Mon Mar 22 15:01:24 2010, Dmass, Laser, ISS, ISS Spectra   
|
Tue Mar 23 15:01:29 2010, Dmass, Laser, ISS, ISS Spectra 
|
Tue Mar 23 17:05:11 2010, Dmass, Laser, ISS, ISS Spectra
|
Tue Mar 23 21:24:57 2010, Dmass, Laser, ISS, ISS Spectra
|
Wed Mar 24 00:09:39 2010, Dmass, Laser, ISS, ISS Spectra
|
Wed Mar 24 22:12:49 2010, Mott, Laser, ISS, fb0 error
|
Fri Mar 26 17:05:43 2010, Mott, Laser, ISS, fb0 error
|
Tue Mar 30 16:44:20 2010, Mott, Laser, ISS, fb0 error
|
Fri Apr 9 11:35:56 2010, Mott, Laser, ISS, fb0 error
|
Thu Mar 25 02:06:53 2010, Dmass, Laser, ISS, ISS Spectra
|
Thu Mar 25 02:38:54 2010, Koji, Laser, ISS, ISS Spectra
|
Thu Mar 25 10:38:24 2010, mevans, Laser, ISS, ISS Spectra
|
Thu Mar 25 13:29:18 2010, Dmass, Laser, ISS, ISS Spectra
|
Thu Mar 25 14:16:32 2010, Dmass, Laser, ISS, MZ Spectra! 
|
|
Message ID: 705
Entry time: Thu Mar 25 02:06:53 2010
In reply to: 690
Reply to this: 706
|
Author: |
Dmass |
Type: |
Laser |
Category: |
ISS |
Subject: |
ISS Spectra |
|
|
Hartmut, Koji, and Matt came to party with me downstairs. I am tired so the plots and pix will follow at a later date...
We
- Locked the PMC in analog with an SR560
- Locked the Mach Zehnder with a PZT I had made up forever ago, using the spare output from the ISS drive box (with the IR PD difference signal)
- Changed the ISS to supress noise in the MZ PD sum output
and
- Saw a noise of 100 uV/rtHz at 10 Hz, which corresponds to ~20 urad/rtHz at 10 Hz. This is about a factor of 5 improvement over the previous result, with no subtraction yet.
Huzzah. |