Message ID: 1211     Entry time: Tue Dec 14 04:23:03 2010     In reply to: 1210     Reply to this: 1212
Author: rana 
Type: Laser 
Category: GYRO 
Subject: gyro signal noise comparison (AOM FB vs. PLL FB) 

I can't imagine any noise source that would be suppressed by the transmission PLL loop gain. In principle, we could

just use a frequency counter there instead of a loop and get the same information.

Since our incoming vacuum system doesn't suppress any noise in the IO or transmission, you might as well build a sealed

plastic box to encase the transmission to see if there's any effect. Of course, even better would be to

    FINISH THE RFPD ELECTRONICS DESIGN