Subject: OMC #002 delamination check 2 

More epoxy delamination check:

DCPD R (Attachment 1): Found half delaminated

DCPD T (Attachment 2): Found half delaminated

QPD1/QPD2 (Attachment 3): Looks fine

------

In total we need to fix bonding of three invar bases (including the one for the cable bracket)

Attachment 1: IMG_1106.JPG  1.858 MB  Uploaded Tue Jul 26 01:11:49 2022  | Hide | Hide all | Show all
IMG_1106.JPG
Attachment 2: IMG_1107.JPG  267 kB  Uploaded Tue Jul 26 01:11:58 2022  | Hide | Hide all | Show all
IMG_1107.JPG
Attachment 3: IMG_1110.JPG  2.849 MB  Uploaded Tue Jul 26 01:12:01 2022  | Show | Hide all | Show all