40m
QIL
Cryo_Lab
CTN
SUS_Lab
CAML
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
OMC elog, Page 13 of 13
Not logged in
List
|
Find
|
Login
|
Help
New entries since:
Wed Dec 31 16:00:00 1969
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
General
Facility
Clean
Supply
Mechanics
Optics
Electronics
621 Entries
Goto page
Previous
1
,
2
,
3
...
11
,
12
, 13
ID
Date
Author
Type
Category
Subject
Text
611
Mon Aug 21 15:02:32 2023
Koji
Optics
General
cavity realignment and new power measurements
This is WOW!
Excellent mode matching work.
The measurement is still
612
Mon Aug 21 16:05:07 2023
Camille Makarem
Optics
Characterization
cavity realignment and new power measurements
Thanks for clarifying that. We will repeat
some power measurements and check the output
offset voltage to the laser.
613
Mon Aug 21 16:15:09 2023
Koji
Optics
Characterization
cavity realignment and new power measurements
You should proceed to the next steps. You'll
need to repeat the power measurements before
the bonding. Next time, the measurement procedure
614
Tue Aug 22 10:25:10 2023
Thejas
Optics
Characterization
cavity realignment and new power measurements
Thanks Koji, we did observe this discrepency
and thought that the code normalizes the
power/voltage readings to the reference power
616
Wed Aug 23 07:48:14 2023
Camille Makarem, Tejas
Optics
Characterization
FSR and TMS measuarement of A+ build
[Camille, Thejas]
22 August 2023
617
Thu Aug 24 12:30:58 2023
Camille Makarem, Thejas
Optics
Characterization
FSR and TMS analysis
Attached are the analysis results from
the measurements in 616.
FSR: 264.657354 +/- 0.003444 MHz
618
Thu Aug 24 16:09:46 2023
Camille Makarem
Optics
General
PZT length-to-angle coupling
[Camille, Thejas]
We checked the length-to-angle coupling
621
Wed Aug 30 12:38:52 2023
Thejas
Optics
General
A+ OMC #1: HOM spectrum
Examination into bonding template confimred
the limitation of space available to
change cavity length by at least 10 mm to
623
Mon Sep 18 15:08:26 2023
Thejas
Optics
General
OMC HEPA enclosure filter fan speed
I went in lab today and turned the HEPA
filter (clsoe to the entrance) to high since
we are not doing any measurements at the
624
Mon Sep 18 15:09:55 2023
Thejas
Optics
CAvity Bonding
Piezo inertial micromaters
New piezo actuated micrometers from thorlabs
arrived last week.
4 x MPIA10
18
Tue Aug 14 03:29:06 2012
Koji
Supply
General
Clean supply rack
Clean supplies & some cleaning tools
are located at the right side of the entrance.
The file cabinet there was moved to
123
Fri May 10 09:33:22 2013
Koji
Supply
General
COMSOL simulation on the glass bracket stress
274
Thu Jan 19 20:57:53 2017
Koji
Supply
General
Purchase
Ordered:
Office Depot
v AA battery Qty. 24
275
Thu Feb 16 17:23:12 2017
Koji
Supply
General
Purchase
BNC Patch Panel
8x
Amphenol Connex 112443 / Isolated BNC FEMALE
TO FEMALE BULKHEAD ISOLATED ADAPTER - 50
321
Thu Apr 4 20:07:39 2019
Koji
Supply
General
Purchase
== Office Depot ==
Really
Useful Box 9L x 6 (delivered)
375
Wed Sep 18 22:30:11 2019
Stephen
Supply
General
EP30-2 Location and Status
Here is a summary of the events of the
last week, as they relate to EP30-2.
1) I lost the EP30-2 syringes that
376
Wed Sep 18 23:16:06 2019
Stephen
Supply
General
Items staged at 40m Bake Lab for PZT Subassembly Bonding
The following items are presently staged
at the 40m Bake Lab (see photo indicating
current location) (noting items broght by
384
Tue Oct 22 11:56:09 2019
Stephen
Supply
General
Epoxy Status update as of 22 October 2019
The following is the current status of
the epoxies used in assembly of the OMC (excerpt
from C1900052)
407
Fri Feb 5 07:40:37 2021
Stephen
Supply
General
OMC Unit 4 Build Machined Parts
OMC Unit 4 Build Machined Parts are currently
located in Stephen's office. See image
of large blue box from office, below.
411
Wed Jul 7 14:21:50 2021
Stephen
Supply
General
OMC Unit 4 Build Machined Parts
More explicit insights into the inventory
for the Unit 4 build. Image of inventory
included below.
453
Fri Nov 11 19:07:48 2022
Koji
Supply
General
Supply Order
Clean Supply Ordered
TexWipe TX8410 AlphaSat
Vectra Alpha 10 50 sheets x 12 pk (VWR
Goto page
Previous
1
,
2
,
3
...
11
,
12
, 13
ELOG V3.1.3-