reply  Sat Nov 21 17:52:27 2009, Koji, Computing, DAQ, FE error messages 
       Reply  Mon Nov 23 17:01:01 2009, Frank, Computing, DAQ, FE error messages 
Entry  Tue Dec 1 01:59:22 2009, Zach, Laser, GYRO, Gyro noise budget stage-1_sample_budget.pngstage_1_model.zip
Entry  Wed Dec 2 14:04:50 2009, Zach, Laser, GYRO, Gyro diagram diagram.png
Entry  Tue Dec 1 19:41:45 2009, Dmass, Laser, Doubling, Doubling Crystal Side1.pngSide2.png
    Reply  Thu Dec 3 00:00:31 2009, Dmass, Laser, Doubling, Doubling Crystal 
       Reply  Thu Dec 3 15:20:31 2009, Dmass, Laser, Doubling, Doubling Crystal 
Entry  Fri Dec 4 16:15:12 2009, Dmass, Lab Infrastructure, General, Isopropyl 
Entry  Mon Dec 7 17:15:56 2009, Dmass, Laser, Doubling, Crystal OK? 
Entry  Mon Dec 7 14:01:18 2009, Aidan, Computing, fubar, Front-end is down ... 
    Reply  Mon Dec 7 17:18:40 2009, Aidan, Computing, DAQ, Front-end is back up (Alex's comments) 
Entry  Tue Dec 8 15:33:49 2009, Frank, Lab Infrastructure, General, ATF particle counts AdhikariLab_data_191107.jpg
Entry  Wed Dec 9 00:45:31 2009, Dmass, Laser, Doubling, Realigned the MZ 
Entry  Wed Dec 9 11:53:42 2009, Frank, Laser, stuff happens, laser data unavailable since 1 week 
Entry  Wed Dec 9 16:25:19 2009, Dmass, Laser, Doubling, PD Reflections 
Entry  Wed Dec 9 16:39:34 2009, Dmass, Laser, Doubling, Contrast Data... 
Entry  Fri Dec 11 19:13:59 2009, Zach, Laser, GYRO, Carrier HOM resonances in gyro HOM_res_R6m.png
Entry  Fri Dec 11 19:33:54 2009, Frank, Computing, DAQ, Beckhoff (Laser) channel to EPICS channel translation moved to 10.0.1.12 
Entry  Sat Dec 12 23:38:47 2009, Dmass, Laser, Doubling, Pictures! Box and Setup CleanerMZ.pngOutputPrebox.pngBoxPics.png
Entry  Mon Dec 14 10:54:35 2009, Frank, Laser, PSL, medm screens available  
Entry  Tue Dec 15 02:43:25 2009, rana, Electronics, GYRO, Noise of the 80 MHz RFPD for the transmitted port rfpd.pdf
Entry  Mon Dec 14 11:46:04 2009, Zach, Laser, GYRO, Carrier HOM resonance comparison carrier_HOM.pdf
    Reply  Tue Dec 15 03:07:24 2009, rana, Laser, GYRO, Carrier HOM resonance comparison 
       Reply  Tue Dec 15 11:08:30 2009, Zach, Laser, GYRO, Carrier HOM resonance comparison 
Entry  Wed Dec 16 15:04:20 2009, Zach, Lab Infrastructure, GYRO, Turf Wars HOM_c_4m_90MHz.pngHOM_c_6m_90MHz.png
    Reply  Wed Dec 16 16:43:25 2009, rana, Lab Infrastructure, GYRO, Turf Wars 
       Reply  Wed Dec 16 16:56:19 2009, Zach, Lab Infrastructure, GYRO, Turf Wars HOM_c_9m_90MHz.png
Entry  Sat Dec 12 17:42:23 2009, Dmass, Laser, Doubling, Mach Zehnder BOXED Spectrum MZBoxedPDSpec.jpgBoxedMZPDSpec.pdf
    Reply  Sat Dec 12 22:54:03 2009, Dmass, Laser, Doubling, Mach Zehnder BOXED Spectrum MZNoiseACALL.jpgMZNoisesAllAC.pdfAC_Couple_hydra.png
       Reply  Mon Dec 14 18:58:41 2009, Dmass, Laser, Doubling, Mach Zehnder BOXED Spectrum 
       Reply  Tue Dec 15 02:35:35 2009, Dmass, Laser, Doubling, Mach Zehnder BOXED Spectrum AC1fit.pdfAC2fit.pdfAC3fit.pdfAC4fit.pdf
          Reply  Tue Dec 15 06:25:32 2009, rana, Laser, Doubling, fitting and combining the streams 
             Reply  Tue Dec 15 18:37:55 2009, Dmass, Laser, Doubling, fitting and combining the streams 
                Reply  Wed Dec 16 22:45:03 2009, Dmass, Laser, Doubling, fitting and combining the streams 
Entry  Sat Dec 12 18:02:47 2009, Dmass, Computing, DAQ, framebuilding funniness 
    Reply  Thu Dec 17 19:52:22 2009, Aidan, Computing, DAQ, framebuilding funniness - "hold please" 
       Reply  Thu Dec 17 20:40:35 2009, Aidan, Computing, DAQ, Restarting DAQ - something else to avoid 
Entry  Thu Dec 17 23:49:38 2009, Dmass, Computing, DAQ, Rebuilt ATF.mdl, added channel 
Entry  Fri Dec 18 01:00:00 2009, Dmass, Laser, Doubling, Confusion Abounds MZCrossoverandCoh.pdfACCoupleTF.pdf
    Reply  Fri Dec 18 06:57:30 2009, rana, Laser, Doubling, Confusion Abounds ^2 
       Reply  Fri Dec 18 13:27:12 2009, Dmass, Laser, Doubling, Confusion Abounds ^3 MZACCoupTFALL.pdf
          Reply  Fri Dec 18 15:42:22 2009, Dmass, Laser, Doubling, Confusion Abounds ^3 
Entry  Fri Dec 18 19:11:17 2009, rana, Things to Buy, GYRO, Test of the G&H HR mirrors from MIT GnH.pdf
    Reply  Fri Dec 18 22:38:25 2009, Koji, Things to Buy, GYRO, Test of the G&H HR mirrors from MIT 
Entry  Mon Dec 21 20:43:15 2009, Zach, Laser, GYRO, SB frequency SB_7p5MHz.pngSB_23MHz.png
    Reply  Tue Dec 22 00:14:23 2009, Koji, Laser, GYRO, SB frequency 
    Reply  Wed Dec 23 12:07:52 2009, rana, Laser, GYRO, SB frequency 
       Reply  Wed Dec 23 19:46:25 2009, Zach, Laser, GYRO, SB frequency 
          Reply  Sun Dec 27 23:47:34 2009, rana?, Laser, GYRO, SB frequency 
             Reply  Mon Dec 28 08:21:55 2009, Zach, Laser, GYRO, SB frequency 
Entry  Mon Dec 28 16:20:34 2009, Frank, Computing, DAQ, booting VME crates from fb1 
Entry  Mon Dec 28 23:26:55 2009, Frank, Misc, General, how projects function HowProjectsFunction.jpg
Entry  Tue Dec 29 05:33:25 2009, rana, Things to Buy, GYRO, What Mounts to Use for the Gyro? sn100-f2k.jpgSL51BCH.jpg
    Reply  Tue Dec 29 18:27:41 2009, Frank, Things to Buy, GYRO, What Mounts to Use for the Gyro? 
       Reply  Mon Jan 4 16:05:12 2010, Alastair, Things to Buy, GYRO, What Mounts to Use for the Gyro? 
Entry  Thu Jan 7 11:04:16 2010, Zach, Laser, GYRO, Modulator impedance spectra AOM.pngAOM.pngEOM.png
Entry  Thu Jan 7 17:27:04 2010, Zach, Lab Infrastructure, fubar, tip of the iceberg 00001.jpg
Entry  Sun Jan 10 20:01:41 2010, Dmass, Computing, DAQ, Problems with transfer functions 
Entry  Mon Jan 11 15:05:29 2010, Zach, Laser, GYRO, SB frequency (with FSR = 95 MHz) sb_26MHz_FSR95.png
Entry  Mon Jan 11 20:18:46 2010, Zach, Laser, GYRO, oldskool plot sb_26MHz_FSR95_oldskool.pngsb_26MHz_FSR95.png
Entry  Mon Jan 11 21:17:34 2010, Zach, Laser, GYRO, oldskool plot 2.0 sb_26MHz_FSR95_oldskool_full_FSR.png
Entry  Tue Jan 12 00:47:42 2010, Dmass, Laser, PSL, Calibration Lines added 
Entry  Tue Jan 12 02:33:15 2010, Dmass, Laser, Doubling, Craziness! 
Entry  Thu Jan 14 01:53:11 2010, Dmass, Computing, DAQ, DAQ Changes 
Entry  Thu Jan 14 02:01:43 2010, Dmass, Computing, DAQ, Optimal Filters ACCoupRecomboTF.pdf
    Reply  Thu Jan 14 14:52:44 2010, Dmass, Computing, DAQ, Optimal Filters 
Entry  Thu Jan 14 18:08:50 2010, Dmass, Laser, Doubling, Note to Self 
Entry  Fri Jan 15 16:46:14 2010, Frank, Computing, General, monitor utility medm.xwd1263602599.ps
Entry  Sat Jan 16 23:16:45 2010, Aidan, Computing, DAQ, Restarted front end ... and then it broke 
Entry  Thu Jan 14 12:16:35 2010, Alastair, Misc, Purchases, Parts for the Gyro 
    Reply  Sun Jan 17 05:26:46 2010, rana, Misc, Purchases, Parts for the Gyro 
Entry  Mon Jan 18 17:53:13 2010, Aidan, Computing, DAQ, Front end restarted - "burtrestore = 1" was the trick 
Entry  Tue Jan 19 09:17:09 2010, Aidan, Computing, DAQ, New fiber channels in frame 
Entry  Tue Jan 19 09:18:47 2010, Aidan, Laser, Fiber, Double passed stabilization - mark II 2010-01-19_loop_closed_times_series_good.pdf
    Reply  Tue Jan 19 18:16:53 2010, Aidan, Laser, Fiber, Double passed stabilization - mark II - hmmm 
Entry  Thu Jan 21 19:03:24 2010, Dmass, Laser, Doubling, Spectra for MZ 10aMZLengthSpec.pdf11aMZPhaseSpec.pdf12aMZPhase.pdf14a_cohere.pdf
Entry  Fri Jan 22 11:09:45 2010, Aidan, Laser, Fiber, Whitening filter and RF spectra data FS_20M_3.zip
Entry  Thu Jan 21 23:02:36 2010, Aidan, Laser, Fiber, Characterizing fiber stabilization measurement - sidebands and mode-matching 
    Reply  Fri Jan 22 15:08:50 2010, Aidan, Laser, Fiber, Characterizing fiber stabilization measurement - sidebands and mode-matching RF_signals_with_sidebands.png
Entry  Fri Jan 22 11:59:57 2010, Aidan, Laser, Fiber, Whitening filter in Pomona box data from SR785 SCRN0007.TXTSCRN0008.TXT
    Reply  Fri Jan 22 15:10:35 2010, Aidan, Laser, Fiber, Whitening filter in Pomona box data from SR785 pomona_box_WF_transfer_fn.png
Entry  Mon Jan 25 11:35:15 2010, Aidan, Laser, Fiber, Fiber layout - before dismantling FS_table_layout_JAN_2010.pdfFS_table_layout_JAN_2010.jpg
Entry  Tue Jan 26 00:18:38 2010, Dmass, Laser, Doubling, Decimate Confusion 
Entry  Tue Jan 26 10:01:03 2010, Zach, Laser, GYRO, alignment/locking 
Entry  Tue Jan 26 11:00:45 2010, Aidan, Laser, Fiber, Fiber stabilization loop transfer function measurements & calculation SCRN0012.zipFS__measured_transfer_fn.pdf
Entry  Tue Jan 26 13:52:44 2010, Aidan, Laser, Fiber, Fiber setup - voltages and power levels throughout the experiment 
Entry  Tue Jan 26 15:57:01 2010, Aidan, Laser, Fiber, FS - phase noise measurements 2010-01-22_fiber_stabilization_phase_noise.pdf
Entry  Tue Jan 26 16:55:50 2010, Zach, Laser, GYRO, new short-term setup HOM_R6m_33MHz.png
Entry  Wed Jan 27 21:12:03 2010, Alastair, Laser, GYRO, Cavity alignment 
Entry  Thu Jan 28 09:18:24 2010, Alastair, Laser, GYRO, Beam scan of Gyro Npro beamscan01_28.jpg
    Reply  Thu Jan 28 16:52:21 2010, Koji, Laser, GYRO, Beam scan of Gyro Npro 
Entry  Thu Jan 28 21:08:27 2010, Dmass, Computing, DAQ, PD Trend Confusion... confused.pdf
Entry  Thu Jan 28 18:56:00 2010, Zach, Laser, GYRO, Gyro cavity LOCKED lock_woot.jpggyro_1D_diagram.jpg
    Reply  Thu Jan 28 23:29:30 2010, rana, Laser, GYRO, Gyro cavity LOCKED 
Entry  Tue Jan 26 00:38:21 2010, Dmass, Laser, Doubling, Calibrated Mach Zehnder Spectra etc 11x
    Reply  Tue Jan 26 01:07:06 2010, Dmass, Laser, Doubling, Calibrated Mach Zehnder Spectra etc 11b1Cancellation.pdf
       Reply  Tue Jan 26 03:24:58 2010, rana, Laser, Doubling, Calibrated Mach Zehnder Spectra etc 
          Reply  Tue Jan 26 18:44:31 2010, Dmass, Laser, Doubling, Calibrated Mach Zehnder Spectra etc 10b1Subtraction.pdf
             Reply  Thu Jan 28 22:57:22 2010, Dmass, Laser, Doubling, Calibrated Mach Zehnder Spectra etc 18b1MZPhaseSpec.pdf18b1MZFreqSpec.pdf
                Reply  Fri Jan 29 01:32:05 2010, rana, Laser, Doubling, Calibrated Mach Zehnder Spectra etc mzspectra.pngmzfilters.png
Entry  Fri Jan 29 17:53:03 2010, Dmass, Computing, fubar, Mental Computing Broken 
Entry  Sat Jan 30 04:13:53 2010, Dmass, Computing, Doubling, Frequency Domain Subtraction 19b1MZSubtrFreqDom.pdf
Entry  Mon Feb 1 12:10:52 2010, Dmass, Laser, Doubling, Data Time Stamps 
Entry  Tue Feb 2 09:47:28 2010, Zach, Laser, GYRO, gyro update and TF OLTF.png
    Reply  Tue Feb 2 11:00:03 2010, rana, Laser, GYRO, gyro update and TF 
       Reply  Tue Feb 2 14:33:41 2010, Zach, Laser, GYRO, gyro update and TF OLTF_10Hz-100kHz.png
Entry  Tue Feb 2 18:13:26 2010, Zach, Laser, GYRO, Gyro servo signal spectra signal_spectra.png
Entry  Wed Feb 3 03:06:23 2010, Dmass, Computing, DAQ, NDS server down? 
Entry  Wed Feb 3 17:15:12 2010, Dmass, Computing, DAQ, NDS INFO FOR NOT THE 40m 
Entry  Thu Feb 4 00:59:23 2010, rana, Computing, fubar, ELOG restarted: no more .ps files 
Entry  Thu Feb 4 10:22:41 2010, Zach, Lab Infrastructure, General, USB floppy drive missing 
Entry  Thu Feb 4 12:00:08 2010, Zach, Laser, GYRO, Cavity finesse and HR mirror transmission measurement 
Entry  Fri Feb 5 17:42:00 2010, Dmass, Laser, Doubling, PD Noise Spectra 6x
    Reply  Sat Feb 6 18:20:18 2010, Dmass, Laser, Doubling, PD Noise Spectra 
Entry  Mon Feb 8 19:54:08 2010, Alastair, Laser, GYRO, locked in one direction 
Entry  Mon Feb 8 10:40:52 2010, Zach, Lab Infrastructure, General, Where is stuff 
    Reply  Mon Feb 8 11:49:28 2010, rana, Lab Infrastructure, General, Where is stuff 
       Reply  Tue Feb 9 01:01:20 2010, dmass, Lab Infrastructure, General, Where is stuff 
Entry  Tue Feb 9 17:03:48 2010, Frank, Misc, General, Marconi missing 
    Reply  Tue Feb 9 17:28:24 2010, Alberto, Misc, General, Marconi missing 
       Reply  Tue Feb 9 17:55:17 2010, Alberto, Misc, General, Marconi missing 
Entry  Tue Feb 9 23:27:45 2010, Dmass, Lab Infrastructure, Optics, Window Fun 
Entry  Tue Feb 9 17:58:15 2010, Zach, Laser, GYRO, Gyro cavity locked in other direction lock_shot_small.jpginput_diagram_small.jpg
    Reply  Wed Feb 10 08:27:08 2010, rana, Laser, GYRO, Fisheye 
Entry  Tue Feb 9 01:55:37 2010, Dmass, Laser, Doubling, Noise Spectra (Done) 6x
    Reply  Tue Feb 9 16:23:51 2010, Dmass, Laser, Doubling, Noise Spectra (Done) SUBPhaseNoiseSpec.pdfMZPhaseSubPlot.pdf
       Reply  Wed Feb 10 08:29:38 2010, rana, Laser, Doubling, Noise Spectra (Done) 
Entry  Thu Feb 11 15:19:44 2010, Mott, Laser, Fiber, Fiber Mach-Zehnder 
Entry  Thu Feb 11 16:40:27 2010, Alastair, Laser, GYRO, More stuff for gyro 
Entry  Tue Feb 16 03:32:58 2010, dmass, Computing, Doubling, Matlab MZ Subtraction Code Update 
Entry  Tue Feb 16 11:39:38 2010, Frank, Computing, General, fb0 error 
Entry  Tue Feb 16 13:21:08 2010, Alastair, Laser, GYRO, Beam scan for AOM double pass 10_02_16_beamscan_for_AOM.jpg10_02_16_beam_pre_AOM.txtScreen_shot_2010-02-16_at_1.34.37_PM.png
Entry  Tue Feb 16 16:54:58 2010, Alastair, Laser, GYRO, Curved mirror for AOM 
Entry  Tue Feb 16 19:28:25 2010, Frank, Computing, General, fb0 is now working again 
    Reply  Wed Feb 17 01:27:24 2010, Frank, Computing, General, fb0 is now working again 
Entry  Wed Feb 17 03:40:10 2010, Dmass, Computing, Doubling, MATLAB MZ SUBTRACTION CODE MZ_Code_Diagram.png
    Reply  Sat Feb 13 13:29:22 2010, Koji, Computing, Doubling, MATLAB MZ SUBTRACTION CODE 
       Reply  Sun Feb 14 04:31:09 2010, Dmass, Computing, Doubling, MATLAB MZ SUBTRACTION CODE 
Entry  Thu Feb 11 19:07:09 2010, Dmass, Laser, Doubling, Intensity Noise Measurement, and Coherence MZPDCoherence.pdf
    Reply  Wed Feb 17 17:46:56 2010, Dmass, Laser, Doubling, Intensity Noise Measurement, and Coherence PDCoherence.pdf
Entry  Thu Feb 18 00:45:53 2010, Dmass, Laser, Doubling, AA Noise, and slow channels added... 
    Reply  Thu Feb 18 04:29:02 2010, Dmass, Laser, Doubling, AA Noise, and slow channels added... AntiAliasNoiseALL.pdfArmBlockSpectra.pdfArmBlockedCoh.pdfWTFMZ.pdf
Entry  Thu Feb 18 18:04:07 2010, Mott, Laser, Fiber, Mode Shape of the fiber laser BeamMode_Laser_Rough.png
    Reply  Thu Feb 18 20:09:32 2010, Mott, Laser, Fiber, Mode Shape of the fiber laser 
Entry  Thu Feb 18 18:49:21 2010, Dmass, Electronics, Doubling, Bad PD?! 
    Reply  Thu Feb 18 21:16:01 2010, Dmass, Electronics, Doubling, Bad PD?! PDDarkNoise.pdf
       Reply  Fri Feb 19 01:04:35 2010, Dmass, Electronics, Doubling, Bad PD?! 
          Reply  Fri Feb 19 07:54:14 2010, rana, Electronics, Doubling, Bad PD?! 
Entry  Mon Feb 22 13:14:26 2010, Frank, Computing, DAQ, fb0 replacement disks arrived 
Entry  Thu Feb 18 18:14:20 2010, Zach, Laser, GYRO, update (AOM) 
    Reply  Fri Feb 19 10:22:26 2010, Alastair, Laser, GYRO, update (AOM) AOM_mount.pdf
       Reply  Mon Feb 22 13:24:04 2010, Alastair, Laser, GYRO, update (AOM) 
Entry  Mon Feb 22 15:44:47 2010, Frank, Computing, DAQ, day(s) for data rescue? 
Entry  Wed Feb 24 04:35:04 2010, Dmass, Laser, Doubling, New Mach Zehnder Layout! 
Entry  Wed Feb 24 00:27:14 2010, Dmass, Lab Infrastructure, Doubling, Doubling Crystal Damaged 
    Reply  Thu Feb 25 01:00:31 2010, Dmass, Lab Infrastructure, Doubling, Doubling Experiment Update! 
       Reply  Fri Feb 26 01:50:06 2010, Dmass, Lab Infrastructure, Doubling, Doubling Experiment Update! 
          Reply  Fri Feb 26 16:19:05 2010, Dmass, Lab Infrastructure, Doubling, Doubling Experiment Update! PD1AnaNoise.pdfPD2AnaNoise.pdfPD3AnaNoise.pdfPD4AnaNoise.pdf
Entry  Mon Mar 1 19:41:25 2010, Zach, Laser, GYRO, AOM double-pass 
Entry  Tue Mar 2 12:41:23 2010, Dmass, Electronics, Doubling, Op Amps GreenAD743z100k.PNGGreenOPA627z100k.PNGISSAD829z500.PNG
Entry  Tue Mar 2 20:09:16 2010, Zach, Laser, GYRO, cavity "locked" in both directions bidirectional_lock_ish.jpg
    Reply  Tue Mar 2 21:03:36 2010, Koji, Laser, GYRO, cavity "locked" in both directions 
Entry  Wed Mar 3 00:22:05 2010, Dmass, Electronics, General, OP AMP WOES 
    Reply  Wed Mar 3 08:39:41 2010, rana, Electronics, General, OP AMP WOES 
Entry  Wed Mar 3 15:49:09 2010, Frank, Computing, DAQ, hard disk replaced 
Entry  Thu Mar 4 23:03:14 2010, Dmass, Laser, Doubling, MZ Complete! 
Entry  Wed Mar 3 17:58:29 2010, Dmass, Electronics, Doubling, GreenPD Noise GreenPD.pngphoto(3).jpg
    Reply  Thu Mar 4 01:26:50 2010, rana, Electronics, Doubling, GreenPD Noise 
    Reply  Thu Mar 4 23:07:50 2010, Dmass, Electronics, Doubling, GreenPD Noise 
Entry  Fri Mar 5 00:09:29 2010, Dmass, Lab Infrastructure, General, Camera Maintanence 
Entry  Fri Mar 5 00:12:56 2010, rana, Electronics, General, Voltage Regulator Noise w/ the python GPIB scripts lt7812.png
Entry  Fri Mar 5 00:46:10 2010, Dmass, Laser, Doubling, Mach Zehnder Rebuild MachZehnderReradout.png100_0675.JPG
Entry  Thu Mar 4 01:38:40 2010, rana, Electronics, GYRO, UPDH box s/n 1437 examined u.pdf
    Reply  Fri Mar 5 02:42:03 2010, rana, Electronics, GYRO, UPDH box s/n 1437 upgraded updh1437-sweep.pngupdh1437-noise.png
Entry  Thu Mar 4 20:41:42 2010, Alastair, Laser, GYRO, Finesse measurement GYRO_bandwidth.jpg
    Reply  Thu Mar 4 22:18:05 2010, Zach, Laser, GYRO, Finesse measurement 
    Reply  Thu Mar 4 22:33:15 2010, rana, Laser, GYRO, Finesse measurement 
       Reply  Fri Mar 5 09:12:06 2010, Alastair, Laser, GYRO, Finesse measurement 
          Reply  Fri Mar 5 13:25:21 2010, Koji, Laser, GYRO, Finesse measurement 
Entry  Fri Mar 5 15:46:15 2010, Mott, Laser, Fiber, Mode Shape of Fiber Laser FiberModeShape.png
Entry  Fri Mar 5 16:23:51 2010, Alastair, Laser, GYRO, Locking and other stuff 
Entry  Sat Mar 6 15:02:37 2010, Dmass, Computing, DAQ, Test Points Busted 
Entry  Mon Mar 8 13:53:42 2010, Dmass, Computing, DAQ, Don't do this to the front end... 
    Reply  Mon Mar 8 21:06:35 2010, Zach, Computing, DAQ, Don't do this to the front end... 
Entry  Mon Mar 8 21:54:01 2010, Zach, Laser, GYRO, update 
Entry  Tue Mar 9 00:24:30 2010, Dmass, Laser, Doubling, Mach Zehnder Contrast 
Entry  Mon Mar 8 02:19:45 2010, Dmass, Electronics, Doubling, AC Coupling... ACCouple560.pdf
    Reply  Mon Mar 8 21:25:22 2010, Dmass, Electronics, Doubling, AC Coupling... ACCoup560.pdfACCoupRecom.pdfACCoupl.png
       Reply  Tue Mar 9 03:59:51 2010, Dmass, Electronics, Doubling, AC Coupling... 8x
Entry  Mon Mar 8 21:22:56 2010, Zach, Laser, GYRO, summing amp for CW loop summing_amp.jpg
    Reply  Tue Mar 9 12:10:03 2010, rana, Laser, GYRO, summing amp for CW loop 
       Reply  Tue Mar 9 12:38:40 2010, Zach, Laser, GYRO, summing amp for CW loop 
Entry  Tue Mar 9 21:13:24 2010, Dmass, Laser, ISS, Adding ISS 
    Reply  Tue Mar 9 23:55:29 2010, Dmass, Laser, ISS, Adding ISS ISS.png
       Reply  Wed Mar 10 12:52:10 2010, Dmass, Laser, ISS, Adding ISS 
Entry  Wed Mar 10 13:41:17 2010, Zach, Laser, GYRO, CW error signal nonexistent 
    Reply  Wed Mar 10 16:36:45 2010, Alastair, Laser, GYRO, CW error signal nonexistent 
    Reply  Wed Mar 10 18:34:10 2010, rana, Laser, GYRO, CW error signal nonexistent 
Entry  Thu Mar 11 02:04:24 2010, Dmass, Laser, ISS, ISS Woes 
    Reply  Thu Mar 11 02:36:04 2010, Dmass, Laser, ISS, ISS Woes ISSCircuit.JPG
Entry  Thu Mar 11 14:52:28 2010, Zach, Laser, GYRO, A tale of two PDs 
    Reply  Fri Mar 12 09:18:44 2010, Alastair, Laser, GYRO, A tale of two PDs 
Entry  Fri Mar 12 21:44:28 2010, Dmass, Laser, Doubling, Data Time Stamps for LV Meeting 
Entry  Fri Mar 12 17:27:22 2010, Alastair, Laser, GYRO, Isomet shmisomet isomet_oscillator.jpg
    Reply  Sat Mar 13 07:32:20 2010, rana, Electronics, GYRO, Isomet shmisomet 
       Reply  Sat Mar 13 11:45:20 2010, Alastair, Electronics, GYRO, Isomet shmisomet 
Entry  Tue Mar 16 16:57:34 2010, Alastair, Lab Infrastructure, GYRO, Rehousing stuff 
Entry  Tue Mar 16 17:34:35 2010, Alastair & Zach, Laser, GYRO, GYRO CAVITY LOCKED IN BOTH DIRECTIONS IMG_9440.JPGIMG_9444.JPGIMG_9448.JPG
    Reply  Wed Mar 17 05:19:24 2010, rana, Laser, GYRO, GYRO CAVITY LOCKED IN BOTH DIRECTIONS gyro-photo.jpg
    Reply  Wed Mar 17 08:48:32 2010, Aidan, Laser, GYRO, GYRO CAVITY LOCKED IN BOTH DIRECTIONS 
Entry  Wed Mar 17 09:12:34 2010, Koji, Laser, PMC, PSL glitch investigation 
Entry  Wed Mar 17 18:01:16 2010, Alastair, Laser, GYRO, First sensitivity curve gyrosensitivity_01.jpg
    Reply  Wed Mar 17 18:57:55 2010, Alastair, Laser, GYRO, Second sensitivity curve gyrosensitivity_02.jpg
Entry  Thu Mar 18 15:59:46 2010, Frank, Laser, stuff happens, Amplifier service 
Entry  Wed Mar 17 16:18:32 2010, Dmass, Laser, PSL, Realignment 
    Reply  Wed Mar 17 20:17:27 2010, Dmass, Laser, PSL, Realignment PMCOLTFanalog.png
       Reply  Thu Mar 18 16:26:06 2010, Dmass, Laser, PSL, Realignment 
Entry  Thu Mar 18 16:47:36 2010, Alastair, Lab Infrastructure, GYRO, Enclosure not yet ready... 
Entry  Fri Mar 19 15:20:47 2010, Dmass, Computing, DAQ, Foton Broken? 
Entry  Fri Mar 19 16:52:51 2010, Dmass, Laser, Doubling, Time Stamps 
    Reply  Fri Mar 19 21:25:48 2010, Dmass, Laser, Doubling, Time Stamps 
       Reply  Fri Mar 19 22:50:20 2010, Dmass, Laser, Doubling, Time Stamps LVSubSpec.pdfNewSub.pdf
          Reply  Sat Mar 20 19:03:34 2010, Dmass, Laser, Doubling, Time Stamps 
Entry  Sat Mar 20 20:36:53 2010, Dmass, Laser, PSL, Power Steps ACCoupRecom.pdf
    Reply  Mon Mar 22 19:46:06 2010, Dmass, Laser, PSL, Power Steps 
Entry  Mon Mar 22 23:12:10 2010, Zach, Laser, GYRO, looking in the wrong place? 
    Reply  Tue Mar 23 10:10:20 2010, Alastair, Laser, GYRO, looking in the wrong place? 
       Reply  Tue Mar 23 10:22:30 2010, Zach, Laser, GYRO, looking in the wrong place? 
Entry  Tue Mar 23 10:22:31 2010, Alastair, Laser, GYRO, Notch filter active_twin_t.pngnotchfilter.jpg
    Reply  Tue Mar 23 10:32:46 2010, Zach, Laser, GYRO, Notch filter 
       Reply  Tue Mar 23 10:41:58 2010, Alastair, Laser, GYRO, Notch filter 
Entry  Tue Mar 23 21:05:45 2010, Frank, Lab Infrastructure, General, laser safety sign replacement bulbs 
Entry  Wed Mar 24 20:09:49 2010, Zach & Alastair, Laser, GYRO, noise/signal diagram servo_diagram.png
Entry  Thu Mar 25 12:40:28 2010, Alastair, Things to Buy, General, Shoe covers on order - should be here in about 2 days 
Entry  Fri Apr 2 19:54:27 2010, Alastair, Laser, GYRO, Box DSC03070.JPG
Entry  Mon Apr 5 14:46:05 2010, Alastair, Laser, GYRO, CCW locking 
Entry  Tue Apr 6 21:06:21 2010, Frank, Misc, Pulser, diode damage tests 
Entry  Tue Apr 6 21:32:42 2010, Frank, Computing, General, spare hard disks 
Entry  Wed Apr 7 19:12:47 2010, Zach, Laser, GYRO, Y1S reflectivities 
Entry  Tue Apr 6 11:51:15 2010, Koji, Laser, Doubling, MZ lock response.pngoltf.png
    Reply  Wed Apr 7 21:29:48 2010, Dmass, Laser, Doubling, MZ lock 
Entry  Fri Apr 9 11:26:08 2010, Mott, Lab Infrastructure, General, GPIB Controllers 
Entry  Mon Mar 22 15:01:24 2010, Dmass, Laser, ISS, ISS Spectra ISSILandOL.pdfGreenPDsBudget.pngIRPDsBudget.pngPDSubtracAll.pdf
    Reply  Tue Mar 23 15:01:29 2010, Dmass, Laser, ISS, ISS Spectra SubtractTestCoh.pdfSubtractTest.pdf
       Reply  Tue Mar 23 17:05:11 2010, Dmass, Laser, ISS, ISS Spectra 
          Reply  Tue Mar 23 21:24:57 2010, Dmass, Laser, ISS, ISS Spectra 
             Reply  Wed Mar 24 00:09:39 2010, Dmass, Laser, ISS, ISS Spectra 
                Reply  Wed Mar 24 22:12:49 2010, Mott, Laser, ISS, fb0 error 
                   Reply  Fri Mar 26 17:05:43 2010, Mott, Laser, ISS, fb0 error 
                      Reply  Tue Mar 30 16:44:20 2010, Mott, Laser, ISS, fb0 error 
                         Reply  Fri Apr 9 11:35:56 2010, Mott, Laser, ISS, fb0 error 
    Reply  Thu Mar 25 02:06:53 2010, Dmass, Laser, ISS, ISS Spectra 
       Reply  Thu Mar 25 02:38:54 2010, Koji, Laser, ISS, ISS Spectra 
          Reply  Thu Mar 25 10:38:24 2010, mevans, Laser, ISS, ISS Spectra 
          Reply  Thu Mar 25 13:29:18 2010, Dmass, Laser, ISS, ISS Spectra 
             Reply  Thu Mar 25 14:16:32 2010, Dmass, Laser, ISS, MZ Spectra! rawdata.zipLockedPhaseNoise.pdf
Entry  Fri Apr 9 21:19:33 2010, Frank, Computing, DAQ, fb0 online again 
Entry  Tue Apr 13 00:19:00 2010, Mott, Frank, Computing, DAQ, fb0 boot disk copies 
Entry  Tue Apr 13 15:32:51 2010, Koji, Laser, Doubling, Both MZ and ISS locked 
    Reply  Wed Apr 14 16:00:56 2010, Dmass, Laser, Doubling, Both MZ and ISS locked 
Entry  Sat Apr 17 19:05:50 2010, Frank, Lab Infrastructure, General, router problems 
Entry  Sun Apr 18 18:34:50 2010, Frank, Lab Infrastructure, General, router keeps diconnecting, backup connection installed 
Entry  Mon Apr 19 19:09:42 2010, Frank, Computing, DAQ, todays DAQ odyssey - part 1 
Entry  Mon Apr 19 19:11:31 2010, Frank, Computing, DAQ, front-end down due to major software changes 
Entry  Tue Apr 20 18:54:18 2010, Frank, Computing, DAQ, DAQ odyssey - part 2 
Entry  Tue Apr 20 19:54:24 2010, Frank, Computing, DAQ, card identification 
Entry  Fri Apr 23 17:20:34 2010, Zach, Electronics, GYRO, RFPD circuit 
Entry  Wed Apr 28 09:24:01 2010, Aidan, Computing, fubar, elog craziness - test to try and crash elog 40m_figure_ETM.pdf
Entry  Wed Apr 28 15:39:45 2010, Zach, Lab Infrastructure, General, marking remaining holes 
    Reply  Wed Apr 28 19:07:07 2010, Frank, Lab Infrastructure, General, marking remaining holes 
Entry  Wed Apr 28 10:16:09 2010, Frank, Lab Infrastructure, General, lab cleanliness - latest particle counts AdhikariLab_data_repair.png
    Reply  Wed Apr 28 11:19:36 2010, Alastair, Lab Infrastructure, General, lab cleanliness - latest particle counts 
    Reply  Wed Apr 28 13:21:11 2010, Alastair, Lab Infrastructure, General, lab cleanliness - latest particle counts 
    Reply  Wed Apr 28 14:57:14 2010, rana, Lab Infrastructure, General, lab cleanliness - latest particle counts 
    Reply  Wed Apr 28 19:10:57 2010, Dmass, Lab Infrastructure, General, lab cleanliness - latest particle counts 
Entry  Wed Apr 28 19:57:19 2010, Dmass, Laser, PSL, KEYS TO 35W MISSING 
Entry  Mon May 3 11:59:28 2010, Zach, Laser, GYRO, modifications 
    Reply  Mon May 3 12:19:52 2010, rana, Laser, GYRO, modifications 
Entry  Tue May 4 12:06:37 2010, Zach, Laser, GYRO, 6-m mirrors are OK--back to the drawing board  
    Reply  Wed May 5 15:09:35 2010, Zach, Laser, GYRO, 6-m mirrors are OK--back to the drawing board  
Entry  Fri May 7 07:42:09 2010, Aidan, Lab Infrastructure, HVAC, Re-sealing and laser keys 
    Reply  Fri May 7 10:16:24 2010, Zach, Lab Infrastructure, HVAC, Re-sealing and laser keys 
       Reply  Fri May 7 11:10:17 2010, Alastair, Lab Infrastructure, HVAC, Re-sealing and laser keys 
Entry  Thu May 6 19:45:10 2010, Dmass, Laser, stuff happens, Chalkboard Discipline.gif
    Reply  Fri May 7 03:22:50 2010, Bob, Laser, Doubling, Chalkboard SideshowBob2.png
       Reply  Fri May 7 11:15:58 2010, Bob, Laser, Doubling, Chalkboard 
Entry  Tue Apr 20 22:33:59 2010, Frank, Computing, DAQ, fb0 up again and working 
    Reply  Fri May 7 14:39:01 2010, Dmass, Computing, DAQ, fb0 up again and working 
Entry  Fri May 7 15:52:58 2010, Frank, Misc, Pulser, basic diagram for diode pulsing-test pd-pulse-test_v2.png
Entry  Tue Apr 27 11:46:30 2010, Zach, Misc, General, Where is the camera?? 
    Reply  Wed Apr 28 15:28:04 2010, Zach, Misc, General, Where is the camera?? 
       Reply  Fri May 7 16:40:31 2010, Frank, Misc, General, Where is the camera?? 
Entry  Sat May 8 13:53:01 2010, Zach, Laser, GYRO, cavity spectrum 150ppm.png150ppm_T3_005.pngUntitled.png
Entry  Sat May 8 17:24:55 2010, Zach, Misc, General, function for calculating parameters of an arbitrary cavity aLIGO_PMC.pngarbcav.m
Entry  Mon May 10 15:48:22 2010, Zach, Misc, General, camera at my desk 
Entry  Tue May 11 16:53:08 2010, Alastair, Rana, Lab Infrastructure, HVAC, Particle count and temperature May_11.jpgMay_11_temp.jpgDataForAir_100512_141411.csv.gz
    Reply  Tue May 11 20:12:54 2010, Zach, Lab Infrastructure, HVAC, Particle count and temperature 
       Reply  Tue May 11 21:03:57 2010, Alastair, Lab Infrastructure, HVAC, Particle count and temperature 
Entry  Wed May 12 03:48:07 2010, rana, Lab Infrastructure, HVAC, status 
Entry  Wed May 12 11:12:25 2010, Frank, Misc, General, the lab this morning 
Entry  Wed May 12 11:17:50 2010, Frank, Lab Infrastructure, PEM, new, temporary sensor in corridor 
Entry  Wed May 12 14:44:18 2010, Frank, Misc, General, lab temperature 
Entry  Wed May 12 19:12:30 2010, Frank, Misc, General, lab temp back to normal 
Entry  Sat May 8 01:08:42 2010, Frank, Computing, DAQ, fb0 fixed 
    Reply  Wed May 12 23:20:38 2010, Dmass, Computing, DAQ, fb0 fixed 
Entry  Thu May 13 20:47:34 2010, Frank, Computing, DAQ, fb0 online again 
Entry  Mon May 17 16:46:23 2010, Alastair, Things to Buy, GYRO, mirrors 
Entry  Wed May 5 18:14:42 2010, Dmass, Laser, Doubling, Massive Update plottedApr20Phase.pdf
    Reply  Wed May 19 19:33:55 2010, Dmass, Laser, Doubling, More Update Plotted14Phase.pdfplotted16RIN.pdfPlotted14Volts.pdfplotted16Volts.pdf
    Reply  Wed May 19 19:54:40 2010, Dmass, Laser, Doubling, Massive Update MZPhaseLowAvg.pdf
Entry  Mon May 24 11:02:14 2010, Zach, Lab Infrastructure, HVAC, Duct sealing photo summary 38x
Entry  Mon May 24 17:35:41 2010, Aidan, Laser, General, Lasers powered down 
Entry  Tue May 25 08:27:44 2010, Alastair, Laser, GYRO, PDH box 1 PDH_box2.jpgPDH_box_1.jpg
Entry  Wed May 26 17:13:07 2010, Aidan, Lab Infrastructure, stuff happens, Moved a New Focus 9071 4-axis stage to 40m for doubling 
Entry  Wed Jun 2 09:37:03 2010, Alastair, Lab Infrastructure, General, Particle count 
Entry  Wed Jun 2 11:20:02 2010, Alastair, Laser, GYRO, Mirror transmission 
    Reply  Wed Jun 2 14:05:59 2010, Alastair, Laser, GYRO, Mirror transmission 
    Reply  Wed Jun 2 17:11:58 2010, Zach, Laser, GYRO, Mirror transmission 
Entry  Fri May 7 16:51:09 2010, Frank, Lab Infrastructure, General, particle counter 
    Reply  Wed Jun 2 17:59:57 2010, rana, Lab Infrastructure, General, particle counter + lab temp 
Entry  Wed Jun 2 20:24:26 2010, rana, alastair, Misc, GYRO, Optics moved 
Entry  Wed Jun 2 07:16:38 2010, Frank, Computing, DAQ, fb0 down? 
