Message ID: 816     Entry time: Wed Jun 16 23:10:28 2010     In reply to: 815     Reply to this: 818
Author: Dmass 
Type: Computing 
Category: DAQ 
Subject: Attempt at oven transfer functions 

Quote:

3040 P/I settings -

I = Slow <=> 0.0162 A/s/K

P = 2 <=> 0.0172 A/K

 

 A Couple more measurements yielded:

  • I = Slow <=> 0.0172 A/s/K
  • P = 1 <=> 0.0098 A/K

And

  • I = Fast <=>0.0848 A/s/K

Next I am hooking up the RS232 connector to one of the computers to see if I can get temperature logged, so that I can actually do something with it.