Subject: Seismometer Measurements Continued 

I've added SR560s to all three channels of the seismometer now.  They're DC coupled with a gain of 100, low pass filter at 10k and I'm running them on battery to avoid grounding the seismometer outputs.  The manual says that the battery should last 20hours so we might need to use a different solution to get more data (I'm assuming we don't want to use the mini circuits bnc transformers for this since it's not RF?).

We are now well above the DAQ noise.  Here is a plot showing 10 averages of the vertical, N/S and E/W data plotted calibrated in volts (GPS 964463447).  We will now take seismic data for 24hours.  Setup completed at 11.40am July29.

Attachment 1: 10_07_29_seismic01.pdf  54 kB  Uploaded Thu Jul 29 13:11:36 2010  | Hide | Hide all