    Reply  Thu Jun 3 03:23:09 2010, Dmass, Computing, DAQ, fb0 down? 
Entry  Thu Jun 3 03:24:41 2010, Dmass, Lab Infrastructure, Fugly, Rack terrible-ness 00001.jpg
Entry  Thu Jun 3 15:49:06 2010, Frank, Computing, DAQ, fb0 still not working, plz reboot it - can't work since a week 
Entry  Thu Jun 3 18:29:10 2010, Alastair & Rana, Laser, GYRO, Mode matching and cavity alignment 
Entry  Wed May 19 22:40:19 2010, Dmass, Electronics, Doubling, Oddness with my box Plotted17.pdfMZVoltsLowAvg.pdf
    Reply  Wed May 19 23:33:18 2010, Dmass, Electronics, Doubling, Oddness with my box 
       Reply  Thu May 20 00:41:51 2010, Koji, Electronics, Doubling, Oddness with my box 
          Reply  Thu May 20 21:43:01 2010, Dmass, Electronics, Doubling, Oddness with my box 
             Reply  Fri May 21 17:42:29 2010, Dmass, Electronics, Doubling, The Box Itself MZ_Electronics.pdfMZBoxGoodPic.png
                Reply  Fri Jun 4 13:46:26 2010, Dmass, Electronics, Doubling, The Box Itself 
Entry  Thu Jun 3 10:59:37 2010, Frank, Computing, DAQ, fb0 reboot 
    Reply  Fri Jun 4 13:52:44 2010, Frank, Computing, DAQ, fb0 reboot 
       Reply  Fri Jun 4 21:32:54 2010, Frank, Computing, DAQ, fb0 reboot 
Entry  Tue Jun 8 10:35:16 2010, Aidan, Misc, stuff happens, Moved some equipment to 40m 
Entry  Tue Jun 8 10:49:34 2010, Frank, Lab Infrastructure, General, several things offline / not working as usual 
    Reply  Wed Jun 9 15:13:15 2010, Alastair, Lab Infrastructure, General, several things offline / not working as usual 
       Reply  Thu Jun 10 02:08:15 2010, Frank, Lab Infrastructure, General, several things offline / not working as usual 
Entry  Thu Jun 10 21:18:18 2010, Dmass, Computing, DAQ, FB0 fixed 
    Reply  Fri Jun 11 02:44:09 2010, Frank, Computing, DAQ, FB0 fixed 
Entry  Fri Jun 11 21:27:50 2010, Koji, Computing, General, X11 on WS1 can not find nVidia driver 
Entry  Mon Jun 14 14:40:10 2010, Frank, Misc, General, company for temp ctrls and diode drivers 
Entry  Fri Jun 4 23:22:41 2010, Dmass, Electronics, Doubling, Oven Control Updates 
    Reply  Tue Jun 15 23:47:09 2010, Dmass, Electronics, Doubling, Oven Control Updates 
Entry  Thu Jun 17 11:05:42 2010, Frank, Lab Infrastructure, HVAC, HVAC now working again 
    Reply  Fri Jun 18 00:48:11 2010, rana, Lab Infrastructure, HVAC, HVAC now working again 
Entry  Fri Jun 11 20:33:17 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions dmassFE.png
    Reply  Wed Jun 16 15:54:20 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions 
       Reply  Wed Jun 16 23:10:28 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions 
          Reply  Thu Jun 17 15:14:58 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions CuOvenIStepResponse.pdf
             Reply  Fri Jun 18 18:04:23 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions 
                Reply  Fri Jun 18 18:07:53 2010, Dmass, Computing, DAQ, Attempt at oven transfer functions 
Entry  Sat Jun 19 19:20:29 2010, rana, Electronics, GYRO, IFR / Marconi Phase noise w/ Rubidium clock lock IFR.png
    Reply  Mon Jun 21 09:44:31 2010, Frank, Electronics, GYRO, IFR / Marconi Phase noise w/ Rubidium clock lock 
Entry  Wed Jun 23 13:47:01 2010, Frank, Lab Infrastructure, HVAC, latest particle counts AdhikariLab_data_061810.png
Entry  Wed Jun 23 17:57:00 2010, Frank, Lab Infrastructure, HVAC, temperature fluctuations - before and after  temp_ATF1.pngtemp_ATF2.png
Entry  Wed Jun 23 18:15:59 2010, Aidan, Lab Infrastructure, HVAC, New temperature controllers 00001.jpg00002.jpg00003.jpg
Entry  Thu Jun 24 18:49:04 2010, Frank, Misc, General, USB-to-serial converter back at 40m 
Entry  Mon Jun 21 20:46:40 2010, Dmass, Computing, General, Oven interfacing 
    Reply  Tue Jun 22 19:17:27 2010, Dmass, Computing, General, Oven interfacing 
       Reply  Tue Jun 22 21:53:24 2010, Dmass, Computing, General, Oven interfacing 
          Reply  Wed Jun 23 15:59:13 2010, Dmass, Computing, General, Oven interfacing OvenOLMeas.pdf
             Reply  Wed Jun 23 21:53:50 2010, Dmass, Computing, General, Oven interfacing 
                Reply  Thu Jun 24 21:18:49 2010, Dmass, Computing, General, Oven interfacing OvenLoopTesting.pdf
                   Reply  Sun Jun 27 18:02:51 2010, Dmass, Computing, General, Oven interfacing 
Entry  Mon Jun 28 01:36:57 2010, Frank, Computing, General, currently no access to ATF from outside 
    Reply  Mon Jun 28 16:13:21 2010, Aidan, Computing, General, currently no access to ATF from outside 
Entry  Mon Jun 28 17:33:32 2010, Jenna, Laser, GYRO, Mode Matching mode_match.tar
    Reply  Tue Jun 29 00:40:53 2010, Dmass, Laser, GYRO, Mode Matching 
       Reply  Tue Jun 29 13:12:56 2010, Alastair, Laser, GYRO, Mode Matching 
Entry  Tue Jun 29 14:27:10 2010, Jenna, Laser, GYRO, Comparison of frequency noise and mechanical noise for the gyro cavity frequency_and_mechanical_noise.png
    Reply  Tue Jun 29 15:41:01 2010, Alastair, Laser, GYRO, Comparison of frequency noise and mechanical noise for the gyro cavity 
       Reply  Tue Jun 29 17:48:31 2010, Zach, Laser, GYRO, Comparison of frequency noise and mechanical noise for the gyro cavity 
       Reply  Wed Jun 30 00:35:28 2010, rana, Laser, GYRO, Comparison of frequency noise and mechanical noise for the gyro cavity 
Entry  Wed Jun 30 18:19:47 2010, Jenna, Laser, GYRO, Cavity Mirrors 
Entry  Thu Jul 1 17:47:19 2010, Jenna, Laser, GYRO, Mode Matching Solution 
Entry  Tue Jul 6 21:07:42 2010, rana, Things to Buy, GYRO, IR viewer missing: found in TCS lab 
Entry  Wed Jul 7 13:59:26 2010, Jenna, Laser, GYRO, Mode Matching power_coupling_vs_lens_2_position_for_1064nm.pngpower_coupling_vs_lens_1_position_for_1064nm.png
Entry  Thu Jul 8 00:16:43 2010, Dmass, Laser, Doubling, Forty Two 
    Reply  Thu Jul 8 13:17:01 2010, Dmass, Laser, Doubling, Forty Two 
Entry  Mon Jul 12 13:16:59 2010, Jenna, Laser, GYRO, CCW Alignment 7-9_CCW_alignment.png7-9_CCW_alignment-2.png
Entry  Mon Jul 12 18:48:15 2010, Jenna, Misc, GYRO, Translation Stages from 40m HPIM3679.JPG
Entry  Wed Jul 14 21:48:02 2010, Jenna, Laser, GYRO, CCW Lock CCW_lock_714.jpg
Entry  Fri Jul 16 19:23:27 2010, Alastair, Laser, Fugly, noise measurement of locked cavity freq_noise.pdfnoise_from_locked_cavity.mat
    Reply  Mon Jul 19 13:34:39 2010, Zach, Laser, GYRO, noise measurement of locked cavity 
Entry  Tue Jul 20 15:44:07 2010, Aidan, Computing, General, Fixed two new static IP addresses for TCS machines 
Entry  Wed Jul 21 14:21:17 2010, Dmass, Laser, PSL, Characterizing the H1 NPRO P7140293.pngP7140301.pngP7140304.png
Entry  Tue May 18 09:43:55 2010, Aidan, Computing, DAQ, Killed the DAQD process. It restarted automatically. 
    Reply  Tue Jul 20 18:12:02 2010, Aidan, Computing, DAQ, Killed the DAQD process. It restarted automatically. 
       Reply  Wed Jul 21 13:59:29 2010, Dmass, Computing, DAQ, Killed the DAQD process. It restarted automatically. 
          Reply  Wed Jul 21 14:20:54 2010, Jenne, Computing, DAQ, Killed the DAQD process. It restarted automatically. 
             Reply  Wed Jul 21 20:08:53 2010, Dmass, Computing, DAQ, Killed the DAQD process. It restarted automatically. 
Entry  Thu Jul 22 20:07:20 2010, Dmass, Computing, DAQ, FB0 Problem...fixed 
Entry  Thu Jul 22 10:13:31 2010, Alastair, Laser, GYRO, GYRO update 
    Reply  Thu Jul 22 21:27:23 2010, Zach, Laser, GYRO, GYRO update 
Entry  Tue Jul 27 14:46:42 2010, Jenna, Laser, GYRO, Seismometer Measurements seismic727.pdfGuralp_spec_sheet
Entry  Wed Jul 28 21:18:44 2010, Alastair, Laser, GYRO, Rubidium clock 
Entry  Thu Jul 29 13:20:13 2010, Alastair, Computing, General, Dataviewer 
Entry  Thu Jul 29 19:19:42 2010, Alastair, Laser, GYRO, CW beam alignment cavity.jpg
Entry  Thu Jul 29 20:05:05 2010, Alastair, Laser, GYRO, Rubidium clocks rubidium.JPG
Entry  Thu Jul 29 12:09:56 2010, Alastair, Laser, GYRO, Seismometer Measurements Continued 10_07_29_seismic01.pdf
    Reply  Fri Jul 30 00:48:11 2010, Dmass, Laser, GYRO, Seismometer Measurements Continued 
Entry  Fri Jul 30 01:56:07 2010, Dmass, Lab Infrastructure, Purchases, Bought some lenses 
Entry  Fri Jul 30 15:36:22 2010, Dmass, Computing, DAQ, Elog changes to the framebuilder 
Entry  Fri Jul 30 19:11:10 2010, Alastair, Laser, GYRO, Rubidium rubidium_measurement.pdf
Entry  Mon Aug 2 16:30:34 2010, Jenne, Misc, PEM, Guralp Stuff removed to the 40m 
Entry  Wed Jul 14 14:39:09 2010, Dmass, Laser, PSL, H1 NPRO Measured NPROWaist.pdf
    Reply  Thu Jul 15 15:41:40 2010, Dmass, Laser, PSL, H1 NPRO Measured 
       Reply  Fri Jul 16 18:54:57 2010, Dmass, Laser, PSL, H1 NPRO Measured H1ModeMSoln.pdf
          Reply  Sat Jul 17 01:41:20 2010, Koji, Laser, PSL, H1 NPRO Measured 
          Reply  Wed Jul 21 20:13:06 2010, Dmass, Laser, PSL, H1 NPRO Measured H1NPRO_AM.png
             Reply  Thu Jul 22 16:19:48 2010, Koji, Laser, PSL, H1 NPRO Measured 
             Reply  Fri Jul 23 00:45:46 2010, Dmass, Laser, PSL, H1 NPRO Measured 
                Reply  Tue Jul 27 00:10:20 2010, Dmass, Laser, PSL, PMC Calibrated PMCCtrl.pdf
             Reply  Tue Jul 27 19:04:35 2010, Dmass, Laser, PSL, H1 NPRO Measured NproPZTFMBode.pdf
                Reply  Wed Jul 28 19:51:10 2010, Dmass, Laser, PSL, H1 NPRO Measured IMG_0241.png
                   Reply  Fri Jul 30 16:48:11 2010, Dmass, Laser, PSL, H1 NPRO Measured 
                      Reply  Sun Aug 1 18:37:07 2010, Dmass, Laser, PSL, H1 NPRO Measured 
                   Reply  Mon Aug 2 00:46:13 2010, Dmass, Laser, PSL, H1 NPRO Measured Picture_2.png
    Reply  Mon Aug 2 22:23:36 2010, Dmass, Laser, PSL, H1 NPRO Measured H1MM2PMC.pdf
    Reply  Tue Aug 3 01:31:15 2010, Dmass, Laser, PSL, H1 NPRO Measured H1NPROWaist2.pdf
       Reply  Tue Aug 3 13:47:55 2010, Dmass, Laser, PSL, H1 NPRO Measured Npro2PMCmm.pdf
       Reply  Tue Aug 3 17:27:20 2010, Dmass, Laser, PSL, H1 NPRO Measured 
Entry  Wed Aug 4 17:24:11 2010, Alastair, Laser, GYRO, Photodiode for transmission 
Entry  Wed Aug 4 18:52:18 2010, Jenna, Laser, GYRO, AOM Feedback Signal AOM8-4.pdf
    Reply  Wed Aug 4 20:26:30 2010, rana, Laser, GYRO, AOM Feedback Signal 
       Reply  Wed Aug 4 20:34:48 2010, Alastair, Laser, GYRO, AOM Feedback Signal 
Entry  Fri Aug 6 00:44:06 2010, Frank, Lab Infrastructure, General, wifi bridges configured 
Entry  Sat Aug 7 13:45:13 2010, Frank, Lab Infrastructure, General, wireless GPIB network devices now available 
Entry  Sun Aug 1 23:16:45 2010, Dmass, Lab Infrastructure, General, WHERE IS THE WINCAMD? IMG_0248.pngIMG_0250.jpg
    Reply  Mon Aug 2 00:50:58 2010, Zach, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
       Reply  Mon Aug 2 12:24:01 2010, Dr. Evil, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
          Reply  Mon Aug 2 14:15:10 2010, Dmass, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
       Reply  Mon Aug 2 16:11:41 2010, Homer, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
    Reply  Mon Aug 2 21:02:19 2010, Dmass, Lab Infrastructure, General, PMC Waist PMCwaist.pdf
    Reply  Fri Aug 6 14:12:22 2010, Dmass, Lab Infrastructure, General, WHERE IS THE WINCAMD? H1NPROoutput.PNGH1NPROat21in.PNGH1NPRO120mW.PNG
       Reply  Fri Aug 6 16:56:58 2010, Aidan, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
       Reply  Sat Aug 7 13:45:52 2010, Dmass, Lab Infrastructure, General, WHERE IS THE WINCAMD? 
Entry  Fri Jul 30 13:38:56 2010, Dmass, Laser, Doubling, Mode Matching for Ovens OvenMM.pdf
    Reply  Tue Aug 3 21:43:40 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
       Reply  Tue Aug 3 23:15:14 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
          Reply  Wed Aug 4 17:21:56 2010, Alastair, Laser, Doubling, Mode Matching for Ovens 
          Reply  Sat Aug 7 19:04:07 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
Entry  Mon Aug 9 00:46:48 2010, Frank, Computing, General, netgpib  
Entry  Wed Aug 4 20:28:03 2010, Alastair, Laser, GYRO, Locking.... 
    Reply  Wed Aug 4 23:19:19 2010, Alastair, Laser, GYRO, Locking.... 
       Reply  Mon Aug 9 18:36:14 2010, rana, Laser, GYRO, Zach is feeeling excluded from this lack of locking IMG_1671.JPG
          Reply  Mon Aug 9 20:48:38 2010, Dmass, Laser, GYRO, Zach is feeeling excluded from this lack of locking 
             Reply  Tue Aug 10 13:44:49 2010, Zach, Laser, GYRO, Zach is feeeling excluded from this lack of locking 
Entry  Tue Aug 10 18:23:46 2010, Jenna, Laser, GYRO, Error signal investigations TEK00001.PNGTEK00003.PNG
Entry  Tue Aug 10 18:48:09 2010, Jenna, Laser, GYRO, Error signal investigations TEK00004.PNGTEK00005.PNG
Entry  Tue Aug 10 19:22:19 2010, Jenna, Laser, GYRO, Cavity is locking again! TEK00006.PNG
Entry  Tue Aug 10 20:29:53 2010, Jenna, Laser, GYRO, PD in transmission IGEJNS.TIF
    Reply  Tue Aug 10 22:02:04 2010, Zach, Laser, GYRO, PD in transmission taz51.gif
    Reply  Tue Aug 10 23:44:17 2010, rana, Laser, GYRO, PD in transmission 
       Reply  Wed Aug 11 14:36:54 2010, Alastair, Laser, GYRO, PD in transmission 
Entry  Wed Aug 11 18:51:13 2010, Alastair, Laser, GYRO, attempted PLL 
    Reply  Wed Aug 11 22:42:52 2010, Koji, Laser, GYRO, attempted PLL 
Entry  Thu Aug 12 22:55:22 2010, Jenna, Laser, GYRO, Pictures Beam_Path.pngbeam_path_3.pngbeam_path_1.pngbeam_path_2.png
    Reply  Thu Aug 12 23:26:06 2010, Zach, Laser, GYRO, Pictures 
       Reply  Fri Aug 13 00:11:46 2010, Jenna, Laser, GYRO, Pictures 
          Reply  Fri Aug 13 10:18:20 2010, Jenna, Laser, GYRO, Pictures 
Entry  Thu Aug 12 18:32:37 2010, Alastair, Laser, GYRO, Beam overlap etc TEK00000.PNGTEK00001.PNGTEK00002.PNG
    Reply  Fri Aug 13 15:50:39 2010, Jenna, Laser, GYRO, Beam overlap etc 
Entry  Fri Aug 13 18:22:04 2010, Jenna, Laser, GYRO, Successful PLL gryo_transmission.pdf
Entry  Mon Aug 16 12:33:08 2010, Alastair, Lab Infrastructure, ANTS!, How do we get rid of ants? 
    Reply  Mon Aug 16 13:25:03 2010, Zach, Lab Infrastructure, ANTS!, How do we get rid of ants? 
    Reply  Mon Aug 16 18:36:59 2010, Jenne, Lab Infrastructure, ANTS!, How do we get rid of ants? 
       Reply  Mon Aug 16 18:56:28 2010, 1954 B-movie, Lab Infrastructure, ANTS!, How do we get rid of ants? 
Entry  Mon Aug 16 19:01:20 2010, Alastair, Laser, GYRO, Noisy noise stuff 
Entry  Mon Aug 16 14:19:00 2010, Alastair, Laser, GYRO, Changed to Marconi on AOM gyro_transmission_08_16_10.pdf
    Reply  Mon Aug 16 15:31:27 2010, Zach, Laser, GYRO, Changed to Marconi on AOM 
    Reply  Tue Aug 17 10:18:02 2010, rana, Laser, GYRO, Changed to Marconi on AOM 
       Reply  Tue Aug 17 15:34:02 2010, Alastair, Laser, GYRO, Changed to Marconi on AOM gyro_transmission_08_17_10.pdf
          Reply  Wed Aug 18 03:01:23 2010, rana, Laser, GYRO, Excess noise mystery resolved 
             Reply  Wed Aug 18 10:31:28 2010, Alastair, Laser, GYRO, Excess noise mystery resolved 
Entry  Wed Aug 18 11:52:00 2010, Alastair, Lab Infrastructure, General, Internet in lab was down again 
Entry  Wed Aug 18 12:03:23 2010, Alastair, Electronics, GYRO, PDH boxes TEK00000.PNGTEK00005.PNG
Entry  Wed Aug 18 18:15:49 2010, Alastair, Zach and Rana, Laser, GYRO, PDH locking of the CCW loop TEK00003.PNGTEK00004.PNG
Entry  Wed Aug 18 20:15:45 2010, rana, Computing, DAQ, Never use lower case in MEDM/DAQ/CDS 
Entry  Thu Aug 19 04:11:09 2010, Dmass, Laser, Doubling, PMC problem solved? 
Entry  Thu Aug 19 11:33:31 2010, Alastair, Lab Infrastructure, Computing, router... 
    Reply  Thu Aug 19 11:49:15 2010, Frank, Lab Infrastructure, Computing, router... 
Entry  Wed Aug 18 21:14:49 2010, rana, Computing, General, The BURT situation 
    Reply  Thu Aug 19 11:17:43 2010, Frank, Computing, General, The BURT situation 
       Reply  Thu Aug 19 11:23:44 2010, Rana, Computing, General, The BURT situation 
          Reply  Thu Aug 19 12:01:13 2010, Frank, Computing, General, The BURT situation 
             Reply  Thu Aug 19 12:22:25 2010, Alastair, Computing, General, The BURT situation 
Entry  Thu Aug 19 11:44:23 2010, Alastair, Lab Infrastructure, Computing, Wiki 
    Reply  Thu Aug 19 13:18:17 2010, Alastair, Lab Infrastructure, Computing, Wiki 
Entry  Fri Aug 20 00:56:03 2010, Frank, Computing, DAQ, PSL RT fronend code shutdown 
Entry  Fri Aug 20 21:58:43 2010, Zach, Electronics, GYRO, PDH box S/N: 2215 transfer function TF_PDH_no2215.png
Entry  Sat Aug 21 01:06:04 2010, Zach, Laser, GYRO, still noisy (till the day I die) new_box.png
Entry  Mon Aug 23 13:13:07 2010, Zach, Misc, GYRO, PDH box info put in wiki 
Entry  Tue Aug 24 02:38:42 2010, Zach, Laser, stuff happens, ThorLabs power meter head appears damaged PM_head_damage.jpg
    Reply  Tue Aug 24 03:00:20 2010, Dmass, Laser, stuff happens, ThorLabs power meter head appears damaged 
Entry  Tue Aug 24 02:18:09 2010, Zach, Laser, GYRO, Gyro table displacement noise spectrum gyro_disp_noise.png
    Reply  Tue Aug 24 12:32:41 2010, Jenna, Laser, GYRO, Gyro table displacement noise spectrum 
Entry  Thu Aug 19 22:04:55 2010, Alastair & Rana, Computing, Computing, Front end rebuilt 
    Reply  Fri Aug 20 03:11:50 2010, rana, Computing, CDS, Front end rebuilt ----- BURT notes 
       Reply  Sat Aug 21 01:50:57 2010, rana, Computing, CDS, Front end rebuilt ----- BURT notes 
          Reply  Sat Aug 21 14:28:14 2010, Aidan, Computing, CDS, Front end rebuilt ----- BURT notes 
             Reply  Tue Aug 24 15:10:36 2010, Dmass, Computing, CDS, Front end rebuilt ----- BURT notes 
Entry  Mon Aug 23 20:56:44 2010, Zach, Computing, GYRO, New channels acquired 
    Reply  Tue Aug 24 15:50:22 2010, Dmass, Computing, GYRO, New channels acquired 
       Reply  Tue Aug 24 16:47:41 2010, Zach, Computing, GYRO, New channels acquired 
Entry  Tue Aug 24 18:52:50 2010, Dmass, Laser, Doubling, Notes 
Entry  Tue Aug 24 18:37:37 2010, Zach, Laser, GYRO, Gyro "single-arm" test single_arm.png
    Reply  Tue Aug 24 19:24:58 2010, rana, Laser, GYRO, Gyro "single-arm" test 
       Reply  Tue Aug 24 20:06:16 2010, Zach, Laser, GYRO, Gyro "single-arm" test 
          Reply  Wed Aug 25 01:02:17 2010, rana, Laser, GYRO, Gyro "single-arm" test 
          Reply  Wed Aug 25 01:09:43 2010, Zach, Laser, GYRO, Gyro "single-arm" test single_leg_noise.png
Entry  Fri Aug 20 15:36:01 2010, Dmass, Laser, Doubling, Spectrum Incoming. MZ1_2pn.pdf
    Reply  Wed Aug 25 22:18:35 2010, Dmass, Laser, Doubling, Spectrum Incoming. MZSpecSumDiff.pdf
       Reply  Wed Aug 25 22:58:12 2010, rana, Laser, Doubling, Spectrum Incoming. 
Entry  Wed Aug 25 16:54:57 2010, Dmass, Computing, Doubling, nds server down? 
    Reply  Thu Aug 26 15:57:54 2010, Frank, Computing, Doubling, nds server down? 
Entry  Wed Aug 25 01:28:35 2010, rana, Things to Buy, GYRO, Possible Vacuum system for the GYRO 
    Reply  Thu Aug 26 01:10:11 2010, Alastair, Things to Buy, GYRO, Possible Vacuum system for the GYRO 
       Reply  Thu Aug 26 17:09:08 2010, Alastair, Things to Buy, GYRO, Possible Vacuum system for the GYRO 
Entry  Thu Aug 26 01:01:34 2010, Zach, Laser, GYRO, gyro back to gyro configuration 2010-08-25_13.19.11.jpg2010-08-25_13.20.31.jpg
    Reply  Fri Aug 27 11:51:41 2010, Zach, Laser, GYRO, gyro back to gyro configuration 
Entry  Thu Aug 26 16:27:54 2010, Frank, Computing, DAQ, fb1 down? 
    Reply  Thu Aug 26 16:42:01 2010, Dmass, Computing, DAQ, fb1 down? 
       Reply  Thu Aug 26 17:00:12 2010, Frank, Computing, DAQ, fb1 down? 
          Reply  Thu Aug 26 19:45:52 2010, Dmass, Computing, DAQ, fb1 down? 
             Reply  Thu Aug 26 19:52:15 2010, Frank, Computing, DAQ, fb1 down? 
                Reply  Thu Aug 26 21:59:32 2010, Dmass, Computing, DAQ, fb1 down? 
                   Reply  Fri Aug 27 11:20:54 2010, Zach, Computing, DAQ, fb1 down? 
                      Reply  Fri Aug 27 16:55:55 2010, Frank, Computing, DAQ, working mDV example temp_test.m
Entry  Sun Aug 29 23:04:17 2010, rana, Lab Infrastructure, stuff happens, lab cleanup 
Entry  Tue Aug 31 01:19:12 2010, Dmass, Computing, DAQ, Foton and DTT brokeded 
    Reply  Tue Aug 31 02:37:53 2010, rana, Computing, DAQ, Foton and DTT brokeded 
       Reply  Tue Aug 31 12:30:40 2010, Frank, Computing, DAQ, Foton and DTT brokeded 
          Reply  Tue Aug 31 13:12:14 2010, Frank, Computing, DAQ, changed default shell on fb1 back to bash 
             Reply  Tue Aug 31 21:06:02 2010, Dmass, Computing, DAQ, FB1 SOFTWARE FREEZE 
             Reply  Tue Aug 31 21:46:21 2010, Dmass, Computing, DAQ, changed default shell on fb1 back to bash 
Entry  Tue Aug 31 23:02:35 2010, Frank, Computing, DAQ, current channel list on fb1 - note to remove dead/unused channels 
Entry  Tue Aug 31 22:07:03 2010, Dmass, Computing, DAQ, mDV NDS DTT DV etc 
    Reply  Wed Sep 1 00:13:32 2010, Frank, Computing, DAQ, mDV NDS DTT DV etc 
       Reply  Wed Sep 1 00:33:56 2010, Dmass, Computing, DAQ, mDV NDS DTT DV etc 
Entry  Wed Sep 1 20:31:26 2010, Dmass, Electronics, Doubling, Calibration Line MZCalLinePZT.pdf
    Reply  Thu Sep 2 19:10:04 2010, Dmass, Electronics, Doubling, Calibration Line MZNoiseBud.pdfMZFreqSubRMS.pdf
       Reply  Fri Sep 3 10:21:29 2010, Koji, Electronics, Doubling, Calibration Line 
Entry  Wed Sep 1 02:21:23 2010, rana, Computing, DAQ, some restarts on fb0: too many cooks 
    Reply  Wed Sep 1 04:43:45 2010, Dmass, Computing, DAQ, some restarts on fb0: too many cooks 
    Reply  Fri Sep 3 14:45:20 2010, Dmass, Computing, DAQ, Undocumented change? 
       Reply  Sat Sep 4 00:44:20 2010, Dmass, Computing, DAQ, Undocumented change? 
          Reply  Sat Sep 4 01:49:23 2010, Dmass, Computing, DAQ, Undocumented change? 
             Reply  Sat Sep 4 02:21:46 2010, Frank, Computing, DAQ, Undocumented change? 
                Reply  Sat Sep 4 03:34:42 2010, Dmass, Computing, DAQ, Undocumented change? 
                   Reply  Mon Sep 6 16:23:19 2010, Dmass, Computing, DAQ, SSHD (re?)started 
Entry  Mon Sep 6 16:37:05 2010, Zach, Laser, GYRO, New gyro noise spectrum gyro_noise_9_3_2010.png
Entry  Tue Sep 7 13:28:16 2010, Dmass, Laser, Doubling, MZ Freq Noise Spectrum / Noise Budget MZFreqNoiseBud.pdf
    Reply  Tue Sep 7 23:43:46 2010, Dmass, Laser, Doubling, MZ Freq Noise Spectrum / Noise Budget 
Entry  Wed Sep 8 02:00:36 2010, Dmass, Laser, Doubling, Oven Snafu Update 
Entry  Wed Sep 8 17:51:15 2010, Alastair & Zach, Laser, GYRO, Windows are in photo_3.jpgphoto_4.jpgphoto_2.JPGphoto_5.JPG
    Reply  Wed Sep 8 18:13:26 2010, Alastair & Zach, Laser, GYRO, Windows are in 
Entry  Thu Sep 9 13:12:24 2010, Alastair, Computing, General, paths and aliases 
Entry  Thu Sep 9 12:23:50 2010, Zach, Laser, GYRO, PDH box SWEEP -> OUT TF sweep-out_tf_plot.png
    Reply  Thu Sep 9 14:49:01 2010, Koji, Laser, GYRO, PDH box SWEEP -> OUT TF 
       Reply  Thu Sep 9 17:10:39 2010, Zach, Laser, GYRO, PDH box SWEEP -> OUT TF 
          Reply  Thu Sep 9 20:28:12 2010, Koji, Laser, GYRO, PDH box SWEEP -> OUT TF 
Entry  Thu Sep 9 23:36:53 2010, Zach, Misc, GYRO, gyro noise budget updated in SVN 
Entry  Fri Sep 10 18:18:03 2010, Zach, Laser, GYRO, gyro taking data 
Entry  Fri Sep 10 19:10:02 2010, Zach, Laser, GYRO, Gyro displacement noise analysis disp_noise_analysis.pdf
Entry  Fri Sep 10 20:02:09 2010, Zach, Laser, GYRO, Refcav stabilization idea added to GyroDoc 
Entry  Fri Sep 10 16:33:38 2010, Frank, Computing, General, arp scan for ATF lab to update network diagram 
    Reply  Sat Sep 11 03:22:22 2010, rana, Computing, General, arp scan for ATF lab to update network diagram 
Entry  Sun Sep 12 01:24:38 2010, Zach, Laser, GYRO, new gyro noise spectrum gyro_noise_with_contribs_9_11_10.png
Entry  Thu Sep 9 00:22:14 2010, Dmass, Electronics, stuff happens, Newport 3040 fukt? 
    Reply  Thu Sep 9 05:17:19 2010, Dmass, Electronics, stuff happens, Who cares! 
       Reply  Thu Sep 9 18:31:48 2010, Dmass, Electronics, stuff happens, Who cares! 
          Reply  Thu Sep 9 21:12:50 2010, Dmass, Electronics, stuff happens, Router Crashed again? 
             Reply  Thu Sep 9 21:45:26 2010, Dmass, Electronics, stuff happens, Router Crashed again? 
                Reply  Thu Sep 9 21:56:29 2010, Dmass, Electronics, stuff happens, Can't get data from 40m network? 
                Reply  Thu Sep 9 21:57:37 2010, Frank, Electronics, stuff happens, Router Crashed again? 
                   Reply  Thu Sep 9 22:38:06 2010, Zach, Electronics, stuff happens, Router Crashed again? 
          Reply  Fri Sep 10 01:03:21 2010, Dmass, Electronics, stuff happens, Who cares! 
             Reply  Fri Sep 10 01:24:41 2010, Dmass, Electronics, stuff happens, SR560 needed 
             Reply  Fri Sep 10 16:32:32 2010, Dmass, Electronics, stuff happens, Who cares! 
                Reply  Mon Sep 13 21:34:47 2010, Dmass, Electronics, Doubling, Final Spectra: HEPA Test MZPhaseNoiseHEPASpectest.pngOvenHEPATempSpec.png
Entry  Mon Sep 13 22:01:11 2010, Zach, Laser, GYRO, frustrating GYRO realizations trans_and_AOM_uncal.pngtrans_and_AOM_calibrated.png
Entry  Wed Sep 15 20:09:09 2010, Zach, Laser, GYRO, Updated SVN noise budget 
Entry  Wed Sep 15 18:33:58 2010, Alastair, Laser, General, What's up with the 808nm? 
    Reply  Wed Sep 15 22:10:46 2010, rana, Laser, General, What's up with the 808nm? 
    Reply  Wed Sep 15 22:54:03 2010, Frank, Laser, General, What's up with the 808nm? 
Entry  Wed Sep 15 23:23:30 2010, Frank, Laser, General, 35W Laser ON 
Entry  Thu Sep 16 12:53:31 2010, Alastair, Lab Infrastructure, General, Seismometer now measuring photo_2.jpgphoto_3.JPGphoto_1.JPGIMG_0121.jpg
Entry  Thu Sep 16 22:35:17 2010, Zach, Laser, GYRO, Gyro CCW open-loop TF CCW_OLTF.pngarbcav_spect.pngTEK00007.PNG
Entry  Fri Sep 17 17:25:32 2010, Frank, Laser, Pulser, remaining power in PC "OFF"-state remains_360uW.bmpremains_130mW.bmp
Entry  Sun Sep 19 16:23:19 2010, Zach & Alastair, Electronics, GYRO, changes to PDH box #1437 and current CCW OLTF PDH_1437_9_18_10.pngCCW_OLTF_9_18_10.pngres_zoom.pngCCW_OLTF_notch_9_18_10.png
Entry  Mon Sep 20 13:29:53 2010, rana, Computing, Computing, ws1 device query (this is very uninteresting) 
Entry  Mon Sep 20 13:41:33 2010, rana, Computing, fubar, router was down so I power cycled it 
Entry  Mon Sep 20 14:07:37 2010, rana, Computing, Computing, WS1: video settings fixed to have dual head Xinerama 
Entry  Sun Sep 19 16:27:35 2010, Zach & Alastair, Electronics, GYRO, Gyro RFPD dimensions RFPD_drawing.png
    Reply  Sun Sep 19 20:45:39 2010, rana, Electronics, GYRO, Gyro RFPD 
       Reply  Mon Sep 20 14:41:14 2010, Zach, Electronics, GYRO, Gyro RFPD 
          Reply  Mon Sep 20 15:30:22 2010, Alastair, Electronics, GYRO, Gyro RFPD 
             Reply  Mon Sep 20 15:47:49 2010, Zach, Electronics, GYRO, Gyro RFPD 
Entry  Mon Sep 20 22:47:27 2010, Alastair, Misc, fubar, liso 
Entry  Wed Sep 22 00:58:47 2010, Zach, Electronics, GYRO, RFPD LISO model gyro_PD_TF.pnggyro_PD_noise.png
Entry  Tue Sep 21 17:11:12 2010, Alastair, Electronics, GYRO, pdh box re-modifying 6x
    Reply  Wed Sep 22 15:16:07 2010, Alastair, Electronics, GYRO, pdh box re-modifying 
       Reply  Wed Sep 22 17:03:24 2010, Alastair, Electronics, GYRO, pdh box re-modifying amplitude.pngphase.png
Entry  Thu Sep 23 17:45:56 2010, Alastair & Zach, Electronics, GYRO, pdh box 1 mods pdh1ampl.pngpdh1phase.png
Entry  Thu Sep 23 22:07:55 2010, Zach & Alastair, Laser, GYRO, CCW OLTF CCW_OLTF_9_23_10.pngCCW_OLTF_notch_9_23_10.png
Entry  Tue Sep 28 22:47:38 2010, Alastair, Computing, General, New ATF Wiki 
Entry  Tue Sep 28 13:53:08 2010, Zach & Alastair, Laser, GYRO, current gyro noise spectrum gyro_noise_with_varying_CCW_G.pdf
    Reply  Tue Sep 28 14:12:45 2010, Koji, Laser, GYRO, current gyro noise spectrum 
       Reply  Tue Sep 28 14:42:21 2010, Zach, Laser, GYRO, current gyro noise spectrum 
          Reply  Tue Sep 28 23:04:38 2010, Zach, Laser, GYRO, current gyro noise spectrum gyro_noise_with_varying_CCW_G_9_28_10.png
Entry  Wed Sep 29 11:56:04 2010, Alastair, Computing, General, ATF wiki 
    Reply  Wed Sep 29 13:36:57 2010, Alastair, Computing, General, ATF wiki 
Entry  Wed Sep 29 16:45:23 2010, Zach, Computing, DAQ, acquired channel 
Entry  Thu Sep 30 00:25:31 2010, Zach, Electronics, GYRO, VCO deviation measurements tektronix_47p5.pngmarconi_47p5.pngmarconi_95.png
Entry  Thu Sep 30 01:01:04 2010, Zach, Laser, GYRO, variation of Alastair's VCO-swap measurement, re-thoughts about readout schemes gyro_noise_AOM_act_marconi_9_29_10.png
Entry  Thu Sep 30 19:26:57 2010, Zach, Computing, DAQ, DAQ appears #&*@ed 
    Reply  Thu Sep 30 21:09:43 2010, Zach, Computing, DAQ, DAQ appears #&*@ed 
Entry  Fri Oct 1 02:02:23 2010, Zach, Laser, GYRO, CCW-CW crosstalk servo_diagram_dot.png
Entry  Fri Oct 1 11:53:04 2010, Alastair, Computing, Computing, no chans in dataviewer 
    Reply  Fri Oct 1 12:28:53 2010, Alastair, Computing, Computing, no chans in dataviewer 
    Reply  Fri Oct 1 13:04:44 2010, Frank, Computing, Computing, no chans in dataviewer 
Entry  Fri Oct 1 21:58:29 2010, Alastair, Computing, Computing, wiki 
Entry  Mon Oct 4 15:29:01 2010, Alastair, Lab Infrastructure, General, Laser chiller 
Entry  Mon Oct 4 23:50:12 2010, Zach, Laser, GYRO, CCW-CW crosstalk measurements f_noise_CCW-err_vs_CW-act.pngCCW-CW_err_10_4_10.pdf
Entry  Tue Oct 5 12:53:26 2010, Aidan, Computing, General, Added link to the users directory in the root directory on ws1 
Entry  Wed Oct 6 00:32:45 2010, rana, Computing, DAQ, Network Data Server 
Entry  Wed Oct 6 12:23:44 2010, Alastair, Computing, General, Installed matlab on WS2 
Entry  Wed Oct 6 15:26:56 2010, Alastair, Lab Infrastructure, ANTS!, insecticide on floor 
Entry  Wed Oct 6 17:06:45 2010, Frank, Misc, Pulser, Keithley 2635A i-v curve config files pd_darkcurrent_100mV_-20V_range1uA_limit1uA.prj
Entry  Fri Oct 8 19:59:00 2010, Alastair, Misc, GYRO, Seimometer set up on top of bench / SR560 borrowed from DAQ input channel 13 GYRO 
Entry  Wed Oct 13 10:08:48 2010, Alastair, Computing, Computing, Network diagram 
Entry  Wed Oct 20 18:43:48 2010, Alastair, Computing, Computing, ATF FB0 front-end rebuild 
Entry  Wed Oct 20 23:49:54 2010, Alastair, Computing, Computing, DAQ continued 
    Reply  Thu Oct 21 12:17:54 2010, Frank, Computing, Computing, DAQ continued 
Entry  Fri Oct 22 10:56:51 2010, Rana & Alastair, Computing, Computing, front-end now working 
Entry  Sun Oct 24 19:27:44 2010, rana, Computing, Computing, Now running ELOG 2.8.0 
Entry  Thu Oct 28 18:52:16 2010, Zach, Laser, General, Lasers were turned off last night for PMA work 
Entry  Fri Oct 29 15:34:36 2010, Zach & Koji, Laser, GYRO, CCW loop characterization bart-simpson-generator.png
    Reply  Sat Oct 30 20:02:01 2010, Koji, Laser, GYRO, gyro characterization Oct 27, 2010 (1) open_loop_primary.pdf
       Reply  Sat Oct 30 20:18:06 2010, Koji, Laser, GYRO, gyro characterization Oct 27, 2010 (2) error_primary.pdffeedback_primary.pdf
          Reply  Sat Oct 30 20:57:19 2010, Koji, Laser, GYRO, gyro characterization Oct 27, 2010 (3) error_secondary.pdf
             Reply  Sat Oct 30 22:49:04 2010, Koji, Laser, GYRO, gyro characterization Oct 27, 2010 (4) 
                Reply  Sat Oct 30 23:41:31 2010, Koji, Laser, GYRO, gyro characterization Oct 27, 2010 (5) 
Entry  Fri Oct 29 17:31:41 2010, Alastair, Lab Infrastructure, fubar, Old white board photo.JPG
    Reply  Sat Oct 30 14:09:20 2010, Curious George, Lab Infrastructure, fubar, Old white board 
       Reply  Mon Nov 1 16:35:15 2010, Alastair, Lab Infrastructure, fubar, Old white board 
Entry  Mon Nov 1 19:46:05 2010, Zach, Misc, Computing, floppy disk cleared 
Entry  Mon Nov 1 22:25:48 2010, Frank, Laser, General, 35W laser ON 
Entry  Tue Nov 2 22:36:35 2010, Zach, Electronics, GYRO, PDH schematic updated in-inmon_gain.png
Entry  Tue Nov 2 22:40:31 2010, Zach, Electronics, GYRO, BLP-1.9+ BLP-1p9plus.png
Entry  Tue Nov 2 23:01:45 2010, Zach, Laser, GYRO, PDA10A (REFL CCW PD) intensity noise analysis PDA10A_W_noise.png
Entry  Tue Nov 2 23:20:07 2010, Zach, Laser, GYRO, List of things to do 
Entry  Wed Nov 3 01:27:26 2010, Koji, Laser, GYRO, in response to the elog entries 1126-1130 
Entry  Wed Nov 3 18:18:19 2010, Frank, Misc, General, Thin film and bulk index of refraction and photonics calculations - web page 
Entry  Tue Nov 2 19:22:56 2010, Alastair, Computing, Computing, DAQ Screenshot.png
    Reply  Wed Nov 3 19:00:45 2010, Alastair, Computing, Computing, DAQ Screenshot.png
Entry  Tue Nov 2 22:47:35 2010, Zach, Electronics, GYRO, demodulation noise analysis demod_noise.png
    Reply  Wed Nov 3 20:25:01 2010, Zach, Electronics, GYRO, demodulation noise analysis demod_noise.png
Entry  Wed Nov 3 20:40:20 2010, Zach, Electronics, GYRO, SLP-1.9+ audio TF SLP-1.9plus_audio_tf
Entry  Wed Nov 3 20:45:29 2010, Zach, Electronics, GYRO, PDH box IN -> INMON TF in_inmon_tf.png
Entry  Wed Nov 3 20:52:14 2010, Zach, Electronics, GYRO, PDH box #1437 gain vs. gain knob setting PDH_1437_gain_knob_cal.png
Entry  Thu Nov 4 22:18:31 2010, Alastair, Computing, Computing, Changes to model 
Entry  Thu Nov 4 23:22:53 2010, Zach, Computing, Computing, why is the elog so slow? 
