40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Message ID: 5     Entry time: Fri Oct 26 15:38:43 2007
Author: Tobin Fricke 
Type: Laser 
Category: PSL 
Subject: Polarizer 
On Tuesday we installed a λ/2 plate and a polarized beamsplitter after the laser aperture; attached to this entry is a measurement of transmitted power versus polarizer angle.
Attachment 1: polarizer.pdf  6 kB  | Hide | Hide all | Show all
polarizer.pdf
Attachment 2: polarizer.m  1 kB  | Show | Hide all | Show all
ELOG V3.1.3-