40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Entry  Wed Mar 30 14:12:10 2011, Alastair, Electronics, GYRO, Trans PD 100MHz_PD.pngPD_trans.fil.tar
    Reply  Thu Mar 31 00:33:36 2011, Frank, Electronics, GYRO, Trans PD 
       Reply  Thu Mar 31 11:25:43 2011, Alastair, Electronics, GYRO, Trans PD PD_trans.fil.tar
Message ID: 1367     Entry time: Thu Mar 31 00:33:36 2011     In reply to: 1365     Reply to this: 1368
Author: Frank 
Type: Electronics 
Category: GYRO 
Subject: Trans PD 

i tried to open the liso file but it seems to be empty

Quote:

I'm in the middle of stuffing the first Trans_PD at the moment.  I'm using the following values for the resonant notches:

  • AC coupling
    • L6=6.8uH
  • 100MHz notch
    • C2=22pF
    • C4=9pF(1.5-15pF tunable)
    • L3=82nH
  • 200MHz notch
    • C10=6.3pF(1.5-15pF tunable)
    • L2=100uH

You can compare these values to Zach's 33MHz diodes in this post.  The lower inductance of L3 gives a lower transimpedance and I've set the gain of the opamp to 2.

I have some concerns that we don't want to much gain for these PDs.  A total transimpedance of 30dB V/A means that 20mW of laser power becomes about 7dBm at the output of the PD.  If we're using a level 13 mixer then that seems about right.  If we want to increase the power at all then we will need to attenuate the output of the PD.

LISO file is attached

 

ELOG V3.1.3-