Entry  Fri Nov 5 00:59:57 2010, Frank, Misc, Pulser, no results so far 
Entry  Fri Nov 5 01:19:42 2010, Frank, Misc, Pulser, setup schematic and program screenshot pd-pulse-test_v3.pngLabview_screenshot.png
Entry  Sat Nov 6 01:19:50 2010, Frank, Misc, Pulser, increased pulse energy to 250mJ damage.jpg
Entry  Sat Nov 6 23:48:02 2010, rana, Computing, Computing, ws1 is back, almost 
Entry  Sun Nov 7 15:13:29 2010, Frank, Computing, Pulser, netbook frozen 
Entry  Mon Nov 8 00:15:21 2010, Zach, Laser, GYRO, primary loop self-consistency check fnoise_self-check.png
Entry  Mon Nov 8 00:21:43 2010, Zach, Laser, GYRO, Primary loop unsuppressed frequency noise unsup_freq_noise.png
Entry  Mon Nov 8 11:42:03 2010, Frank, Computing, Pulser, Netbook frozen again 
Entry  Mon Nov 8 13:42:06 2010, Frank, Misc, Pulser, increased pulse energy again 
Entry  Mon Nov 8 17:18:14 2010, Zach, Laser, GYRO, electronic noise contributions e-noise_contribs.png
Entry  Sun Nov 7 21:47:10 2010, rana, Computing, Computing, fb0/fb1 user ID and group ID changed to controls=1001 
    Reply  Mon Nov 8 17:26:38 2010, rana, Computing, Computing, fb0/fb1 user ID and group ID changed to controls=1001 
       Reply  Mon Nov 8 22:37:33 2010, rana, Computing, Computing, fb0/fb1 user ID and group ID changed to controls=1001 Untitled.png
Entry  Tue Nov 9 01:38:50 2010, Zach, Laser, GYRO, Tektronix VCO / NPRO PZT actuation calibration FM_fit_1k.pngFM_fit_100.png
Entry  Tue Nov 9 02:18:36 2010, alastair, Computing, Computing, router ordered 
Entry  Tue Nov 9 12:57:30 2010, Zach, Electronics, GYRO, Primary PDH box noise assessment 1437_noise_assessment.pngScreen_shot_2010-11-09_at_12.42.38_PM.png
Entry  Wed Nov 10 01:15:34 2010, Alastair, Computing, Computing, Wiki is down... 
    Reply  Wed Nov 10 01:21:49 2010, Koji, Computing, Computing, Wiki is down... 
       Reply  Wed Nov 10 01:46:53 2010, Alastair, Computing, Computing, Wiki is down... 
          Reply  Wed Nov 10 01:52:22 2010, Alastair, Computing, Computing, Wiki is down... 
Entry  Wed Nov 10 11:28:34 2010, Zach, Laser, GYRO, PDA255 noise PDA255.png
    Reply  Wed Nov 10 18:49:01 2010, rana, Laser, GYRO, PDA255 noise 
Entry  Thu Nov 11 01:37:35 2010, Frank, Misc, Pulser, diode blasting setup changed - added CCD camera setup.jpg100_1147.JPG100_1140.JPG
Entry  Thu Nov 11 23:15:14 2010, Zach, Laser, GYRO, update 
Entry  Thu Nov 11 23:53:12 2010, Zach, Laser, GYRO, TO DO 
Entry  Fri Nov 12 12:56:47 2010, Zach, Laser, GYRO, time-varying RFAM RFAM_setup.jpg
Entry  Fri Nov 12 17:56:48 2010, Zach, Electronics, GYRO, channels acquired 
    Reply  Fri Nov 12 23:12:18 2010, Alastair, Electronics, GYRO, channels acquired 
       Reply  Sat Nov 13 11:37:03 2010, Zach, Electronics, GYRO, channels acquired 
Entry  Mon Nov 15 23:03:39 2010, Zach, Laser, GYRO, RFAM err_drift.pngTEK00000.PNG
Entry  Thu Nov 18 09:27:18 2010, Koji, Laser, GYRO, RFAM & Sprious RF coupling  cabling.jpgreduction.jpgIMG_3714.jpgIMG_3715.jpg
Entry  Fri Nov 19 20:09:57 2010, Zach, Laser, GYRO, realignment, etc 
    Reply  Sat Nov 20 15:02:05 2010, rana, Laser, GYRO, realignment, etc 
       Reply  Sun Nov 21 16:24:06 2010, Zach, Laser, GYRO, realignment, etc EOM_TF.pngEOM_sweep_setup.png
Entry  Tue Nov 23 11:55:04 2010, Zach, Laser, GYRO, backscatter problem 
Entry  Tue Nov 23 23:36:12 2010, Frank, Misc, Pulser, added digital camera readout 
Entry  Wed Nov 24 23:57:13 2010, Frank, Misc, Pulser, improved setup finished 
Entry  Fri Nov 26 13:00:20 2010, Zach, Laser, GYRO, Gyro OLTFs and current noise spectrum oltfs_11_23_10.pnggnoise_11_23_10.png
    Reply  Fri Nov 26 19:43:34 2010, Koji, Laser, GYRO, Gyro OLTFs and current noise spectrum 
Entry  Mon Nov 29 19:42:23 2010, Alastair, Electronics, GYRO, photodiode plans photodiode_diagram.pdf
Entry  Mon Nov 29 20:29:57 2010, Zach, Computing, DAQ, issues 
    Reply  Mon Nov 29 22:01:29 2010, Alastair, Computing, DAQ, issues 
Entry  Tue Nov 30 11:03:55 2010, Alastair, Things to Buy, GYRO, vacuum gauge for gyro system 
Entry  Tue Nov 30 12:59:16 2010, Frank, Computing, Pulser, switched computers for pulsing experiment 
Entry  Tue Nov 30 19:03:21 2010, Frank, Computing, DAQ, fb0 working again - fsck forced 
Entry  Wed Dec 1 02:01:34 2010, Frank, Computing, Pulser, Camera problems on IBM computer 
Entry  Wed Dec 1 13:34:04 2010, Zach, Laser, GYRO, current gyro noise budget gyro_nb_12_1_10.png
Entry  Thu Dec 2 16:03:01 2010, Frank, Computing, DAQ, external framebuilder acces to fb0 fixed 
Entry  Thu Dec 2 17:11:36 2010, Frank, Computing, Pulser, hardware & software updates 
Entry  Mon Dec 6 16:31:15 2010, Zach, Laser, GYRO, CCW-CW noise spillover analysis CCW-CW_spillover_12_6_10.png
Entry  Thu Dec 2 15:48:05 2010, Alastair, Computing, Purchases, The router saga continues 
    Reply  Fri Dec 3 12:16:10 2010, Alastair, Computing, Purchases, The router saga continues 
       Reply  Tue Dec 7 15:05:25 2010, Alastair, Computing, Purchases, new router has arrived 
Entry  Tue Dec 7 00:19:26 2010, Zach, Laser, GYRO, noise budget-O-matic NoiseBudget.pdf
    Reply  Wed Dec 8 01:13:31 2010, Zach, Laser, GYRO, noise budget-O-matic noise_spect_consistency_check.pngNoiseBudget.pdf
       Reply  Wed Dec 8 11:37:17 2010, Zach, Laser, GYRO, noise budget-O-matic NoiseBudget.pdf
Entry  Wed Dec 8 22:22:51 2010, Koji, Laser, GYRO, Gyro relocked  
Entry  Thu Dec 9 02:53:22 2010, Koji, Laser, GYRO, Double Hacky? Trio? Even Hacky quartet! Gyro_Spectra_101208.pdf100_1158.jpg100_1162.jpg
Entry  Wed Dec 8 17:57:46 2010, Frank, Lab Infrastructure, General, Whiteboard installation on Monday 
    Reply  Thu Dec 9 20:55:50 2010, Zach, Lab Infrastructure, General, Whiteboard installation on Monday 
Entry  Thu Dec 9 21:10:24 2010, Alastair, Laser, GYRO, Wind breaker bench_layout.pdf
Entry  Wed Dec 8 22:16:00 2010, Zach, Electronics, GYRO, EOM resonant circuit test eom_circuit_schematic.pngeom_res_circuit_tf.png
    Reply  Thu Dec 9 23:07:46 2010, Zach, Electronics, GYRO, EOM resonant circuit test EOM_res_circuit_TF_12_9_10.png
Entry  Fri Dec 10 11:08:41 2010, Alastair, Computing, General, Sitemap working again for gyro 
Entry  Fri Dec 10 10:46:11 2010, Zach, Computing, DAQ, busted again! 
    Reply  Fri Dec 10 11:21:14 2010, Alastair, Computing, DAQ, busted again! 
       Reply  Fri Dec 10 11:44:05 2010, Alastair, Computing, DAQ, busted again! 
Entry  Fri Dec 10 10:33:46 2010, Zach, Laser, GYRO, update 
    Reply  Fri Dec 10 13:43:07 2010, Koji, Laser, GYRO, update 
Entry  Mon Dec 13 11:28:32 2010, Zach, Computing, DAQ, help 
Entry  Mon Dec 13 23:55:06 2010, Zach, Laser, GYRO, gyro signal noise comparison (AOM FB vs. PLL FB) gyro_signal_comparison.pngfoiled_again.jpg
    Reply  Tue Dec 14 04:23:03 2010, rana, Laser, GYRO, gyro signal noise comparison (AOM FB vs. PLL FB) 
       Reply  Tue Dec 14 09:30:52 2010, Zach, Laser, GYRO, gyro signal noise comparison (AOM FB vs. PLL FB) 
Entry  Tue Dec 14 17:02:56 2010, Alastair, Zach, Frank (and absolutely definitely no help from Joe), Computing, Computing, FB0 status update 
Entry  Wed Dec 15 00:49:11 2010, Frank, Computing, DAQ, fb1 fixed 
Entry  Wed Dec 15 01:20:03 2010, Frank, Computing, DAQ, cron-job added on fb1 for wiper script to delete old frame files 
Entry  Wed Dec 15 20:16:44 2010, Alastair, Computing, General, more on fb0 
    Reply  Wed Dec 15 20:35:18 2010, Alastair, Computing, General, more on fb0 
Entry  Thu Dec 16 10:46:36 2010, Zach, Electronics, GYRO, EOM circuit 400_ohms.png25_ohms.png
    Reply  Thu Dec 16 13:13:02 2010, Koji, Electronics, GYRO, EOM circuit 
       Reply  Thu Dec 16 19:46:39 2010, Zach, Electronics, GYRO, EOM circuit refl_signal_with_and_without_R.png
Entry  Wed Dec 15 15:41:45 2010, Alastair & Zach, Electronics, General, RFPD design RFPD_1.pdf
    Reply  Wed Dec 15 22:29:27 2010, Frank, Electronics, General, RFPD design 
       Reply  Wed Dec 15 22:36:05 2010, Alastair, Electronics, General, RFPD design 
    Reply  Thu Dec 16 03:50:33 2010, rana, Electronics, General, RFPD design: comments 
       Reply  Thu Dec 16 15:27:12 2010, Alastair, Electronics, General, RFPD design: comments 
       Reply  Fri Dec 17 22:07:00 2010, Alastair, Electronics, General, RFPD design: comments 
Entry  Mon Dec 20 00:49:55 2010, rana, Misc, stuff happens, trivia KEvsMOMENTUM.png
Entry  Thu Dec 16 19:25:27 2010, Zach, Misc, GYRO, Murphy's Law verified, science rejoices hanky.png
    Reply  Fri Dec 17 03:34:55 2010, rana, Misc, GYRO, Murphy's Law verified, science rejoices 
       Reply  Tue Dec 28 14:22:03 2010, Zach, Misc, GYRO, Murphy's Law verified, science rejoices 
Entry  Tue Jan 4 11:42:19 2011, Alastair, Misc, GYRO, Vacuum system 
Entry  Wed Jan 5 14:45:53 2011, Koji, Laser, MOPA, Chiller is crying 
    Reply  Wed Jan 5 15:37:18 2011, Frank, Laser, MOPA, Chiller is crying 
       Reply  Wed Jan 5 21:20:01 2011, Zach, Laser, MOPA, Chiller is crying 
Entry  Mon Jan 10 09:25:50 2011, Alastair, Misc, General, Michelson's interferometer michelson.jpg
Entry  Sat Jan 8 19:52:24 2011, Alastair, Electronics, GYRO, PD board design PCB_drawing_RFPD.pdfRFPD_schematic.pdf
    Reply  Mon Jan 10 15:18:24 2011, Alastair, Electronics, GYRO, PD board design 
       Reply  Mon Jan 10 16:08:04 2011, Alastair, Electronics, GYRO, PD board design 
Entry  Tue Jan 11 11:07:41 2011, Alastair, Electronics, GYRO, PD board design Screen_shot_2011-01-11_at_11.02.04_AM.pngPerkin_Elmer.pdfPerkin_Elmer_PDs.pdf
Entry  Tue Jan 11 14:23:01 2011, Alastair & Zach, Laser, GYRO, Vacuum system 
Entry  Tue Jan 11 15:12:18 2011, Zach, Electronics, GYRO, PDH box #1437 reverted 
Entry  Tue Jan 11 18:26:54 2011, Zach, Laser, GYRO, Enhanced Gyro upgrade outline 
    Reply  Wed Jan 12 09:38:28 2011, Alastair, Laser, GYRO, Enhanced Gyro upgrade outline 
Entry  Wed Jan 12 16:48:06 2011, Zach, Laser, GYRO, Clean slate 2011-01-12_16.04.54.jpg2011-01-12_16.05.16.jpg
Entry  Thu Jan 13 15:34:32 2011, Alastair, Laser, GYRO, (no) Vaccum update 
Entry  Tue Jan 18 19:32:05 2011, Alastair, Laser, GYRO, Vacuum flanges 
Entry  Wed Jan 19 10:11:09 2011, Alastair, Laser, GYRO, PD boards sent for production 
Entry  Thu Jan 20 12:50:43 2011, Zach, Lab Infrastructure, Computing, fb0 put back into rack, moved to a better location fb0.png
Entry  Thu Jan 20 20:13:07 2011, Alastair, Laser, GYRO, Vacuum parts IMG_2371.JPGIMG_2388.JPG
Entry  Thu Jan 20 00:00:07 2011, Zach, Electronics, GYRO, EOM circuit circuit_picture.pngimpedance_plot_1_19_11.png
    Reply  Thu Jan 20 17:04:42 2011, Zach, Electronics, GYRO, EOM circuit impedance_plot_1_20_11.png
       Reply  Fri Jan 21 18:15:58 2011, Zach, Electronics, GYRO, EOM circuit impedance_plot_1_21_11.png
Entry  Tue Jan 25 15:34:05 2011, Alastair, Laser, GYRO, Chasing up orders/machine shop 
Entry  Wed Jan 26 10:38:10 2011, Alastair, Laser, GYRO, PD boards 
Entry  Wed Jan 26 14:48:02 2011, Alastair, Laser, GYRO, Flanges for vacuum 
Entry  Mon Jan 24 18:13:20 2011, Zach, Electronics, GYRO, PDH servo basic_design.png
    Reply  Tue Jan 25 00:05:57 2011, Koji, Electronics, GYRO, PDH servo 
       Reply  Tue Jan 25 01:30:01 2011, Zach, Electronics, GYRO, PDH servo PDH2.pdf
          Reply  Tue Jan 25 01:39:00 2011, Koji, Electronics, GYRO, PDH servo 
             Reply  Tue Jan 25 02:09:16 2011, Zach, Electronics, GYRO, PDH servo 
                Reply  Tue Jan 25 02:18:17 2011, Koji, Electronics, GYRO, PDH servo 
                   Reply  Wed Jan 26 01:20:10 2011, Zach, Electronics, GYRO, PDH servo PDH2.pdf
                      Reply  Wed Jan 26 06:20:03 2011, Koji, Electronics, GYRO, PDH servo 
                         Reply  Wed Jan 26 12:42:36 2011, Zach, Electronics, GYRO, PDH servo 
                            Reply  Wed Jan 26 18:10:37 2011, rana, Electronics, GYRO, PDH servo 
                               Reply  Wed Jan 26 19:47:42 2011, Zach, Electronics, GYRO, PDH servo PDH2.pdf
                                  Reply  Wed Jan 26 20:01:31 2011, Zach, Electronics, GYRO, PDH servo 
Entry  Fri Jan 28 04:12:26 2011, Zach, Laser, GYRO, shot-noise-limited locking scheme 11x
Entry  Sat Jan 22 19:54:20 2011, Zach, Electronics, GYRO, RFPD box PD_box.pdf
    Reply  Sat Jan 22 21:59:46 2011, Alastair, Electronics, GYRO, RFPD box 
       Reply  Sun Jan 23 12:17:45 2011, Zach, Electronics, GYRO, RFPD box 
          Reply  Mon Jan 24 00:47:54 2011, Koji, Electronics, GYRO, RFPD box 
             Reply  Mon Jan 24 12:06:14 2011, Zach, Electronics, GYRO, RFPD box 
                Reply  Mon Jan 24 12:57:15 2011, rana, Electronics, GYRO, RFPD box 
                   Reply  Mon Jan 24 13:16:01 2011, Zach, Electronics, GYRO, RFPD box 
                      Reply  Wed Jan 26 01:42:44 2011, Zach, Electronics, GYRO, RFPD box 
                         Reply  Fri Jan 28 17:40:28 2011, Zach, Electronics, GYRO, RFPD box PD_box.pdf
Entry  Wed Feb 2 20:36:52 2011, Zach, Electronics, GYRO, PD stuffed pd_stuffed.png
    Reply  Thu Feb 3 19:40:24 2011, Zach, Electronics, GYRO, PD stuffed 
Entry  Thu Feb 3 19:49:52 2011, rana, Computing, CDS, FB work ongoing 
    Reply  Thu Feb 3 22:24:21 2011, Frank, Computing, CDS, FB work ongoing 
Entry  Fri Feb 4 16:58:39 2011, Alastair, Laser, GYRO, Rb Clock data RbMeasurements.txt.zip
Entry  Fri Feb 4 22:45:48 2011, Frank, Computing, DAQ, hard drive failures 
Entry  Fri Feb 4 23:45:40 2011, Zach, Electronics, GYRO, RFPD board problem solved 
Entry  Fri Feb 4 19:38:49 2011, rana, joeB, Computing, DAQ, fb0 problems fixed: daqd, nds, and atffe all now running Untitled.png
    Reply  Mon Feb 7 12:59:11 2011, joeB, Computing, DAQ, fb0 problems fixed: daqd, nds, and atffe all now running 
Entry  Fri Feb 4 05:26:18 2011, Zach, Electronics, GYRO, PDH2 PCB layout PDH2.pdf
    Reply  Fri Feb 4 08:08:39 2011, Koji, Electronics, GYRO, PDH2 PCB layout 
       Reply  Fri Feb 4 14:56:38 2011, Zach, Electronics, GYRO, PDH2 PCB layout 
          Reply  Fri Feb 4 20:23:13 2011, Koji, Electronics, GYRO, PDH2 PCB layout 
             Reply  Mon Feb 7 13:37:31 2011, Zach, Electronics, GYRO, PDH2 PCB layout 
Entry  Tue Feb 8 21:28:33 2011, Alastair & Co., Computing, Computing, FB0 issues.... 
Entry  Wed Feb 9 01:35:06 2011, Zach, Laser, GYRO, gyro RFPD transfer function (sort of) plotlog.pngplotlin.png
Entry  Wed Feb 9 20:13:46 2011, Zach, Electronics, GYRO, PD boxes ordered 
Entry  Thu Feb 10 13:00:28 2011, Zach, Computing, DAQ, everything is working again 
    Reply  Thu Feb 10 16:11:56 2011, Alastair, Computing, DAQ, everything is working again 
       Reply  Thu Feb 10 16:28:24 2011, Frank, Computing, DAQ, everything is working again 
          Reply  Thu Feb 10 19:04:14 2011, Zach, Computing, DAQ, everything is working again 
             Reply  Thu Feb 10 22:03:03 2011, Frank, Computing, DAQ, everything is working again 
Entry  Tue Feb 15 00:15:28 2011, Zach, Laser, GYRO, gyro upgrade progress  gyro_status_2_14_11.png
Entry  Tue Feb 15 02:02:53 2011, Zach, Electronics, GYRO, Universal PDH box noise problem identified 
    Reply  Tue Feb 15 09:12:11 2011, Koji, Electronics, GYRO, Universal PDH box noise problem identified 
       Reply  Tue Feb 15 11:16:29 2011, Zach, Electronics, GYRO, Universal PDH box noise problem identified Screen_shot_2011-02-15_at_11.09.41_AM.png
          Reply  Tue Feb 15 11:34:48 2011, Frank, Electronics, GYRO, Universal PDH box noise problem identified 
             Reply  Tue Feb 15 12:08:33 2011, Zach, Electronics, GYRO, Universal PDH box noise problem identified,  
Entry  Wed Feb 16 00:18:27 2011, Zach, Laser, GYRO, AOM set up, CCW and CW beams power-balanced @ ~80 mW AOM_mm_ABCD.pnggyro_as_of_2_15_11.pngaom_path_profile.png
Entry  Wed Feb 16 16:47:17 2011, Zach, Laser, GYRO, Gyro beams profiled full_beam_scan_2_16_11.png
Entry  Fri Feb 18 00:02:54 2011, Zach, Laser, GYRO, optical layout finalized table_layout.pnginjection_setup2.pnginjection_setup.png
Entry  Fri Feb 18 00:09:55 2011, Zach, Laser, GYRO, gyro upgrade progress (repost) table_layout.png
Entry  Fri Feb 18 20:07:44 2011, Zach, Laser, GYRO, MZ measurement in progress 
Entry  Sat Feb 19 03:22:21 2011, Frank, Electronics, General, cable phase noise 
Entry  Sun Feb 20 23:21:45 2011, Zach, Laser, GYRO, MZ noise half-analysis Screen_shot_2011-02-18_at_7.36.10_PM.pngScreen_shot_2011-02-20_at_3.00.34_PM.pngScreen_shot_2011-02-20_at_3.00.46_PM.pngScreen_shot_2011-02-20_at_6.39.24_PM.png
Entry  Mon Feb 21 11:41:07 2011, Zach, Laser, GYRO, other half of MZ noise analysis gyro_MZ_noise_2_21_11.png
    Reply  Mon Feb 21 22:08:13 2011, rana, Laser, GYRO, other half of MZ noise analysis 
Entry  Tue Feb 22 00:25:39 2011, Zach, Laser, GYRO, mode matching issue 
    Reply  Tue Feb 22 10:47:35 2011, Alastair?, Laser, GYRO, mode matching issue 
       Reply  Tue Feb 22 11:21:01 2011, Zach, Laser, GYRO, mode matching issue 
Entry  Wed Feb 23 01:22:09 2011, Zach, Laser, GYRO, PD boxes in! gyro_pd1.pnggyro_pd2.pnggyro_pd3.png
Entry  Mon Feb 21 23:17:46 2011, Zach, Electronics, GYRO, PDH box #1437 modified 1437_mod.jpgpdh1437_temp_innoise.png
    Reply  Wed Feb 23 01:40:03 2011, Zach, Electronics, GYRO, PDH box #1437 modified pdh1437_temp_tf.pngpdh1437temp_vs_liso.png
       Reply  Wed Feb 23 15:33:32 2011, Zach, Electronics, GYRO, PDH box #1437 modified pdh1437temp_vs_liso_with_SA_noise.png
Entry  Thu Feb 24 01:29:09 2011, Zach, Electronics, GYRO, RFPD #01 TF rfpd_vs_liso_log.png
    Reply  Thu Feb 24 03:54:29 2011, Frank, Electronics, GYRO, RFPD #01 TF 
Entry  Mon Feb 28 17:47:33 2011, Aidan, Computing, DAQ, Restarted DAQD on fb1 
Entry  Tue Mar 1 21:40:49 2011, Alastair, Computing, Computing, Wiki 
Entry  Wed Mar 2 01:57:07 2011, Zach, Laser, GYRO, gyro locked with new RFPD newpd1.pngnewpd2.png
Entry  Wed Mar 2 11:01:13 2011, Frank, Lab Infrastructure, General, SOPs missing 
    Reply  Wed Mar 2 11:32:08 2011, Zach, Lab Infrastructure, General, SOPs missing 
       Reply  Wed Mar 2 13:11:23 2011, Frank, Lab Infrastructure, General, SOPs missing 
Entry  Wed Mar 2 15:44:36 2011, Frank, Laser, MOPA, 35W-laser SOP (LIGO-M070352) 35W-SOP.pdf35W-SOP.doc
Entry  Wed Mar 2 09:14:01 2011, ghostwriter, Misc, fubar, dump or optics lab? 100_1229.JPG100_1228.JPG100_1227.JPG100_1226.JPG100_1230.JPG
    Reply  Thu Mar 3 00:36:11 2011, Zach, Misc, fubar, dump or optics lab? lab_is_clean.png
Entry  Thu Mar 3 00:59:29 2011, Zach, Laser, GYRO, upgrade continues SMP_SMA.pngPD_with_back1.pngPD_with_back2.pngsignals.png
Entry  Fri Mar 4 01:17:24 2011, Zach, Electronics, GYRO, temporary PDH servo 6x
    Reply  Fri Mar 4 02:06:22 2011, rana, Electronics, GYRO, temporary PDH servo 
       Reply  Fri Mar 4 02:36:42 2011, Zach, Electronics, GYRO, temporary PDH servo 
Entry  Sun Mar 6 00:43:02 2011, Zach , Electronics, GYRO, RFPD #02 TF rfpd02_vs_liso.png
Entry  Sun Mar 6 15:38:15 2011, Zach , Laser, GYRO, more noise analysis -- optical gain problem rfpd01_noise.pngerr_sig_evol.png
Entry  Mon Mar 7 12:46:38 2011, Alastair, Laser, GYRO, Vacuum pumpdown pumpdown.eps
Entry  Mon Mar 7 15:53:43 2011, Alastair, Laser, GYRO, Vacuum pumpdown part 2... pumpdown2.eps
Entry  Mon Mar 7 19:16:26 2011, Zach , Laser, GYRO, vacuum = better prim_error_signal_air_vs_vacuum_3_7_11.png
Entry  Tue Mar 8 11:17:54 2011, Alastair, Laser, General, RF amplifiers 
    Reply  Wed Mar 9 09:31:50 2011, rana, Laser, Purchases, RF amplifiers : Cougars 
Entry  Sat Mar 12 05:32:40 2011, Zach, Laser, GYRO, current gyro noise gyro_noise_with_contribs_3_11_11.pngoutput_box.pnginput_box.png
    Reply  Sat Mar 12 16:11:35 2011, Koji, Laser, GYRO, current gyro noise 
       Reply  Sat Mar 12 16:22:53 2011, Zach, Laser, GYRO, current gyro noise 
          Reply  Sat Mar 12 19:20:19 2011, Koji, Laser, GYRO, current gyro noise 
             Reply  Sat Mar 12 21:24:14 2011, Zach, Laser, GYRO, current gyro noise OLTFs_3_11_11.png
                Reply  Sun Mar 13 00:27:29 2011, Koji, Laser, GYRO, current gyro noise 
Entry  Sun Mar 13 15:47:47 2011, Alastair, Laser, GYRO, Some parts we made... IMG_2769.JPGIMG_2776.jpgIMG_2790.jpgIMG_2838.JPG
Entry  Tue Mar 15 00:30:46 2011, Zach, Laser, stuff happens, recent gyro plots are LIES 
    Reply  Tue Mar 15 12:34:33 2011, Alastair, Laser, stuff happens, recent gyro plots are LIES 
Entry  Thu Mar 17 11:55:08 2011, rana, Computing, Computing, coconutBattery coco.png
Entry  Thu Mar 17 15:09:18 2011, Aidan, Misc, stuff happens, LVC Lab Tour P1000411.JPGP1000412.JPGP1000413.JPG
Entry  Tue Mar 22 00:12:31 2011, Zach, Lab Infrastructure, GYRO, rack & cable routing reorganized rack_full.pngrack.pngmore_room.png
    Reply  Tue Mar 22 09:46:45 2011, Alastair, Lab Infrastructure, GYRO, rack & cable routing reorganized complex_conjugate.png
Entry  Wed Mar 23 10:48:20 2011, josephb, Computing, CDS, CDS stuff yesterday 
    Reply  Wed Mar 23 18:02:54 2011, alastair, Computing, CDS, CDS stuff yesterday 
Entry  Wed Mar 23 01:14:27 2011, Zach, Laser, GYRO, signal routing finished, gyro locked table.pngscope.pngrack.pnglid_hole.png
    Reply  Thu Mar 24 09:07:17 2011, Alastair & Zach, Laser, GYRO, RFAM re-measured full_spectrum_RFAM.png5_MHz_to_35_MHz.png
       Reply  Thu Mar 24 11:35:38 2011, rana, Laser, GYRO, RFAM re-measured 
Entry  Tue Mar 29 02:10:30 2011, Zach, Laser, GYRO, new HOM structure calculated new_TR_spect.pngnew_HOM_spect.png
Entry  Wed Mar 30 20:30:45 2011, Zach, Electronics, GYRO, TRANS PD tuned and REFL PDs retuned tf03.pngREFL_TFs.png
Entry  Wed Mar 30 14:12:10 2011, Alastair, Electronics, GYRO, Trans PD 100MHz_PD.pngPD_trans.fil.tar
    Reply  Thu Mar 31 00:33:36 2011, Frank, Electronics, GYRO, Trans PD 
       Reply  Thu Mar 31 11:25:43 2011, Alastair, Electronics, GYRO, Trans PD PD_trans.fil.tar
Entry  Thu Mar 31 21:51:16 2011, Zach, Laser, GYRO, gyro relocked 
Entry  Fri Apr 1 15:17:28 2011, Blaster, Misc, Pulser, pulser is running 
    Reply  Fri Apr 1 15:51:50 2011, Zach, Misc, Pulser, pulser is running 
Entry  Fri Apr 1 14:09:27 2011, Alastair, Electronics, GYRO, Trans PD measured 100_MHz_PD.png
    Reply  Fri Apr 1 14:13:02 2011, Zach, Electronics, GYRO, Trans PD measured 
       Reply  Fri Apr 1 14:31:46 2011, Joker, Electronics, GYRO, Trans PD measured 
    Reply  Fri Apr 1 15:54:28 2011, rana, Electronics, GYRO, Trans PD measured 
       Reply  Fri Apr 1 20:28:23 2011, Alastair, Electronics, GYRO, Trans PD measured 
          Reply  Sat Apr 2 03:24:12 2011, rana, Electronics, GYRO, Trans PD measured 
Entry  Mon Apr 4 15:30:22 2011, Frank, Misc, Pulser, two movies from diode blasting 
Entry  Tue Apr 5 23:57:40 2011, Zach, Laser, GYRO, new noise spectrum, some good news gyro_noise_4_5_11.pdf
    Reply  Wed Apr 6 01:23:15 2011, rana, Laser, GYRO, RAM estimate 
       Reply  Wed Apr 6 02:08:01 2011, Zach, Laser, GYRO, RAM estimate 
Entry  Thu Apr 7 01:13:57 2011, Zach, Laser, GYRO, Houston, we have sidebands TEK00006.PNGTEK00008.PNG
    Reply  Thu Apr 7 14:07:54 2011, No Name, Laser, GYRO, Houston, we have sidebands polarized_081122_1405.png
Entry  Fri Apr 8 02:27:34 2011, Zach, Laser, GYRO, PBS removed, no low-frequency improvement removed_PBS.pnggyro_noise_4_7_11.pdf
Entry  Fri Apr 8 12:52:50 2011, Alastair, Laser, GYRO, Cavity mirrors 
    Reply  Mon Apr 11 14:48:00 2011, Alastair, Laser, GYRO, Cavity mirrors 
Entry  Mon Apr 11 16:44:46 2011, Zach, Laser, GYRO, oscillator phase noise measurements gyro_noise_with_phase_noise_contribs_4_8_11.pdf
    Reply  Mon Apr 11 17:07:54 2011, Alastair, Laser, GYRO, oscillator phase noise measurements 
Entry  Tue Apr 12 22:47:38 2011, Aidan, Computing, DAQ, Added TCS channels and restarted daqd 
Entry  Tue Apr 12 23:17:51 2011, Zach, Laser, GYRO, thought I had it! CW_RFAM_4_12_11.pngtwo_eoms.pngtwo_eoms_4_12_11.png
Entry  Wed Apr 13 14:58:12 2011, Alastair, Electronics, GYRO, Trans PD final design transimpedance.pngScreen_shot_2011-04-13_at_2.55.30_PM.pngScreen_shot_2011-04-13_at_2.55.48_PM.png
Entry  Wed Apr 13 17:44:14 2011, Alastair, Electronics, GYRO, Trans PD values 
Entry  Thu Apr 14 22:59:15 2011, Zach, Electronics, GYRO, PD S/N 03 TF PD3_TF.pngPD3_tuning.pngPD3_tuning_zoom.png
Entry  Fri Apr 15 14:44:15 2011, Zach, Laser, GYRO, EOM AM/PM TEK00009.PNGTEK00010.PNG
Entry  Thu Apr 21 02:45:28 2011, Zach, Laser, GYRO, LF noise hunting 
Entry  Fri Apr 22 03:31:56 2011, Zach, Laser, GYRO, more LF noise hunting diff_ol_pd_noise_contrib.png
Entry  Fri Apr 22 20:17:42 2011, Aidan, Misc, ANTS!, They're heeeerrrree 
    Reply  Mon Apr 25 03:28:28 2011, Not Aidan, Misc, ANTS!, They're heeeerrrree 
Entry  Tue Apr 26 01:28:09 2011, Zach, Laser, GYRO, Aha! (?) dc_trans_vs_gyro_noise.png
    Reply  Tue Apr 26 10:34:29 2011, Alastair, Laser, GYRO, Aha! (?) 
       Reply  Tue Apr 26 15:25:24 2011, Zach, Laser, GYRO, Aha! (?) 
    Reply  Tue Apr 26 17:24:46 2011, Zach, Laser, GYRO, not mode rotation from pointing 
Entry  Tue Apr 26 18:05:08 2011, Zach, Laser, GYRO, more interesting information dctrans_vs_gyro_noise_4_26_11.pdf
Entry  Tue Apr 26 23:16:29 2011, Zach, Laser, GYRO, not laser intensity noise ISS.pnggyro_noise_with_iss_4_26_11.pdf
Entry  Wed Apr 27 18:36:34 2011, Alastair & Koji, Laser, GYRO, Misalignment tests align_to_cavity.pdffoil_over_air_gap.pdfmisalign_ccw_pd.pdf
Entry  Thu Apr 28 15:00:14 2011, Alastair, Laser, GYRO, Moving Faraday... move_faraday.pdf
Entry  Thu Apr 28 17:55:39 2011, Alastair, Laser, GYRO, Moving Faraday part 2 
Entry  Fri Apr 29 15:43:53 2011, Zach, Laser, GYRO, mode matching needs a touch-up 
Entry  Thu May 5 02:18:56 2011, Zach, Laser, GYRO, new layout new_aom_setup.pngnew_refl_setup.png
Entry  Thu May 5 16:47:54 2011, Zach, Laser, GYRO, beam profiles beam_profile_5_5_11.png
Entry  Fri May 6 12:38:49 2011, Zach, Laser, GYRO, re-modematched and realigned, locked REFL_is_small.png
Entry  Fri May 6 17:37:25 2011, Zach, Laser, GYRO, gyro not locking 
Entry  Tue May 10 11:53:48 2011, Zach, Laser, GYRO, no real progress gyro_noise_5_9_11.pdfCCW_OLTF_5_9_11.png
Entry  Tue May 10 18:46:22 2011, Zach, Laser, GYRO, Sideband trouble again TEK00011.PNGTEK00012.PNG
    Reply  Wed May 11 11:46:45 2011, Alastair, Laser, GYRO, Sideband trouble again polarization_into_EOM.epsRFAM_change.eps
Entry  Thu May 12 01:11:07 2011, Zach, Laser, GYRO, some real progress gyro_noise_wandwo_cougars_5_11_11.pdfimages.jpeg
Entry  Tue May 17 12:23:44 2011, Zach, Laser, GYRO, electronics noise OLTFs_5_16_2011.pngpdh_tfs_5_16_11.pngpdh_gnoise_5_16_11.png
Entry  Tue May 17 21:53:36 2011, Zach, Laser, GYRO, new excess noise issue resolved back_to_normal.png
Entry  Thu May 19 20:57:44 2011, Zach, Laser, GYRO, more LF noise hunting gyro_noise_with_extra_LF_gain_5_18_11.pdfccw_err_with_extra_LF_gain_5_18_11.pdfspillover_noise_5_18_11.png
Entry  Wed May 25 06:07:56 2011, Zach, Electronics, GYRO, PDH2 PCB layout PDH2.pdf
Entry  Wed May 25 19:04:41 2011, Zach, Electronics, GYRO, PDH2 PCB layout done PDH2.pdf
Entry  Thu May 26 18:40:41 2011, Zach, Electronics, GYRO, PDH2 NIM front panel PDH2_panel.pdf
Entry  Tue May 24 00:21:31 2011, Zach, Electronics, GYRO, revised PDH2 schematic PDH2.pdf
    Reply  Tue May 24 19:56:08 2011, Zach, Electronics, GYRO, revised PDH2 schematic PDH2.pdf
       Reply  Thu May 26 06:28:59 2011, Frank, Electronics, GYRO, revised PDH2 schematic 
          Reply  Thu May 26 09:17:44 2011, Zach, Electronics, GYRO, revised PDH2 schematic 
             Reply  Fri May 27 10:15:26 2011, Frank, Electronics, GYRO, revised PDH2 schematic 
                Reply  Fri May 27 10:20:47 2011, Zach, Electronics, GYRO, revised PDH2 schematic 
                   Reply  Mon May 30 15:22:22 2011, rana, Electronics, GYRO, revised PDH2 schematic 
                      Reply  Tue May 31 15:59:21 2011, Zach, Electronics, GYRO, revised PDH2 schematic PDH2.pdf
Entry  Tue May 31 19:54:14 2011, Zach, Electronics, GYRO, LAST CALL for PDH2 comments PDH2.pdf
Entry  Thu Jun 9 04:54:00 2011, Zach, Laser, GYRO, PDH2 PCB updated again PDH2.pdf
    Reply  Fri Jun 10 02:47:32 2011, Zach, Laser, GYRO, PDH2 PCB updated again PDH2.pdfPDH2_panel.pdf
Entry  Mon Jun 20 20:12:18 2011, Zach, Things to Buy, GYRO, All PDH2 stuff purchased 
Entry  Tue Jun 28 11:01:03 2011, Alastair & Zoe, Lab Infrastructure, General, Input impedance of ADC 
Entry  Tue Jun 28 11:27:30 2011, Alastair & Zoe, Electronics, GYRO, Temperature sensor buffer amplifier 00003.jpg00007.jpg
Entry  Thu Jun 30 19:20:14 2011, Zoe, Misc, GYRO, Temperature sensors tempsensor.JPGtempsensorbox.JPG
Entry  Thu Jun 30 22:04:46 2011, Zoe, Electronics, GYRO, Schematic for generic filter board GenericBoard.SchDocGenericFilter.pdfFilter_board.pdf
Entry  Fri Jul 1 13:50:17 2011, Zoe, Misc, GYRO, Temperature measurements Temperature_overnight_6-30.png
Entry  Fri Jul 1 15:37:02 2011, Zach, Electronics, GYRO, first two PDH2s built, operational 2011-07-01_14.44.56.jpg2011-07-01_14.45.19.jpg2011-07-01_14.47.59.jpg2011-07-01_14.47.45.jpg2011-07-01_14.50.54.jpg
Entry  Wed Jul 6 12:22:34 2011, Alastair & Zoe, Lab Infrastructure, General, Temperature stepped... 
