40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Entry  Fri Nov 15 17:29:14 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0270.JPGIMG_0269.JPG
    Reply  Tue Nov 19 20:16:40 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0483.JPG
       Reply  Wed Nov 20 11:59:17 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
          Reply  Wed Nov 20 12:25:58 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
             Reply  Wed Nov 20 17:44:10 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab P_20191120_174034_vHDR_On.jpgP_20191120_174040_vHDR_On.jpg
                Reply  Thu Nov 21 21:45:10 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab DT02H_18_32PN.pdf
                   Reply  Fri Nov 22 13:21:26 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IMG_0497.JPGIMG_0498.JPG
                      Reply  Fri Nov 22 15:33:40 2019, Koji, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab P_20191122_150845_vHDR_On.jpg
                         Reply  Sat Nov 23 13:00:06 2019, Koji, Lab Infrastructure, Optics, Optical window transmission measurement optical_window_T.pdfP_20191122_183426_vHDR_On.jpgP_20191122_183436_vHDR_On.jpg
                         Reply  Tue Nov 26 15:36:59 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab IRLabsQIL.pdf
                            Reply  Wed Dec 4 13:54:04 2019, Raymond, Lab Infrastructure, General, Moved IR Labs cryostat into QIL from Cryo Lab 
Message ID: 2448     Entry time: Tue Nov 19 20:16:40 2019     In reply to: 2445     Reply to this: 2450
Author: Raymond 
Type: Lab Infrastructure 
Category: General 
Subject: Moved IR Labs cryostat into QIL from Cryo Lab 

The cold plate breadboard holes are indeed 4-40.

I've installed a new o-ring and vacuum valve, but I've scoured the labs for any piece that fits the open port on the side of the cryostat and have come up empty-handed. I've attached a photo with all of the IR labs input pieces found thus far (except duplicates or ones that match these same dimensions), none fit the drill pattern or counter sunk hole of the cryostat port. I tried but could not find mention of this specific port's removal in the elog history. 

Spent a while trying to make a Franken-stat from the innards and limbs of the other decommisioned IR lab cryostats but nothing allowed for a correct optical path. So I then started to make a custom port with a 122 o-ring and an old ISO blank flange, but I need a drill bit larger than 0.5" for the center electrical feedthrough and am having ID card issues accessing the student shop over in CES.

I will call IR labs tomorrow and see if they have an a standard piece for this feedthrough. 