Mon Dec 31 03:11:45 2012, Koji, Optics, Characterization, Further more RoC measurement
|
Wed Jan 2 07:35:55 2013, Koji, Optics, Characterization, Thickness of a curved mirror
|
Wed Jan 2 07:45:39 2013, Koji, Optics, Characterization, First Contact test 
| +
Thu Jan 10 18:37:50 2013, Koji, Optics, Characterization, Wedging of the PZTs
|
Wed Jan 16 14:10:50 2013, Koji, Optics, Characterization, Autocollimator tests of optics perpendicularity/parallelism
|
Fri Jan 18 13:25:17 2013, Koji, Optics, Configuration, Autocollimator calibration
|
Sat Jan 19 20:47:41 2013, Koji, Optics, Characterization, Wedge measurement with the autocollimator
| +
Mon Feb 4 00:39:08 2013, Koji, Optics, Characterization, Wedge measurement with the autocollimator and the rotation stage
| +
Wed Feb 6 02:34:10 2013, Koji, Optics, Characterization, Wedge measurement with the autocollimator and the rotation stage
|
Thu Feb 7 23:01:45 2013, Koji, Optics, Characterization, UV epoxy gluing test
| +
Thu Feb 21 18:44:18 2013, Koji, Optics, Configuration, Perpendicularity test 
| +
Wed Feb 27 18:18:48 2013, Koji, Optics, Configuration, More perpendicularity test
| +
Fri Mar 1 23:06:15 2013, Koji, Optics, Configuration, More perpendicularity test final
| +
Fri Mar 1 23:52:18 2013, Koji, Optics, Characterization, Wedge measurement with the autocollimator and the rotation stage
| +
Tue Mar 5 19:37:00 2013, Zach, Optics, Characterization, eLIGO OMC visibility vs. power measurement details
| +
Wed Mar 6 23:24:58 2013, Zach, Optics, Characterization, eLIGO OMC visibility vs. power measurement details   
|
Wed Mar 20 09:38:02 2013, Zach, Optics, Characterization, [LLO] OMC test bench modified
|
Sat Mar 23 02:41:00 2013, Koji, Optics, General, Black glass beam dumps for the first OMC  
|
Sat Mar 23 13:34:14 2013, Koji, Optics, General, PZT assembly prototype glued   
|
Mon Mar 25 19:31:16 2013, Koji, Optics, General, OMC Top-side gluing   
| +
Thu Mar 28 03:37:07 2013, Zach, Optics, Configuration, Test setup input optics progress  
| +
Fri Mar 29 08:55:00 2013, Zach, Optics, Configuration, Beam launched into fiber
|
Mon Apr 1 03:13:41 2013, Koji, Optics, General, Failure of PZT-glass joints
|
Mon Apr 1 03:23:48 2013, Koji, Optics, General, UV power calibration
|
Mon Apr 1 18:17:01 2013, Koji, Optics, General, Mirror curvature center test 6x
|
Wed Apr 3 18:42:45 2013, Koji, Optics, General, EP30-2 gluing test
|
Thu Apr 4 00:35:42 2013, Zach, Optics, Configuration, MMT installed on breadboard, periscope built
|
Thu Apr 4 01:35:04 2013, Koji, Optics, Characterization, Mode matching to the OMC cavity
| +
Thu Apr 4 01:43:06 2013, Koji, Optics, Characterization, Mirror T measurement
| +
Thu Apr 4 23:44:52 2013, Koji, Optics, Configuration, Beam launched into fiber
| +
Fri Apr 5 18:18:36 2013, Zach, Optics, Configuration, AOM probably broken
| +
Mon Apr 8 11:11:37 2013, Koji, Optics, Characterization, More Mirror T measurement
|
Mon Apr 8 11:29:08 2013, Koji, Optics, Characterization, Mirror/PZT Characterization links
|
Mon Apr 8 20:56:52 2013, Koji, Optics, Configuration, PZT & Curverd Mirror arrangement
| +
Mon Apr 8 21:11:14 2013, Koji, Optics, General, PZT assembly gluing
|
Mon Apr 8 23:42:33 2013, Koji, Optics, Configuration, Fake OMC roughly aligned 
| +
Tue Apr 9 13:56:09 2013, Koji, Optics, General, PZT assembly post gluing / pre baking pictures
|
Wed Apr 10 00:40:30 2013, Zach, Optics, Configuration, fauxMC locked
|
Fri Apr 12 09:25:31 2013, Koji, Optics, Characterization, Alignment of the OMC (without glue)
|
Sat Apr 13 21:06:02 2013, Koji, Optics, General, OMC Bottom-side: cavity glued 
|
Tue Apr 16 00:40:45 2013, Koji, Optics, General, PD/QPD path gluing ~ preparation
| +
Tue Apr 16 08:12:14 2013, Koji, Optics, Characterization, Further More Mirror T measurement
| +
Tue Apr 16 09:43:58 2013, Koji, Optics, Configuration, Mirror list for L1OMC
| +
Tue Apr 16 23:26:51 2013, Koji, Optics, Characterization, Further More Mirror T measurement
|
Wed Apr 17 07:30:04 2013, Koji, Optics, General, QPD path glued
| +
Mon May 6 19:31:51 2013, Koji, Optics, Characterization, Spot position measurement on the diode mounts   
| +
Wed May 8 15:08:57 2013, Koji, Optics, Characterization, Spot position measurement on the diode mounts   
| +
Thu May 30 15:00:28 2013, Koji, Optics, General, QPD alignment
| +
Fri May 31 05:46:54 2013, Koji, Optics, General, QPD alignment  
|
Fri May 31 14:07:54 2013, Koji, Optics, Characterization, Transverse Mode Spacing measurement afte the baking 
|
|