Entry  Wed Jul 6 17:44:45 2011, Alastair & Zoe, Lab Infrastructure, General, Temperature step and new/changed channels on DAQ 
Entry  Wed Jul 6 20:27:19 2011, Zach, Electronics, GYRO, PDH2 S/N 7371 TF and noise spectrum TF_PDH2_7371.pnginnoise_PDH2_7371.pngoutnoise_PDH2_7371.png
Entry  Thu Jul 7 16:47:53 2011, Alastair & Zoe, Laser, GYRO, Noise in temp measurement... temp_noise.pngtemp_noise.pdf
    Reply  Fri Jul 8 12:19:46 2011, ???Mystery contributor???, Laser, GYRO, Noise in temp measurement... 
Entry  Fri Jul 8 14:19:18 2011, Alastair, Laser, GYRO, Temp sensors 
    Reply  Mon Jul 11 17:45:18 2011, Zoe, Laser, GYRO, Temp sensors July_8_temperature_data.png
       Reply  Tue Jul 12 09:14:22 2011, Alastair, Laser, GYRO, Temp sensors 
Entry  Tue Jul 12 13:41:15 2011, Alastair, Lab Infrastructure, Computing, Router replaced 
Entry  Thu Jul 14 12:08:18 2011, Alastair & Zoe, Laser, GYRO, Heated aluminum box heater1.jpgheater2.jpg
Entry  Wed Jul 13 15:02:07 2011, Zoe, Electronics, General, Generic filter board PCB genericpcb.pnggenericfilter.pngGenericBoard_v2.zip
    Reply  Fri Jul 15 03:31:21 2011, rana, Electronics, General, Generic filter board PCB 
       Reply  Fri Jul 15 09:24:28 2011, Alastair, Electronics, General, Generic filter board PCB 
          Reply  Fri Jul 15 09:26:28 2011, rana, Electronics, General, Generic filter board PCB 
             Reply  Fri Jul 15 12:25:42 2011, Zoe, Electronics, General, Generic filter board PCB 
Entry  Fri Jul 15 13:35:56 2011, Zoe, Electronics, General, Generic filter board PCB with ground plane PCB_with_ground_planes.png
Entry  Mon Jul 18 12:46:40 2011, Zach, Electronics, GYRO, PDH2 S/N 7371 current TF, noise & schematic TF_PDH2_7371_7_12_2011.pnginnoise_PDH2_7371_7_12_2011.pngPDH2.pdf
Entry  Wed Jul 20 14:46:55 2011, Zach, Electronics, GYRO, implementing PDH2 
Entry  Wed Jul 20 15:20:24 2011, Zach, Laser, GYRO, real gyro HOM plot gyro_HOM_9m_19MHz.png
Entry  Thu Jul 21 10:08:19 2011, Alastair & Zoe, Electronics, GYRO, Amplifiers for temperature sensor readout TempSensorReadoutAmplifiers.jpg
Entry  Thu Jul 21 10:34:19 2011, Alastair & Zoe, Laser, GYRO, Heater resting temperature; resistor replacement 
    Reply  Thu Jul 21 13:49:25 2011, Alastair, Laser, GYRO, Heater resting temperature; resistor replacement 
Entry  Thu Jul 21 14:35:03 2011, Alastair & Zoe, Laser, GYRO, Heater resting temperature 
Entry  Fri Jul 22 12:56:14 2011, Zach, Misc, General, Turned temp sensors off and then on 
Entry  Fri Jul 22 14:11:51 2011, Alastair & Zoe, Laser, GYRO, Temperature step 
Entry  Tue Jul 26 21:55:08 2011, Alastair, Computing, Computing, fb0 
Entry  Wed Jul 27 17:46:17 2011, Alastair & Zoe, Laser, GYRO, Shaker/Accelerometer measurement 00001.jpg00002.jpg00003.jpg00006.jpg
Entry  Wed Jul 27 18:28:40 2011, alastair, Computing, Computing, frame builder is happy again 
Entry  Thu Jul 28 13:15:09 2011, Alastair & Zoe, Laser, GYRO, temperature step 
Entry  Fri Jul 29 15:42:17 2011, Alastair, Laser, GYRO, Cavity locking 
Entry  Sat Jul 30 01:17:52 2011, Frank, Laser, PSL, 35W-laser almost ready to ship 
Entry  Mon Aug 1 15:32:01 2011, Alastair & Zoe, Laser, GYRO, Temperature sensors moved to table tempsensorsonbench.JPG
Entry  Tue Aug 2 13:55:46 2011, Alastair, Lab Infrastructure, General, Lab temperature not being controlled 
Entry  Tue Aug 2 20:41:35 2011, Frank, Laser, PSL, 35W laser ready to ship 7x
Entry  Tue Aug 2 18:12:30 2011, Zoe, Electronics, GYRO, new twin T transfer function newtwinTgain.pngoldandnewtwinT.png
    Reply  Wed Aug 3 10:22:22 2011, Zoe, Electronics, GYRO, new twin T transfer function LISO_and_measured_new_twinT.pngold_and_new_twinT.png
Entry  Wed Aug 3 15:19:15 2011, Alastair, Laser, GYRO, Reminder of calibration of AOM ACT channel 
Entry  Wed Aug 3 15:34:56 2011, Alastair, Laser, GYRO, Accelerometer channels 
Entry  Thu Aug 4 17:30:35 2011, Alastair & Zoe, Laser, GYRO, Mode measurement trans_func.pdfphase_response.pdf
Entry  Thu Aug 4 11:56:57 2011, Alastair & Zoe, Laser, GYRO, Accelerometer calibration accelerometer_calib.pdf
    Reply  Thu Aug 4 16:01:34 2011, rana, Laser, GYRO, Accelerometer calibration 
       Reply  Thu Aug 4 17:31:39 2011, Alastair, Laser, GYRO, Accelerometer calibration 
Entry  Mon Aug 8 14:55:57 2011, Zach, Laser, GYRO, EOM RAM etalon measurement RAM_scan.PNG
Entry  Mon Aug 8 17:05:30 2011, Zach, Laser, GYRO, more RAM tests TEK00003.PNGTEK00005.PNGTEK00004.PNGTEK00006.PNGTEK00007.PNG
    Reply  Tue Aug 9 01:08:51 2011, Zach, Laser, GYRO, more RAM tests 
Entry  Tue Aug 9 11:29:03 2011, Alastair & Zoe, Laser, GYRO, Huddle huddle.pdf
Entry  Tue Aug 9 11:29:04 2011, Alastair & Zoe, Laser, GYRO, Huddle huddle.pdf
    Reply  Tue Aug 9 11:59:37 2011, Zach, Laser, GYRO, Huddle 
    Reply  Tue Aug 9 15:03:54 2011, rana, Laser, GYRO, Huddle 
Entry  Tue Aug 9 16:01:50 2011, Alastair, Electronics, GYRO, ADC noise floor for temp sensing temp_sens.pdf
Entry  Mon Aug 8 17:27:27 2011, Alastair & Zoe, Laser, GYRO, Temperature sensors 
    Reply  Tue Aug 9 12:29:01 2011, Zoe, Laser, GYRO, Temperature sensors 14HoursAugust8.pngTimeSeriesAugust8.png
       Reply  Tue Aug 9 17:40:47 2011, Zoe, Laser, GYRO, Temperature sensors 
Entry  Tue Aug 9 17:46:04 2011, Zach, Laser, GYRO, RAM reduction bias servo RAM_reduct_bias_servo_8_9_11.pdf
Entry  Wed Aug 10 01:27:16 2011, Zoe, Electronics, GYRO, ADC noise and temperature data RotationNoiseAugust1.pngRotationNoiseAugust8.pngTemperatureChangesAugust8.pngTemperatureChangesAugust1.png
Entry  Wed Aug 10 08:02:50 2011, Zoe, Laser, GYRO, temperature sensor adjustment + plots from last night TimeSeriesAugust9.pngRotationNoiseAugust9.pngRotationNoiseAugust9Short.png
    Reply  Wed Aug 10 09:52:41 2011, Alastair, Laser, GYRO, temperature sensor adjustment + plots from last night 
    Reply  Wed Aug 10 10:50:08 2011, Zach, Laser, GYRO, temperature sensor adjustment + plots from last night 
       Reply  Wed Aug 10 13:43:53 2011, Zoe, Laser, GYRO, temperature sensor adjustment + plots from last night TemperatureChangesAugust9.pngRotationNoiseAugust9.png
Entry  Wed Aug 10 12:24:27 2011, Alastair & Zoe, Laser, GYRO, temperature sensors in foam box 
    Reply  Wed Aug 10 17:30:26 2011, Alastair & Zoe, Laser, GYRO, temperature sensors in foam box 
       Reply  Thu Aug 11 09:11:06 2011, Alastair & Zoe, Laser, GYRO, temperature sensors in foam box TimeSerAugust10.pngLongTimeSerAugust10.pngAmpSpecAugust10.pngTransFuncAugust10.png
Entry  Thu Aug 11 17:12:02 2011, Alastair & Rana & Zoe, Laser, GYRO, Testing temperature sensor noise SubtractionSpectrum.jpgSubtract1and2.jpgSubtract1and3.jpg3CornerHat.jpg
Entry  Thu Aug 11 16:28:41 2011, Alastair & Zoe, Laser, GYRO, Testing voltage reference noise VoltageReferenceNoise.jpg
    Reply  Fri Aug 12 11:38:54 2011, Alastair, Laser, GYRO, Testing voltage reference noise 
Entry  Fri Aug 12 12:09:26 2011, Zoe, Laser, GYRO, Temperature sensor noise compared to voltage reference noise SensorNoiseAndVoltageRefNoise.jpg
Entry  Fri Aug 12 12:13:38 2011, Alastair, Rana, Zoe, Laser, GYRO, Accelerometer calibration accel_calib.jpgcalib.mat
Entry  Fri Aug 12 15:49:48 2011, Alastair & Zoe, Laser, GYRO, better voltage regulators! testing AD587 and sensor noise 7x
Entry  Mon Aug 15 17:49:49 2011, Alastair, Laser, GYRO, Shaker measurement bench_mode.jpgcoherence.matTF_amplitude.matTF_phase.matpowerspec.mat
Entry  Tue Aug 16 15:30:37 2011, Alastair, Laser, GYRO, Mode of oscillation mode_oscillation.jpgfit.jpg
Entry  Wed Aug 10 20:27:49 2011, Zach, Laser, GYRO, bias servo implementation 
    Reply  Tue Aug 16 19:33:05 2011, Zach, Laser, GYRO, bias servo implementation 
Entry  Tue Aug 16 19:52:35 2011, Zach, Electronics, GYRO, PDH2 RF path TFs PDH2_7371_LO_TF.pngPDH2_7371_RF_TF.png
Entry  Wed Aug 17 20:16:02 2011, Alastair, Computing, Computing, gw0 
Entry  Wed Aug 17 20:04:59 2011, Zach, Electronics, GYRO, PDH2 installation 
    Reply  Wed Aug 17 20:33:05 2011, Alastair, Electronics, GYRO, PDH2 installation 
       Reply  Thu Aug 18 03:09:37 2011, Zach, Electronics, GYRO, PDH2 installation 
Entry  Tue Aug 23 00:56:07 2011, Zach, Electronics, GYRO, LC homodyne discriminator LC_homodyne_diagram.png
    Reply  Wed Aug 24 05:26:03 2011, rana, Electronics, GYRO, LC homodyne discriminator 
       Reply  Wed Aug 24 10:47:58 2011, Zach, Electronics, GYRO, LC homodyne discriminator 
Entry  Wed Aug 31 10:19:25 2011, Alastair, Laser, GYRO, Inside an EOM photo_2.JPGphoto_4.JPGphoto_3.JPG
Entry  Fri Jul 29 23:38:42 2011, rana, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
    Reply  Mon Aug 1 15:59:58 2011, Zach, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise nb_3_2011.png
       Reply  Mon Aug 1 18:13:40 2011, Zoe, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise Amplitude_spectra_Aug1.pngTime_series_Aug1.png
          Reply  Tue Aug 2 10:15:57 2011, Zach, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise temp_noise_spectrum_vs_H1PSL.png
             Reply  Tue Aug 2 12:09:57 2011, Zoe, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise Temperature_fluctuations_overnight_Aug1.pngRotation_noise_overnight_Aug1.png
                Reply  Tue Aug 2 12:22:30 2011, Alastair, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
                   Reply  Tue Aug 2 12:32:35 2011, Zoe, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
                      Reply  Tue Aug 2 12:47:02 2011, Alastair, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
                         Reply  Tue Aug 2 18:28:04 2011, Zoe, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise Rotation_noise_overnight_August_1.pngRotation_noise_with_ADC_noise.pngTime_series_August_2.png
                            Reply  Wed Aug 3 10:34:06 2011, Alastair, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
    Reply  Tue Sep 6 10:56:22 2011, rana, Misc, GYRO, Thermal Expansion Noise -> Gyro Noise 
Entry  Tue Sep 6 20:55:47 2011, Zach, Laser, GYRO, PD noise open_loop_test_9_6_11.png
    Reply  Wed Sep 7 16:25:05 2011, Zach, Laser, GYRO, PD noise 
Entry  Thu Sep 8 11:57:23 2011, Zach, Laser, GYRO, some LF noise progress 
Entry  Fri Sep 9 19:14:07 2011, Zach, Laser, General, LF_WTF? gyro_noise_vs_dc_trans_9_9_11.pdf
Entry  Wed Sep 14 14:54:24 2011, Zach, Laser, GYRO, frequency-dependent, low-frequency AM found 
    Reply  Thu Sep 15 08:16:25 2011, Alastair, Laser, GYRO, frequency-dependent, low-frequency AM found 
       Reply  Thu Sep 15 10:35:46 2011, Zach, Laser, GYRO, frequency-dependent, low-frequency AM found 
Entry  Fri Sep 16 01:38:25 2011, Zach, Laser, GYRO, 3f demod and other tests config_tests_9_15_11.pdf3f_demod_9_15_11.pdf
Entry  Fri Sep 16 18:58:10 2011, Zach, Laser, GYRO, SS PMC 
Entry  Mon Sep 19 22:08:54 2011, Zach, Laser, GYRO, proposed layout, PMC MMT, etc. new_layout_PMC.pngPMC_MMT.png
Entry  Tue Sep 20 23:13:21 2011, Zach, Laser, GYRO, SS PMC 6x
Entry  Tue Oct 4 18:27:57 2011, Zach, Laser, Fugly, why should a laser do this? TEK00006.PNG
Entry  Tue Oct 4 19:24:21 2011, Zach, Laser, GYRO, PMC locked (a while ago) PMC_lock1.pngPMC_lock2.png
Entry  Thu Oct 6 19:42:23 2011, Zach, Laser, GYRO, simple setup for testing simple_setup.png
Entry  Tue Sep 14 04:14:25 2010, Dmass, Misc, Doubling, Doubling results summary 
    Reply  Wed Sep 15 17:04:36 2010, Dmass, Misc, Doubling, DON'T REMOVE OPTICS YET 
       Reply  Wed Sep 15 22:59:37 2010, Frank, Misc, Doubling, DON'T REMOVE OPTICS YET 
    Reply  Tue Sep 21 01:52:05 2010, Dmass, Misc, Doubling, Doubling results summary AllanVarSep2.pdf
       Reply  Thu Oct 6 23:44:09 2011, Dmass, Misc, Doubling, Finishing SHG paper AvarWhitePhase.pdfAvarWhiteFreqNoise.pdfAvarPhase1onfhalf.pdf
          Reply  Mon Oct 10 11:55:59 2011, Dmass, Misc, Doubling, Finishing SHG paper Avar2PhaseSchnatz.pdf
    Reply  Wed Sep 22 17:16:09 2010, Dmass, Misc, Doubling, Some notes on previous bounds 
       Reply  Mon Jan 24 17:17:59 2011, Dmass, Misc, Doubling, Some notes on previous bounds 
Entry  Thu Oct 13 02:08:22 2011, Zach, Laser, GYRO, initial scattered light tests scat_light_driving_test.pdfscat_light_opening_test.pdfscat_light_opening_test_log.pdf
Entry  Fri Oct 14 00:56:54 2011, Zach, Laser, GYRO, more testing misalignment_test_10_13_11.pdfmisalignment_test_10_13_11.pdf
    Reply  Sat Oct 15 11:03:18 2011, rana, Laser, GYRO, more testing 
Entry  Mon Oct 17 23:32:04 2011, Zach, Laser, GYRO, PMC (again!) pmc1.pngpmc2.png
Entry  Tue Oct 18 16:38:27 2011, Zach, Misc, stuff happens, ATF floppy drive is missing 
Entry  Wed Oct 19 20:38:13 2011, Zach, Laser, GYRO, gyro cavity locked with PMC pmc_servo.pngpmc_gyro_traced.pnggyro_locked.png
Entry  Tue Oct 18 23:42:47 2011, Koji, Laser, GYRO, PMC Finesse measurement 
    Reply  Thu Oct 20 17:02:34 2011, Koji, Laser, GYRO, Power Budget of the PMC PMC.pdfPA201622.jpg
Entry  Tue Oct 25 00:48:13 2011, rana, Misc, GYRO, Chandler 
Entry  Thu Oct 20 00:47:21 2011, Zach, Laser, GYRO, LF noise still there TRANS_with_PMC_10_19_11.pdf
    Reply  Tue Nov 1 22:45:26 2011, Koji, Laser, GYRO, Wierd (LF noise still there) 
Entry  Thu Nov 3 12:28:28 2011, Zach, Laser, Iodine, Cells have arrived 6x
Entry  Thu Nov 3 19:45:26 2011, Zach, Laser, GYRO, gyro cavity mirrors drag wiped NE.pngNW.pngSE.pngSW.pngmirrors_clean.png
Entry  Mon Nov 7 14:43:05 2011, Eric, Laser, Iodine, Beam profile for Iodine stabilized laser beam_profile.png
Entry  Tue Nov 8 00:20:47 2011, Zach, Laser, GYRO, vacuum chamber prepped 
Entry  Wed Nov 9 00:39:52 2011, Zach, Laser, fubar, What not to do to a dogclamp busted_dc1.pngbusted_dc2.png
Entry  Wed Nov 9 00:59:00 2011, Zach, Laser, GYRO, Gyro cavity reassembled, intensity noise remeasured intensity_noise_vs_position.png
Entry  Thu Nov 10 23:55:28 2011, Zach, Electronics, Iodine, Precision temperature controller temp_control_diagram.pngtemp_ctrl.pdf
    Reply  Mon Nov 14 22:31:46 2011, Den, Electronics, Iodine, Precision temperature controller 
Entry  Wed Nov 16 02:30:44 2011, Zach, Laser, GYRO, Vacuum window removal test no_windows.pngintensity_noise_vs_position_11_15_11.png
Entry  Fri Nov 18 01:31:44 2011, Zach, Laser, GYRO, more air noise testing intensity_noise_vs_position_with_coherence_11_17_11_all.pngPB170439.jpg
    Reply  Fri Nov 18 03:57:44 2011, Koji, Laser, GYRO, more air noise testing 
Entry  Tue Nov 22 15:12:34 2011, Zach, Laser, GYRO, Laser swapped--noise worse trans_noise_new_old_laser_11_21_11.png
Entry  Mon Nov 28 19:12:05 2011, Eric, Laser, Iodine, Iodine frequency stabilization layout Hybrid_FMS_Schematic_DBM.png
Entry  Wed Dec 7 16:10:29 2011, Eric, Laser, Iodine, Layout Update/Inventory Hybrid_FMS_Schematic_DBM_Collinear.png
Entry  Wed Dec 7 16:48:13 2011, Eric, Laser, Iodine, Pressure/Temp Calibration for Iodine Cell pt_curve.png
Entry  Thu Dec 8 15:50:45 2011, Zach, Laser, GYRO, Gyro NPRO restored 
Entry  Fri Dec 9 17:30:49 2011, Zach, Laser, GYRO, new box basic drawing new_box_drawing.png
    Reply  Fri Dec 9 17:56:07 2011, Koji, Laser, GYRO, new box basic drawing 
Entry  Wed Dec 14 16:31:03 2011, Zach, Laser, GYRO, new box feedthrough solution new_box_side_detail.png
Entry  Fri Dec 16 19:09:34 2011, Zach, Laser, GYRO, PMC locked with CDS+HV 
Entry  Mon Dec 19 21:23:45 2011, Zach, Laser, GYRO, PMC stuff (including OLTF) surgery.pngwires.pnggyro_PMC_OLTF_12_19_11.png
Entry  Tue Dec 20 14:52:05 2011, Zach, Computing, Computing, Added 'sitemap' alias to fb0 
Entry  Tue Jan 3 15:59:07 2012, Aidan, Computing, Computing, Directory clean up 
Entry  Wed Jan 4 02:33:00 2012, Eric, Laser, Iodine, CORRECTED Beam Profile for 700mW NPRO corrected_beam_profile.pngknife_edge_beam_width_analysis.pdf
Entry  Thu Jan 12 16:27:48 2012, Zach, Laser, Fugly, Digital PMC loop too slow? 
    Reply  Fri Jan 13 01:21:45 2012, Zach, Laser, Fugly, Digital PMC loop too slow? intensity_noise_vs_loc_1_12_12.pnggyro_PMC_OLTF_1_12_12.png
Entry  Sat Jan 14 17:58:25 2012, Zach, Laser, RAM, RAM measurement setup RAM_setup_labelled.pngTEK00000.PNGRAM_data_1_13_12.png
    Reply  Wed Jan 18 01:13:45 2012, Zach, Laser, RAM, RAM measurement setup Screen_shot_2012-01-18_at_12.32.43_AM.png
Entry  Wed Jan 18 01:16:56 2012, Zach, Laser, Iodine, 700-mW SOP written 
Entry  Thu Jan 19 01:46:24 2012, Zach, Laser, RAM, Update on RAM measurements 24hrs_no_foam.pngshift_by_45deg.png
Entry  Thu Jan 19 02:34:39 2012, Zach, Laser, GYRO, PMC locked with PDH Box #2215 +HV PMC_servo_setup.pngpdh2215_1_18_12_(PMC).png
Entry  Fri Jan 20 01:02:20 2012, Zach, Laser, GYRO, PMC OLTF PMC_OLTF_1_19_12.png
Entry  Fri Jan 20 01:33:30 2012, Zach, Laser, RAM, foam/no foam 6-hr comparison foam_no-foam_comparison.png
Entry  Fri Jan 20 12:59:54 2012, Zach, Laser, GYRO, MIRRORS ARE IN (AND APPARENTLY CORRECT) - AT LAST! mirrors_in_packaging.pngATF_200ppm_specs.pdf
Entry  Fri Jan 20 19:32:12 2012, Zach, Laser, GYRO, notch filter added to PMC loop gyro_pmc_notch_TF.pngPMC_OLTF_1_20_12.png
Entry  Tue Jan 24 00:56:07 2012, Zach, Laser, RAM, no foam/foam, no heat/foam+heat comparison no_foam.pngfoam_no_heat.pngfoam_heat.pngRAM_Temp_comparison_1_23_12.png
Entry  Thu Jan 26 16:47:15 2012, Eric, Laser, Iodine, Mode matching NPRO into doubling crystal photo_1.JPGphoto_8.jpg
Entry  Thu Jan 26 11:14:35 2012, Zach, Laser, Iodine, assembly has begun 
    Reply  Thu Jan 26 17:21:50 2012, Eric, Laser, Iodine, assembly has begun photo_2.JPG
Entry  Thu Jan 26 20:19:53 2012, Zach, Electronics, GYRO, generic filter board put in NIM module filter_board1.pngfilter_board2.png
Entry  Mon Jan 30 23:50:12 2012, Eric, Laser, Iodine, Frequency doubled! photo_14.JPGphoto_18.JPGphoto_22.JPG
Entry  Sat Jan 28 12:33:59 2012, Zach, Laser, GYRO, New vacuum system viewport design viewports.png
    Reply  Tue Jan 31 16:01:26 2012, Zach, Laser, GYRO, New vacuum system viewport design 
    Reply  Thu Feb 2 07:49:23 2012, steve, Laser, GYRO, New vacuum system viewport design 
Entry  Fri Feb 3 03:10:25 2012, Eric, Laser, Iodine, Greatly enhanced SHG  SHG_Setup_1.JPGSHG_Setup_18.JPG
    Reply  Fri Feb 3 10:05:47 2012, Zach, Laser, Iodine, Greatly enhanced SHG  green_pwr1.pnggreen_pwr2.png
       Reply  Mon Feb 6 06:29:07 2012, Eric, Laser, Iodine, Greatly enhanced SHG F2_Transmission.jpgF2_Reflectance_Enlarged.jpg
          Reply  Mon Feb 6 10:48:21 2012, Zach, Laser, Iodine, Greatly enhanced SHG 
Entry  Fri Feb 3 22:51:47 2012, Zach, Laser, Iodine, resonant visible EOM characterization viseomz_2_3_12.pngeom_open.png
    Reply  Mon Feb 6 13:33:32 2012, Zach, Laser, Iodine, resonant visible EOM characterization viseomz_2_6_12.png
Entry  Tue Feb 7 09:22:18 2012, Eric, Laser, Iodine, Gaussian Beam Mode Profile in PPKTP Crystal PPKTP_mode_profile_bare.pngPPKTP_mode_profile_full.pngPPKTP_mode_profile_full.png
Entry  Tue Feb 7 21:14:49 2012, Zach, Laser, Iodine, Doubling efficiency not really that good Screen_shot_2012-02-07_at_7.25.28_PM.png
Entry  Tue Feb 7 16:53:01 2012, Zach, Laser, RAM, DC bias testing temp_ctrl_off.pngtemp_ctrl_on.pngDC_bias_on_then_off.png
    Reply  Tue Feb 7 22:15:18 2012, Zach, Laser, RAM, DC bias testing DC_bias_on_off_LF_spect.png
Entry  Thu Feb 9 01:02:47 2012, Eric, Misc, Iodine, Iodine localized in cold fingers Photo_Feb_08_4_48_10_PM.jpg
Entry  Fri Feb 10 01:31:24 2012, Zach, Laser, Iodine, Green/IR isolating mirror 532nm transmission 
Entry  Wed Feb 15 14:52:10 2012, Zach, Laser, RAM, heater servo OLTF heater_servo_oltf_2_14_12.png
    Reply  Thu Feb 16 03:33:59 2012, Zach, Laser, RAM, Improved DC gain (integrator) BAC.pngimpulse_response.pngcontroller_circuit_2_15_12.png
       Reply  Thu Feb 16 20:26:17 2012, Zach, Laser, RAM, new OLTF and modified experimental setup heater_servo_oltf_2_16_12.pngexperimental_setup.png
Entry  Wed Feb 22 01:46:43 2012, Zach, Laser, GYRO, viewports finished vp1.pngvp4.pngvp3.pngvp2.png
Entry  Wed Feb 22 02:33:41 2012, Zach, Laser, RAM, Recent stabilization trial results time_series.pngEOM_temp_stab_2_21_12.png
Entry  Fri Feb 24 03:02:01 2012, Zach, Laser, GYRO, Viewport installation finished, chamber pumped down 
Entry  Sun Feb 26 02:23:27 2012, Zach, Laser, GYRO, vacuum bettered, PDH2 commissioning begins vac_level.pngtest_cavity.png
Entry  Mon Feb 27 17:19:12 2012, Zach, Laser, GYRO, vacuum longevity 
Entry  Tue Feb 28 02:56:39 2012, Zach, Laser, GYRO, stuff that happened today tem_cav_box.pngTRANSs.png
Entry  Tue Feb 28 22:17:09 2012, Zach, Laser, Iodine, optics ordered 
Entry  Wed Feb 29 02:15:55 2012, Zach, Electronics, GYRO, PDH2 TF design 
    Reply  Wed Feb 29 18:00:54 2012, Zach, Electronics, GYRO, PDH2 TF design, electronics noise estimates PDH2_TF_noboost.pngPDH2_TF_boost.pngestimated_primary_OLTF.pngaGyro_electronics_noise.png
Entry  Fri Mar 2 16:40:07 2012, Zach, Electronics, GYRO, PDH2 S/N 7371 current TF and noise pdh2_7371_tf_3_2_12.pngpdh2_7371_inputnoise_3_2_12.png
Entry  Sat Mar 3 02:37:23 2012, Zach, Laser, GYRO, new optics cleaned, installed, roughly aligned mirrors_on_bench.pngcavity_aligned.png
Entry  Wed Mar 7 02:53:06 2012, Zach, Electronics, GYRO, servo purgatory 
Entry  Wed Feb 29 01:43:57 2012, Zach, Laser, GYRO, chamber leak hunting  
    Reply  Wed Feb 29 15:14:51 2012, Zach, Laser, GYRO, chamber leak hunting  chamber_labels.png
    Reply  Wed Mar 7 08:50:04 2012, steve, Laser, GYRO, chamber leak hunting advice 
Entry  Thu Feb 23 01:38:21 2012, Zach, Laser, GYRO, input-side viewports installed vp_installed1.pngvp_installed2.pngvp_installed3.png
    Reply  Wed Mar 7 09:05:22 2012, steve, Laser, GYRO, input-side viewports installed & design flaw 
Entry  Wed Mar 7 18:30:16 2012, Zach, Laser, Iodine, green optics in green_parts.png
Entry  Fri Mar 9 03:27:58 2012, Zach, Laser, GYRO, Cavity locked with PDH2 
Entry  Sat Mar 10 10:35:10 2012, Zach, Laser, GYRO, darkness warshed over the gyro... table_clear.png
Entry  Sat Mar 10 22:51:01 2012, Zach, Laser, GYRO, NPRO reprofiled gyro_npro_beam_profile_3_10_12.png
Entry  Sat Mar 10 23:26:13 2012, Zach, Laser, GYRO, PMC setup reassembled, locked PMC_layout.pngPMC_locked.png
Entry  Sun Mar 11 15:26:41 2012, Zach, Laser, GYRO, PMC MMT X_ABCD.pngY_ABCD.png
Entry  Sun Mar 11 15:40:54 2012, Zach, Misc, Optics, ATF lens inventory 
Entry  Mon Mar 12 21:31:29 2012, Zach, Laser, GYRO, REFL RFPDs retuned REFL_RFPD_tuning_3_12_12.png
Entry  Mon Mar 12 21:46:50 2012, Zach, Laser, GYRO, Predicted cavity/HOM spectra cavity_spectrum_3_12_12.pngHOM_3_12_12.png
Entry  Mon Mar 12 22:51:59 2012, Zach, Laser, GYRO, PMC MMT redone, PMC relocked PMC_spectrum.png
Entry  Tue Mar 13 03:56:30 2012, Zach, Laser, GYRO, Reconstruction update AOM_mode_matching.pngAOM_setup.pngprofile_post_PMC-EOM_3_12_12.png
Entry  Wed Mar 14 02:21:17 2012, Zach, Laser, GYRO, AOM double-pass set up, etc. CW_profile_3_13_12.pngAOM_redone_over_and_over_and_over.png
Entry  Wed Mar 14 16:52:41 2012, Zach, Laser, GYRO, I/O pretty much complete IO.png
Entry  Fri Mar 16 06:41:59 2012, Zach, Laser, GYRO, Moderate progress CCW_lock1.pngCCW_lock2.pngCCW_lock3.png
Entry  Sat Mar 17 02:54:31 2012, Zach, Laser, GYRO, Throwing in the towel 
Entry  Tue Apr 10 00:41:20 2012, Zach, Laser, GYRO, CCW beam profile remeasured CCW_profile_4_9_12.png
Entry  Tue Apr 10 21:35:03 2012, Zach, Laser, Iodine, Cell holder solution cell_mount.png
Entry  Thu Apr 12 14:43:38 2012, Zach, Laser, GYRO, Terrible cavity coupling 
    Reply  Fri Apr 13 02:39:43 2012, Zach, Laser, GYRO, Terrible cavity coupling 
Entry  Mon Apr 16 12:42:57 2012, Zach, Laser, Iodine, Some 1064nm optics ordered 
Entry  Sun Apr 15 19:28:14 2012, Zach, Laser, GYRO, Loss investigation REFL_setup.pngTEK00010.PNG300ppm.png
    Reply  Tue Apr 17 14:42:46 2012, Zach, Laser, GYRO, Loss investigation sweep_vac_4_16_12.PNGsweep_air_4_16_12.PNG
       Reply  Tue Apr 17 20:08:00 2012, Zach, Laser, GYRO, Loss investigation unlocked.pnglocked.png
          Reply  Wed Apr 18 23:31:26 2012, Frank, Laser, GYRO, Loss investigation 
             Reply  Thu Apr 19 01:36:22 2012, Zach, Laser, GYRO, Loss investigation 
Entry  Fri Apr 20 22:08:10 2012, Zach, Laser, Iodine, PBSs received PBS.png
Entry  Mon Apr 23 15:00:44 2012, Zach, Laser, Iodine, mounts ordered 
Entry  Tue Apr 24 02:31:24 2012, Zach, Laser, Iodine, cell holder almost finished hole_tapped.pngthermistor_hole.pngassembly.png
Entry  Mon Apr 30 16:05:52 2012, Zach, Laser, GYRO, Installing G&H mirror geom.pngspect.pngHOM.pngHOM_zoom.png
    Reply  Tue May 1 02:23:15 2012, Zach, Laser, GYRO, Installing G&H mirror sweep.PNG
       Reply  Wed May 2 10:20:04 2012, Alastair, Laser, GYRO, Installing G&H mirror 
Entry  Wed May 2 13:43:30 2012, Zach, Laser, GYRO, aLIGO PMC mirrors 1mirror.png2mirrors.png
Entry  Wed May 23 10:31:38 2012, Zach, Laser, Iodine, rest of 1064nm parts received 
Entry  Wed May 23 10:53:49 2012, Zach, Laser, GYRO, aLIGO PMC mirrors obtained aLIGO_PMC_mirrors.png
Entry  Wed May 23 11:34:21 2012, Zach, Laser, GYRO, aLIGO PMC mirror T(45) 
Entry  Wed May 23 11:50:51 2012, Zach, Laser, GYRO, New gyro estimates newgeom.pngnewspect.pngnewHOM.png
Entry  Wed May 23 12:07:46 2012, Zach, Laser, GYRO, New CCW MMT (with one aLIGO PMC mirror) 
Entry  Fri May 25 10:49:25 2012, Zach, Laser, GYRO, MMT installed, new mirror cleaned and installed MMT.pngmirror_clean.png
Entry  Fri May 25 14:51:39 2012, Zach, Laser, GYRO, cavity aligned and locked with new mirror, looks promising 
Entry  Fri May 25 20:44:59 2012, Zach, Laser, GYRO, no real improvement at vacuum TEK00000.PNGTEK00001.PNGTEK00003.PNG75ppm.png
    Reply  Sat May 26 15:27:18 2012, Koji, Laser, GYRO, no real improvement at vacuum 
       Reply  Mon May 28 13:40:04 2012, Zach, Laser, GYRO, no real improvement at vacuum 
Entry  Wed May 30 02:03:06 2012, Zach, Laser, GYRO, gyro AM TF amtf.png
Entry  Wed May 30 14:03:51 2012, Zach, Laser, GYRO, better AM TF amtf_5_30_12.png
    Reply  Wed May 30 19:11:35 2012, rana, Laser, GYRO, better AM TF 
       Reply  Mon Jun 4 21:33:09 2012, Zach, Laser, GYRO, better AM TF 
          Reply  Tue Jun 5 23:23:36 2012, rana, Laser, GYRO, better AM TF 
Entry  Wed Jun 6 04:28:37 2012, Zach, Electronics, Iodine, temperature controller circuit (v2) temp_ctrl_v2.pdf
Entry  Sat Jun 9 13:43:52 2012, Zach, Laser, GYRO, Loop verification pdh2_7371_tf_6_8_12.pngpdh2_7371_tf_vs_coh_6_8_12.pngoltf_6_8_12.png
Entry  Tue Jun 12 00:37:00 2012, Zach, Laser, GYRO, better servo TF PDH2_7371_TF_6_11_12.png
Entry  Tue Jun 12 00:44:32 2012, Zach, Laser, GYRO, AOM double-pass reoptimized, CW beam profiled CW_profile_6_11_12.png
Entry  Tue Jun 12 14:19:59 2012, Zach, Laser, GYRO, CW MMT 
Entry  Thu Jun 14 10:51:56 2012, Zach, Laser, GYRO, CW MMT installed, input beams realigned MMTs.png
Entry  Fri Jun 15 00:51:09 2012, Zach, Laser, GYRO, Bidirectional resonance both_locked_ish.png
Entry  Fri Jun 15 04:20:36 2012, Zach, Electronics, Iodine, temperature controller PCB layout temp_ctrl_v2.pngScreen_Shot_2012-06-15_at_4.15.32_AM.png
Entry  Sat Jun 16 12:20:21 2012, Zach, Laser, GYRO, (Dubious) linewidth measurement TEK00004.PNG
    Reply  Sat Jun 16 18:56:36 2012, Koji, Laser, GYRO, (Dubious) linewidth measurement 
       Reply  Mon Jun 18 22:49:47 2012, Zach, Laser, GYRO, (Dubious) linewidth measurement 
    Reply  Mon Jun 18 18:01:52 2012, Rana, Laser, GYRO, (Dubious) linewidth measurement 
Entry  Tue Jun 19 01:49:53 2012, Zach, Laser, GYRO, CW locked, very preliminary noise spectrum both_REFL.jpgAOM_ACT_DC_TRANS_and_COH_6_18_12.png
Entry  Tue Jun 19 23:58:57 2012, Zach, Laser, GYRO, intensity noise / gyro noise testing noise_and_RIN_wandwo_box_6_19_12.png
Entry  Sat Jun 23 17:52:55 2012, Zach, Electronics, Iodine, Temp controller NIM front panel temp_ctrl_panel.png
Entry  Sun Jun 24 14:48:49 2012, Zach, Laser, GYRO, RAM monitor / optimization RAMmon.png
Entry  Fri Jun 22 20:16:16 2012, Zach, Electronics, Iodine, Temp controller PCB almost done temp_ctrl_v2.png
    Reply  Wed Jun 27 10:34:06 2012, rana, Electronics, Iodine, Temp controller PCB almost done 
       Reply  Wed Jun 27 13:42:53 2012, Zach, Electronics, Iodine, Temp controller PCB almost done temp_ctrl_panel.png
Entry  Wed Jun 27 15:53:44 2012, Zach, Electronics, Iodine, Temp controller design re-revised 100k_thermistor_response.pngtemp_ctrl_v2.png
    Reply  Sun Jul 1 01:33:57 2012, rana, Electronics, Iodine, Temp controller design re-revised 
       Reply  Sun Jul 1 07:41:38 2012, Zach, Electronics, Iodine, Temp controller design re-revised 
Entry  Mon Jul 2 18:16:09 2012, Zach, Electronics, Iodine, Temp controller "final" revision temp_ctrl_v2.png
Entry  Mon Jul 2 18:34:09 2012, Zach, Computing, DAQ, machines restarted 
Entry  Thu Jul 5 14:42:25 2012, Zach, Electronics, Iodine, Temperature controller boards ordered temp_ctrl_v2.png
Entry  Fri Jul 6 13:40:43 2012, Zach, Electronics, Iodine, Temp controller front panels ordered temp_ctrl_panel.png
Entry  Wed Jul 11 13:48:03 2012, Zach, Electronics, Iodine, temp controller parts 
Entry  Fri Jul 13 15:58:25 2012, Zach, Electronics, Iodine, board update 
Entry  Wed Jul 18 16:47:16 2012, Zach, Electronics, Iodine, temp controller parts in! board.pngpanel.pngchips.pnglineup.png
Entry  Thu Jul 19 14:43:17 2012, Zach, Laser, GYRO, digital noise -> gyro noise Untitled.pngloop.pngeq1.pngeq2.png
Entry  Fri Jul 20 01:25:34 2012, Zach, Electronics, Iodine, Starting board stuffing board_stuffing.png
Entry  Sat Jul 21 17:44:00 2012, Zach, Electronics, Iodine, Board testing board_mostly_stuffed.pngpanel_fits_board.png
    Reply  Tue Jul 24 04:24:53 2012, Zach, Electronics, Iodine, Board testing board_done.pngAl_plate.pngstabilized.pngcell_holder.png
Entry  Wed Jul 25 17:58:44 2012, Zach, Laser, GYRO, Gyro not locking 
Entry  Thu Jul 26 16:18:02 2012, Zach, Laser, GYRO, Gyro still sucking 
Entry  Mon Aug 6 20:00:44 2012, Zach, Laser, GYRO, Still no lock 
Entry  Mon Aug 6 20:18:28 2012, Zach, Laser, Iodine, doubling again green.png
Entry  Mon Aug 6 20:31:27 2012, Zach, Electronics, Iodine, NIM crate moved from EE shop to iodine bench NIM.png
Entry  Thu Aug 9 12:57:47 2012, Zach, Laser, Iodine, VIS turning mirrors ordered 
Entry  Thu Aug 9 13:45:03 2012, Zach, Laser, GYRO, Gyro locked with uPDH box; diagnosing PDH2 issue 7x
Entry  Thu Aug 9 16:41:34 2012, Zach, Laser, GYRO, Primary loop noise prim_loop_ctrl_noise_8_8_12.png
Entry  Thu Aug 9 23:45:54 2012, Zach, Laser, GYRO, AOM actuation transfer function, etc. TEK00000.PNGTEK00003.PNGAOM_ACT_TF_8_9_12.pngdouble_lock.pngCW_OLTF_PDH2_8_9_12.png
Entry  Fri Aug 10 01:19:47 2012, Zach, Laser, GYRO, noise spectrum with servos switched gyro_noise_servos_switched_8_9_12.png
    Reply  Fri Aug 10 15:57:03 2012, rana, Laser, GYRO, noise spectrum with servos switched 
