Attached:

- Updated schematic of the current PD testing setup, including noise levels for current electronics

- Table of desired measurements for new setup, with expected signal levels, accuracy, and readout values

Attachment 1: QIL_PD_testing.graffle  177 kB  Uploaded Mon May 3 18:34:16 2021
Attachment 2: QIL_PD_testing.pdf  54 kB  Uploaded Mon May 3 18:34:29 2021  | Hide | Hide all
QIL_PD_testing.pdf
Attachment 3: Screen_Shot_2021-05-03_at_17.16.20.png  115 kB  Uploaded Mon May 3 18:34:54 2021  | Hide | Hide all
Screen_Shot_2021-05-03_at_17.16.20.png