Tue Aug 13 19:03:05 2019, Shalika Singh, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer  
|
Thu Aug 15 08:03:13 2019, rana, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer
|
Thu Aug 15 08:36:29 2019, Shalika, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer
|
Fri Aug 30 05:11:11 2019, Chris, Noise Budget, 2micronLasers, Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer
|
|
Message ID: 2401
Entry time: Thu Aug 15 08:03:13 2019
In reply to: 2396
Reply to this: 2402
|
Author: |
rana |
Type: |
Noise Budget |
Category: |
2micronLasers |
Subject: |
Noise Analysis of Voltage Regulator Circuit using SR785 Spectrum Analyzer |
|
|
I'm glad to see that the voltage regulators can give good noise performance. I wish I understood what the gain peaking features came from - maybe the choice of capacitors? |