Entry  Sat Aug 11 02:45:54 2012, Zach, Electronics, GYRO, added zero to CW OLTF, increased UGF to 30 kHz differentiator.pngdifferentiator_tf.pngfilter_board.pngCW_OLTF_8_10_12.png
Entry  Sat Aug 11 03:00:02 2012, Zach, Laser, GYRO, CW_TRANS intensity noise testing CW_TRANS_intensity_noise_8_10_12.png
    Reply  Sat Aug 11 11:51:51 2012, rana, Laser, GYRO, CW_TRANS intensity noise testing 
Entry  Tue Aug 14 01:41:46 2012, Zach, Laser, GYRO, CW_TRANS ISS test CW_TRANS_ISS_test_8_13_12.png
Entry  Tue Aug 14 02:17:33 2012, Zach, Laser, GYRO, open-loop CW_ERR tests (for LF noise) CW_ERR_tests_8_13_12.pngTEK00004.PNG
Entry  Fri Aug 17 00:47:52 2012, Zach, Electronics, GYRO, Daedalus NIMified, used to stabilize New Focus EOM front.pngside.pngin_action.pngstabilized.png
Entry  Fri Aug 17 01:24:25 2012, Zach, Laser, GYRO, RAM subtraction OOL_sensor.pngRAM_REFL_vs_OOL_8_16_12.pngTso.pngsubtraction.png
Entry  Fri Aug 17 19:59:28 2012, tara, Electronics, TempCtrl, temp control for EOM 
Entry  Mon Aug 20 04:10:25 2012, Zach, Electronics, GYRO, Ultra-low-noise preamp built (almost) zamp.pngHPF.png
Entry  Mon Aug 20 04:25:41 2012, Zach, Laser, GYRO, RAM witnesses for both directions RAM_witnesses.png
Entry  Mon Aug 20 04:36:28 2012, Zach, Laser, GYRO, TRANS and PLL set up TRANS.pnggyro_noise_8_19_12.png
Entry  Tue Aug 21 04:13:06 2012, Zach, Electronics, GYRO, PDH2 transfer functions are really stupid uPDH_1437_and_PDH2_7371_vs_boost_8_20_12.png
Entry  Tue Aug 21 04:54:26 2012, Zach, Electronics, GYRO, Attempted "very fast" path phase_modulator.pngEOM_drive.png
Entry  Tue Aug 21 23:29:38 2012, tara, Misc, TempCtrl, thermal insulation for cold finger and EOM IMG_1607.JPGIMG_1608.jpgIMG_1609.JPG
Entry  Wed Aug 22 01:17:07 2012, Zach, Electronics, GYRO, PDH2 modified; still can't lock primary PDH2_noboost_TF_comparison_8_21_12.pngPDH2_fullboost_TF_comparison_8_21_12.pngPDH_LF_noise_comparison_8_21_12.pngpdh2_vs_LISO_8_21_12.png
Entry  Fri Aug 24 01:32:21 2012, Zach, Laser, GYRO, EOM stabilized with Daedalus AC_fix.pngEOM_in_box.pngimpulse_response.PNG
Entry  Fri Aug 24 01:55:12 2012, Zach, Laser, GYRO, PDH2 locking attempts PDH2_vs_uPDH_8_23_12.pngcrappy_oltf_8_23_12.pngpdh2_vs_liso_8_23_12.png
    Reply  Fri Aug 24 02:29:23 2012, Zach, Laser, GYRO, PDH2 locking attempts notch.pngOLTF_vs_model_8_23_12.png
       Reply  Fri Aug 24 15:47:22 2012, rana, Laser, GYRO, PDH2 locking attempts 
          Reply  Sat Aug 25 00:11:02 2012, Zach, Laser, GYRO, PDH2 locking attempts 
Entry  Tue Aug 28 05:43:35 2012, Zach, Electronics, GYRO, PDH2 7371 fixed LISO_stage-by-stage_8_27_12.pngu3vliso.pngu6vliso.pngPDH2_7371_mods_8_27_12.png
Entry  Tue Aug 28 06:03:35 2012, Zach, Laser, GYRO, Primary locked with PDH2, current OLTF servo_plus_notch_before_after_8_27_12.pngCCW_OLTF_8_27_2012.pngprim_err_vs_act_noslow_8_27_12.png
Entry  Tue Aug 28 17:39:50 2012, Zach, Laser, GYRO, Primary signals and mechanical noise estimates prim_sigs_8_27_12.pngmech_noise_8_27_12.png
Entry  Wed Aug 29 18:12:00 2012, Zach, Electronics, GYRO, low-noise preamp finished; op amp wisdom 6x
Entry  Wed Aug 29 20:00:32 2012, Zach, Laser, GYRO, HELP: PMC 
Entry  Wed Aug 29 21:15:28 2012, Zach, Laser, GYRO, Hasty noise budget, realizations (most good) gyro_nb_8_29_12.png
Entry  Tue Sep 4 01:41:00 2012, Zach, Laser, GYRO, BEST gyro sensitivity ever with RAM subtraction gyro_noise_RAM_coherence_8_31_12.pngnoise_with_subtraction_8_31_12.png
Entry  Tue Sep 4 01:28:57 2012, Zach, Electronics, GYRO, Marconi phase noise vs deviation marconi_noise_8_31_12.png
    Reply  Tue Sep 4 10:31:50 2012, rana, Electronics, GYRO, Marconi phase noise vs deviation 
       Reply  Tue Sep 4 15:14:02 2012, Zach, Electronics, GYRO, Marconi phase noise vs deviation 
Entry  Wed Sep 5 13:03:01 2012, Zach, Electronics, GYRO, Better Marconi noise measurement marconi_setup.pngmarconi_noise_dual-Rb_9_4_12.png
Entry  Thu Sep 6 06:06:46 2012, Zach, Laser, GYRO, NEW BEST gyro noise, without subtraction gyro_noise_9_5_12.png
    Reply  Thu Sep 6 12:33:46 2012, Koji, Laser, GYRO, NEW BEST gyro noise, without subtraction noise_BBPD.pdf
Entry  Fri Sep 7 02:56:08 2012, Zach, Laser, GYRO, PLL noise matches AOM_ACT noise gyro_noise_9_6_12.pnggyro_noise_LF_coherence_9_6_12.png
Entry  Fri Sep 7 03:33:03 2012, Zach, Laser, GYRO, Anatomy of the current noise floor gyro_noise_vs_FSRplusRAM_9_6_12.pngOOL_CW_PD_running_vs_dark_9_6_12.png
Entry  Mon Sep 10 14:26:06 2012, Zach, Laser, GYRO, Not RAM-like noise gyro_noise_9_7_12.png
Entry  Wed Sep 12 20:56:59 2012, tara, Electronics, General, seismometers installed IMG_1730.jpgIMG_1731.jpgIMG_1729.jpgIMG_1732.jpg
Entry  Thu Sep 13 02:59:17 2012, Zach, Electronics, GYRO, Excess demod noise pdh2_and_demod_noise_9_12_12.png
    Reply  Thu Sep 13 10:20:36 2012, rana, Electronics, GYRO, Excess demod noise 
       Reply  Thu Sep 13 11:47:54 2012, Zach, Electronics, GYRO, Excess demod noise 
Entry  Mon Sep 17 17:22:36 2012, Zach, Electronics, GYRO, TEST channel noise reduced with AA filter TEST_AA_9_17_12.png
Entry  Wed Sep 19 03:41:21 2012, Zach, Laser, GYRO, Cataloguing, etc. layout_basic.pnglayout_full.png
Entry  Wed Sep 19 03:51:01 2012, Zach, Laser, GYRO, Stuff that happened today (and didn't) 
Entry  Thu Sep 27 02:44:34 2012, Zach, Laser, GYRO, Lock too unstable 
Entry  Wed Sep 26 03:31:51 2012, Zach, Laser, GYRO, PSL/Gyro beat setup PSL-Gyro_beat.png
    Reply  Thu Sep 27 03:33:55 2012, tara, Laser, GYRO, PSL/Gyro beat setup beat_2012_09_27
Entry  Fri Sep 28 01:15:16 2012, Zach, Laser, GYRO, Beat stuff 
Entry  Tue Oct 2 22:28:32 2012, Zach, Laser, GYRO, gyro frequency noise monitor set up beat_vs_gyro_ctrl_10_2_12.png
    Reply  Fri Oct 5 04:40:51 2012, rana, Laser, GYRO, gyro frequency noise monitor set up 
Entry  Sat Oct 13 00:32:27 2012, Koji, Things to Buy, General, Things to buy 
Entry  Fri Oct 19 18:07:10 2012, Koji, Lab Infrastructure, PEM, A huge current driver and coil magnet actuators are missing 
Entry  Sat Nov 3 13:20:27 2012, Aidan, Computing, Computing, Re-compiled Real Time Model with TCS channels Screen_Shot_2012-11-02_at_11.51.42_AM.png
Entry  Mon Nov 5 13:12:53 2012, Aidan, Computing, Computing, TCS aLIGO Real-Time model Screen_Shot_2012-11-05_at_1.08.55_PM.png
Entry  Tue Dec 18 19:01:29 2012, Koji, Misc, PMC, Impact Hammaring of Gyro Metal PMC 
Entry  Wed Mar 20 16:50:12 2013, Zach, Laser, GYRO, Gyro resurrection plan 
Entry  Wed Mar 20 17:46:43 2013, Koji, Laser, Doubling, Moved NPRO from ATF to the 40M 
Entry  Mon Mar 25 20:11:26 2013, Koji, Misc, General, Thorlabs power meter & WinCamD @56Lab 
Entry  Thu Apr 4 01:15:55 2013, Zach, Laser, GYRO, Stuff that happened last week... pmc_servo_tf_3_25_13.pngpmc_servo_noise_3_25_13.pngTEK00000.PNGpmc_oltf_3_25_13.png
Entry  Thu Apr 4 14:39:23 2013, Zach, Laser, GYRO, Primary locked 2013-04-04_13.48.29.jpg
Entry  Fri Apr 5 21:17:23 2013, Zach, Laser, GYRO, Primary OLTF, plus: PMC not working now ccw_oltf_4_4_13.png
    Reply  Sat Apr 6 15:01:03 2013, Zach, Laser, GYRO, PMC, gyro primary now locking again robustly 
Entry  Sat Apr 6 19:03:35 2013, Zach, Laser, GYRO, HVAC sucks 
Entry  Mon Apr 8 09:37:03 2013, Zach, Laser, GYRO, gyro gyroing again 2013-04-07_16.09.20.jpgoltfs_4_7_13.pnggyro_noise_4_7_13.png
    Reply  Mon Apr 8 18:41:12 2013, gyrobot, Laser, GYRO, gyro gyroing again gyrobot130408.png
Entry  Tue Apr 9 01:59:33 2013, Zach, Laser, GYRO, Previous best performance recovered gyro_noise_4_8_13.png
    Reply  Wed Apr 10 02:50:39 2013, Zach, Laser, GYRO, Current noise budget gyro_nb_4_8_13.png
Entry  Thu Apr 11 02:02:35 2013, Evan, Laser, Fiber, Fiber coupling at 10%; polarization roughly aligned mod_example.pdfellipticity.pdf
Entry  Thu Apr 11 21:01:51 2013, Evan, Laser, Fiber, Found CTN/ATF beat 
Entry  Fri Apr 12 04:34:54 2013, Zach, Laser, GYRO, New best low-frequency gyro noise gyro_noise_with_coh_4_10_13.png
Entry  Fri Apr 12 23:35:55 2013, Zach, Laser, GYRO, OOL RAM monitors set up 
Entry  Tue Apr 16 16:50:55 2013, Zach, Laser, GYRO, How to run the gyro gyro_for_dummies.pnggyrobot_rotating.jpg
Entry  Thu Apr 18 13:19:11 2013, Zach, Misc, GYRO, Throwback Thursday 2.00001.jpg
Entry  Wed May 1 00:05:49 2013, Evan, Electronics, Fiber, Beat delay line transfer function transfer_swept.pdftransfer_wn.pdf
    Reply  Wed May 1 12:01:15 2013, Zach, Electronics, Fiber, Beat delay line transfer function 
       Reply  Wed May 1 13:55:29 2013, Evan, Electronics, Fiber, Beat delay line transfer function 
    Reply  Wed May 1 21:47:20 2013, rana, Electronics, Fiber, Beat delay line transfer function 
       Reply  Wed May 1 23:36:24 2013, Evan, Electronics, Fiber, Beat delay line transfer function 
       Reply  Thu May 2 12:50:17 2013, Zach, Electronics, Fiber, Beat delay line transfer function 
          Reply  Thu May 2 23:39:08 2013, Evan, Electronics, Fiber, Beat delay line transfer function fnoisespec.pdf
             Reply  Fri May 3 01:15:15 2013, rana, Electronics, Fiber, Beat delay line transfer function 
             Reply  Fri May 3 13:45:34 2013, Zach, Electronics, Fiber, Beat delay line transfer function 
                Reply  Fri May 3 17:34:25 2013, Evan, Electronics, Fiber, Beat delay line transfer function 
Entry  Sun May 12 18:43:21 2013, Zach, Laser, GYRO, Gyro up again, but not behaving itself very well 
Entry  Mon May 13 14:08:26 2013, Zach, Computing, DAQ, C2ATF model rebuilt 
Entry  Mon May 13 15:33:33 2013, Evan, Electronics, General, Generic filter board now has G = 10 inverter with 28.8 kHz low pass op27_transfer.pdfop27_noise.pdf
Entry  Tue May 14 02:00:51 2013, Zach, Computing, DAQ, Digital PMC servo Screen_Shot_2013-05-14_at_1.54.02_AM.png
Entry  Tue May 14 21:40:38 2013, Zach, Computing, GYRO, PMC autolocker Screen_Shot_2013-05-15_at_12.50.10_AM.png
Entry  Wed May 15 00:58:17 2013, Zach, Laser, GYRO, Switched the PMC dither back to analog Screen_Shot_2013-05-15_at_12.53.06_AM.pngPMC_OLTF_5_14_13.png
Entry  Wed May 15 04:21:13 2013, Zach, Electronics, GYRO, PDH2 board fully CDS integrated (finally) 
Entry  Thu May 16 04:34:27 2013, Zach, Laser, GYRO, Gyro locking via digital control gyro_control_screen_5_15_13.pnggyro_lock_acquisition_5_15_13.png
Entry  Fri May 17 02:54:15 2013, Zach, Laser, GYRO, IT'S ALIVE!! (Or, How the Gyro Learned to Lock Itself) Screen_Shot_2013-05-17_at_2.27.26_AM.pnggyro_lock_acquisition_5_16_13.png
Entry  Fri May 17 03:34:38 2013, Zach, Misc, GYRO, Huddle testing underway huddle_test_prelim_5_16_13.png2013-05-17_03.04.12.jpg
Entry  Sun May 19 06:11:44 2013, Zach, Laser, GYRO, Low frequency still a mystery gyro_noise_5_18_13.png
Entry  Sun May 19 03:52:15 2013, Zach, Laser, GYRO, CTN PMC, ACAV relocked--can't find gyro beat 
    Reply  Sun May 19 13:07:15 2013, Evan, Laser, GYRO, CTN PMC, ACAV relocked--can't find gyro beat 
       Reply  Sun May 19 18:41:04 2013, Zach, Laser, GYRO, CTN PMC, ACAV relocked--can't find gyro beat 
          Reply  Sun May 19 19:48:30 2013, Evan, Laser, GYRO, CTN PMC, ACAV relocked--can't find gyro beat 
Entry  Mon May 20 22:44:04 2013, Koji, Misc, General, Thorlabs power meter @56Lab 
Entry  Wed May 22 02:17:00 2013, Zach, Laser, GYRO, Long-term data spectrogram.pngspect_histogram.png
Entry  Thu May 23 09:48:46 2013, Zach, Laser, GYRO, RAM subtraction subtraction_5_18_13.png
Entry  Thu May 16 22:34:13 2013, Evan, Electronics, Fiber, Beat delay line: transfer function and noise spectrum delaylinetransfer.pdfdelaylinenoise.pdf
    Reply  Thu May 23 16:05:55 2013, Evan, Electronics, Fiber, Beat delay line: transfer function and noise spectrum 
Entry  Fri May 24 19:12:07 2013, Evan, Laser, Fiber, Beat temperatures 
Entry  Thu May 23 15:43:51 2013, Evan, Laser, GYRO, Increased gyro power 
    Reply  Tue May 28 18:34:11 2013, Evan, Laser, GYRO, Decreased gyro power 
Entry  Wed May 29 17:32:06 2013, Evan, Electronics, GYRO, Shortened delay line 
Entry  Thu May 30 09:07:40 2013, Zach, Laser, GYRO, Seismometer correlation huddle_test_5_16_13.pnggyroseiscorr.pnggyroseiscorr_zoom.pnggyroseiscoh.png
Entry  Thu May 30 11:01:09 2013, Zach, Laser, GYRO, Noise vs power gnoise_vs_power.pngweinerRAM_baseline.pngccwram_vs_power.pngRAM_ts_12day.pngRAM_ts_1000s.png
Entry  Thu May 30 11:09:08 2013, Zach, Laser, GYRO, ISS does no good gyro_ISS_5_19_13.pnggyro_noise_wandwo_ISS_5_19_13.png
Entry  Fri May 31 13:30:48 2013, Zach, Computing, DAQ, atf lookback time is ~1 week 
Entry  Fri May 31 21:46:19 2013, Zach, Laser, GYRO, Noise evolution, 2010-2013 gyro_noise_evolution_2010-2013.png
Entry  Mon Jun 3 18:57:34 2013, rana, Computing, General, How to make high quality plots in Matlab makePDF.csh
    Reply  Sat Jun 8 10:40:15 2013, Aidan, Computing, General, How to make high quality plots in Matlab IDfig.m
Entry  Thu Sep 12 13:16:38 2013, Evan, Lab Infrastructure, General, Extreme Makeover: ATF Edition 2013-09-12_09.22.13.jpg
    Reply  Tue Sep 17 14:19:40 2013, Steve, Lab Infrastructure, General, use clean cover to keep optics clean 
Entry  Wed Feb 12 02:11:35 2014, Zach, Laser, GYRO, Gyro revival PMC_OLTF_2_11_14.pnggyro_CCW_OLTF_2_11_14.pnggyro_locked_medm.jpggyro_CCW_ERR_vs_boost_2_11_14.png
Entry  Fri Feb 14 03:19:06 2014, Zach, Laser, GYRO, Gyro back to life gyro_noise_2_13_14.pngPDH2_test_OLOLTF.png
Entry  Tue Feb 18 16:25:16 2014, Zach, Laser, GYRO, Best ever gyro noise, again ISS_demo_2_14_14.pngspecgram_2_16_14_0314_LF.pngspechist_2_16_14_0314_LF.pnggyro_noise_2_16_14.pnggyro_rotation_time_series_2_16_14.png
Entry  Wed Mar 5 16:08:25 2014, Zach, Laser, GYRO, RAM PD requirements 
Entry  Thu Mar 13 02:43:10 2014, Zach, Laser, GYRO, Noise nearly explained by known sources gyro_nb_3_12_14.png
Entry  Fri Mar 14 18:33:40 2014, Zach, Laser, GYRO, TO DO 
Entry  Fri Mar 14 18:13:09 2014, Zach, Laser, GYRO, Digital CW loop model.pngscreens.pngservo.pngOLTF.pnggyro_noise_vs_readout_3_13_14.png
    Reply  Fri Mar 14 19:26:09 2014, Zach, Laser, GYRO, Digital CW loop spectrogram.pngspechist.png
Entry  Thu Mar 20 02:18:13 2014, Zach, Laser, GYRO, Gyro-CTN beat recovered beat_setup.jpgbeatnote.jpggyro_ctn_beat_test_3_19_14.png
Entry  Fri Mar 21 13:50:03 2014, Zach, Laser, GYRO, Primary (CCW) RAM monitor using Gyro RFPD #3 RAM_PD_tune.jpgCCW_RAM.jpg
Entry  Tue Mar 18 23:27:53 2014, Zach, Laser, GYRO, CTN light piped through fiber 
    Reply  Sun Mar 23 00:32:21 2014, not Zach, Laser, GYRO, CTN light piped through fiber 
       Reply  Mon Mar 24 03:52:16 2014, Zach, Laser, GYRO, CTN light piped through fiber 
Entry  Wed Mar 26 15:56:02 2014, Zach, Laser, GYRO, Gyro update specgram.pngspechist.pnggsubtract.png
Entry  Thu Mar 27 23:18:54 2014, Zach, Laser, GYRO, AOM ISS ISS_layout.jpgISS_v2_3_27_14.png
Entry  Wed Mar 26 20:33:13 2014, Zach, Laser, GYRO, or: laser problems 
    Reply  Fri Mar 28 15:05:50 2014, Evan, Laser, GYRO, or: laser problems 
       Reply  Sun Mar 30 21:33:48 2014, Zach, Laser, GYRO, or: laser problems 
Entry  Fri Mar 28 20:22:04 2014, Zach, Laser, GYRO, Gyro NPRO controller bad? 
    Reply  Mon Mar 31 17:53:22 2014, Evan, Laser, GYRO, Gyro NPRO controller bad? 
Entry  Sat Apr 12 01:58:05 2014, Zach, Laser, GYRO, Gyro appears limited by true rotation gnoise_4_10_14.pnggyroseiscorr.pngshaker.jpg
    Reply  Thu Apr 17 14:05:46 2014, not Zach, Laser, GYRO, Gyro appears limited by true rotation 
       Reply  Tue Apr 22 23:55:36 2014, Zach, Laser, GYRO, Gyro appears limited by true rotation gyro_seismometers.jpg
Entry  Mon May 5 20:08:59 2014, Zach, Laser, GYRO, Can't make good seismometer data anymore almost_huddle.png
Entry  Thu May 15 15:26:23 2014, Zach, Laser, GYRO, Seismometers foamified 7x
Entry  Mon May 19 03:48:10 2014, Zach, Laser, GYRO, Seismometer filtering gyroseismofilt_5_18_14.pngrealtime_filt.png
    Reply  Mon May 19 22:19:21 2014, rana, Laser, GYRO, Seismometer filtering 
Entry  Fri Jun 13 02:18:48 2014, Zach, Laser, GYRO, Intensity noise from shifted beam intensity_noise_6_12_14.png
Entry  Wed Jun 18 02:55:09 2014, Zach, Laser, GYRO, Gyro noise better by 10x *NOPE* gyro_noise_6_17_14.pdfdual_ISS.png
    Reply  Thu Jun 19 00:51:54 2014, Koji, Laser, GYRO, Gyro noise better by 10x *NOPE* 
       Reply  Fri Jun 20 09:19:41 2014, rana, Laser, GYRO, Gyro noise better by 10x *NOPE* 
Entry  Thu Jun 19 04:55:40 2014, Zach, Electronics, GYRO, Marconi noise via digital PLL PLL_model.pngmarconi_beat_time_series_digital_PLL.pdfmarconi_noise_digital_PLL.pdf
    Reply  Fri Jun 20 16:37:13 2014, Zach, Electronics, GYRO, Marconi noise via digital PLL IQ_RF.jpgIQ_LF.jpgMarconi_beat_noise_different_analyses.pdf
       Reply  Sat Jun 21 01:15:39 2014, Zach, Electronics, GYRO, Marconi noise measurement verification Marconi_noise_verification_A.pdf
          Reply  Sun Jun 22 12:38:44 2014, rana, Electronics, GYRO, Marconi noise measurement verification 
             Reply  Mon Jun 23 14:16:35 2014, Zach, Electronics, GYRO, Marconi noise measurement verification 
                Reply  Tue Jun 24 10:47:35 2014, rana, Electronics, GYRO, Marconi noise measurement verification 
                   Reply  Tue Jun 24 19:13:35 2014, Zach, Electronics, GYRO, Marconi noise measurement verification 
Entry  Thu Jun 26 14:48:58 2014, Zach, Laser, stuff happens, Calibration error ruins the day 
Entry  Mon Aug 4 10:27:45 2014, Evan, Electronics, FSS, LTSpice simulation of AD829 inverters ad829_invert.pdfad829inv.zipad829_components.png
Entry  Wed May 21 11:11:08 2014, Evan, Things to Buy, PMC, 1064 nm PMC specs pmcdiag.pdfhomVersusLength.pdf
    Reply  Sun Aug 17 15:49:22 2014, Evan, Things to Buy, PMC, 1064 nm PMC 
Entry  Fri Nov 21 01:31:58 2014, Zach, Electronics, M2 ISS, Board stuffed, testing begun 20141120_213037.jpgM2_bias_noise_11_20_14.pngM2_11_12_14.pdf
    Reply  Wed Nov 26 17:46:28 2014, Zach, Electronics, M2 ISS, Board stuffed, testing begun M2_bias_noise_11_25_14.png
Entry  Wed Dec 3 18:31:15 2014, Kate, Lab Infrastructure, , First tilt-free seismometer entry SuspensionFrameOrder.pdf
Entry  Tue Dec 16 21:36:07 2014, Kate, Laser, , Fiber coupler work 
Entry  Fri Dec 19 12:22:37 2014, rana, Lab Infrastructure, General, overhead lights 
Entry  Wed Dec 3 14:28:53 2014, Zach, Electronics, M2 ISS, M2 bias/readout board evaluation M2_noise_evaluation_12_1_14.pdf
    Reply  Wed Dec 3 19:37:09 2014, Zach, Electronics, M2 ISS, LT1128 current noise M2_noise_vs_LT1128_batch_12_3_14.pngM2_input_noise_vs_LT1128_batch_12_3_14.pngexcess_LT1128_inoise_in_aLIGO_DCPD_12_3_14.png
    Reply  Tue Dec 23 19:58:49 2014, rana, Electronics, M2 ISS, M2 bias/readout board evaluation 
Entry  Thu Jan 15 09:01:25 2015, Stephanie, Kate, Computing, Seismometer, CAD and FEA for Seismometer Prototype_1_Drawing.PDFModal_Frequencies_of_Aluminum_Frames_using_ANSYS.pptx
Entry  Wed Jan 21 15:27:08 2015, Kate, Misc, Seismometer, 1 dof seismometer noise budget Screen_Shot_2015-01-21_at_2.16.12_PM.pngScreen_Shot_2015-01-21_at_2.10.05_PM.pngIMG_0432.JPGIMG_0432.JPG
Entry  Fri Jan 23 15:33:46 2015, Kate, Alastair, Misc, Seismometer, Pin vise holder, version 1 SCAN7247_000.pdf
Entry  Fri Jan 23 15:46:13 2015, Kate, Alastair, Misc, Seismometer, Steel wire for seismometer image.png
Entry  Mon Jan 26 15:58:18 2015, Kate, Misc, Seismometer, Determining tilt/translation couplings SCAN7248_000.pdfSCAN7250_000.pdf
Entry  Wed Feb 4 16:56:38 2015, Stephanie, Kate, Computing, Seismometer, Frame Design Comparisons Modal_Frequencies_of_Aluminum_Frames_using_ANSYS.pptxgraph.pngmodal_freequencies.pngframes.jpg
Entry  Thu Jan 29 15:54:26 2015, Kate, Misc, Seismometer, Seismometer work update SCAN7252_000.pdfSCAN7253_000.pdf
    Reply  Wed Feb 4 17:53:58 2015, Kate, Misc, Seismometer, Seismometer work update SCAN7270_000.pdfSCAN7271_000.pdf
Entry  Wed Feb 4 18:09:22 2015, Kate, Misc, Seismometer, Some Mathematica modeling for a driven, suspended block SCAN7272_000.pdfSCAN7274_000.pdfkate_pendulum.nb
    Reply  Fri Feb 6 13:10:22 2015, Kate, Misc, Seismometer, Some Mathematica modeling for a driven, suspended block Screen_Shot_2015-02-06_at_12.36.04_PM.pngScreen_Shot_2015-02-06_at_12.41.04_PM.pngScreen_Shot_2015-02-06_at_1.08.21_PM.pngpendulum_basic.zip
Entry  Tue Feb 10 22:15:42 2015, Kate, Misc, Seismometer, Seismometer mass and pin vise clamp  SCAN7283_000.pdfIMG_0441.JPGIMG_0442.JPG
Entry  Mon Mar 9 18:57:21 2015, Kate, Stephanie, Misc, Seismometer, Updated tilt-free seismometer design concept Seismometer_2.jpgIMG_0476.JPGIMG_0477.JPG
    Reply  Wed Mar 11 15:12:51 2015, Kate, Stephanie, Misc, Seismometer, Updated tilt-free seismometer design concept Seismometer2.EASMSeismometer_1.jpgSeismometer_2.jpg
Entry  Thu Apr 2 23:24:19 2015, Kate, Stephanie, Misc, Seismometer, Design of low rotational freq. mass drawing.pngdrawing.svg
Entry  Wed Feb 18 21:08:56 2015, Stephanie, Kate, Misc, Seismometer, Finding Modal Frequencies of Frame Accelerometer.jpgAccelerometer1.jpg
    Reply  Fri Feb 20 16:58:55 2015, Stephanie, Kate, Misc, Seismometer, Finding Modal Frequencies of Frame Frequency_Spectrum.jpgFrequency_Spectrum.jpg
       Reply  Sun Feb 22 01:49:11 2015, rana, Misc, Seismometer, Finding Modal Frequencies of Frame 
          Reply  Tue Feb 24 11:33:28 2015, Stephanie, Kate, Misc, Seismometer, Finding Modal Frequencies of Frame lab_setup.jpgAccelerometer_on_frame.jpg
             Reply  Wed Feb 25 18:03:42 2015, Stephanie, Kate, Misc, Seismometer, Finding Modal Frequencies of Frame Accelerometer_Ziptie.JPGTesting_spots.JPGaccelerometerdata.zip
                Reply  Wed Apr 1 17:21:44 2015, Stephanie, Kate, Misc, Seismometer, Finding Modal Frequencies of Frame HighBarPlot_ID_Peaks.jpgMiddleBarPlot_ID_Peaks.jpgData_8_Lorentzian.jpgData_14_Lorentzian.jpgPeak_Freq_and_Q_factor(1).xlsx
          Reply  Fri Apr 3 16:22:12 2015, Steve, Misc, Seismometer, PZT buzzer 
Entry  Thu Apr 16 15:21:11 2015, Kate, Alastair, Misc, Seismometer, Fiber pulling lesson (belated entry) IMG_0457.MOV
Entry  Sat Apr 25 00:21:30 2015, Stephanie, Kate, Misc, Seismometer, Modal Frequency Simulation Hanging_Pendulum_3D_Rendering.JPG
Entry  Wed Apr 29 17:57:38 2015, Kate, Misc, Seismometer, Preliminary Michelson design to prompt discussion MichelsonTopView.pdf
Entry  Thu Apr 30 21:41:38 2015, Kate, Misc, Seismometer, Analytic estimate of primary mass moments of inertia and frequencies MOI.m
Entry  Sat May 9 13:30:58 2015, Stephanie, Kate, Misc, Seismometer, ANSYS Videos and Building Update Frame1.JPGFrame2.JPGRhomboid_Modes_Videos.zipRhomboid.EASM
    Reply  Mon May 11 18:38:14 2015, rana, Misc, Seismometer, ANSYS Videos and Building Update 
Entry  Thu May 14 20:23:59 2015, Stephanie, Kate, Misc, Seismometer, The rhomboid is suspended IMG_0884.JPGIMG_0903.JPGIMG_0898.JPG
Entry  Fri May 15 22:34:32 2015, Kate, Misc, Seismometer, Rhomboid de-suspended for now IMG_0643.JPGIMG_0645.JPG
Entry  Wed May 27 22:51:11 2015, Kate, Misc, Seismometer, Inverted pendulum design SCAN7432_000.pdf
Entry  Wed Jun 3 15:05:19 2015, Koji, Electronics, Seismometer, QPD matrix circuit P6037723.jpgP6037719.jpgP6037720.jpgP6037721.jpg
Entry  Sat Jun 6 01:52:14 2015, Stephanie, Kate, Misc, Seismometer, Rhomboid Suspension Using Two Wires IMG_0791.JPGIMG_0794.jpgIMG_0795.jpgIMG_0797.jpg
Entry  Mon Jun 1 18:26:01 2015, rana, Lab Infrastructure, HVAC, hot spots in lab - hot air coming from Gyro table HEPA 
    Reply  Mon Jun 8 16:30:24 2015, Kate, Lab Infrastructure, HVAC, hot spots in lab - hot air coming from Gyro table HEPA 
Entry  Thu Jun 11 22:43:08 2015, Stephanie, Kate, Misc, Seismometer, Rhomboid Suspension Using Two Wires (Shorter Distance at Top) 
Entry  Wed Jun 10 13:48:22 2015, Kate, Computing, Computing, WS1 log in problem IMG_0803.JPG
    Reply  Fri Jun 12 12:23:14 2015, Kate, Computing, Computing, WS1 log in problem 
Entry  Fri Jun 12 20:17:39 2015, Stephanie, Kate, Misc, Seismometer, Equal Lengthed Wires IMG_1092.JPGIMG_1093.JPGWire_Plate.PDF
Entry  Tue Jun 16 01:26:11 2015, Stephanie, Kate, Misc, Seismometer, CAD of Updated Assembly and Thermal Enclosure 06_11_Assembly_and_Thermal_Enclosure_Pics.zip06_11_Assembly.EASM06_11_Thermal_Enclosure.EASMScreen_Shot_2015-06-16_at_3.45.13_PM.png
Entry  Wed Jun 17 18:05:42 2015, Arjun, Electronics, PD noise, Resistor noise observations,analysis and inference 25x
    Reply  Thu Jun 18 22:24:31 2015, rana, Electronics, PD noise, Resistor noise observations,analysis and inference 
Entry  Wed May 20 21:33:36 2015, rana, Misc, Seismometer, Thermal Enclosure concept ThermalEnclosure.pdf
    Reply  Tue Jun 16 17:09:46 2015, rana, Misc, Seismometer, Thermal Enclosure concept 
       Reply  Fri Jun 19 16:54:39 2015, Kate, Misc, Seismometer, Thermal Enclosure concept 
Entry  Fri Jun 19 18:29:31 2015, Megan, Misc, Seismometer, Building the seismometer frame 
Entry  Sat Jun 20 00:47:40 2015, Arjun , Misc, PD noise, Setting up of mechanical parts for PD noise measurement IMG_20150620_002445.jpgScreenshot_2015-06-20-01-05-14[1].pngScreenshot_2015-06-20-02-37-38[1].png
Entry  Mon Jun 22 18:22:26 2015, Arjun, Misc, PD noise, Cross-Correlation scheme to calculate PD noise 13x
Entry  Tue Jun 23 11:34:28 2015, Kate, Misc, Seismometer, Upper pin vise clamp (drawing) SCAN7472_000.pdf
Entry  Wed Jun 24 17:02:03 2015, Megan, Misc, Seismometer, Further details on seismometer design 
Entry  Thu Jun 25 15:22:19 2015, Kate, Misc, Seismometer, More thermal enclosure parts purchased 
Entry  Thu Jun 25 15:36:54 2015, Arjun, Misc, PD noise, Updates on PD noise setup 9x
Entry  Thu Jun 25 18:31:11 2015, Arjun, Misc, PD noise, Resistor noise measurements using the cross correlation method 7x
Entry  Fri Jun 26 11:19:24 2015, Megan, Misc, Seismometer, Thermal Calculations for Seismometer Housing 
Entry  Fri Jun 26 13:41:28 2015, Megan, Misc, Seismometer, More on the seismometer frame image1-1.JPGimage2-1.JPG
    Reply  Fri Jun 26 17:32:16 2015, Kate, Misc, Seismometer, More on the seismometer frame 
Entry  Mon Jun 29 11:13:21 2015, Megan, Misc, Seismometer, Time constant for heating the seismometer frame 
Entry  Mon Jun 29 16:59:47 2015, Arjun, Misc, PD noise, Pre-stabilisation of laser  6x
Entry  Tue Jun 9 19:39:03 2015, Koji, Electronics, General, Nick Lockerbie's precision current driver current_driver.png
    Reply  Mon Jun 29 21:28:46 2015, Koji, Electronics, General, 2ch Photo Sensor circuit PS_Calib.pngPS_Dark_noise.pngPS_DC_OUT.pngPS_AC_OUT.pngPS_Disp_Noise.png
Entry  Fri Jun 26 18:02:17 2015, Kate, Alastair, Megan, Misc, Seismometer, Suspension attempt IMG_0823.JPG
    Reply  Tue Jun 30 15:43:49 2015, Steve, Misc, Seismometer, pin vises 
Entry  Tue Jun 30 16:24:06 2015, Megan, Kate, Misc, Seismometer, Rhomboid is suspended IMG_5072.JPGIMG_5074.JPGIMG_5075.JPG
Entry  Wed Jul 1 17:31:16 2015, Arjun, Misc, PD noise, Updates on PD noise setup IMG_20150630_192049.jpgIMG_20150630_192321.jpgIMG_20150630_192049.jpgIMG_20150630_192313.jpg
Entry  Mon Jul 6 08:15:53 2015, rana, Misc, TempCtrl, temperature noise plot tempnoise_final.pdf
Entry  Mon Jul 6 13:27:48 2015, rana, Misc, Seismometer, Inverted Pendulum links 
Entry  Mon Jul 6 17:10:54 2015, Megan, Misc, Seismometer, Holes drilled in aluminum sheeting IMG_5102.JPGIMG_5103.JPG
Entry  Mon Jul 6 19:52:28 2015, Kate, Alastair, Megan, Misc, Seismometer, Ideas for new pin vise clamp IMG_0834.JPG
Entry  Tue Jul 7 11:48:21 2015, Alastair, Kate, Megan, Misc, Seismometer, Drawings for upper clamp PIn.pdfTop_Plate2.pdfclamping_plate.pdf
Entry  Wed Jul 8 18:32:51 2015, Arjun, Misc, PD noise, PD noise update 6x
Entry  Thu Jul 9 00:37:35 2015, Kate, Alessandra, Electronics, Seismometer, PCB IMG_1128.JPGIMG_1130.JPGIMG_1131.JPG
Entry  Thu Jul 9 09:51:49 2015, Alastair, Kate, Megan, Misc, Seismometer, New upper clamp Top_Plate2.pdfclamping_plate.pdfPIn.pdfAssem1_-_Sheet1.pdf
Entry  Thu Jul 9 10:29:49 2015, Megan, Misc, Seismometer, Heater test, more panel work IMG_5113.JPGIMG_5114.JPGIMG_5112.JPG
Entry  Thu Jul 9 14:35:30 2015, Alessandra, Misc, Seismometer, Inverted pendolum 
Entry  Fri Jul 10 00:59:49 2015, Arjun, Misc, PD noise, PD-noise update 6x
Entry  Sun Jul 12 02:00:15 2015, Arjun, Misc, PD noise, PD noise Update fig1.pdfIMG_20150711_161731.jpgIMG_20150711_161741.jpgIMG_20150711_161726.jpgIMG_20150711_204122.jpg
Entry  Mon Jul 13 16:47:46 2015, Arjun, Misc, PD noise, Noise Plots 6x
Entry  Tue Jul 14 13:49:56 2015, Megan, Misc, Seismometer, Seismometer thermal housing taking shape IMG_5149.JPGIMG_5151.JPGIMG_5152.JPGIMG_5153.JPGIMG_5155.JPG
Entry  Tue Jul 14 20:55:50 2015, Arjun, Misc, PD noise, Some thoughts on the intensity stabilization servo 
Entry  Wed Jul 15 11:29:11 2015, Megan, Misc, Seismometer, Thermal housing walls progress IMG_5180.JPGIMG_5181.JPGIMG_5182.JPG
Entry  Wed Jul 15 13:40:38 2015, Arjun, Misc, PD noise, Intensity stabilization servo 
Entry  Wed Jul 15 15:45:04 2015, Arjun, Misc, PD noise, Intensity Servo design TF_intensity_servo_remain.pngfilter.pdfOLG.pdf
Entry  Wed Jul 15 16:32:50 2015, Megan, Misc, Seismometer, More enclosure sides done IMG_5184.JPGIMG_5183.JPG
Entry  Wed Jul 15 22:14:19 2015, Arjun, Misc, PD noise, Intensity Servo design 
Entry  Wed Jul 15 23:17:14 2015, Alessandra, Misc, Seismometer, Rhomboid motion Sensors.JPGfoto_.JPGfoto_(1).JPG
    Reply  Thu Jul 16 10:21:39 2015, Koji, Misc, Seismometer, Optical lever installation (Re: Rhomboid motion) 
Entry  Fri Jul 17 11:29:57 2015, Alessandra, Misc, Seismometer, QPD calibration Calibrazione_QPD.JPG
    Reply  Fri Jul 17 11:51:46 2015, Koji, Misc, Seismometer, QPD calibration 
Entry  Thu Jul 16 18:28:53 2015, Arjun, Misc, PD noise, PD noise update Sim_vs_Obs_OLG.figSim_vs_Obs_OLG.pdfNoise_plots.figNoise_plots.pdf
    Reply  Fri Jul 17 18:12:36 2015, rana, Misc, PD noise, PD noise update 
       Reply  Sat Jul 18 22:24:08 2015, Arjun, Misc, PD noise, PD noise update 
Entry  Thu Jul 23 16:35:05 2015, Arjun, Misc, PD noise, PD noise update Intensity_supp.figIntensity_supp.pdf
Entry  Thu Jul 23 17:11:18 2015, Arjun, Misc, PD noise, CMRR of the PDs 
Entry  Fri Jul 24 15:55:05 2015, Megan, Misc, Seismometer, Mini thermal enclosure test IMG_5371.JPGFullSizeRender.jpgIMG_5374.JPGIMG_5373.JPG
    Reply  Fri Jul 24 17:59:39 2015, rana, Misc, Seismometer, Mini thermal enclosure test 
Entry  Mon Jul 27 16:15:24 2015, Megan, Misc, Seismometer, DB 25 Punches IMG_5402.JPG
Entry  Tue Jul 28 16:32:38 2015, Alessandra, Misc, Seismometer, IP spring constant and resonant frequency foto_IP.jpgfoto_forza.jpgIP_displacement.jpganalisi_forze.jpgf_ip_m_3.jpg
Entry  Thu Jul 30 16:35:00 2015, Megan, Misc, Seismometer, Initial test of new heaters IMG_5407.jpgtemp_data_theory.jpg
Entry  Fri Jul 31 15:21:19 2015, Alessandra, Misc, Seismometer, QPD calibration x_axis_qpd_cal.jpgx_qpd_cal_erf.jpgy_linear.jpgy_erf_fit.jpg
Entry  Tue Aug 4 10:43:21 2015, Aidan, Computing, General, FB0 unresponsive. Rebooting. 
