Entry time: Thu Jan 24 19:43:53 2008
|
Author: |
Stefan |
Type: |
Electronics |
Category: |
ISS |
Subject: |
ISS servo work |
|
|
- Modified ISS: Bypassed differential driver & moved 2kHz pole to the first summing opamp.
- Installed an out-of-loop diode.
- Out-of-loop noise at 90Hz: ~8e-8 RIN/rtHz
Plot 1 shows the OLG.
The loop gain was set to 150kHz - just because I
didn't have the gain adjust hooked up.
Plot 2 shows the out-of-loop intesnity noise.
It is acoustic noise limited (except for the power lines). |
|
|
|
|