40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog, Page 2 of 56  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  51   Fri May 2 22:54:44 2008 DmassComputing ScreensI made a simulink model and put it here: /cvs/cds/advLigo/src/epics/simLink/atf.mdl

as instructed by the rolf wiki:
  
  52   Mon May 5 20:32:50 2008 DmassComputingGeneralMEDM, FB, FE, EtcI restarted the oms box in the rack, and was
in the process of trying to get new medm
control screens up with Rob. I now have neither
  
  53   Tue May 6 18:18:59 2008 DmassLaserEOMEOM Phase lagI used the experimental setup below to measure
the transfer function between the EOM (which
is before the amplifier) and the reflections
 TF_setup1.pngMODSUM.png 
  54   Wed May 7 04:44:31 2008 DmassComputingGeneralDTT and Fast Channels fixedThe playback in dataviewer on the fast channels
was semi broken (would not display full data
on a playback, but could do all else).
  
  55   Tue May 13 12:37:31 2008 DmassLaserFiberNew fiberWe got a box of fiber from Boston (Marie Woods).
It is now on the optics table in the bridge
basement.
 00011.png 
  56   Mon May 19 17:28:44 2008 DmassLaserPMCCavity Pole Measurement on the PMCMeasurement of the PMC cavity pole:

The following was done at powers of .234
  
  57   Tue May 20 15:55:31 2008 DmassLaserEOMEOM Phase lagThe attached transfer function was measured
with the experimental setup outlined in entry
53. The first transfer function (Raw Data)
 RawTF.pngcorrtf.png 
  58   Thu May 29 20:00:48 2008 tobinComputingFuglyborkspace compilingDmass and I tried to compile and install a
new system on the borkspace machine here.
  
  59   Sun Jun 1 18:52:49 2008 tobinComputingGeneralborkspace compilingFollowing Alex's suggestions, I fixed the
front-end problems we were encountering the
other day.
  
  60   Fri Jul 11 16:20:21 2008 Stefan BallmerElectronics PMCSince the digital system was in an ambigous
state I locked the PMC using a SR560.
I did this so I can use the lab setup to
  
  61   Mon Jul 14 16:01:45 2008 Stefan BallmerElectronicsISSH1 ISS spare testedI tested the modified H1 ISS spare using a
post-PMC sensing.
I got the expected performance in-loop (about
  
  62   Wed Jul 16 11:47:18 2008 DmassComputingGeneralFront End Machine NamechangeThe front end machine in the Bridge Basement
has been renamed "atf" from "oms".
  
  63   Thu Jul 17 16:44:27 2008 DmassLaserPSLLaser is offLeaving laser off while I hack at screens
downstairs. Feel free to turn on for anything.
  
  64   Fri Jul 18 16:14:28 2008 DmassElectronicsGeneralUniversal PDH boxI just picked up the "Universal PDH Box" prototype
from Rich Abbott.
 PDH_User_Manual1.pdfUniPDH.png 
  65   Tue Jul 22 18:43:06 2008 DmassComputingfubardigital control broken.I tried to restore the hacked up oms control
system via a series of escalating measures.
  
  66   Wed Jul 23 12:04:01 2008 DmassElectronicsGeneralUniversal PDH box[quote]I just picked up the "Universal PDH
Box" prototype from Rich Abbott.
 PDH_LF.pngPDH_HF.png 
  67   Fri Jul 25 14:59:24 2008 DmassComputingfubardigital control broken.[quote]I tried to restore the hacked up oms
control system via a series of escalating
measures.
  
  68   Fri Jul 25 15:23:14 2008 DmassLaserPSLNew Vertical PSLWith the installation of the new "clear top"
on the PSL (see picture), an interesting
design feature has come to light.
 NPRO.pngHEPA.png 
  69   Fri Jul 25 17:07:34 2008 DmassLaserPMCCavity Pole Measurement on the PMC[quote]Measurement of the PMC cavity pole:

The following was done at powers of .234
  
  70   Mon Jul 28 15:58:49 2008 DmassComputingDAQDaq not recordingThere is still something wonky with the DAQ.
Nothing appears to be writing at the moment,
as I can only get 8 seconds of data from
  
  71   Tue Jul 29 00:47:37 2008 MashaLaserFibermach zehnder setupAs per dmass's prodding, I am putting up some
pictures of what I'm doing. 
 setup1.JPGsetup3.JPGsetup4.JPG 
  72   Tue Jul 29 00:58:36 2008 MashaLaserFiberfirst fiber noise measurementI'm attaching the fiber noise measurement
from one mach zehnder channel 
along with some noise sources. The total
 MZnoise_sources0727.png 
  73   Fri Aug 1 14:52:27 2008 DmassComputingDAQDaq not recording[quote]There is still something wonky with
the DAQ. Nothing appears to be writing at
the moment, as I can only get 8 seconds of
  
  74   Fri Aug 1 15:06:11 2008 DmassComputingCDSATF systemI made a preliminary generic model in simulink.
This is stored on [B]ws1[/B] as /users/dmass/atf.mdl
  
  75   Tue Aug 5 15:23:38 2008 DmassComputingCDSATF system[quote]I made a preliminary generic model
in simulink. This is stored on [B]ws1[/B]
as /users/dmass/atf.mdl
  
  76   Mon Aug 11 14:15:57 2008 DmassComputingCDSATF system[quote]I made a preliminary generic model
in simulink. This is stored on [B]ws1[/B]
as /users/dmass/atf.mdl
  
  77   Mon Aug 11 15:32:00 2008 Stefan BallmerElectronicsGeneralno DAC output voltage when running OMS didgital systemI tried to use the OMS digital system for
a measurement, but I couldn't get the DAC
output to work.
  