Entry  Tue Aug 4 16:13:03 2015, Alessandra, Misc, Seismometer, IP parameters f_ip_bottom_cy.jpgf_ip_40mhz.jpg
Entry  Tue Aug 4 17:22:40 2015, Megan, Misc, Seismometer, Thermal enclosure progress IMG_5428.jpgIMG_5432.jpgIMG_5431.jpg
Entry  Wed Aug 5 15:20:44 2015, Megan, Misc, Seismometer, Enclosure has feet! 6x
Entry  Fri Aug 7 10:39:44 2015, Megan, Misc, Seismometer, Michelson layout diagram michelson_layout_diagram.jpg
Entry  Sat Aug 8 19:05:38 2015, Koji, Misc, General, Inverted pendulum 10mm rod holder 10mm_Rod_Holder.pdf
Entry  Mon Aug 10 11:15:28 2015, Megan, Misc, Seismometer, Second Michelson layout diagram michelson_layout_diagram_2.jpg
Entry  Wed Aug 12 14:04:47 2015, Alessandra, Misc, Seismometer, Breadboard and IP top mass dimentions breadboard.psip_mass.ps
Entry  Wed Aug 12 16:04:22 2015, Megan, Misc, Seismometer, Light through fiber + beam scans IMG_5463.jpgbeam_scan_1.pdfIMG_5464.jpgbeam_scan_2.pdf
Entry  Wed Aug 12 16:28:20 2015, Megan, Misc, Seismometer, Michelson layout diagram - Final (?) version michelson_layout_diagram_3.pdf
Entry  Thu Aug 13 13:12:48 2015, Rich Abbott, Electronics, FSS, TTFSS Fieldbox, Mysteries Revealed TTFSS_Fieldbox.pdf
Entry  Thu Aug 13 18:55:27 2015, Alessandra, Misc, Seismometer, Parameters for the new shape of the IP ip_block.jpgf_ip_a.jpgf_ip_b.jpgIa.jpgIb.jpg
Entry  Wed Aug 19 19:14:03 2015, Alessandra, Misc, Seismometer, Thermal enclosure tests temperature.pngtemp_decr.png
Entry  Fri Aug 21 22:59:00 2015, Koji, Misc, Seismometer, Started continuous data taking 
Entry  Sat Aug 22 18:36:50 2015, Alessandra, Misc, Seismometer, Temperature stabilization 22_to_23.png23_to_22.png
Entry  Thu Aug 27 15:09:12 2015, Alessandra, Misc, Seismometer, IP measurements IMG_1974.JPGP8270027.JPGIMG_1970.JPGIMG_1971.JPG
Entry  Mon Aug 31 20:32:57 2015, Alessandra, Misc, Seismometer, IP final parameters single_flexure.pngdouble_flexure.png
Entry  Wed Sep 16 04:43:35 2015, Koji, Misc, Seismometer, IP test at the 40m IMG_20150914_181922982.jpgIMG_20150914_182024785_HDR.jpgIMG_20150914_182037693.jpgIMG_20150914_182550377.jpgIMG_20150914_181825903_HDR.jpg
Entry  Thu Feb 4 21:23:31 2016, KojiN, Misc, PD QE, Preparation of some components 2016-02-04_21.12.47.jpg
Entry  Fri Feb 5 21:06:14 2016, KojiN, Misc, PD QE, Initial alignment of optics 2016_02_05_setup.png
Entry  Tue Feb 9 00:00:11 2016, KojiN, Misc, PD QE, Measurement of a beam profile setup.pngBeamProfile.jpgBeamAfterPBS.pdf
Entry  Wed Feb 10 00:17:31 2016, KojiN, Misc, PD QE, Alignment of the single mode fiber and re-measurement of the beam profile 2016_02_09_setup.pngRoundBeam.jpgBeamAfterFiber.png
Entry  Thu Feb 11 00:03:24 2016, KojiN, Misc, PD QE, Beam Adjustment 2016_02_10_setup.pngTargetBeam.pngBeamAfterLenses.pngBeamProfileScreen.jpg
Entry  Thu Feb 11 23:54:48 2016, KojiN, Misc, PD QE, Polarization measurement 2016_02_11_setup.pngpol.png
Entry  Sun Feb 14 01:04:07 2016, KojiN, Misc, PD QE, Measurement of PD reflectivities and PD efficiencies for P-pol. and S-pol. 2016_02_12_setup.pngReflctivity2.pngQE2.png
Entry  Tue Feb 16 23:51:31 2016, KojiN, Misc, PD QE, Re-measurement of the PD efficiencies for P-pol. and S-pol. 2016_02_16_setup.pngQE.pngD980454-00(QE).pdfD980454-00(QE)_2.pdfD980454-00(QE).pdf
Entry  Thu Feb 18 08:12:53 2016, KojiN, Misc, PD QE, Re-measurement of the reflectivities and the EQEs of the PD for S-pol and P-pol QE3.pdfQE_ll.pdf
    Reply  Thu Feb 18 13:39:33 2016, Koji, Misc, PD QE, Re-measurement of the reflectivities and the EQEs of the PD for S-pol and P-pol 
       Reply  Fri Feb 19 00:01:36 2016, KojiN, Misc, PD QE, Re-measurement of the reflectivities and the EQEs of the PD for S-pol and P-pol 6x
Entry  Fri Feb 19 00:39:24 2016, KojiN, Misc, PD QE, First QE measurement with the reflector QE_enh.txtQE_enh.pdf
Entry  Fri Feb 19 20:25:14 2016, KojiN, Misc, PD QE, Measurement of the enhanced QE of the PD without glass window  QE_enh.pdfQE_enh2.pdfQE_enh.txtQE_enh_ref.txtQE_enh_cal_NK.m
    Reply  Sun Feb 21 14:27:24 2016, rana, Misc, PD QE, Measurement of the enhanced QE of the PD without glass window  
       Reply  Sun Feb 21 21:16:10 2016, KojiN, Misc, PD QE, Measurement of the enhanced QE of the PD without glass window  2016_02_19_setup.pdf
          Reply  Sun Feb 21 21:53:04 2016, KojiN, Misc, PD QE, Measurement of the enhanced QE of the PD without glass window  
Entry  Sun Feb 21 22:02:01 2016, Koji Antonio,, Misc, PD QE, PD window removal few notes Screen_Shot_2016-02-21_at_8.34.59_PM.pngScreen_Shot_2016-02-21_at_8.34.43_PM.pngScreen_Shot_2016-02-21_at_8.34.43_PM.png
Entry  Mon Feb 22 23:51:18 2016, KojiN, Misc, PD QE, Beam shape reflected by the PD BeamAt15deg15cm.pdfBeamAt45deg15cm.pdf
Entry  Tue Feb 23 00:22:01 2016, KojiN, Misc, PD QE, Re-measurement of the QE of the PD without window glass 6x
Entry  Wed Feb 24 08:18:06 2016, KojiN, Misc, PD QE, Systematic error of the power meter (RM9, Ophir) RM9_RM9-PD_0.pdf
Entry  Wed Feb 24 23:51:07 2016, KojiN, Misc, PD QE, Test of the BRDF measurement BRDF_mes.pdfBRDFat0deg.pdfBRDFat0deg2.pdfBRDFat0deg.txtBRDF.m
Entry  Fri Feb 26 10:00:18 2016, KojiN, Misc, PD QE, BEDF measurement for wide angle BRDF_setup.pdfBRDFat0deg_log.pdfBRDFat30deg_log.pdfBRDF_log_P.pdf
Entry  Fri Feb 26 23:13:02 2016, KojiN, Misc, PD QE, BRDF measurement around the peak BRDF_log.pdfBRDF_setup_fine.pdf
    Reply  Sun Feb 28 15:47:06 2016, KojiN, Misc, PD QE, BRDF measurement around the peak BRDF_log_compare.pdfBRDF_log_all_wide.pdfBRDF_log_all_narrow.pdfBRDFat30deg.txtBRDFat30deg_again.txt
Entry  Wed Mar 2 13:07:36 2016, KojiN, Misc, PD QE, Distance between the 1st incident beam and the 2nd reflected beam Beam_Position.pdf
Entry  Fri Feb 19 20:15:03 2016, KojiN, Misc, PD QE, Measurement of the reflectivity, EQE, and IQE of the PD without glass window  Ref.pdfQE.pdfQE2.pdfRef_QE_wow.txtQE_cal3_NK.m
    Reply  Mon Feb 29 08:19:53 2016, KojiN, Misc, PD QE, Measurement of the reflectivity, EQE, and IQE of the PD without glass window  Reflectivity.pdfRef_wow_again.txt
       Reply  Wed Mar 2 14:38:31 2016, KojiN, Misc, PD QE, Measurement of the reflectivity, EQE, and IQE of the PD without glass window  QE3.pdfQE_ratio2.pdf
Entry  Fri Mar 4 16:18:45 2016, Koji, Misc, General, Photos of the experiment 
Entry  Tue Mar 1 09:12:51 2016, KojiN, Misc, PD QE, Measurement of the BRDF with the Iris in the incident path BRDF_setup.pdfBRDF_withIris.pdf
    Reply  Wed Mar 2 10:17:56 2016, KojiN, Misc, PD QE, Measurement of the BRDF with the Iris in the incident path BRDF_chopper_setup.pdfBRDF_with_chopper.pdfPD_darknoise.pdf
       Reply  Sat Mar 5 01:42:02 2016, KojiN, Misc, PD QE, Measurement of the BRDF with the Iris in the incident path BRDF_with_chopper.pdf
Entry  Sun Mar 6 02:25:47 2016, Koji, Misc, General, PD glass reflections  
Entry  Tue Mar 1 09:55:28 2016, KojiN, Misc, PD QE, Estimation of the back scattering BackSca_setup.pdfBRDF_enh.pdfBRDF_enh2.txt
    Reply  Sun Mar 6 10:19:14 2016, KojiN, Misc, PD QE, Estimation of the back scattering setup.pdfref_ps.pdfBackscat.pdfBackScat2.pdf
Entry  Mon Mar 7 15:34:46 2016, KojiN, Misc, PD QE, Back reflection measurement with the chopper setup.pdfBRDF_cal.pdf
    Reply  Mon Mar 7 15:47:03 2016, KojiN, Misc, PD QE, Back reflection measurement with the chopper 
Entry  Wed Jun 22 13:42:38 2016, awade, Misc, , New silicon sample (8616P Tang) arrived: initial unbox and check 12x
Entry  Wed Jun 29 17:16:38 2016, Zach, Misc, General, Gyro optics lent to Den @ MIT 
Entry  Fri Jul 1 20:02:44 2016, awade, Misc, Scatterometer, Starting on the Si scatter measurements. 
Entry  Mon Jul 18 17:15:17 2016, awade, Misc, Purchases, Received 2 um FC/APC fiber coupled Faraday 20160718_Datasheet_Thorlabs_IO-F-2000APC_FI.pdf20160718_PackingSlip_PO_SalesOrder-TS1607283.pdf2016-07-18_17.03.28.jpg
Entry  Thu Jul 28 16:44:18 2016, awade, Laser, Purchases, Received 2 um FC laser diode 20160728162824592.pdf
Entry  Sun Jul 31 09:06:43 2016, Aidan, Computing, TempCtrl, Template PID servo script from eLIGO days PIDChillerServo.pl
Entry  Mon Aug 1 15:33:25 2016, Aidan, Misc, ANTS!, It's summer. The ants are back. I have laid down some ant bait 
Entry  Mon Aug 8 00:31:59 2016, rana, Computing, General, Wiki upgrade 
Entry  Mon Aug 8 17:05:28 2016, rana, Misc, General, Raspberry Pi beam profiles: possible student project 
    Reply  Tue Aug 16 16:01:21 2016, awade, Misc, General, Raspberry Pi beam profiles: possible student project 
Entry  Mon Jul 18 11:30:31 2016, awade, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 
    Reply  Wed Aug 3 18:46:13 2016, rana, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 1772-NM-40-02-FC-PM.pdf
       Reply  Tue Aug 9 22:04:25 2016, awade, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 
          Reply  Thu Aug 11 12:23:49 2016, awade, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig plot20160811_Emcore1772_CurrentVsPower)_ThenAndNow.epsEmcore1772_CurrentVsPower.ipynb
             Reply  Mon Sep 19 21:07:21 2016, awade, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 20160919_ScatterometerBasicSetup.pdfCageTypeHolderAssmbly.JPGUHolderCradle_v5.PDF
                Reply  Tue Sep 20 22:19:54 2016, rana, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 
                   Reply  Tue Oct 4 12:05:05 2016, awade, Misc, Scatterometer, Gathering parts: 1550 nm scatter rig 100_0230.JPG100_0233.JPG100_0236.JPG
Entry  Thu Sep 29 08:21:07 2016, Aidan, Laser, 2micronLasers, Two micron fiber set-up (dry run) PastedGraphic-1.pdfIMG_7260.JPGIMG_7259.JPG
    Reply  Wed Oct 5 10:50:24 2016, rana, Laser, Fiber, frequency noise oe-18-22-22781-g007.pdf
Entry  Mon Oct 24 16:55:24 2016, awade, Things to Buy, Scatterometer, Summary of InGaAs cameras 
Entry  Thu Nov 10 19:04:28 2016, awade, Update, Scatterometer, Testing InGaAs camera 2016-11-09_18.05.48.jpg2016-11-09_18.05.55.jpg
Entry  Tue Jan 5 14:48:08 2016, rana, SafetyLab Infrastructure, HVAC, heating and cooling 
    Reply  Wed Nov 9 16:58:19 2016, awade, Lab Infrastructure, HVAC, heating and cooling 
       Reply  Thu Nov 10 21:33:38 2016, awade, Lab Infrastructure, HVAC, heating and cooling 
          Reply  Fri Nov 11 13:30:55 2016, awade, Lab Infrastructure, HVAC, heating and cooling 
Entry  Fri Dec 16 12:41:50 2016, awade, Lab Infrastructure, General, Rain, lab checkup 
Entry  Tue Jan 3 16:27:41 2017, Aidan, Laser, TMTF, Two micron test facility - v1: mocked up and locked IMG_8458.JPGIMG_8459.JPGTMTF_rev1.png
    Reply  Tue Jan 3 20:15:12 2017, rana, Laser, TMTF, fiber based laser phase noise measurements 
       Reply  Tue Jan 3 23:32:33 2017, awade, Laser, TMTF, fiber based laser phase noise measurements 
Entry  Wed Jan 25 11:41:55 2017, Aidan, Computing, Cymacs, Pulled old IO chassis and FB0 IMG_8643.JPG
Entry  Sat Jan 28 13:02:40 2017, rana, Things to Buy, CDS, cheap DAQ 
Entry  Wed Apr 5 11:54:31 2017, Aidan, Computing, PEM, Temperature data being written to file IMG_9115.JPG
Entry  Tue Apr 11 16:13:38 2017, awade, Computing, PEM, Replaced batteries in newport datalogger unit PSL lab 
Entry  Wed Apr 19 10:57:42 2017, rana, Laser, GYRO, laser to Liyuan 
Entry  Fri Apr 21 16:06:51 2017, Aidan, Electronics, Cameras, Phosphor coated camera shows ZERO response at 2004nm 
Entry  Wed Apr 26 18:40:30 2017, rana, Computing, General, ATF Wiki updated 
Entry  Fri Apr 28 13:54:35 2017, Aidan, Laser, PD QE, DET10D QE at 2004nm measured (it was 0.79) DET10D_QE.pdfIMG_9396.JPGIMG_9395.JPGIMG_9394.JPG
Entry  Wed Apr 19 14:34:10 2017, Aidan, Laser, TMTF, Eblana laser diode intensity noise spectra eblana_noise_intensity.pdf20170418_Eblana_intensity_noise.asc20170418_DET10D_dark_noise.asc
    Reply  Thu Apr 20 13:26:23 2017, rana, Laser, TMTF, DET-10 thoughts DET10D.pdf
       Reply  Tue May 2 11:11:16 2017, Aidan, Laser, TMTF, DET-10 intensity noise - round 2 eblana_noise2_intensity.pdf
          Reply  Tue May 2 11:15:41 2017, Aidan, Laser, TMTF, DET-10 intensity noise - round 2 
Entry  Tue May 2 08:26:30 2017, Aidan, Andrew, Laser, PD QE, QE of regular InGaAs photodetectors is 16ppm at 2004nm 
    Reply  Tue May 2 14:08:52 2017, Aidan, Andrew, Laser, PD QE, QE of regular InGaAs photodetectors is 16ppm at 2004nm Screen_Shot_2017-05-02_at_2.10.30_PM.png
Entry  Tue May 2 15:31:24 2017, Aidan, Computing, Cymacs, ATF Cymacs FB4 built - only OS and RTSCDS package right now 
Entry  Mon May 15 17:52:42 2017, Dhruva, Laser, WOPO, SURF Day 1  
Entry  Tue May 16 10:56:26 2017, awade, Misc, Purchases, SR785 (AST# C10240, SN 77060) returned from service  20170516_ServiceReport_SR785_C10240_SN77060.pdf
Entry  Tue Nov 22 11:40:40 2016, awade, Lab Infrastructure, General, Lab flooding and AC control issues 
    Reply  Tue Nov 29 16:40:14 2016, awade, Lab Infrastructure, General, Lab flooding and AC control issues 
       Reply  Thu Dec 8 20:43:44 2016, rana, Lab Infrastructure, General, Lab flooding and AC control issues 
          Reply  Sun Dec 11 17:15:29 2016, awade, Lab Infrastructure, General, Lab flooding and AC control issues 
    Reply  Wed May 17 21:24:19 2017, awade, Lab Infrastructure, General, Turned mains breaks back on 
Entry  Thu May 18 08:28:07 2017, Eric Gustafson, Lab Infrastructure, RF, 10 MHz reference distribution system planning 
Entry  Fri Apr 21 15:37:36 2017, Steve, Lab Infrastructure, RF, 10 MHz reference distribution system planning S_033W_B2_SPM_DWG_FPL_CAD_LAYER_REPORT.PDF
    Reply  Tue May 23 10:15:31 2017, Steve, Lab Infrastructure, RF, 10 MHz reference distribution system planning WBrf.jpg
       Reply  Tue May 23 15:19:48 2017, rana, Lab Infrastructure, RF, 10 MHz reference distribution system planning 
          Reply  Tue May 23 16:06:41 2017, Steve, Lab Infrastructure, RF, 10 MHz reference distribution system planning DIN_rail_pr.jpg
             Reply  Tue May 23 16:59:39 2017, rana, Lab Infrastructure, RF, 10 MHz reference distribution system planning 
                Reply  Thu May 25 11:26:45 2017, Steve, Lab Infrastructure, RF, 10 MHz reference distribution system planning WBrf2.jpg
Entry  Sat May 27 13:53:15 2017, awade, Aidan, Misc, 2micronLasers, Examining response of InGaAs CCD camera's at 2 um 13x
Entry  Thu Jun 1 19:04:14 2017, Dhruva, Computing, WOPO, Gaussian Beam Propagation Code 10x
Entry  Thu May 18 12:46:08 2017, awade, Laser, WOPO, Initial testing Innolight Diabolo SHGLenthScan_TransmissionAndPZTSig.pdf
    Reply  Sun May 21 21:11:43 2017, awade, Laser, WOPO, Initial testing Innolight Diabolo 
    Reply  Thu May 25 16:28:21 2017, Dhruva, Laser, WOPO, Initial testing Innolight Diabolo Diabolo_for_WOPO.pdf
       Reply  Fri Jun 2 15:16:00 2017, Dhruva, Laser, WOPO, Initial testing Innolight Diabolo Diabolo.pdf
Entry  Wed Jun 7 15:19:30 2017, Aidan, Electronics, Cameras, Two micron camera light-saber test of Pembroke Widy camera IMG_9850.JPGScreen_Shot_2017-06-07_at_3.06.37_PM.pngWidy_Data.mat
    Reply  Wed Jun 7 15:30:46 2017, Aidan, Electronics, Cameras, Two micron camera light-saber test of Pembroke Widy camera Screen_Shot_2017-06-07_at_3.29.10_PM.png
Entry  Fri Jun 9 16:58:35 2017, Dhruva, Update, WOPO, WOPO Experiment Stuff ATF_WOPO_inventory.pdf
Entry  Fri May 26 18:29:59 2017, Dhruva, Laser, WOPO, Beam Profiling of Diabolo's 1064nm laser 1064_WOPO_1.jpg1064_WOPO_2.jpg1064_profile.pdf
    Reply  Mon Jun 12 17:18:19 2017, Dhruva, Laser, WOPO, Beam Profiling of Diabolo's 532nm laser profile.pdf
       Reply  Tue Jun 13 16:45:38 2017, Dhruva, Laser, WOPO, Diabolo Profiling 532_profile.pdf1064_profile.pdf
Entry  Fri Jun 16 18:55:40 2017, Dhruva, Update, WOPO, Mode Matching the 1064nm Beam into fibre 3_lens_solution.pdf1064_f1_profile.pdf1064_f2_profile.pdfMode_Matching_Lenses.jpg
Entry  Thu Jun 22 16:45:17 2017, Dhruva, Laser, WOPO, AdvR Waveguide Spec Sheet 
Entry  Mon Jun 26 10:55:02 2017, Dhruva, Update, WOPO, Temperature Control of the PPKTP Waveguide 10x
Entry  Tue Jun 27 11:34:00 2017, Dhruva, Update, WOPO, Mode Matching Woes - Fibre issues image2.JPGimage4.JPG
    Reply  Thu Jun 29 22:42:28 2017, awade, Update, WOPO, Mode Matching Woes - Fibre issues 
       Reply  Fri Jun 30 12:17:07 2017, Koji, Update, WOPO, Mode Matching Woes - Fibre issues 
          Reply  Sun Jul 2 19:47:35 2017, awade, Update, WOPO, Mode Matching Woes - Fibre issues 
             Reply  Sun Jul 2 21:21:39 2017, Koji, Update, WOPO, Mode Matching Woes - Fibre issues 
Entry  Wed Jun 28 13:24:35 2017, awade, Update, WOPO, PDs for homodyne detector 2017-06-28_13.21.32.jpg2017-06-28_13.17.32.jpg2017-06-28_13.17.00.jpg2017-06-28_13.16.51.jpg
    Reply  Wed Jun 28 20:05:02 2017, Koji, Update, WOPO, PDs for homodyne detector 
       Reply  Wed Jul 5 16:44:34 2017, Koji, Update, WOPO, PDs for homodyne detector 
Entry  Thu Jul 6 15:03:07 2017, Dhruva, Update, WOPO, Homodyne Design Homodyne.pdf
Entry  Mon Jul 10 12:12:26 2017, Dhruva, Update, WOPO, Efficient Fibre Coupling and Phase Matching Plot Phase_Matching.pdfGreen_Loss_1.jpgGreen_Loss_2.jpg
Entry  Mon Jul 10 12:05:49 2017, Amani G, DailyProgress, Scatterometer, Initial Build and Some Measurements IMG_1854.JPGprototype.jpgIMG_1762.JPGIMG_1862.JPG
    Reply  Tue Jul 11 12:21:00 2017, awade, DailyProgress, Scatterometer, Initial Build and Some Measurements 
Entry  Tue Jul 11 12:25:29 2017, awade, Howto, General, A Note On Plotting 
Entry  Mon Jul 17 19:27:27 2017, awade, Misc, General, Ants in the lab 
    Reply  Mon Jul 17 19:36:59 2017, Koji, Misc, General, Ants in the lab 
Entry  Mon Jul 17 22:19:36 2017, Dhruva, Summary, WOPO, Last Week in WOPO 532_MM.pdf532_f1.pdf532_f2.pdfsm1064att.pdfsm1064out.pdf
Entry  Tue Jul 18 22:09:14 2017, Dhruva, Update, WOPO, Photodetector Dark Noise 20170714-pda55noise.pdf
    Reply  Thu Jul 20 18:16:33 2017, rana, Update, WOPO, Photodetector Dark Noise 
Entry  Fri Jul 21 09:52:57 2017, Amani Garvin, DailyProgress, Scatterometer, Set Up Changes  
Entry  Sat Jul 22 14:25:55 2017, Dhruva, Update, WOPO, Table Noise Issues  20170721-_table_noise.pdf20170721_Circuit_in_Air.jpg20170721_Circuit_on_Table.jpg
    Reply  Sat Jul 22 14:41:07 2017, Dhruva, Update, WOPO, Photodetector Dark Noise 20170721-dark_noise.pdf
Entry  Sat Jul 22 14:43:16 2017, Dhruva, Update, WOPO, Subtractor Circuit Noise 20170721-subnoise.pdf
Entry  Mon Jul 24 11:31:41 2017, Amani Garvin, DailyProgress, Scatterometer, First Image, Need to Clean Things Up laser1.pngdark1.pngsubtracted_image.png
    Reply  Tue Jul 25 10:54:46 2017, Amani Garvin, DailyProgress, Scatterometer, First Image, Need to Clean Things Up 
       Reply  Wed Jul 26 09:48:12 2017, Amani Garvin, DailyProgress, Scatterometer, First Image, Need to Clean Things Up subtracted_image.png
Entry  Mon Jul 24 22:28:51 2017, rana, Misc, General, ELOG word wrap 
    Reply  Fri Jul 28 11:16:58 2017, rana, Misc, General, ELOG word wrap 
Entry  Thu Jul 27 11:41:45 2017, Amani Garvin, DailyProgress, Scatterometer, Calibrating the Camera 
    Reply  Wed Aug 2 14:50:03 2017, Amani Garvin, DailyProgress, Scatterometer, Calibrating the Camera measured_ideal_lambertian_scatter.png
       Reply  Mon Aug 7 15:09:35 2017, rana, DailyProgress, Scatterometer, Calibrating the Camera 
       Reply  Tue Aug 8 11:09:04 2017, Amani Garvin, DailyProgress, Scatterometer, Calibrating the Camera calibration_arb.pngcalibration_brdf.png
          Reply  Tue Aug 8 11:12:27 2017, Amani Garvin, DailyProgress, Scatterometer, Calibrating the Camera bkgsub_beam.png
Entry  Tue Aug 8 16:27:29 2017, Amani Garvin, DailyProgress, Scatterometer, What Was Though to be the Laser Is Actually Backscatter image_56.pngimage_14.pngbeam_0_7.png
Entry  Wed Aug 9 17:07:51 2017, Chris, Misc, Scatterometer, On silicon scattering and defects fig52.png
Entry  Thu Aug 10 18:32:51 2017, Amani Garvin, DailyProgress, Scatterometer, Images of Beam through Silicon zipped_images_of_beam_through_silicon.zip
    Reply  Mon Aug 14 00:10:37 2017, Amani Garvin, DailyProgress, Scatterometer, Images of Beam through Silicon highest_exposure.pnghdr_aug13.png
       Reply  Mon Aug 14 09:22:09 2017, Amani Garvin, DailyProgress, Scatterometer, Images of Beam through Silicon 200ms_exposure_subtracted.pnghdrim_subtractedimages.png
Entry  Mon Aug 14 12:29:54 2017, Amani Garvin, DailyProgress, Scatterometer, Image of Scatter in Silicon Sample beam_aug14_0.pngbeam_aug14_1.pngbeam_aug14_2.png
    Reply  Mon Aug 14 16:56:54 2017, Amani Garvin, DailyProgress, Scatterometer, Image of Scatter in Silicon Sample 6x
    Reply  Tue Aug 15 16:40:46 2017, Amani Garvin, DailyProgress, Scatterometer, Image of Scatter in Silicon Sample IMG_2158.JPG
Entry  Tue Aug 15 20:34:40 2017, Amani Garvin, DailyProgress, Scatterometer, Back of the Envelope Calculation Screen_Shot_2017-08-15_at_20.20.51.png
Entry  Wed Aug 16 10:16:25 2017, Amani Garvin, DailyProgress, Scatterometer, Varying the Distance Between Camera and Silicon 10x
Entry  Wed Aug 16 19:04:47 2017, Amani Garvin, DailyProgress, Scatterometer, Image of Beam in Silicon 200ms_Beam_Through_Sample.tify_norm_axis_counts.pngx_axis_counts.pngLASERBEAM_calibrated.tif
Entry  Tue Aug 22 11:59:56 2017, awade, Safety, General, Leak in the ATF Lab 2017-08-22_11.58.43.jpg
    Reply  Thu Aug 24 13:47:00 2017, Aidan, Safety, General, Leak in the ATF Lab IMG_0673_(1).jpgIMG_0674_(1).jpgIMG_0675_(1).jpgIMG_0676_(1).jpg
Entry  Sun Aug 27 21:55:14 2017, awade, Computing, Computing, Mapping the ATF/PSL/TCS lab 
    Reply  Mon Aug 28 17:11:47 2017, awade, Computing, Computing, Mapping the ATF/PSL/TCS lab 
Entry  Tue Aug 29 20:59:11 2017, awade, Jon, Lab Infrastructure, Computing, Setting up a gateway PC 
Entry  Wed Aug 30 21:22:20 2017, awade, Lab Infrastructure, CDS, Reboot fb1 
Entry  Wed Sep 6 11:50:12 2017, Jon, Lab Infrastructure, Computing, Gateway PC set up 
Entry  Wed Sep 6 11:51:40 2017, Jon, Lab Infrastructure, Computing, Gateway PC set up 
Entry  Fri Sep 15 14:12:38 2017, Aidan, Lab Infrastructure, General, QIL (ATF) Lab preparation for the plumbing work 13x
Entry  Mon Sep 18 19:29:24 2017, awade, Computing, General, Internet access down 
    Reply  Mon Sep 18 20:46:43 2017, awade, Computing, General, Internet access down 
Entry  Mon May 22 17:08:33 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
    Reply  Mon May 22 23:40:42 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
    Reply  Thu Sep 21 12:03:27 2017, awade, Electronics, Scatterometer, Hooking up Newport 6000 to emcore laser diode 
Entry  Thu Sep 21 12:25:05 2017, awade, Computing, Computing, Rebuild ws1 in ATF 
Entry  Wed Sep 27 12:41:57 2017, Jon Richardson, Lab Infrastructure, Computing, TCS Subnet Back Up 
Entry  Sun Nov 5 15:12:06 2017, rana, Summary, Computing, diaggui on Mac laptops 
Entry  Sun Dec 10 04:48:59 2017, rana, Computing, General, dokuwiki updated 
Entry  Fri Nov 10 20:23:48 2017, awade, Computing, , Reset top level router 
    Reply  Sun Dec 10 15:12:22 2017, awade, Computing, , Reset top level router 
Entry  Wed Jan 3 20:20:07 2018, awade, DailyProgress, WOPO, Reboot WOPO 
    Reply  Wed Jan 10 17:03:55 2018, awade, DailyProgress, WOPO, WOPO some shot noise numbers 
Entry  Fri Jan 27 13:36:04 2017, Aidan, Lab Infrastructure, PEM, Got old PEM sensors running with Windows 7 OPC server 
    Reply  Sat Feb 3 17:21:28 2018, awade, Lab Infrastructure, PEM, Modified Newport Sensors to use USB power in instead of AAs IMG_2261.JPGIMG_2263.JPGIMG_2264.JPG
Entry  Mon Feb 5 15:12:06 2018, Aidan, Computing, General, Major error with FB4 clock 
Entry  Fri Feb 9 15:20:59 2018, Aidan, Electronics, Cameras, Heimann Sensor thermopile array qualitative test 10x
Entry  Thu Feb 15 16:58:31 2018, Eric, Misc, General, Plan for LabJack U3-HV 20KHz.png20Hz-10KHz.pngLabJack_diagram.JPG
Entry  Thu Feb 22 12:09:20 2018, Jon Richardson, Computing, General, Reset Gateway Router 
    Reply  Thu Feb 22 12:13:27 2018, awade, Computing, General, Reset Gateway Router 
Entry  Thu Mar 8 13:23:57 2018, Craig, awade, Computing, General, gateway Linksys router was wiped via factory-reset, awade saves the day LinksysSetupBasicSetup.pngLinksysSetupApplicationAndGamingPortRangeForwarding.png
Entry  Mon Apr 23 12:44:07 2018, Jon Richardson, Computing, General, Added TCS/AWC Lab Port Forwards back to Linksys Router TCS-AWC_port_fwd.jpg
Entry  Sat May 5 06:08:35 2018, Eric, Update, , LabJack U3 New Setup Figure1.JPGFigure2.JPG
Entry  Wed Jan 17 10:41:45 2018, awade, Summary, WOPO, Making a transformer coupled photodiodes BasicSchematic_TranCoupledPD.pdf
    Reply  Wed May 23 20:38:10 2018, rana, Summary, WOPO, Transformer coupled photodiodes 
Entry  Sun May 27 16:10:27 2018, awade, Computing, Computing, Accessing 3com switch from screen on mac 
Entry  Tue May 29 16:12:48 2018, awade, Lab Infrastructure, Computing, Upgraded top level QIL/PSL/TCS lab's router IMG_3440.JPG
Entry  Tue Jun 5 13:59:43 2018, Eric, Summary, , LabJack Summary 9x
Entry  Tue Jun 26 17:35:33 2018, John Martyn, DailyProgress, Homodyne, First Week Progress 
Entry  Tue Jun 19 14:38:23 2018, Aidan, Electronics, TMTF, Ordered clamp plates to mount TECs to fiber for low-bandwidth control TOP_clamp_fiber_TEC.pdfBASE_clamp_fiber_TEC.pdf
    Reply  Thu Jun 28 16:59:17 2018, Aidan, Electronics, TMTF, Ordered clamp plates to mount TECs to fiber for low-bandwidth control IMG_4256.jpgIMG_4257.jpgIMG_4254.jpg
Entry  Mon Jul 2 11:23:06 2018, John Martyn, DailyProgress, Homodyne, BHD Optical Setup 
Entry  Fri Jul 6 22:30:20 2018, John Martyn, DailyProgress, Homodyne, Beam Profiling VoltageFit1.pngwFit.png
Entry  Wed Jul 11 16:30:40 2018, Vinny W., Summary, 2micronLasers, Acoustic and Thermal Sensitivity 
Entry  Sat Jul 21 01:45:00 2018, Vinny W., DailyProgress, 2micronLasers, The Gentle Sway of the EP2004 p_aafo_i.png20180720_181301.jpg20180720_174216.jpg
    Reply  Sat Jul 21 13:32:07 2018, awade, DailyProgress, 2micronLasers, The Gentle Sway of the EP2004 
Entry  Mon Jul 16 22:56:06 2018, John Martyn, DailyProgress, Homodyne, Transimpedance Amplifier Design SallenKeyPD2.pdf
    Reply  Sat Jul 21 14:28:34 2018, awade, DailyProgress, M2 ISS, Progress 7/17/18 
Entry  Sun Jul 22 11:47:02 2018, John Martyn, DailyProgress, Homodyne, Progress 7/22/18 TIANoise.pngTIATransferFunction.pngSallenKeyPD4.pdf
    Reply  Sun Jul 22 20:12:23 2018, awade, DailyProgress, , Progress 7/22/18 
Entry  Thu Jul 26 17:49:28 2018, Vinny W., DailyProgress, 2micronLasers, Power Loss through different optic components poweranalysis.JPG
Entry  Wed Jul 25 19:21:19 2018, John Martyn, DailyProgress, Homodyne, Transimpedance Amplifier and Photodiode Characterization TIA_Noise.pdfTIA_Transfer_Function.pdfNoise_and_Transfer_Function_Measurements.zipTIAPic.PNGTransImpAmpCircuit2.pdf
    Reply  Fri Jul 27 12:26:58 2018, John Martyn, DailyProgress, , Progress 7/25/18 
Entry  Fri Jul 27 15:50:16 2018, Aidan, Computing, TempCtrl, FB4 has stopped recording second trends 
Entry  Thu Jul 19 11:50:11 2018, Vinny W., DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA TIAcircuit.JPGTIAnoiseanalysis.JPG
    Reply  Sat Jul 21 14:17:20 2018, awade, DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA notebook_pyliso_WOPO1mmTransImp-v3.ipynb.zip
    Reply  Thu Aug 2 18:06:54 2018, awade, DailyProgress, 2micronLasers, The case of the DET10D Photodiode, featuring TIA 
Entry  Thu Aug 2 18:14:36 2018, John Martyn, DailyProgress, Homodyne, Outreach IFO Photodetector image3.pdfimage2.pdfimage1.pdfOutreachPDCircuit3.pdf
Entry  Fri Aug 10 21:55:52 2018, John Martyn, DailyProgress, Homodyne, BHD Electronics BHD_TF2.pdf
    Reply  Mon Aug 13 19:15:47 2018, awade, John Martyn, DailyProgress, Homodyne, BHD Electronics, digitizing 
Entry  Tue Aug 14 10:14:11 2018, John Martyn, DailyProgress, Homodyne, BHD Circuits and Set Up BHDPictures.pngBHD_TF3.pdfBHD_Noise.pdfBHDCircuit1.pdf
Entry  Tue Aug 14 13:44:47 2018, Vinny W., DailyProgress, 2micronLasers, Noise Analyses 
Entry  Wed Aug 22 14:13:18 2018, Rahul, Lab Infrastructure, , Cryo-vacuum chamber layout cryo_vacuum_schematic.jpg
Entry  Wed Aug 29 17:43:05 2018, John Martyn, DailyProgress, Homodyne, An Elusive Short Circuit and a Functional BHD 6x
Entry  Thu Aug 30 18:13:28 2018, awade, Howto, General, Running Acromag IOC epics servers out of docker modbus__defaults.zipDockerfile
Entry  Mon Aug 6 03:45:37 2018, Vinny W., DailyProgress, 2micronLasers, Thermal Sensor Circuit Update scheme_voltageref.JPGscheme_thermalsensor.JPG20180806_162441.jpg20180806_135423.jpg
    Reply  Tue Aug 7 10:47:43 2018, awade, DailyProgress, 2micronLasers, Thermal Sensor Circuit Update LISOModel_Sallen-Key.ipynb.zip
       Reply  Thu Sep 6 10:19:54 2018, awade, DailyProgress, 2micronLasers, Thermal Sensor Circuit: Modifications 8x
Entry  Fri Sep 7 23:12:51 2018, awade, Misc, Lab Monitoring, Temperature logging started in ATF lab 
    Reply  Sat Sep 8 17:14:37 2018, awade, Misc, Lab Monitoring, Temperature logging: activity in lab 
    Reply  Thu Oct 11 20:29:00 2018, awade, Misc, Lab Monitoring, Temperature logging started in ATF lab 20181011_ATFLabTemp_Sep9toOct11_AbsUncal_HourTrend.pdfMinuteTrend_Sep_atfLabTempData.txt
Entry  Fri Oct 12 19:05:51 2018, awade, DailyProgress, WOPO, Gluing 532 nm PZT mirror 
Entry  Mon Oct 22 09:46:10 2018, Rahul, Lab Infrastructure, , Cryo vacuum chamber setup lab.jpegGuages_and_controller.jpgCrane.jpgpumping_station.jpg
Entry  Mon Oct 29 19:05:58 2018, awade, DailyProgress, WOPO, Fixing MM into 532nm collimator 18-10-29_19-05-15_4347.jpg
Entry  Tue Oct 30 10:17:44 2018, Rahul, Update, , SHI Cryocooler cryocooler.jpgcompressor.jpgsupply_hose.jpgCold_test_report_SHI.jpg
Entry  Fri Nov 2 08:59:26 2018, Rahul, Update, , Vacuum chamber IMG_0005.jpgIMG_0008.jpgIMG_0007.jpg
Entry  Fri Nov 9 14:57:54 2018, Rahul, Update, , Cryo-vacuum chamber Picture1.jpg
Entry  Wed Nov 14 16:49:47 2018, Rahul, Update, Cryo vacuum chamber, assembly Bottom_plate.jpgtop_plate.jpg
Entry  Wed Nov 28 12:14:35 2018, awade, DailyProgress, WOPO, Mode field diameter choosing best patch for WOPO input 
Entry  Fri Jun 29 09:18:32 2018, Vinny W., DailyProgress, 2micronLasers, Power Loss in Fiber Optic Cable 7x
    Reply  Fri Jun 29 17:33:44 2018, rana, DailyProgress, 2micronLasers, Power Loss in Fiber Optic Cable 
    Reply  Wed Nov 28 17:14:11 2018, awade, Summary, TMTF, Notes on optimal length mismatch for fiber delay line MZ 2umMissmatchWorkings_v1.pdf2umMissmatchWorkings_v1.nb.zip
Entry  Thu Nov 29 16:52:50 2018, Rahul, Summary, , Cryo-vacuum chamber bottom_plate_on_spacer.jpgCrane_dovetail.jpg
Entry  Thu Nov 29 17:00:37 2018, Rahul, Misc, , Nor-Cal: leak rate of the chamber (collar) 
Entry  Tue Dec 4 15:56:29 2018, Rahul, DailyProgress, Cryo vacuum chamber, O-ring which fits IMG_0170.jpgIMG_0171.jpg
Entry  Wed Dec 5 16:18:50 2018, Rahul, DailyProgress, Cryo vacuum chamber, bottom plate 
Entry  Wed Dec 5 16:49:50 2018, Rahul, DailyProgress, Cryo vacuum chamber, Schematic for the flanges Schematic_chamber.jpg
Entry  Thu Dec 6 12:44:18 2018, Rahul, DailyProgress, Cryo vacuum chamber, Fabricated parts arrived Fabricated_Cold_plate.jpg
Entry  Thu Dec 6 16:49:40 2018, Rahul, DailyProgress, Cryo vacuum chamber, Chamber and bottom plate assembly O-ring_bottom.jpgBottom_collar_assembly.jpg
Entry  Fri Dec 7 11:59:29 2018, awade, Lab Infrastructure, General, Cardboard and packaging in the lab 
    Reply  Fri Dec 7 14:43:20 2018, Rahul, Lab Infrastructure, General, Cardboard and packaging in the lab 
Entry  Fri Dec 7 16:08:45 2018, Rahul, DailyProgress, Cryo vacuum chamber, Radiation shields  shields_1.jpgshield_2.jpgshields_bottom.jpg
Entry  Tue Dec 11 16:26:07 2018, Rahul, DailyProgress, Cryo vacuum chamber, cleaning of shields and cold plate 
Entry  Wed Dec 12 14:40:17 2018, Rahul, DailyProgress, Cryo vacuum chamber, cleaning of shields and cold plate IMG_0238.jpgIMG_0237.jpg
Entry  Mon Dec 17 13:52:58 2018, Aidan, Lab Infrastructure, Cleanliness, Oil spill on North table IMG_7827.jpgIMG_7828.jpg
Entry  Fri Dec 21 15:23:02 2018, Rahul, DailyProgress, Cryo vacuum chamber, Chamber closed for 1st pump down test Picture1.jpgPicture2.jpgPicture3.pngPicture4.jpg
Entry  Fri Dec 21 16:14:42 2018, Rahul, DailyProgress, Cryo vacuum chamber, Pump down results Pressure.jpgPLot1_pressure.png
Entry  Tue Dec 4 19:34:22 2018, awade, DailyProgress, WOPO, Diabolo 532 nm power drop and retuning 18-12-04_DiaboloInside_annotate.jpegplot20181204_DiaboloSHGRaligned1064nm.pdfplot20181204_DiaboloSHGRErrSig.pdf20181204_RetuneDiaboloSHGAlignment.zip
    Reply  Thu Dec 6 20:04:50 2018, awade, DailyProgress, WOPO, Diabolo 532 nm power drop and retuning 
       Reply  Fri Dec 7 20:31:06 2018, awade, DailyProgress, WOPO, Diabolo: cleaning dust out of SHG unit, self heating issues 18-12-07_20-06-46_4774.jpg18-12-07_20-06-58_4776.jpg18-12-07_20-07-44_4780.jpgIMG_4785.JPGIMG_4766.MOV
          Reply  Thu Dec 13 14:01:13 2018, awade, DailyProgress, WOPO, Diabolo: contacted coherent 
             Reply  Thu Dec 13 16:24:06 2018, awade, DailyProgress, WOPO, Diabolo: baseline numbers for coherent plot20181218_PhaseMatchingCurveFastScanDiaboloSHG.pdf20181213_SHGScanWithLNTempTuning.zip
