{ "cells": [ { "cell_type": "code", "execution_count": 31, "metadata": { "collapsed": false }, "outputs": [], "source": [ "import matplotlib #Import the plotting module\n", "import matplotlib.pyplot as plt #Neatly import under the name plt (this is tidier)\n", "import numpy as np # import numpy\n", "\n", "from pylab import * # Include the symbols in the pylab module to plot like its Matlab\n", "\n", "# matplotlib.rcParams.update({'font.size': 18, 'font.family': 'serif'}) # Configure font settings for size 18 and serif\n", "matplotlib.rcParams.update({'font.size': 18, 'font.family': 'STIXGeneral', 'mathtext.fontset': 'stix'}) # Configure font settings for size 18 and use the STIX family of fonts\n", "\n", "plt.close(\"all\") # Close all windows at start\n", "\n", "# Generates plots inline\n", "%matplotlib inline \n" ] }, { "cell_type": "code", "execution_count": 51, "metadata": { "collapsed": false }, "outputs": [], "source": [ "CurrentAW = np.array([0.0,5.0,10.0,15.0,20.0,25.0,30.0,35.0,40.0,45.0,50.0,55.0,60.0,65.0,70.0,75.0,80.0,85.0,90.0,95.0,100.0]);\n", "LaserOutputPowerAW = np.array([0,0.69e-6,2.7e-6,6.36e-6,32.83e-6,0.933e-3,1.836e-3,2.738e-3,3.64e-3,4.52e-3,5.39e-3,6.29e-3,7.18e-3,8.06e-3,8.92e-3,9.80e-3,10.67e-3,11.53e-3,12.40e-3,13.22e-3,14.08e-3])*1e3\n", "\n", "CurrentDmass = np.array([15,17,19,21,23,30,50,75,100,150,200,250,260,270,275,280,285,290,292,294,296,298,300,301.1])\n", "LaserOutputPowerDmass = np.array([0.006,0.010,0.174,0.236,0.614,1.82,5.20,9.30,13.3,21.3,28.9,36.0,37.6,39.12,39.9,40.5,41.2,41.8,42.0,42.25,42.5,42.7,42.90,43.02])\n" ] }, { "cell_type": "code", "execution_count": 53, "metadata": { "collapsed": false }, "outputs": [ { "data": { "image/png": "iVBORw0KGgoAAAANSUhEUgAAAZwAAAEjCAYAAAAG3beZAAAABHNCSVQICAgIfAhkiAAAAAlwSFlz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\n", "text/plain": [ "" ] }, "metadata": {}, "output_type": "display_data" } ], "source": [ "fig2 = plt.figure(1)\n", "ax = fig2.add_axes([0.1,0.1,0.8,0.8])\n", "ax.plot(CurrentAW,LaserOutputPowerAW,'b*-',label=r\"Recent test with 100 mA driver\",linewidth = 1) \n", "ax.plot(CurrentDmass,LaserOutputPowerDmass,'r*-',label = r\"Dmass's intital test in 2010 (Cryo_Lab:47)\",linewidth = 1) \n", "ax.legend(loc=2); # Put legend in the upper left corner\n", "ax.set_xlabel(r'Laser current $[mA]$')\n", "ax.set_ylabel(r'Output power [$mW$]')\n", "ax.set_title('Test of Emcore 1772 Current vs Output Power (First out of box 2010 and 2016)')\n", "fig2.savefig(\"plot20160811_Emcore1772_CurrentVsPower)_ThenAndNow.eps\")\n", "show()" ] }, { "cell_type": "code", "execution_count": null, "metadata": { "collapsed": true }, "outputs": [], "source": [] } ], "metadata": { "anaconda-cloud": {}, "kernelspec": { "display_name": "Python [Root]", "language": "python", "name": "Python [Root]" }, "language_info": { "codemirror_mode": { "name": "ipython", "version": 3 }, "file_extension": ".py", "mimetype": "text/x-python", "name": "python", "nbconvert_exporter": "python", "pygments_lexer": "ipython3", "version": "3.5.2" } }, "nbformat": 4, "nbformat_minor": 0 }