[ops@ws1 ~]$ /sbin/lspci -v
00:00.0 Memory controller: nVidia Corporation CK804 Memory Controller (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0
Capabilities: <access denied>
00:01.0 ISA bridge: nVidia Corporation CK804 ISA Bridge (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0
I/O ports at 8c00 [size=1K]
00:01.1 SMBus: nVidia Corporation CK804 SMBus (rev a2)
Subsystem: Tyan Computer Unknown device 2895
Flags: 66MHz, fast devsel
I/O ports at 1000 [size=32]
I/O ports at a000 [size=64]
I/O ports at a040 [size=64]
Capabilities: <access denied>
00:02.0 USB Controller: nVidia Corporation CK804 USB Controller (rev a2) (prog-if 10 [OHCI])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 209
Memory at b0000000 (32-bit, non-prefetchable) [size=4K]
Capabilities: <access denied>
00:02.1 USB Controller: nVidia Corporation CK804 USB Controller (rev a3) (prog-if 20 [EHCI])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 201
Memory at b0001000 (32-bit, non-prefetchable) [size=256]
Capabilities: <access denied>
00:04.0 Multimedia audio controller: nVidia Corporation CK804 AC'97 Audio Controller (rev a2)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 209
I/O ports at 1800 [size=256]
I/O ports at 1400 [size=256]
Memory at b0002000 (32-bit, non-prefetchable) [size=4K]
Capabilities: <access denied>
00:06.0 IDE interface: nVidia Corporation CK804 IDE (rev f2) (prog-if 8a [Master SecP PriP])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0
I/O ports at 1c00 [size=16]
Capabilities: <access denied>
00:07.0 IDE interface: nVidia Corporation CK804 Serial ATA Controller (rev f3) (prog-if 85 [Master SecO PriO])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 217
I/O ports at 1c40 [size=8]
I/O ports at 1c34 [size=4]
I/O ports at 1c38 [size=8]
I/O ports at 1c30 [size=4]
I/O ports at 1c10 [size=16]
Memory at b0003000 (32-bit, non-prefetchable) [size=4K]
Capabilities: <access denied>
00:08.0 IDE interface: nVidia Corporation CK804 Serial ATA Controller (rev f3) (prog-if 85 [Master SecO PriO])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 225
I/O ports at 1c58 [size=8]
I/O ports at 1c4c [size=4]
I/O ports at 1c50 [size=8]
I/O ports at 1c48 [size=4]
I/O ports at 1c20 [size=16]
Memory at b0004000 (32-bit, non-prefetchable) [size=4K]
Capabilities: <access denied>
00:09.0 PCI bridge: nVidia Corporation CK804 PCI Bridge (rev a2) (prog-if 01 [Subtractive decode])
Flags: bus master, 66MHz, fast devsel, latency 0
Bus: primary=00, secondary=01, subordinate=01, sec-latency=64
Memory behind bridge: b0100000-b01fffff
00:0a.0 Bridge: nVidia Corporation CK804 Ethernet Controller (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 201
Memory at b0005000 (32-bit, non-prefetchable) [size=4K]
I/O ports at 1c60 [size=8]
Capabilities: <access denied>
00:0e.0 PCI bridge: nVidia Corporation CK804 PCIE Bridge (rev a3) (prog-if 00 [Normal decode])
Flags: bus master, fast devsel, latency 0
Bus: primary=00, secondary=02, subordinate=02, sec-latency=0
I/O behind bridge: 00002000-00002fff
Memory behind bridge: b1000000-b2ffffff
Prefetchable memory behind bridge: 00000000c0000000-00000000cff00000
Capabilities: <access denied>
00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration
Flags: fast devsel
Capabilities: <access denied>
00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map
Flags: fast devsel
00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller
Flags: fast devsel
00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control
Flags: fast devsel
00:19.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration
Flags: fast devsel
Capabilities: <access denied>
00:19.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map
Flags: fast devsel
00:19.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller
Flags: fast devsel
00:19.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control
Flags: fast devsel
01:05.0 FireWire (IEEE 1394): Texas Instruments TSB43AB22/A IEEE-1394a-2000 Controller (PHY/Link) (prog-if 10 [OHCI])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, medium devsel, latency 64, IRQ 11
Memory at b0104000 (32-bit, non-prefetchable) [size=2K]
Memory at b0100000 (32-bit, non-prefetchable) [size=16K]
Capabilities: <access denied>
02:00.0 VGA compatible controller: nVidia Corporation G73 [GeForce 7600 GT] (rev a1) (prog-if 00 [VGA controller])
Subsystem: ASUSTeK Computer Inc. Unknown device 820d
Flags: bus master, fast devsel, latency 0, IRQ 50
Memory at b2000000 (32-bit, non-prefetchable) [size=16M]
Memory at c0000000 (64-bit, prefetchable) [size=256M]
Memory at b1000000 (64-bit, non-prefetchable) [size=16M]
I/O ports at 2000 [size=128]
Capabilities: <access denied>
08:0a.0 PCI bridge: Advanced Micro Devices [AMD] AMD-8131 PCI-X Bridge (rev 12) (prog-if 00 [Normal decode])
Flags: bus master, 66MHz, medium devsel, latency 64
Bus: primary=08, secondary=09, subordinate=09, sec-latency=0
Capabilities: <access denied>
08:0a.1 PIC: Advanced Micro Devices [AMD] AMD-8131 PCI-X IOAPIC (rev 01) (prog-if 10 [IO-APIC])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, medium devsel, latency 0
Memory at d0000000 (64-bit, non-prefetchable) [size=4K]
08:0b.0 PCI bridge: Advanced Micro Devices [AMD] AMD-8131 PCI-X Bridge (rev 12) (prog-if 00 [Normal decode])
Flags: bus master, 66MHz, medium devsel, latency 64
Bus: primary=08, secondary=0a, subordinate=0a, sec-latency=0
Capabilities: <access denied>
08:0b.1 PIC: Advanced Micro Devices [AMD] AMD-8131 PCI-X IOAPIC (rev 01) (prog-if 10 [IO-APIC])
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, medium devsel, latency 0
Memory at d0001000 (64-bit, non-prefetchable) [size=4K]
80:00.0 Memory controller: nVidia Corporation CK804 Memory Controller (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0
Capabilities: <access denied>
80:01.0 Memory controller: nVidia Corporation CK804 Memory Controller (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0
Memory at d0400000 (32-bit, non-prefetchable) [size=4K]
80:0a.0 Bridge: nVidia Corporation CK804 Ethernet Controller (rev a3)
Subsystem: Tyan Computer Unknown device 2895
Flags: bus master, 66MHz, fast devsel, latency 0, IRQ 233
Memory at d0401000 (32-bit, non-prefetchable) [size=4K]
I/O ports at 3000 [size=8]
Capabilities: <access denied>
80:0e.0 PCI bridge: nVidia Corporation CK804 PCIE Bridge (rev a3) (prog-if 00 [Normal decode])
Flags: bus master, fast devsel, latency 0
Bus: primary=80, secondary=81, subordinate=81, sec-latency=0
Capabilities: <access denied> |