Message ID: 5     Entry time: Fri Oct 26 15:38:43 2007
Author: Tobin Fricke 
Type: Laser 
Category: PSL 
Subject: Polarizer 
On Tuesday we installed a λ/2 plate and a polarized beamsplitter after the laser aperture; attached to this entry is a measurement of transmitted power versus polarizer angle.
Attachment 1: polarizer.pdf  6 kB  | Show | Hide all | Show all
Attachment 2: polarizer.m  1 kB  | Hide | Hide all | Show all
% Polarizer calibration / Rana's lab
% Tobin Fricke 2007-10-26

% Experimental setup:
%                                [Dump]   
%                                  |
%  +-------+                       |
%  | Laser |-------|lambda/2|----|PBS|----[Power Meter]
%  +-------+ 
%  
... 53 more lines ...