                Reply  Wed Dec 19 16:48:18 2018, awade, DailyProgress, WOPO, Diabolo: baseline numbers for coherent 
                   Reply  Thu Dec 20 19:20:50 2018, awade, DailyProgress, WOPO, Diabolo: trialing SHG oven set temperature points to see if there is a maxima when locked plot20181220_SHGLockedOutputVsOvenSetpointTemperature.pdf20181220_SHGLockedPowerVsSetPointTemp.zip
                      Reply  Fri Dec 21 15:33:26 2018, Koji, DailyProgress, WOPO, Diabolo: trialing SHG oven set temperature points to see if there is a maxima when locked 
                         Reply  Fri Dec 21 15:51:27 2018, awade, DailyProgress, WOPO, Diabolo: trialing SHG oven set temperature points to see if there is a maxima when locked 
                      Reply  Mon Dec 24 10:08:49 2018, awade, DailyProgress, WOPO, Diabolo: back to power with deliberate pre-misalignment 18-12-21_22-04-30_4812.jpg18-12-21_22-04-54_4813.jpg18-12-21_22-07-55_4814.jpg
                         Reply  Mon Dec 24 12:07:18 2018, Koji, DailyProgress, WOPO, Diabolo: back to power with deliberate pre-misalignment 
Entry  Mon Dec 24 16:46:41 2018, awade, DailyProgress, WOPO, MM into 532 nm patch fiber (to be hooked up to WOPO) IMG_4823.JPG
Entry  Wed Jan 2 18:51:53 2019, awade, DailyProgress, Homodyne, Tweek up fiber alignment and reboot of homodyne 
    Reply  Fri Jan 4 19:49:51 2019, awade, DailyProgress, Homodyne, Tweek up fiber alignment and reboot of homodyne 20190104_TopViewSQZHDSetup.jpg
       Reply  Mon Jan 7 19:27:10 2019, awade, DailyProgress, Homodyne, Fixing homodyne fringe visibility and estimating losses scan_19-01-08_20-07-14.pdf
Entry  Tue Jan 8 11:38:49 2019, awade, Lab Infrastructure, General, Roughing pump leaking oil on bake rig IMG_4863.JPGIMG_4862.JPG
Entry  Thu Feb 21 17:02:24 2019, awade, DailyProgress, WOPO, Mixing down homodyne output from 1 MHz IMG_5106.JPG
    Reply  Fri Feb 22 14:05:09 2019, awade, DailyProgress, WOPO, Mixing down homodyne: 5th order elliptic filter (100 kHz) 5thOrderEllipticFilter_Schematic.png19-02-22_13-48-59_5116.jpgElliptical5thOrder_MeasuredVsModel.pdf20190222_5thOrderEllipticFilter100kHz.zip
Entry  Mon Feb 25 20:42:32 2019, Koji, Summary, Scatterometer, Si Block stored in Cryo Lab P_20190221_115501.jpg
Entry  Fri Mar 8 17:05:52 2019, Anjali, Update, , Frequency stabilization of 2 micron source Homodyne_setup_2micron.png
Entry  Mon Mar 11 08:49:11 2019, Aidan, Chub, Computing, Cymacs, Building FB4 Cymacs IMG_8851.jpgIMG_8852.jpg
Entry  Tue Mar 12 16:58:50 2019, awade, Misc, WOPO, Todo list W11 
Entry  Wed Feb 20 10:38:46 2019, awade, DailyProgress, WOPO, Fixing 532 nm polarization linearity issues 
    Reply  Thu Feb 28 16:00:59 2019, awade, DailyProgress, WOPO, Pol launch into PM fiber 19-02-26_19-46-51_5122.jpgPMFiber.pdf19-02-28_17-52-41_5131.jpg
       Reply  Tue Mar 12 16:35:43 2019, awade, DailyProgress, WOPO, Pol launch into PM fiber 1064 nm 
          Reply  Wed Mar 13 12:44:41 2019, awade, anchal, DailyProgress, WOPO, Pol launch into PM fiber 1064 nm IMG_5149.JPG
Entry  Wed Mar 13 17:49:14 2019, awade, Summary, WOPO, Damage threshold estimates for optical fibers 
Entry  Wed Mar 20 15:57:55 2019, Anjali, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator High_pass_transfer_function.pdfShot_noise.pdfThermoconductive_noise_of_fiber_Glenn_parameter.pdfnoise_budget_combined_log_log.png
    Reply  Wed Mar 20 19:17:50 2019, rana, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator 
Entry  Thu Mar 21 00:49:35 2019, Anjali, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator 
Entry  Thu Mar 21 09:43:19 2019, Anjali, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator Noise_budget_with_low_pass_transfer_function.pdf
Entry  Fri Mar 22 10:00:30 2019, Anjali, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator Noise_budget_modified.pdf
Entry  Mon Mar 25 09:40:16 2019, Anjali, Noise Budget, 2micronLasers, Noise budget for the frequency discriminator Comparison_of_thermoconductive_noise_in_Hz_per_rtHz.pdfNoise_budget_with_thermomechanical_noise.pdf
Entry  Tue Mar 26 17:13:53 2019, Anjali, Update, 2micronLasers, Frequency stabilization of 2 micron source Homodyne_setup_for_2_micron.pdf
Entry  Thu Mar 28 18:16:59 2019, Jon, Update, Computing, Cymac assembly started 
    Reply  Mon Apr 1 11:03:24 2019, Jon, Update, Computing, Cymac assembly started 
Entry  Tue Apr 2 14:16:00 2019, Aidan, Lab Infrastructure, Lab Monitoring, HOBO MX100 temperature sensors/data loggers added to the optical tables 7x
    Reply  Wed Apr 3 12:51:55 2019, Aidan, Lab Infrastructure, Lab Monitoring, HOBO MX100 temperature sensors/data loggers added to the optical tables QIL_North_2019-04-03_12_46_44_-0700.csvQIL_South_2019-04-03_12_46_11_-0700.csvQILtemperature.png
       Reply  Mon Apr 8 14:02:06 2019, Aidan, Lab Infrastructure, Lab Monitoring, HOBO MX100 temperature sensors/data loggers added to the optical tables QIL_lab_temperature_6days.pdfQIL_South_2019-04-08_13_39_33_-0700.txtQIL_North_2019-04-08_13_39_16_-0700.txt
Entry  Thu Aug 2 15:01:21 2018, awade, DailyProgress, WOPO, Building a SN limited detector for WOPO experiment 6x
    Reply  Mon Aug 6 17:30:53 2018, awade, DailyProgress, WOPO, Too much RIN, making a balanced detector plot20180803_Single6p8kTIADect_NoiseSpectrum.pdfSch20180806_SumWtTrim_IMG_3631.JPG
       Reply  Thu Aug 9 16:51:43 2018, awade, DailyProgress, WOPO, Testing balanced detector 
          Reply  Mon Aug 20 12:11:45 2018, awade, DailyProgress, WOPO, Testing (freespace) balanced detector 18-08-17_22-59-08_3649.jpg
             Reply  Mon Aug 20 22:09:27 2018, awade, DailyProgress, WOPO, PZT broken no slow phase modulation on LO 
                Reply  Wed Aug 22 00:42:42 2018, awade, DailyProgress, WOPO, New PZT mounted mirror 18-08-22_22-28-27_3673.jpg18-08-22_22-32-51_3678.jpg18-08-22_22-34-17_3680.jpg18-08-23_12-02-38_3684.jpg18-08-23_12-02-48_3686.jpg
                   Reply  Thu Aug 23 12:49:17 2018, awade, DailyProgress, WOPO, New PZT mounted mirror mounted IMG_3690_ThePriestAndTheBeast.JPG
       Reply  Mon Aug 13 01:48:48 2018, rana, DailyProgress, WOPO, SR560 battery as a voltage supply 
          Reply  Wed Aug 15 09:57:56 2018, awade, DailyProgress, WOPO, SR560 battery as a voltage supply 
       Reply  Mon Aug 13 01:53:21 2018, rana, DailyProgress, WOPO, zero-span spec OR RF bandpass 
          Reply  Mon Aug 13 15:43:55 2018, Chris, DailyProgress, WOPO, zero-span spec OR RF bandpass 
          Reply  Mon Aug 20 12:08:17 2018, awade, DailyProgress, WOPO, zero-span spec OR RF bandpass 
    Reply  Wed Mar 27 20:37:38 2019, awade, DailyProgress, WOPO, Measuring TF Homodyne Photo Detector for WOPO experiment TFUnitAandB_BeforeMatchingOutImp.pdfTFUnitAandB_FixingDetectorAImp.pdfWOPO_HD_TranImpGain_UnitAandBandLISO.pdf
       Reply  Fri Mar 29 16:00:21 2019, awade, DailyProgress, WOPO, Remeasuring TF Homodyne Photo Detector B after switching out foil cap 
          Reply  Wed Apr 10 13:10:45 2019, awade, DailyProgress, WOPO, Rebuild of WOPO homodyne detectors using AD829 BasicSchematic_TranImpPD_AD829.pdf19-04-02_19-42-47_5777.jpg19-04-04_12-39-15_5797.jpgWOPO_HDPD_AD829_2kohmTranImpGain_UnitAandBandLISO.pdf20190405_TFHDPDs_AD829Design_LargeBoard.zip
Entry  Thu Apr 11 20:50:17 2019, rana, Howto, General, how to learn quickly 
Entry  Mon Apr 22 19:35:16 2019, anchal and awade, Summary, WOPO, Shot Noise Intercept Current measurement of Photodiodes IMG_5875.JPGWOPO_BHD_Photodiodes_SNInterceptAnalysis.pdf20190419_MeasuredInterceptCurve.zip
Entry  Wed Apr 10 12:17:34 2019, Anjali, Update, 2micronLasers, Intensity noise stabilization of 2 micron source 2_micron_setup.jpgLaser_chara_setup.pngLaser_characteristics.pdfAOM_chara_setup.pngAOM_characteristics.pdf
    Reply  Wed Apr 10 18:58:48 2019, rana, Update, 2micronLasers, Intensity noise stabilization of 2 micron source 
       Reply  Wed Apr 24 09:01:49 2019, Anjali, Update, 2micronLasers, Intensity noise stabilization of 2 micron source Intensity_stabilisation.png
Entry  Wed May 1 14:34:53 2019, awade, DailyProgress, WOPO, Output chain and demodulation of squeezing signal 
Entry  Sun May 5 15:17:33 2019, Anjali, Noise Budget, 2micronLasers, Frequency noise measurement of 2 micron source schmeatic_heterodyne.pngNoise_budget_modified.pdf
    Reply  Sun May 5 20:52:16 2019, rana, Noise Budget, 2micronLasers, Frequency noise measurement of 2 micron source 
Entry  Tue May 7 19:39:39 2019, Jon, Lab Infrastructure, Cymacs, User model set up on QIL cymac  IMG_3278.jpg
Entry  Fri May 10 13:54:28 2019, Jon, Lab Infrastructure, Cymacs, QIL cymac installed in rack, passes loopback testing IMG_3289.jpg
Entry  Fri May 10 16:22:45 2019, Anjali, Update, 2micronLasers, Characterization of RF driver and AOM .  6x
Entry  Sat May 11 15:47:37 2019, Jon, Lab Infrastructure, Cymacs, MEDM user interface set up on QIL cymac Screen_Shot_2019-05-11_at_3.21.07_PM.png
Entry  Wed May 15 19:24:52 2019, Jon, Lab Infrastructure, Cymacs, Permanent cymac hardware installed and tested IMG_3300.jpgIMG_3299.jpg
Entry  Tue Apr 30 19:52:14 2019, awade, Howto, WOPO, Configuring Zurich box server 
    Reply  Thu May 16 16:52:46 2019, awade, Howto, WOPO, Zurich box python access ZurichPythonAccess_MWE.zip
Entry  Wed May 15 20:08:01 2019, Anjali, Update, 2micronLasers, PLL loop for frequency noise measurement 7x
    Reply  Thu May 16 13:40:13 2019, anchal, Update, 2micronLasers, PLL loop for frequency noise measurement 
    Reply  Sun May 19 22:08:09 2019, Anjali, Update, 2micronLasers, PLL loop for frequency noise measurement setup_close_loop_transfer_function.pngActuation_slope_10kHzV_diff_gain.pdfgain_10_different_actuation_slope.pdfFM_noise_AFG_Actuation_30kHzV_diff_gain.pdfFM_noise_AFG_gain_10_different_actuation_slope.pdf
Entry  Mon May 20 02:23:14 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source using PLL FM_noise_measurement_setup.png2_micron_FM_noise.pdfOscilloscope.mp4SR_785.mp4
Entry  Sat May 18 22:25:30 2019, Anjali, Update, 2micronLasers, Characterization of new detector setup.pngbeat_note.pdfNoise_floor.pdf
    Reply  Thu May 23 02:53:19 2019, Anjali, Update, 2micronLasers, Characterization of new detector 
Entry  Thu May 23 03:00:24 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source using PLL Detector_output.pdfFM_noise_full_span.pdfFM_noise_short_span.pdfoscilloscope.mp4
Entry  Sun May 26 01:12:33 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source using PLL 8x
Entry  Wed May 29 08:16:47 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source using PLL oscilloscope_trace_s_100kHz.zip
Entry  Wed May 22 15:07:09 2019, awade, DailyProgress, WOPO, Demodulation and subtraction for homodyne detector with Zurich box IMG_6099.JPGSweep_DemodLPFValues.pdfSingleHDChannel_RelaxOscillations_CompairNoiseEaterONOFF.pdfDemodFreqSweep_median100Hzto1kHz_vsdemodFreq.pdfCompairSubtractedSignalToDarkNoise.pdf
    Reply  Thu May 23 15:29:58 2019, awade, DailyProgress, WOPO, Making time domain measurement of noise power in homoydne with WOPO pump on RMSFunctionTimeCompairingSNWithInjected532nmpump.pdf
       Reply  Sun May 26 21:24:38 2019, awade, DailyProgress, WOPO, Excess noise when pumping: checklist for Monday. 
          Reply  Wed May 29 15:24:33 2019, awade, DailyProgress, WOPO, Update to checklist 20190528_ProperIQReconstructionAndLPFilteringData.zip
Entry  Thu May 30 07:43:21 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source using PLL Oscilloscope.mp4Spectrum_analyser.mp4
Entry  Wed Jun 5 14:16:07 2019, Koji, Update, 2micronLasers, 2um laser / cryo stat: setup inspection and action item updates 
Entry  Wed Jun 12 15:15:58 2019, Aidan, Chris, Lab Infrastructure, Cleanliness,  IMG_0151.jpgIMG_0152.jpgIMG_0153.jpg
Entry  Sat Jun 1 09:46:00 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source 
    Reply  Fri Jun 7 16:32:59 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source Lock_in_amplifier_moku_lab.jpgFM_noise.pdf
       Reply  Thu Jun 13 22:53:25 2019, Anjali, Update, 2micronLasers, Frequency noise measurement of 2 micron source FM_noise_new_.pdfMokulab.m
Entry  Wed Dec 31 15:59:59 1969, Shubhabroto, DailyProgress, , Little PMC Assembly 7x
Entry  Tue Jun 18 00:43:17 2019, Duo, DailyProgress, Cryo vacuum chamber, Chamber Opening image1.jpegimage1.jpeg
Entry  Tue Jun 25 19:56:23 2019, rana, Electronics, Cleanliness, Moku Out 
Entry  Sat Jun 29 09:50:20 2019, Jon, Computing, CDS, Cymac workstation setup 
Entry  Wed Jun 26 11:45:09 2019, Koji, Summary, 2micronLasers, 2um PD transimpedance PD_model.pdfAMP2_Noise.pdfAMP_Noises.pdfPD_noise.pdfPD_TF.pdf
    Reply  Mon Jul 1 21:20:55 2019, Koji, Summary, 2micronLasers, The PDs delivered to the lab 
Entry  Wed Jul 10 17:37:09 2019, Jon, Computing, Cymacs, New QIL workstation IMG_3493.jpg
Entry  Mon Jul 15 19:02:21 2019, Jon, Computing, Cymacs, Cymac RTS Environment Set Up 
Entry  Mon Jul 22 18:11:59 2019, Jon, Computing, Cymacs, New Monitors for QIL Workstation  IMG_3523.jpg
Entry  Mon Jul 22 20:21:33 2019, Shalika, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyzer and Zero Simulation 7x
Entry  Mon Jul 22 20:36:35 2019, Koji, Electronics, 2micronLasers, Sockets for LaserComponents PDs IMG_8793.jpgIMG_8792.jpgIMG_8791.jpg
Entry  Tue Jul 23 21:02:14 2019, Shalika Singh, DailyProgress, 2micronLasers, Transfer Function using SR785 spectrum analyzer full_circuit.pdfTransfer_Function_of_Circuit.pdf
Entry  Wed Jul 24 18:50:27 2019, Shalika Singh, DailyProgress, 2micronLasers, Correction in Transfer Function using SR785 spectrum analyzer full_circuit.pdfTransfer_Fucntion.pdf
Entry  Thu Jul 25 11:15:40 2019, Nathan Holland, DailyProgress, 2micronLasers, Phase Noise of Moku. 8x
Entry  Mon Jul 29 14:46:09 2019, Nathan Holland, DailyProgress, 2micronLasers, Optical Phase noise of 2 um Mach Zehnder Interferometer. Optical_Phase_Noise_Spectra_2um_Mach_Zehnder__20190729.pdf20190729__Initial_Phase_Noise_Measurement_setup.pdfMeasured_phase_spectra_2um_Mach_Zehnder__20190729.pdf2um_Mach_Zehnder_data__20190729.hdf5
    Reply  Mon Jul 29 15:46:50 2019, Koji, Laser, 2micronLasers, Optical Phase noise of 2 um Mach Zehnder Interferometer. 
Entry  Mon Jul 29 17:52:33 2019, Shalika Singh, DailyProgress, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation full_circuit.pdfNoise_across_TIA.pdfNoise_across_Differential_Circuit.pdf
    Reply  Tue Jul 30 20:42:06 2019, rana, DailyProgress, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 
Entry  Thu Aug 1 11:25:27 2019, Shalika Singh, DailyProgress, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation Circuit.pdffull_circuit.pdfSR785_display_screen.pdfNoise_across_TIA.pdf
    Reply  Thu Aug 1 13:01:15 2019, rana, DailyProgress, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 
Entry  Fri Aug 2 16:15:01 2019, Nathan Holland, DailyProgress, 2micronLasers, Frequency Noise Measured by 2um Mach Zehnder. Measured_Mach_Zehnder_frequency_noise_SmoothMedian__20190805.pdfMeasured_phase_spectra_2um_Mach_Zehnder_BB_SmoothMedian__20190805.pdf2um_MachZehnder_frequency_noise__20190805.hdf5
Entry  Thu Aug 8 17:19:12 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of TIA using SR785 Spectrum Analyser and Zero Simulation TIA.pdfNoise_across_TIA.pdfNoise_across_TIA.pdfpowersupply.pdf
Entry  Fri Aug 9 21:10:48 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 6x
Entry  Sun Aug 11 01:22:04 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of voltage regulator using SR785 Spectrum Analyser regulator.pdfNoise_across_Voltage_Regulator_Circuit.pdf
    Reply  Sun Aug 11 14:35:41 2019, Koji, Noise Budget, 2micronLasers, Noise Analysis of voltage regulator using SR785 Spectrum Analyser 
       Reply  Sun Aug 11 19:15:32 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of voltage regulator using SR785 Spectrum Analyser 
          Reply  Sun Aug 11 22:34:50 2019, Koji, Noise Budget, 2micronLasers, Noise Analysis of voltage regulator using SR785 Spectrum Analyser 
Entry  Mon Aug 12 11:37:36 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 7x
Entry  Mon Aug 12 12:09:00 2019, Nathan Holland, Summary, 2micronLasers, Adjusting the Voltage/Frequency Offset on the Brimrose AOM Driver. 2um_MachZehnder_wide_PowerSpectrum_Screenshot.png2um_MachZehnder_narrow_PowerSpectrum_Screenshot.png2um_MachZehnder_wide_PowerSpectrum_adjusted_Screenshot.png2um_MachZehnder_narrow_PowerSpectrum_adjusted_Screenshot.png
Entry  Mon Aug 12 11:51:38 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator using SR785 Spectrum Analyser regulator.pdfNoise_across_Voltage_Regulator_Circuit.pdf
    Reply  Mon Aug 12 15:17:05 2019, Koji, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator using SR785 Spectrum Analyser 
Entry  Tue Aug 13 16:53:57 2019, Nathan Holland, Electronics, 2micronLasers, Phase Noise of Brimrose AOM Driver (VCO). 20190813__Brimrose_AOM_Driver_phase_noise.pdf20190813__VCO_phase_noise_setup.pdfbrimrose_AOM_driver_VCO_phase_noise_spectra.hdf5
Entry  Tue Aug 13 17:59:25 2019, Nathan Holland, Noise Budget, 2micronLasers, Phase Noise of Mach Zehnder with VCO. 20190813__Phase_Noise_Measurement_VCO_setup.pdfMachZehnder_w_AOM_Driver_085_20190813_102449.li20190813__MachZehnder_w_VCO-phase_noise.pdf20190813__MachZehnder_w_VCO-frequency_noise.pdf
Entry  Tue Aug 13 19:14:04 2019, Jon, Computing, Cymacs, NFS server set up IMG_3587.jpg
Entry  Wed Aug 14 16:07:57 2019, Nathan Holland, DailyProgress, 2micronLasers, New AOM Driver. 20190814__Phase_Noise_Setup.pdfMachZehnder_measured_phase_noise-LO_path__20190814.pdfMachZehnder_measured_phase-IFO_path__20190814.pdfMachZehnder_measured_phase-IFO_path_zoom__20190814.pdf
Entry  Wed Aug 14 19:50:37 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise analysis of Sallen Key filter using SR785 and Zero simulation sallenkeyfilter.pdfTransfer_function_of_sallen_key.pdfNoise_across_SallenKey.pdfsallenkey.zip
Entry  Thu Aug 15 15:45:30 2019, Duo, Lab Infrastructure, , Floor plan around the big cryostat autodraw_8_15_2019.png
Entry  Thu Aug 15 02:30:29 2019, Koji, Summary, 2micronLasers, InAsSb PDs accomodated in PD housings / PD cables 9x
    Reply  Fri Aug 16 01:28:28 2019, Koji, Summary, 2micronLasers, Switchable breakout bok P_20190815_210355.jpgP_20190815_210419.jpg
Entry  Sun Aug 18 14:16:59 2019, Duo, Summary, , Measuring the dark current of PD exp.pdfIMG_2921.png
Entry  Mon Aug 19 13:57:02 2019, Shalika, Noise Budget, PD noise, Dark noise of Sb3513_A2 6x
Entry  Fri Aug 23 12:45:08 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation sallenkeyfilter.pdfbodeplot_sallenkey.pdfNoise_across_SallenKey.pdfsallen.zip
    Reply  Fri Aug 23 14:15:58 2019, Duo, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 
       Reply  Fri Aug 23 17:35:37 2019, Koji, Noise Budget, 2micronLasers, Noise Analysis of Circuit using SR785 Spectrum Analyser and Zero Simulation 
Entry  Mon Aug 26 10:45:43 2019, Shalika Singh, Noise Budget, PD noise, 1/f noise analysis and dark current density Dark_current_density.pdf1_fnoise.pdfJPL_Sb35313_A2.zip
Entry  Wed Aug 28 21:25:20 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Bump observed at 8kHz during TIA noise analysis circuit.jpgcircuit_setup.jpgNoise_across_TIA_op27.pdfNoise_across_TIA_LT1792.pdfTIA.zip
    Reply  Thu Aug 29 15:36:49 2019, Koji, Noise Budget, 2micronLasers, Noise Bump observed at 8kHz during TIA noise analysis 
Entry  Tue Aug 13 19:03:05 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer regulator.pdfNoise_across_Voltage_Regulator.pdfregulator.zip
    Reply  Thu Aug 15 08:03:13 2019, rana, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
       Reply  Thu Aug 15 08:36:29 2019, Shalika, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
    Reply  Fri Aug 30 05:11:11 2019, Chris, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
Entry  Tue Sep 3 16:47:08 2019, Duo, Lab Infrastructure, , QIL lab floor plan qilfloor.pdf
    Reply  Wed Sep 4 22:14:12 2019, rana, Lab Infrastructure, , QIL lab floor plan 
Entry  Thu Sep 5 11:10:08 2019, Shalika Singh, Noise Budget, TIA, Noise Analysis of transimpedance amplifier 7x
    Reply  Thu Sep 5 15:40:22 2019, rana, Noise Budget, PD noise, Noise Analysis of transimpedance amplifier 
Entry  Sun Sep 8 16:08:04 2019, rana, Electronics, General, Solder: what kind of solder to use and why? 
Entry  Tue Sep 10 17:17:11 2019, Shalika Singh, Noise Budget, PD noise, Dark Noise measurement of Extended InGaAs  8x
    Reply  Tue Sep 10 18:38:18 2019, Koji, Noise Budget, PD noise, Dark Noise measurement of Extended InGaAs  
Entry  Tue Sep 17 23:42:41 2019, Shalika Singh, Laser, PD QE, Measuring Quantum Efficiency of Extended InGaAs Photodiode IMG_8915.JPGQE_X8906.pdfExtended_InGaAs.zip
Entry  Fri Sep 20 17:31:25 2019, Duo, DailyProgress, General, General update 
Entry  Mon Sep 23 23:48:12 2019, Koji, Update, 2micronLasers, 2um sensor cards / focusing optics IMG_8936.jpg
Entry  Thu Sep 26 18:05:31 2019, Duo, Lab Infrastructure, , Cryo cooler and pump test run IMG_0990.jpg
Entry  Tue Oct 1 19:25:08 2019, Jon, Computing, Cymacs, IP address changes 
Entry  Wed Oct 9 17:40:57 2019, Raymond, Chris, Duo, DailyProgress, Cryo vacuum chamber, Closing the vacuum chamber 
Entry  Thu Oct 10 17:28:33 2019, Raymond, Chris, DailyProgress, Cryo vacuum chamber, Radiation shields unpacked 6x
Entry  Fri Oct 11 17:12:26 2019, Raymond, Chris, DailyProgress, Cryo vacuum chamber, Closing the vacuum chamber IMG_0204.JPG
    Reply  Fri Oct 11 17:33:47 2019, rana, DailyProgress, Cryo vacuum chamber, Closing the vacuum chamber 
Entry  Thu Oct 17 14:12:10 2019, Duo, Lab Infrastructure, , IOGEAR GWU637 failure 
Entry  Fri Oct 18 14:44:22 2019, Chris, Lab Infrastructure, Cryo vacuum chamber, 208V electrical service was installed in the QIL 
Entry  Mon Oct 21 17:07:17 2019, Chris, Lab Infrastructure, Cryo vacuum chamber, Cryo chamber vacuum pressure logging vac.png
Entry  Tue Oct 22 15:55:52 2019, Koji, Electronics, General, Borrowed ITC510 from Cryo 
Entry  Thu Oct 24 11:58:27 2019, Chris, Electronics, CDS, new QIL AA boards 
Entry  Tue Nov 5 20:06:36 2019, Raymond, Update, Cryo vacuum chamber, Cooler to tank connection CoolerCartoon.pdfScreen_Shot_2019-11-05_at_20.25.54.png
Entry  Wed Nov 6 17:05:33 2019, Raymond, DailyProgress, Cryo vacuum chamber, Conflat flange tightening 
Entry  Mon Nov 11 22:19:09 2019, Raymond, DailyProgress, Cryo vacuum chamber, Changes to preserve long strap for internal chamber use ShortAdapter.png
Entry  Thu Oct 31 18:31:10 2019, Koji, Laser, PD QE, PD EQE vs Spot size QE_vs_spotsize.pdf
    Reply  Fri Nov 1 12:47:18 2019, Koji, Laser, PD QE, PD EQE vs Spot size QE_vs_spotsize_no_saturation.pdfQE_vs_spotsize_saturation_0_85.pdfQE_vs_spotsize_saturation_0_1.pdf
       Reply  Tue Nov 12 03:40:39 2019, Koji, Laser, PD QE, PD EQE vs Spot size QE_vs_spotsize_half_power.pdf
Entry  Fri Nov 15 20:10:00 2019, Koji, Summary, 2micronLasers, InAsSb PD Mounts designed 
Entry  Mon Nov 18 17:17:29 2019, Duo, Summary, , Restart model in QIL lab 
Entry  Wed Nov 20 11:51:27 2019, Raymond, Misc, HVAC, Dueling vents 
Entry  Tue Nov 12 17:44:39 2019, Raymond, DailyProgress, Cryo vacuum chamber, Tank Update IMG_0258.JPGIMG_0257.JPGIMG_0259.JPG
    Reply  Thu Nov 21 21:58:27 2019, Raymond, DailyProgress, Cryo vacuum chamber, Tank Update IMG_0490.JPGIMG_0491.JPGDiaphragmAdapt.pdf
Entry  Mon Nov 25 15:03:34 2019, Koji, Update, PD QE, In solder and PD mounts are in  PB259778.JPGPB259780.JPGPB259781.JPG
Entry  Tue Nov 26 18:49:11 2019, Koji, Update, PD QE, Socket soldering test piece made 6x
    Reply  Tue Dec 3 13:52:04 2019, Koji, Update, PD QE, Socket soldering test piece made PC029784.jpegPC029788.jpegPC029786.jpegPC029787.jpeg
Entry  Mon Nov 25 21:46:56 2019, Koji, Summary, PD QE, System Diagram cryo_pd_test.pdfInAsSb_PD_mount_short.PDFPD_pin.pdf
    Reply  Wed Nov 27 20:38:57 2019, Koji, Summary, PD QE, System Diagram P_20191127_203612_vHDR_On.jpg
       Reply  Sun Dec 1 01:32:19 2019, Koji, Summary, PD QE, PD TEC cooling test 20191129191814_IMG_9146.JPGcooling_dark_current.pdf
          Reply  Tue Dec 3 15:32:39 2019, Koji, Summary, PD QE, PD TEC cooling test 
Entry  Fri Nov 15 17:29:14 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0270.JPGIMG_0269.JPG
    Reply  Tue Nov 19 20:16:40 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0483.JPG
       Reply  Wed Nov 20 11:59:17 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
          Reply  Wed Nov 20 12:25:58 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
             Reply  Wed Nov 20 17:44:10 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab P_20191120_174034_vHDR_On.jpgP_20191120_174040_vHDR_On.jpg
                Reply  Thu Nov 21 21:45:10 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab DT02H_18_32PN.pdf
                   Reply  Fri Nov 22 13:21:26 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0497.JPGIMG_0498.JPG
                      Reply  Fri Nov 22 15:33:40 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab P_20191122_150845_vHDR_On.jpg
                         Reply  Sat Nov 23 13:00:06 2019, Koji, Lab Infrastructure, Optics, Optical window transmission measurement optical_window_T.pdfP_20191122_183426_vHDR_On.jpgP_20191122_183436_vHDR_On.jpg
                         Reply  Tue Nov 26 15:36:59 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IRLabsQIL.jpg
                            Reply  Wed Dec 4 13:54:04 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
Entry  Mon Sep 23 10:49:27 2019, Koji, Summary, PD QE, QE and dark current of InAsSb sensors InAsSb_QE.pdfInAsSb_DarkCurrent.pdf190921_SbPD_QE.zip
    Reply  Wed Sep 25 01:05:30 2019, Koji, Summary, PD QE, QE and dark current of InAsSb sensors P_20190924_233507_vHDR_On.jpgP_20190925_003614_vHDR_On.jpgInAsSb_QE.pdfInAsSb_DarkCurrent.pdf
       Reply  Thu Dec 5 13:50:59 2019, Koji, Summary, PD QE, Dark current measurement with the sourcemeter InAsSb_DarkCurrent_markedup.pdf
Entry  Fri Dec 6 00:13:12 2019, Chris, Computing, CDS, arbitrary waveform streaming on the cymac 
Entry  Mon Dec 9 02:15:39 2019, Raymond, DailyProgress, PD QE, IR Labs Cryostat  IRLabscryointernals.pdf
    Reply  Mon Dec 9 12:34:14 2019, Koji, DailyProgress, PD QE,  
Entry  Mon Dec 9 14:03:52 2019, Chris, DailyProgress, PD QE, Toward PD testing automation 
    Reply  Mon Dec 9 14:45:45 2019, Koji, DailyProgress, PD QE, Toward PD testing automation 
Entry  Tue Dec 10 16:35:03 2019, Aidan, Laser, 2micronLasers, Calibrated cryo-PD REF PD output in units of power incident on cryo chamber window 
Entry  Wed Dec 11 01:29:26 2019, Koji, Summary, PD QE, Sb3513 A2P6 Dark Current / QE / Dark Noise measurement @77K Sb3513_A2P6_DarkCurrent_77K.pdfSb3513_A2P6_QE_77K.pdfSb3513_A2P6_DarkNoise_77K.pdf191210_3513A2P6.zip
Entry  Wed Dec 11 15:53:48 2019, Aidan, Chris, Raymond, Howto, Cryo vacuum chamber, Procedure to record photodiode output vs temperature 
    Reply  Wed Dec 11 19:50:25 2019, rana, Howto, Cryo vacuum chamber, Procedure to record photodiode output vs temperature 
Entry  Thu Dec 12 02:10:37 2019, Raymond, Chris, DailyProgress, PD QE, PD test dry run 
Entry  Fri Dec 13 01:51:15 2019, Raymond, DailyProgress, PD QE, Cryostat wiring fixes 18_32malepinsinairAssigned.pdf
    Reply  Mon Dec 16 18:16:31 2019, Raymond, DailyProgress, PD QE, Cryostat wiring fixes 
Entry  Fri Dec 20 13:20:53 2019, Aidan, Summary, PD QE, QE results from A2P6 (500um) and A2P2 (1mm) 6x
Entry  Fri Dec 20 21:58:14 2019, Koji, Update, PD QE, PD TEC driver / A2P6 aligned / Lens moved P_20191220_192440_vHDR_On.jpgP_20191220_180929_vHDR_On.jpg
    Reply  Fri Dec 20 22:26:19 2019, Koji, Update, PD QE, PD TEC driver / A2P6 aligned / Lens moved 6x
Entry  Wed Mar 27 11:27:00 2019, Aidan, Lab Infrastructure, HVAC, HVAC temperature gradients in the QIL 
    Reply  Wed Apr 24 14:19:55 2019, awade, Lab Infrastructure, HVAC, HVAC QIL: two actuators tied to one sensor now 
       Reply  Wed Apr 24 19:30:55 2019, rana, Lab Infrastructure, HVAC, howto get temperature trends QIL_temperature_190424.tgz
          Reply  Sun May 5 20:58:20 2019, rana, Lab Infrastructure, HVAC, howto get temperature trends HVAC-B265B.pdfplotTemp.tgz
             Reply  Fri May 10 18:39:10 2019, rana, Lab Infrastructure, HVAC, howto get temperature trends 
                Reply  Tue May 14 13:10:36 2019, rana, Lab Infrastructure, HVAC, HVAC debuggin HVAC-B265B.pdf
                Reply  Tue Feb 4 14:18:24 2020, Ian MacMillan, Lab Infrastructure, HVAC, Recent temperature fluctuations HVAC-B265B_20200402.pdfQil_Lab_Temperature.zipHVAC-B265B.pdf
                   Reply  Thu Feb 13 11:04:47 2020, Ian MacMillan, Lab Infrastructure, HVAC, Recent temperature fluctuations HVAC-B265B.pdfJan_2020_Qil_Temp_Measurments.zip
Entry  Thu Feb 27 14:26:52 2020, Koji, Summary, Lab Monitoring, Item lending: Particle Counter from OMC Lab to QIL P_20200227_134755_vHDR_On.jpg
    Reply  Fri Feb 28 13:36:32 2020, Ian MacMillan, Summary, Lab Monitoring, Item lending: Particle Counter from OMC Lab to QIL 
Entry  Mon Feb 24 18:41:06 2020, Raymond, Lab Infrastructure, HVAC, Table Shielding for 2020-02-25 HVAC repairs QIL_HVACshielding1_2020-02-24.JPGQIL_HVACshielding2_2020-02-24.JPGQIL_HVACshielding3_2020-02-24.JPGQIL_HVACshielding4_2020-02-24.JPG
    Reply  Tue Feb 25 15:12:22 2020, Raymond, Chris, Koji, Chub, Aidan, Lab Infrastructure, HVAC, HVAC work concluded for today 
       Reply  Mon Mar 9 13:13:02 2020, Koji, Lab Infrastructure, HVAC, HVAC work concluded for today 
Entry  Mon Apr 6 18:35:48 2020, Koji, Summary, General, West Bridge flooding Apr 6th image2.jpegimage1.jpeg
    Reply  Mon Apr 6 18:38:50 2020, Koji, Update, General, West Bridge flooding Apr 6th 15x
       Reply  Mon Apr 6 19:01:21 2020, Koji, Update, General, West Bridge flooding Apr 6th 20200406151420_IMG_9653.jpg20200406151428_IMG_9654.jpg20200406151459_IMG_9655.jpg20200406151633_IMG_9656.jpg20200406151709_IMG_9658.jpg
Entry  Fri May 1 13:27:07 2020, Raymond , Update, PD noise, Sb3513 A2P6 2020-02-04 Dark Noise/QE data 20200204_A2P6_77Kto295K.zip
Entry  Thu Apr 16 18:03:22 2020, aaron, Update, PSOMA, preliminary PSOMA layout PSOMA_layout.pdf
    Reply  Tue May 12 10:15:30 2020, aaron, Update, PSOMA, preliminary PSOMA layout whiteboard_configs.zipring_MZ_config.pdf
Entry  Fri Jul 17 15:54:42 2020, Stephen, Lab Infrastructure, Cryo vacuum chamber,  
    Reply  Fri Jul 24 04:46:51 2020, Stephen, Lab Infrastructure, Cryo vacuum chamber,  
Entry  Fri Jul 24 04:54:57 2020, Raymond, Lab Infrastructure, General, MDF repair MDFrepair_before.jpgMDFrepair_during.jpgMDFrepair_after.jpg
Entry  Fri Jul 24 05:22:30 2020, Raymond, Lab Infrastructure, PD QE, Round 2 of JPL PD's in lab JPL_PDs_2.jpg
Entry  Fri Jul 24 07:50:00 2020, Raymond, Update, Cryo vacuum chamber, Prototype shield panels MarinerShieldPrototype_parts.jpg
Entry  Tue Aug 4 17:08:00 2020, Raymond, Update, Cryo vacuum chamber, 19 pin MIL feedthrough and CTC100 wiring QIL_TempSensor_MIL19pinWiringDiagram.pdfexternal_tank_RTDs_1.pdfF6D69C6A-7168-4D06-B02A-E83CE8AFE524_1_105_c.jpeg
Entry  Fri Aug 7 11:50:06 2020, Raymond, Update, Cryo vacuum chamber, Tank pumpdown 6A57C6DF-0B58-413E-B9C0-797B14A10CCF_1_105_c.jpeg
Entry  Fri Aug 14 11:17:04 2020, Raymond, Update, Cryo vacuum chamber, Cooler now operational IMG-1190.JPGIMG-1187.JPGIMG-1189.JPG
Entry  Wed Sep 2 08:13:18 2020, Stephen, DailyProgress, Cryo vacuum chamber, Assembly of QIL Setup and other updates from 2020 Sep 01 photos_cit_qil_lab_cryo_shield_test_assembly_20200901.zipT2000538-v1_Part_3_Assembly_of_QIL_Test_Setup_20200901_end_result.jpgIMG_7582.JPG
Entry  Tue Sep 15 15:16:18 2020, Anchal, Misc, Cleanliness, HEPA Filters turned to maximum 
Entry  Wed Sep 23 00:26:59 2020, aaron, Misc, General, lab entry 
Entry  Fri Sep 25 14:45:04 2020, Stephen, DailyProgress, Cryo vacuum chamber, Vibration Measurement Equipment and Shield Construction 
Entry  Thu Oct 22 11:19:44 2020, anchal, Summary, ECDL, Prospects of using ECDL for Auxiliary laser AUX_Loop_Study_With_ECDL.pdf
    Reply  Fri Oct 23 12:19:19 2020, anchal, Summary, ECDL, Effects of chosen AUX finesse and source on Calibration requirements AUX_Finesse_and_Source_Study.pdf
       Reply  Wed Oct 28 14:05:19 2020, rana, Summary, ECDL, Effects of chosen AUX finesse and source on Calibration requirements 
Entry  Thu Nov 5 11:20:45 2020, anchal, Summary, ECDL, True PDH Error signal TF and including FSR effects in approximated models PDHErrorTFModel.pdfPDHTFforACavity.ipynb.zip
Entry  Fri Nov 6 08:14:58 2020, Aidan, Update, 2um Photodiodes, Photodiode testing recovery status 
    Reply  Fri Nov 6 12:45:21 2020, Aidan, Update, 2um Photodiodes, Photodiode testing recovery status MEDM.pngPD_sweep.png
Entry  Mon Nov 9 15:49:58 2020, Aidan, Update, 2um Photodiodes, JPL PD resurrection (cont.) 
