40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  ATF eLog  Not logged in ELOG logo
Entry  Fri Oct 1 11:53:04 2010, Alastair, Computing, Computing, no chans in dataviewer 
    Reply  Fri Oct 1 12:28:53 2010, Alastair, Computing, Computing, no chans in dataviewer 
    Reply  Fri Oct 1 13:04:44 2010, Frank, Computing, Computing, no chans in dataviewer 
Message ID: 1097     Entry time: Fri Oct 1 13:04:44 2010     In reply to: 1095
Author: Frank 
Type: Computing 
Category: Computing 
Subject: no chans in dataviewer 

 again, FB1 has NOTHING to do with the realtime system. You will never be able to see channels from the RT system running on FB0 using FB1! It's technically impossible without some additional hardware which we don't have !

Don't touch the daqd on FB1, except when changing environmental monitoring channels or TCS channels !

If you restart FB1 almost any computer has to be restarted too as they share the directory mounted via NFS, not only the ones in the ATF lab ! So, plz, don't touch FB1.

Quote:

On FB1 the process daqd seems to be running okay, but we are not seeing any of our channels in dataviewer.  I tried a DAQ Reload, followed by FE Reset in the master MEDM screen - still nothing in dataviewer.  I used pkill daqd and checked the process had restarted - still nothing.  I rebooted fb1 and checked that the process daqd had restarted - still dataviewer cannot see any of our channels.  I don't see any problems with daqd, it appears to be running and restarting as it should.  daqconfig shows we are set to acquire channels.