  78   Fri Aug 15 02:17:46 2008 DmassElectronicsGeneralno DAC output voltage when running OMS didgital system[quote]I tried to use the OMS digital system
for a measurement, but I couldn't get the
DAC output to work.
  
  79   Fri Aug 15 15:59:07 2008 DmassComputingDAQDAC DAQ and ADC workingThe problem was the timing. I changed what
the simulink .mdl file wanted for a clock
signal to what it was actally getting (64
  
  80   Mon Aug 18 23:46:42 2008 DmassComputingDAQMore on the DAQIt appeared today that the DAQ channels wouldnt
record. Only one would write no matter how
I edited the .ini file.
  
  81   Wed Aug 20 23:19:39 2008 DmassLaserDoublingPreliminary Doubling MZ SetupA prelim expermintal setup for measuring the
phase/freq noise of 532 nm light generated
by PPKTP crystals relative to the 1064 nm
 MachZenderPPKTP.PNG 
  82   Tue Sep 2 11:01:00 2008 AidanElectronicsFiberFiber stabilization loop diagramAttached is a diagram of the current version
of the stabilization loop. The beam (red)
into the AOM is the output from the fiber
 masha_layout_elec.png 
  83   Tue Sep 2 15:06:42 2008 AidanLaserFiberAttempted calibration of fiber noise ... issues!
I tried to calibrate the fiber phase noise
measurements in DTT by determining the fringe
 peak_peak_calibration.pdf 
  84   Tue Sep 2 22:48:47 2008 DmassLaserPSLConnectors neededI am trying to chase down the source of the
long time scale sharp fluctiations in intensity.
I need to start reading out the diagnostic
 connectors.png 
  85   Tue Sep 2 23:09:38 2008 AidanLaserFiberAttempted calibration of fiber noise. NPRO current = 1.903A[quote]
I tried to calibrate the fiber phase noise
measurements in DTT by determining the fringe
 peak_peak_calibration_1903mA.eps 
  86   Wed Sep 3 13:35:56 2008 AidanLaserFiberCalibrated noise spectra ... does not agree with previous measurementsI recorded the closed loop, open loop and
electronics noise in the current fiber stabilization
system (single-pass through fiber, AOM after
 noise_calibrated_080902.jpgnoise_calibrated_080902.eps 
  87   Wed Sep 3 16:43:56 2008 Aidan, BramLaserFiberFringe visibility fluctuation ... Bram's suggestions[quote]
I tried to calibrate the fiber phase noise
measurements in DTT by determining the fringe
  
  88   Wed Sep 3 18:22:20 2008 AidanLaserFiberCalibrated noise spectra ... does not agree with previous measurements[quote]I recorded the closed loop, open loop
and electronics noise in the current fiber
stabilization system (single-pass through
  
  89   Fri Sep 5 03:24:37 2008 DmassLaserPSLConnectors needed[quote]I am trying to chase down the source
of the long time scale sharp fluctiations
in intensity. I need to start reading out
  
  90   Tue Sep 9 15:49:22 2008 DmassLab InfrastructureHVACHEPA FiltersI had turned off the east HEPA filter with
Masha for a noise measurement, and I forgot
to turn it back on until today. Also, it
  
  91   Tue Sep 9 16:36:01 2008 DmassLaserPSLConnectors neededI got the replacement chiller (a Neslab Thermoflex1400)
from 046 W. Bridge. I unpacked it and moved
it by the PSL optics table in 058 W. Bridge.
  
  92   Tue Sep 16 22:55:30 2008 DmassLaserPSLConnectors neededPeter King and I hooked up the chiller to
itself and ran it looking for "gunk" in the
system. We satisfied ourselves that there
  
  93   Fri Sep 19 13:18:00 2008 DmassLaserPSLChiller on. 35W on.Peter got word back from Christian and told
me how to modify the adapter he made (schematic
to be posted later when he emails it to me).
  
  94   Sun Sep 21 15:45:21 2008 DmassLaserPSLChiller on. 35W on.[quote]Peter got word back from Christian
and told me how to modify the adapter he
made (schematic to be posted later when he
 Chiller_Back.png 
  95   Mon Sep 22 18:03:34 2008 DmassComputingDAQDAQ IS BACK - as is the 35W[B]The Chiller appears to not be leaking.
There are no squeaks coming from under the
table.
  
  96   Mon Sep 22 20:20:25 2008 AidanLaserFiberFringe magnitude fluctuation investigation
The attached photo shows the fiber coupler
in question and the ROLL angle adjustment
 fiber_coupler_rotation_angle_output_fluctuation.jpg00003.jpg 
  97   Tue Sep 23 10:15:15 2008 AidanLaserFiberFringe magnitude fluctuation investigation - why isn' the maximum 45 degrees from the minimum?[quote]
The attached photo shows the fiber coupler
in question and the ROLL angle adjustment
  
  98   Tue Sep 23 12:10:08 2008 AidanLaserFiberMaximized fiber coupler ROLL angle.
Set the input fiber coupler roll angle to
190 degrees on the graduated scale. Rotated
  
  99   Wed Oct 8 13:40:02 2008 DmassLaserPSLChiller NoiseThe new chiller was making a noise (as reported
to me by John).
  
  100   Thu Oct 9 08:47:54 2008 AidanLaserFiberDismantled fiber stabilization setup

Packed up the current setup. Am going to
  
ELOG V3.1.3-