40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Entry  Mon May 3 17:32:29 2021, Radhika, Summary, 2um Photodiodes, Updated PD testing schematic / measurement table QIL_PD_testing.graffleQIL_PD_testing.pdfScreen_Shot_2021-05-03_at_17.16.20.png
    Reply  Wed May 5 00:34:14 2021, rana, Summary, 2um Photodiodes, Updated PD testing schematic / measurement table 
       Reply  Mon May 10 15:38:36 2021, rana, Summary, 2um Photodiodes, Keithley connections Screen_Shot_2021-05-10_at_3.37.29_PM.png
Message ID: 2563     Entry time: Mon May 3 17:32:29 2021     Reply to this: 2564
Author: Radhika 
Type: Summary 
Category: 2um Photodiodes 
Subject: Updated PD testing schematic / measurement table 

Attached:

- Updated schematic of the current PD testing setup, including noise levels for current electronics

- Table of desired measurements for new setup, with expected signal levels, accuracy, and readout values

Attachment 1: QIL_PD_testing.graffle  177 kB  Uploaded Mon May 3 18:34:16 2021
Attachment 2: QIL_PD_testing.pdf  54 kB  Uploaded Mon May 3 18:34:29 2021  | Hide | Hide all
QIL_PD_testing.pdf
Attachment 3: Screen_Shot_2021-05-03_at_17.16.20.png  115 kB  Uploaded Mon May 3 18:34:54 2021  | Hide | Hide all
Screen_Shot_2021-05-03_at_17.16.20.png
ELOG V3.1.3-