40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Entry  Fri Jul 30 13:38:56 2010, Dmass, Laser, Doubling, Mode Matching for Ovens OvenMM.pdf
    Reply  Tue Aug 3 21:43:40 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
       Reply  Tue Aug 3 23:15:14 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
          Reply  Wed Aug 4 17:21:56 2010, Alastair, Laser, Doubling, Mode Matching for Ovens 
          Reply  Sat Aug 7 19:04:07 2010, Dmass, Laser, Doubling, Mode Matching for Ovens 
Message ID: 882     Entry time: Fri Jul 30 13:38:56 2010     Reply to this: 899
Author: Dmass 
Type: Laser 
Category: Doubling 
Subject: Mode Matching for Ovens 

I redid the mode matching into the ovens to account for the dispersion of the material affecting the Rayleigh range (like this)

I used Zr = L_crystal / 2 / n

Attachment 1: OvenMM.pdf  14 kB  Uploaded Fri Jul 30 14:39:33 2010  | Show | Show all
ELOG V3.1.3-