Wed Dec 15 15:41:45 2010, Alastair & Zach, Electronics, General, RFPD design
|
Wed Dec 15 22:29:27 2010, Frank, Electronics, General, RFPD design
|
Wed Dec 15 22:36:05 2010, Alastair, Electronics, General, RFPD design
|
Thu Dec 16 03:50:33 2010, rana, Electronics, General, RFPD design: comments
|
Thu Dec 16 15:27:12 2010, Alastair, Electronics, General, RFPD design: comments
|
Fri Dec 17 22:07:00 2010, Alastair, Electronics, General, RFPD design: comments
|
|
Message ID: 1219
Entry time: Wed Dec 15 22:29:27 2010
In reply to: 1216
Reply to this: 1220
|
Author: |
Frank |
Type: |
Electronics |
Category: |
General |
Subject: |
RFPD design |
|
|
you don't wanna have 4 power supplies to power the detector, way too complicated. I would change it to power the entire thing by +/-24V and regulate that to +/-15V. Then use the already regulated +/-15V to regulate it down to something else in addition.
|
Here is our layout for the RFPD in Altium. We are working on routing the board now.
|
|