Entry  Tue Aug 13 19:03:05 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer regulator.pdfNoise_across_Voltage_Regulator.pdfregulator.zip
    Reply  Thu Aug 15 08:03:13 2019, rana, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
       Reply  Thu Aug 15 08:36:29 2019, Shalika, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
    Reply  Fri Aug 30 05:11:11 2019, Chris, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 
Message ID: 2402     Entry time: Thu Aug 15 08:36:29 2019     In reply to: 2401
Author: Shalika 
Type: Noise Budget 
Category: 2micronLasers 
Subject: Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer 

I found only 1uF Tanatalum Capacitors in the EE shop. Maybe a a higher capacitance of tantalum capacitor will help. 

 

Another thing, is it good to compare the input referred noise for the different types of regulators? I did a comparison between the output noise only. 

Quote:
I'm glad to see that the voltage regulators can give good noise performance. I wish I understood what the gain peaking features came from - maybe the choice of capacitors?

 