    Reply  Tue Nov 10 12:46:34 2020, Aidan, Update, 2um Photodiodes, JPL PD resurrection (cont.) temperature_diff_shield_v_PD.png
Entry  Mon Nov 9 10:08:38 2020, anchal, Summary, ECDL, AUX wavelength finesee requirements in mariner with 1418 nm ECDL (Preliminary) AUX_Finesse_Study_With_ECDL.pdf
    Reply  Wed Nov 11 16:09:22 2020, anchal, Summary, ECDL, AUX wavelength finesee requirements in mariner - Added Excess Scatter Noise AUX_Finesse_Study_With_ECDL.pdf
Entry  Tue Nov 17 17:51:44 2020, Aidan, Update, 2um Photodiodes, Agilis piezo mirror installed in JPL PD testing apparatus  IMG_9401.jpgIMG_9400.jpg
    Reply  Thu Nov 19 16:25:30 2020, Aidan, Update, 2um Photodiodes, Agilis piezo mirror installed in JPL PD testing apparatus  Screen_Shot_2020-11-19_at_4.27.17_PM.png
Entry  Fri Nov 20 18:47:42 2020, Koji, Summary, General, Permenant exchange of TED200C(QIL) and TED200C(2umECDL) 
Entry  Tue Dec 8 11:27:51 2020, Radhika, Misc, Lab Monitoring, Particle counter communication 
Entry  Wed Dec 16 22:08:36 2020, anchal, Update, Equipment transfer, Took delay line box, compressed nitrogen cylinder and lens to 2um (Crackle) lab 
Entry  Fri Nov 20 18:49:43 2020, Koji, Summary, General, Instrument loan 
    Reply  Tue Dec 22 10:42:17 2020, rana, Summary, General, Instrument loan 
       Reply  Tue Dec 22 15:20:14 2020, Koji, Summary, General, Instrument loan 
          Reply  Tue Dec 29 17:53:21 2020, rana, Summary, General, Instrument loan 
Entry  Fri Jan 15 10:55:23 2021, Paco, Lab Infrastructure, General, Borrow AG4395A 
Entry  Mon Jan 25 16:05:43 2021, aaron, Misc, Equipment transfer, cantilever Qs to QIL 201A9C3E-1F44-4D03-B08F-F806B07011FA.jpeg17B5D21C-CF37-41D3-95D6-F5C85596D728.jpeg
Entry  Fri Jan 29 10:14:16 2021, Stephen, DailyProgress, Cryo vacuum chamber, Restarting Cryo vacuum chamber effort CryoLabImages_QILelog2530.zipIMG_8019.JPGIMG_8024.JPGIMG_8020.JPG
Entry  Fri Feb 5 08:50:02 2021, Stephen, DailyProgress, Cryo vacuum chamber, Successful cooldown, cold flange without shields 7x
    Reply  Fri Feb 5 14:13:08 2021, rana, DailyProgress, Cryo vacuum chamber, Successful cooldown in  
Entry  Wed Mar 3 16:14:18 2021, Aidan, Update, 2um Photodiodes, Bringing 2um PD testing back online Screen_Shot_2021-03-03_at_4.11.47_PM.png
Entry  Thu Mar 4 13:37:51 2021, Aidan, Update, 2um Photodiodes, Reference PD reading vs Power incident on viewport POW_IN_vs_REF_PD.csvIMG_1107.jpg
Entry  Thu Mar 4 16:12:26 2021, Aidan, Howto, 2um Photodiodes, JPL PD set up tutorial video 
Entry  Wed Mar 10 17:20:26 2021, Aidan, Update, 2um Photodiodes, Pumped chamber down briefly - connected vacuum gauge to the computer IMG_1204.jpgIMG_1200.jpgIMG_1191.jpgIMG_1190.jpgIMG_1199.jpg
Entry  Fri Mar 12 08:31:05 2021, Stephen, Howto, Cryo vacuum chamber, QIL Cryo setup how to videos and photo album 
Entry  Fri Mar 12 16:29:36 2021, Aidan, Update, 2um Photodiodes, Vacuum needs leak checking Screen_Shot_2021-03-12_at_4.28.54_PM.png
Entry  Tue Mar 16 18:45:43 2021, Aidan, DailyProgress, 2um Photodiodes, Cryo cool down and temperature rise - JPL PD LN2 (5 hours to rise) Screen_Shot_2021-03-16_at_6.44.09_PM.pngIMG_1397.jpgScreen_Shot_2021-03-16_at_7.09.34_PM.png
Entry  Tue Mar 16 20:50:14 2021, Aidan, Howto, Tutorial video, How to operate the PD pumping station 
Entry  Wed Mar 17 16:06:24 2021, aaron, Electronics, Equipment transfer, borrowed filter 
Entry  Fri Mar 19 13:51:16 2021, Aidan, Computing, General, Activated MATLAB on QIL-WS2 
Entry  Fri Mar 19 15:13:25 2021, Aidan, Computing, General, Adding fb4:/usr/share/advligorts to QIL-WS2 
Entry  Thu Mar 25 12:28:19 2021, Aidan, Computing, Cymacs, DAC channels not outputting voltages 
Entry  Mon Mar 29 14:16:33 2021, Aidan, Computing, CDS, Rebuilding C4TST with frames added to file Screen_Shot_2021-03-29_at_2.29.53_PM.png
Entry  Wed Mar 31 11:06:53 2021, Aidan, Computing, Cymacs, Rebuilding the Cymacs software to compile models 
Entry  Thu Apr 1 18:42:55 2021, Stephen , DailyProgress, Cryo vacuum chamber, Preparations for Q measurements  9x
Entry  Thu Apr 1 20:28:26 2021, Radhika, DailyProgress, 2um Photodiodes, Opened cryo chamber and removed old PD 
Entry  Thu Apr 1 20:33:42 2021, Stephen, DailyProgress, Cryo vacuum chamber, Installation of Radiation Shields 12x
Entry  Mon Apr 5 18:50:54 2021, Radhika, Summary, , Current PD testing schematic QIL_PD_testing.jpgQIL_PD_testing.graffle
Entry  Fri Apr 9 09:37:26 2021, Stephen, DailyProgress, Cryo vacuum chamber, Started cooldown with shielding, workpiece Si cantilever IMG_8558.JPGIMG_8559.JPGIMG_8562.JPG
Entry  Thu Apr 1 20:54:57 2021, Radhika, DailyProgress, 2um Photodiodes, Opened cryo chamber and removed old PD 7x
    Reply  Fri Apr 9 16:23:22 2021, rana, DailyProgress, 2um Photodiodes, Opened cryo chamber and removed old PD 
    Reply  Tue Apr 13 11:48:04 2021, Radhika, DailyProgress, 2um Photodiodes, Opened cryo chamber and removed old PD 
Entry  Wed Apr 14 09:49:38 2021, Stephen, DailyProgress, Cryo vacuum chamber,  IMG_8570.JPGIMG_8585.JPGcooldown_20210408_first_si_workpiece_with_shields_and_straps.png
Entry  Fri Apr 16 11:27:01 2021, Aidan, Update, 2um Photodiodes, 2um DC photodiode voltage weird drift with no incident power DC_2um_voltage_weirdness.png
    Reply  Fri Apr 16 13:05:05 2021, Aidan, Update, 2um Photodiodes, 2um DC photodiode voltage weird drift with no incident power IMG_2132.jpgFM30_31_w_latter_filtered.pngIMG_2134.jpgbias_bypassed.png
Entry  Tue Apr 20 09:43:49 2021, Radhika, Summary, 2um Photodiodes, Link to PD testing master doc 
Entry  Wed Apr 21 09:42:35 2021, Stephen, rana, Things to Buy, Cryo vacuum chamber, Reimagining QIL Cryo Vacuum Chamber 
Entry  Wed Apr 21 16:45:01 2021, Aidan, Lab Infrastructure, Cameras, Telephoto and macro lenses for smartphones IMG_2194.jpgIMG_2195.jpgIMG_2196.jpg
Entry  Fri Apr 30 08:09:08 2021, Stephen, DailyProgress, Cryo vacuum chamber, Simplifying cryocooler connections is WIP D2100320_cryostat_update_new_design_20210430.png
Entry  Mon May 3 16:56:59 2021, Stephen, DailyProgress, Cryo vacuum chamber, Cooling power of current setup IMG_8665.JPG
    Reply  Sun May 9 11:14:30 2021, Paco, DailyProgress, Cryo vacuum chamber, Cooling power of current setup strap_1D_heat_transfer.pdf
Entry  Mon May 3 17:32:29 2021, Radhika, Summary, 2um Photodiodes, Updated PD testing schematic / measurement table QIL_PD_testing.graffleQIL_PD_testing.pdfScreen_Shot_2021-05-03_at_17.16.20.png
    Reply  Wed May 5 00:34:14 2021, rana, Summary, 2um Photodiodes, Updated PD testing schematic / measurement table 
       Reply  Mon May 10 15:38:36 2021, rana, Summary, 2um Photodiodes, Keithley connections Screen_Shot_2021-05-10_at_3.37.29_PM.png
Entry  Tue May 11 19:23:51 2021, Radhika, DailyProgress, 2um Photodiodes, ADC noise level spectrum adcnoise_210511.xml.gzadcnoise.png
Entry  Mon May 17 09:52:37 2021, Radhika, DailyProgress, Cryo vacuum chamber, Large cyro chamber progress IMG_1615.jpegIMG_1625.jpegIMG_1634.jpegIMG_1641.jpeg
Entry  Wed May 19 08:40:47 2021, Stephen, DailyProgress, Cryo vacuum chamber, Damaged workpiece, but otherwise ready to pump down IMG_8743.JPGIMG_8745.JPG
    Reply  Thu May 20 16:40:09 2021, Radhika, DailyProgress, Cryo vacuum chamber, Damaged workpiece, but otherwise ready to pump down IMG_1646.jpegIMG_1651.jpegIMG_1654.jpegIMG_1661.jpeg
Entry  Thu May 20 16:57:32 2021, Koji, Electronics, General, Keithley Source Meter returned to Downs P_20210520_154439.jpgP_20210520_154505.jpgP_20210520_154523.jpg
Entry  Fri May 21 11:15:12 2021, Stephen, DailyProgress, Cryo vacuum chamber, Troubleshooting cryocooler - power cable not plugged in IMG_1662.jpegIMG_1664.jpeg
Entry  Mon May 24 15:47:30 2021, Radhika, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling cooling.png
    Reply  Mon May 24 16:49:17 2021, rana, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling PPP.jpg
       Reply  Tue May 25 13:19:41 2021, Radhika, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling 
    Reply  Tue May 25 16:38:17 2021, Stephen, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling --> started warmup cooling_full_20210525.png
       Reply  Thu May 27 16:48:35 2021, Radhika, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling --> started warmup 7x
          Reply  Mon May 31 11:38:13 2021, Radhika, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling 14x
             Reply  Wed Jun 2 20:06:07 2021, rana, DailyProgress, Cryo vacuum chamber, Weekend cryo chamber cooling 
Entry  Fri Jun 4 16:15:00 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown from 6/2-6/4 cooldown_6-2_6-4.png
Entry  Tue Jun 8 12:58:40 2021, Stephen, DailyProgress, Cryo vacuum chamber, Maximum power for temperature actuation IMG_8495.JPGIMG_8745.JPG
Entry  Wed Jun 9 13:35:07 2021, Radhika, DailyProgress, Cryo vacuum chamber, Heater actuation IMG_1722.jpeg
Entry  Thu Jun 10 15:13:26 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown modeling vs. data coldhead_capacity.pdfcooldown_model_vs_data.pdf
Entry  Fri Jun 11 16:00:31 2021, Radhika, DailyProgress, Cryo vacuum chamber, Large chamber heating heating_6-9.pdfheating_6-9_workpiece.pdf
Entry  Wed May 12 15:43:30 2021, Aidan, Summary, 2um Photodiodes, Chamber is leaking 
    Reply  Wed May 26 18:38:25 2021, Aidan, Summary, 2um Photodiodes, Chamber is leaking 
       Reply  Fri Jun 11 07:42:54 2021, Stephen, Summary, 2um Photodiodes, Chamber is leaking IMG_8865.JPGIMG_8881.JPG
          Reply  Fri Jun 11 16:48:31 2021, Aidan, Stephen, Summary, 2um Photodiodes, Chamber is leaking IMG_3002.jpgIMG_3001.jpg
Entry  Wed Jun 16 17:17:12 2021, Koji, Update, General, I2 cell P_20210616_170104.jpegP_20210616_170038.jpegP_20210616_170021.jpeg
Entry  Fri Jun 18 10:15:14 2021, Stephen, Update, Cryo vacuum chamber, Temperature sensor considerations RTD_Resistance_vs_Temperature_for_PPG102A6.png
Entry  Mon Jun 21 10:59:41 2021, Radhika, DailyProgress, Cryo vacuum chamber, Chamber updates 6/16-6/18 10x
Entry  Wed Jun 23 15:03:12 2021, Ian MacMillan, DailyProgress, CDS, Testing DAC2ADC code QIL_CDS_TEST.tar.gz
Entry  Fri Jun 25 09:47:33 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown data cooldown_6-21.pdfcooldown_model_vs_data_v2.pdf
Entry  Wed Jun 23 16:25:49 2021, Ian MacMillan, DailyProgress, General, Network Issue 
    Reply  Tue Jun 29 15:45:43 2021, Ian MacMillan, DailyProgress, General, Network Issue 
Entry  Tue Jun 29 17:16:29 2021, Ian MacMillan, DailyProgress, Cryo vacuum chamber, Temp Controller 
Entry  Tue Jun 29 17:29:16 2021, Stephen, Things to Buy, 2um Photodiodes, Integrating 2um PD measurements into Cryo Vacuum Chamber 
Entry  Fri Jul 2 11:27:01 2021, Radhika, DailyProgress, Cryo vacuum chamber, Ccooling updates 6/29-7/2 16x
Entry  Tue Jul 6 18:07:20 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown 7/1-7/6 cooldown_7-1.pdf
Entry  Fri Jul 9 10:57:58 2021, Radhika, Summary, Cryo vacuum chamber, CTC100 temperature extraction terminal1.png
Entry  Fri Jul 9 13:44:39 2021, Radhika, Summary, Cryo vacuum chamber, 1D cooling model updates model_vs_data_7-1.pdfcoldhead_capacity.pdfmodel_vs_data_7-1.pdf
Entry  Mon Jul 12 14:42:42 2021, Stephen, DailyProgress, Cryo vacuum chamber, RTD attached to coldhead with spring clamp, Si mass to be installed this week 
Entry  Thu Jul 15 23:34:17 2021, Koji, Summary, TempCtrl, Temprerature Log for cooling down / warming up temp_log_cooldown_20210709_1747.pdftemp_log_warmup_20210712_1315.pdf
Entry  Thu Jul 15 23:37:53 2021, Koji, Summary, Cryo vacuum chamber, Bonding work for the prep of the preliminary suspension test P_20210715_170102-1.jpgP_20210715_172218-1.jpgexperiment_plan.pdf
Entry  Wed Jul 21 14:53:28 2021, Koji, Summary, General, Jul 17, 2021: Canon camera / small silver tripod / macro zoom lens / LED ring light borrowed -> QIL  
    Reply  Fri Jul 23 20:53:40 2021, Koji, Summary, General, Jul 17, 2021: Canon camera / small silver tripod / macro zoom lens / LED ring light returned / ELectronics borrowed P_20210723_212158.jpg
Entry  Fri Jul 16 23:28:24 2021, Koji, Summary, Cryo vacuum chamber, Sus Test Work 07/16/2021 7x
    Reply  Sat Jul 17 00:55:41 2021, Koji, Summary, Cryo vacuum chamber, Temp Log 210716_2255 temp_log_cool_down_20210716_2255.pdf
       Reply  Mon Jul 19 15:57:17 2021, Stephen, Summary, Cryo vacuum chamber, Temp Log 210716_2255 
          Reply  Mon Jul 19 17:21:19 2021, Koji, Summary, Cryo vacuum chamber, Temp Log 210716_2255 temp_log_cool_down_20210716_2255.pdf
             Reply  Tue Jul 20 11:33:52 2021, Koji, Summary, Cryo vacuum chamber, A cooling model (Temp Log 210716_2255) cooling_model.pdfIMG_9390.JPGIMG_9391.JPG
                Reply  Tue Jul 20 17:28:30 2021, Koji, Summary, Cryo vacuum chamber, A cooling model (Temp Log 210716_2255) cooling_model.pdf
                   Reply  Wed Jul 21 21:05:59 2021, Koji, Summary, Cryo vacuum chamber, Test mass cooling (2021/07/16 ~ 2021/07/21) oplev_trend.png20210721201333_IMG_0765.jpeg20210716234113_IMG_0742.jpegScreenshot_from_2021-07-21_20-19-09.png
                      Reply  Thu Jul 22 22:03:45 2021, Koji, Summary, Cryo vacuum chamber, Test mass heating in progress (2021/07/21 ~ 2021/07/23) IMG-9395.jpgtemp_log_warmup_20210721_2052.pdf
                      Reply  Sun Jul 25 21:45:46 2021, Koji, Summary, Cryo vacuum chamber, About the radiation heat transfer model 
Entry  Fri Jul 30 09:48:11 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooling model updates from Koji's analysis cooldown_Cp_fixed.pdfcooldown_Cp_varying.pdfe_tm_comp_Cp_fixed.pdf
Entry  Fri Jul 30 14:44:56 2021, Stephen, Things to Buy, Cryo vacuum chamber, Upgrades and updates in advance of PD testing 
Entry  Fri Jul 30 12:22:15 2021, Radhika, DailyProgress, CDS, Connecting CTC100 to EPICS/rtcds system 
    Reply  Fri Jul 30 17:28:14 2021, Radhika, DailyProgress, CDS, Connecting CTC100 to EPICS/rtcds system 
       Reply  Fri Jul 30 18:18:21 2021, Koji, DailyProgress, CDS, Connecting CTC100 to EPICS/rtcds system 
          Reply  Mon Aug 2 17:24:20 2021, Radhika, DailyProgress, CDS, Connecting CTC100 to EPICS/rtcds system 
             Reply  Mon Aug 2 21:51:37 2021, Koji, DailyProgress, CDS, Connecting CTC100 to EPICS/rtcds system 
Entry  Mon Jul 26 01:30:42 2021, Koji, Summary, Cryo vacuum chamber, Prep for the 2nd cooling of the suspension 
    Reply  Mon Jul 26 22:49:00 2021, Koji, Summary, Cryo vacuum chamber, Aquadag painting 10x
       Reply  Wed Jul 28 00:59:47 2021, Koji, Summary, Cryo vacuum chamber, The test mass successfully suspended P_20210727_154143.jpegP_20210727_190356.jpegP_20210727_190426.jpegP_20210727_190543.jpeg
          Reply  Thu Jul 29 00:42:38 2021, Koji, Summary, Cryo vacuum chamber, The test mass successfully suspended 
             Reply  Thu Jul 29 13:11:17 2021, Koji, Summary, Cryo vacuum chamber, Cooling progress: Update temp_log_cool_down_20210728_1830.pdfcooling_model1.pdfcooling_model2.pdfOSEM_cooling.pdf
                Reply  Fri Jul 30 12:22:56 2021, Koji, Summary, Cryo vacuum chamber, Cooling curve comparisons comparison_cold_head.pdfcomparison_inner_shield.pdfcomparison_test_mass.pdf
                   Reply  Sun Aug 1 22:22:00 2021, Koji, Summary, Cryo vacuum chamber, Cooling update temp_log_cool_down_20210728_1830.pdfcooling_meas.pdfOSEM_cooling.pdfcooldown_210728.zip
                      Reply  Mon Aug 2 13:25:32 2021, Stephen, DailyProgress, Cryo vacuum chamber, Warmup started 02 August 
                         Reply  Tue Aug 3 23:56:00 2021, Koji, DailyProgress, Cryo vacuum chamber, Warmup started 02 August P_20210804_000247.jpgP_20210803_235421.jpg
Entry  Wed Aug 4 18:55:58 2021, aaron, DailyProgress, Cryo vacuum chamber, loading cantilevers into megastat 6x
    Reply  Thu Aug 5 14:12:36 2021, Stephen, DailyProgress, Cryo vacuum chamber, loading cantilevers into megastat (and actions toward pumping down) 
Entry  Wed Jul 21 13:14:11 2021, Paco, Lab Infrastructure, 2micronLasers, Brimrose AOM and amplifier 
    Reply  Fri Aug 6 16:15:03 2021, Paco, Lab Infrastructure, 2micronLasers, Brimrose AOM and amplifier 
Entry  Sun Aug 15 00:33:15 2021, Koji, Summary, Cryo vacuum chamber, Aquadag painting on the inner shield IMG_9636.JPGIMG_9632.JPGIMG_9646.JPG
Entry  Wed Aug 18 13:06:03 2021, Aidan, Stephen, Lab Infrastructure, Cleanliness, North table clean-up IMG_4230a.jpgIMG_4232a.jpg
Entry  Thu Aug 5 11:53:26 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS model_fit_v_data.pdf
    Reply  Wed Aug 11 14:58:47 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS rad_model_fit_v_data.pdfrad_cond_model_fit_v_data.pdf
       Reply  Wed Aug 11 18:00:19 2021, Koji, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS 
          Reply  Fri Aug 13 15:14:14 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS rad_295_model_fit_v_data.pdf
             Reply  Fri Aug 13 21:01:42 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS 
                Reply  Thu Aug 19 14:34:10 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS model_fit_tm_painted.pdfmodels_painted.pdf
                   Reply  Fri Aug 20 13:44:58 2021, rana, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS 
                      Reply  Fri Aug 20 14:05:45 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cooldown model fitting for MS 
Entry  Thu Aug 26 16:10:16 2021, Aidan, Lab Infrastructure, Cleanliness, Two under table equipment racks purchased for North Table - one installed so far IMG_4407.jpgIMG_4423.jpgIMG_4421.jpgIMG_4422.jpg
Entry  Fri Aug 27 15:33:28 2021, Aidan, Computing, Cymacs,  
Entry  Thu Aug 5 09:20:44 2021, Aidan, Laser, 2um Photodiodes, Optical design for 2um PD in new cryo chamber Cryo_Chamber_optical_layout.pdf
    Reply  Thu Aug 5 12:39:56 2021, Aidan, Laser, 2um Photodiodes, Optical design for 2um PD in new cryo chamber Cryo_in-air_setup.pdf
       Reply  Thu Aug 5 14:29:42 2021, Stephen, Laser, 2um Photodiodes, Optical design for 2um PD in new cryo chamber IMG_9685.JPGIMG_9687.JPGrouting_markup_of_IMG_9688.pngIMG_9682.JPG
          Reply  Tue Aug 24 15:01:25 2021, Stephen, Laser, 2um Photodiodes, 2um PD in new cryo chamber 
             Reply  Thu Aug 26 14:31:46 2021, Aidan, Stephen, Laser, 2um Photodiodes, Incident power calibration of 2um PD in new cryo chamber IMG_4420.jpgREF_PD_POW_CAL_cryo.pdf
                Reply  Fri Aug 27 17:57:30 2021, Stephen, DailyProgress, 2um Photodiodes, Start of PD pumpdown  
                   Reply  Sat Aug 28 07:01:21 2021, Aidan, DailyProgress, 2um Photodiodes, Start of PD pumpdown  20210828_-_IMG_4445.jpg20210828_-_IMG_4443.jpg
                      Reply  Sun Aug 29 11:17:43 2021, Aidan, DailyProgress, 2um Photodiodes, Start of PD pumpdown  Screen_Shot_2021-08-29_at_11.16.55_AM.pngScreen_Shot_2021-08-29_at_11.22.03_AM.png
                         Reply  Mon Aug 30 08:04:52 2021, Aidan, DailyProgress, 2um Photodiodes, Monday morning observation of JPL A1 PD cool down  Screen_Shot_2021-08-30_at_8.04.15_AM.png
Entry  Tue Sep 7 09:14:22 2021, shruti, Misc, Equipment transfer, TED200C borrowed 
Entry  Tue Sep 7 08:12:50 2021, Aidan, Computing, Cymacs, +/-18V power supply to AI/AA chassis was actually +18V, -14.5V IMG_4578.jpgIMG_4577.jpg
    Reply  Tue Sep 7 11:52:40 2021, rana, Computing, Cymacs, +/-18V power supply to AI/AA chassis was actually +18V, -14.5V 
Entry  Wed Sep 8 14:35:22 2021, Aidan, DailyProgress, 2um Photodiodes, Running automated testing suite on A1 PD 7x
    Reply  Thu Sep 9 09:23:56 2021, Aidan, DailyProgress, 2um Photodiodes, Running automated testing suite on A1 PD 
       Reply  Fri Sep 10 09:11:05 2021, Aidan, DailyProgress, 2um Photodiodes, Running automated testing suite on A1 PD 
          Reply  Fri Sep 10 20:13:12 2021, Aidan, DailyProgress, 2um Photodiodes, Running automated testing suite on A1 PD 
Entry  Tue Sep 14 15:58:51 2021, Radhika, DailyProgress, Cryo vacuum chamber, Cold plate cooling limited by copper braid 
Entry  Tue Sep 14 15:17:03 2021, Stephen, DailyProgress, Cryo vacuum chamber, Chamber up to air, lids removed 
    Reply  Wed Sep 15 08:22:32 2021, Aidan, DailyProgress, Cryo vacuum chamber, CONTAMINATION: Black paint flecks throughout chamber IMG_4686.jpgIMG_4687.jpgIMG_4689.jpgIMG_4690.jpg
Entry  Wed Sep 15 08:33:39 2021, Aidan, Update, 2um Photodiodes, Video review of 2um testing setup post A1 testing 
Entry  Thu Sep 16 10:33:59 2021, Aidan, Computing, 2um Photodiodes, Automation and analysis scripts for 2um data taking autorun2021.shmaximize_output_power.pyA1_analysis.py
    Reply  Mon Sep 20 14:26:38 2021, rana, Computing, 2um Photodiodes, Automation and analysis scripts for 2um data taking 
Entry  Wed Sep 22 16:40:19 2021, Aidan, Laser, 2um Photodiodes, Beam size measurements of the 2um beam on the PD PD_measurement_layout.pngPD_occlusion_measurements.txt
Entry  Tue Sep 28 08:23:11 2021, Aidan, Update, 2um Photodiodes, Distances between optics, collimating lens, focussing lens and photodiode JPL_PD_collimating_lens_Optical_layout.pdfJPL_PD_optical_propagation_and_beam_size.pdf
Entry  Fri Oct 1 17:41:25 2021, Paco, Misc, Equipment transfer, Fiber alignment pen 
Entry  Sat Oct 2 23:57:50 2021, Stephen, DailyProgress, Cryo vacuum chamber, Chamber pumping down, carbon paint flakes cleaned up 
Entry  Sun Oct 3 08:22:49 2021, Aidan, Summary, 2micronLasers, Starting data taking and second test of JPL PD A1 
    Reply  Wed Oct 6 13:50:18 2021, Aidan, Summary, 2micronLasers, Starting data taking and second test of JPL PD A1 
       Reply  Thu Oct 7 08:07:03 2021, Aidan, Summary, 2micronLasers, Starting data taking and second test of JPL PD A1 
          Reply  Mon Oct 11 08:35:21 2021, Aidan, Summary, 2micronLasers, Starting data taking and second test of JPL PD A1 Screenshot_from_2021-10-11_08-36-06.png
             Reply  Mon Oct 18 15:25:14 2021, Aidan, Summary, 2micronLasers, Starting data taking and second test of JPL PD A1 
Entry  Thu Oct 21 15:32:32 2021, Aidan, Radhika, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K IMG_5305.jpg
    Reply  Thu Oct 21 16:52:26 2021, rana, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K 
       Reply  Thu Oct 21 17:48:33 2021, Aidan, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K 
          Reply  Fri Oct 22 09:20:13 2021, Aidan, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K 
          Reply  Fri Oct 22 12:04:13 2021, rana, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K 
             Reply  Fri Oct 22 13:31:36 2021, Chris, Laser, 2um Photodiodes, Improved measurement of QE on photodiodes ~89% at 140K 
Entry  Mon Oct 25 16:10:51 2021, Aidan, Update, CDS, Restarted computers and front-end model following campus power outage  
Entry  Mon Oct 25 16:13:47 2021, Aidan, Update, Cryo vacuum chamber, Heater left on - chamber got warm Screenshot_from_2021-10-25_16-19-39.png
    Reply  Tue Oct 26 07:32:52 2021, Aidan, Update, Cryo vacuum chamber, Heater left on - chamber got warm 
       Reply  Tue Oct 26 08:43:38 2021, Aidan, Update, Cryo vacuum chamber, CTC100 temperature alarm and heater shutoff Screenshot_from_2021-10-26_08-42-57.pngIMG_5371.jpgIMG_5396.jpgIMG_5401.jpg
Entry  Wed Oct 27 10:18:33 2021, Aidan, Stephen, Summary, Cryo vacuum chamber, Inspection of Megastat post 408K event and pumping timeline 8x
Entry  Fri Nov 12 08:21:22 2021, Aidan, Summary, 2um Photodiodes, Results from JPL PD: A1-Test3 A1_test3_nominal_QE.pdfA1_test3_darkcurrent.pdfA1_test3_noise_spectra_rev.pdf
    Reply  Fri Nov 12 10:54:55 2021, rana, Summary, 2um Photodiodes, Results from JPL PD: A1-Test3 
Entry  Fri Nov 12 14:21:32 2021, Stephen, Radhika, DailyProgress, Cryo vacuum chamber, Upgrade to Rigid Copper Bar, and assorted transitions from PD testing 10x
Entry  Fri Nov 19 09:36:52 2021, Anchal, Misc, Equipment transfer, Borrowing two 2" optics PXL_20211119_174146457.jpg
Entry  Fri Dec 3 09:31:40 2021, Radhika, DailyProgress, Cryo vacuum chamber, Transitioning MS cooldown fitting to MCMC scheme MS.stanstan_blackcoat_fit.pdf
    Reply  Sun Dec 5 17:33:50 2021, rana, DailyProgress, Cryo vacuum chamber, Transitioning MS cooldown fitting to MCMC scheme 
Entry  Thu Dec 16 17:57:15 2021, Radhika, Stephen, Summary, Cryo vacuum chamber, Megastat geometric parameters D2000310_y-003_20211222.png
Entry  Fri Nov 12 14:31:38 2021, Stephen, Radhika, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with better shield emissivity IMG_2738.jpegIMG_2741.jpegIMG_2742.jpegIMG_2745.jpegIMG_2747.jpeg
    Reply  Fri Nov 19 14:01:40 2021, Stephen, Radhika, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with better shield emissivity comp_cooldown_728_cooldown_1116.pdf
    Reply  Fri Dec 10 15:58:57 2021, Stephen, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with worse inner shield inner surface emissivity 
       Reply  Thu Dec 16 15:54:44 2021, Stephen, Radhika, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with worse inner shield inner surface emissivity - CTC100 temperature control success cooldown_12-10_all.pdfcooldown_12-10_vs_11-16.pdf
          Reply  Tue Dec 21 15:33:39 2021, Stephen, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with worse inner shield inner surface emissivity - next run repeating 
             Reply  Wed Dec 31 15:59:59 1969, Stephen, DailyProgress, Cryo vacuum chamber, Radiative Cooling of Si Mass, with worse inner shield inner surface emissivity - retry run was successful cooldown_12-21_vs_12-10.pdfMegastat_Heat_Load_Sketch.png12_21_cooldown_fit.png
Entry  Mon Jan 10 16:46:19 2022, Paco, Misc, Equipment transfer, 2 inch GYRO optics PXL_20220111_004553530.jpg
Entry  Fri Jan 7 14:54:58 2022, Stephen, DailyProgress, Cryo vacuum chamber, Fastest Radiative Cooling run started 14 Jan 
    Reply  Tue Jan 18 16:11:35 2022, Stephen, DailyProgress, Cryo vacuum chamber, Status of Fastest Radiative Cooling run started 14 Jan 5w_input_qil_cryostat_20220119.png5w_input_121_to_145_hours_qil_cryostat_20220124.png
Entry  Fri Jan 21 13:28:48 2022, Radhika, DailyProgress, Cryo vacuum chamber, Heat transfer between grease joints and pressure joints thermal_conductance_joints.png
    Reply  Fri Jan 21 17:32:40 2022, rana, DailyProgress, Cryo vacuum chamber, Heat transfer between grease joints and pressure joints 
       Reply  Tue Jan 25 10:24:14 2022, rana, DailyProgress, Cryo vacuum chamber, Heat transfer between grease joints and pressure joints 
       Reply  Tue Jan 25 13:15:40 2022, rana, DailyProgress, Cryo vacuum chamber, Heat transfer between grease joints and pressure joints 
          Reply  Tue Jan 25 14:01:27 2022, Stephen, DailyProgress, Cryo vacuum chamber, Heat transfer between grease joints and pressure joints 
             Reply  Fri Jan 28 10:31:15 2022, rana, Summary, Tutorial video, oh no, stap the units madness, aaaaahhhh!!! noooooo!!!! 
Entry  Mon Jan 31 15:40:21 2022, Stephen, DailyProgress, , 31 Jan Fastest Radiative Cooling run started 
    Reply  Fri Feb 4 14:00:19 2022, Radhika, DailyProgress, , 31 Jan Fastest Radiative Cooling run started Cooldown_0114_analyzed.pdfCooldown_0131_analyzed.pdfCooldown_0131_copperbar_halfR.pdfCooldown_0131_flexstrap_halfR.pdf
       Reply  Wed Feb 9 15:21:27 2022, rana, Howto, TempCtrl, plots 
    Reply  Mon Feb 7 16:06:36 2022, Stephen, DailyProgress, , 31 Jan Fastest Radiative Cooling run, ended 07 Jan 
Entry  Mon Feb 7 11:57:38 2022, Stephen, DailyProgress, Cryo vacuum chamber, Doubled Thermal Linkage Capacity run started 11 Feb 2022 D2000310_y-004_section_double_linkage_20220207.png
    Reply  Tue Feb 15 11:59:22 2022, Radhika, DailyProgress, Cryo vacuum chamber, Doubled Thermal Linkage Capacity run started 11 Feb 2022 Cu_bar_comparison.pdfcooldown_0211_all.pdf
       Reply  Tue Feb 15 16:54:27 2022, rana, DailyProgress, Cryo vacuum chamber, Doubled Thermal Linkage Capacity run started 11 Feb 2022 
    Reply  Wed Feb 16 11:35:18 2022, Stephen, DailyProgress, Cryo vacuum chamber, Doubled Thermal Linkage Capacity run started 11 Feb 2022 
Entry  Thu Feb 24 10:44:06 2022, Radhika, DailyProgress, Cryo vacuum chamber, Double copper bar cooldown rerun started 02/23 IMG_3095.jpgIMG_3096.jpgIMG_3083.jpgIMG_3087.jpgIMG_3092.jpg
    Reply  Tue Mar 1 15:59:34 2022, Radhika, DailyProgress, Cryo vacuum chamber, Double copper bar cooldown rerun started 02/23 
       Reply  Fri Mar 4 13:18:09 2022, Radhika, DailyProgress, Cryo vacuum chamber, Double copper bar cooldown rerun started 02/23 02-24_cooldown_data.pdf02-24_cooldown_data_comparison.pdfcooldown_0224_bestfit.pdf
Entry  Thu Mar 10 16:21:11 2022, Radhika, DailyProgress, Cryo vacuum chamber, Insulated outer shield cooldown started 3/10 9x
    Reply  Mon Mar 14 14:04:54 2022, Radhika, DailyProgress, Cryo vacuum chamber, Insulated outer shield cooldown started 3/10 
Entry  Tue Feb 22 07:53:06 2022, Yehonathan, Update, WOPO, Waking up WOPO 
    Reply  Fri Feb 25 17:09:53 2022, shruti, Update, WOPO, Waking up WOPO - green beam 
       Reply  Wed Mar 2 14:38:55 2022, Yehonathan, Update, WOPO, Waking up WOPO - some more fiddling and a plan 
          Reply  Fri Mar 4 11:49:45 2022, shruti, Update, WOPO, Waking up WOPO - attempts at readout LO_shot_noise.pdf
             Reply  Thu Mar 10 17:12:01 2022, awade, Update, WOPO, Waking up WOPO - attempts at readout 
                Reply  Wed Mar 16 12:22:44 2022, Yehonathan, Update, WOPO, Waking up WOPO - attempts at readout Moku_Noise.pdfPD_Connected_no_light.pdfDiff_Channel.pdf
                   Reply  Tue Mar 22 09:19:38 2022, shruti, Update, WOPO, Waking up WOPO - back to green path