Author: Dmass 
Type: Laser 
Category: Doubling 
Subject: Mode Matching for Ovens 

I redid the mode matching into the ovens to account for the dispersion of the material affecting the Rayleigh range (like this)

I used Zr = L_crystal / 2 / n

Attachment 1: OvenMM.pdf  14 kB  Uploaded Fri Jul 30 14:39:33 2010  | Hide | Hide all
OvenMM.pdf
ELOG V3.1.3-