Author: Koji 
Type: Electronics 
Category: GYRO 
Subject: Universal PDH box noise problem identified 

Yes, I am happy about that. For the new box, we confirm the noise levels of the boxes with various gains before they are in use.

Quote:

Second, Koji will be pleased to hear that I think I have traced the excess low-frequency noise seen in this measurement to the AD8336 variable gain stage.

 

ELOG V3.1.3-