40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  OMC elog  Not logged in ELOG logo
Entry  Fri Jul 15 22:14:14 2022, Koji, General, General, OMC Lab recovery for the OMC #002 test PXL_20220716_035922673.jpgPXL_20220716_025319391.MP.jpgPXL_20220716_025334324.jpgPXL_20220716_035309066.jpgPXL_20220716_035411435.NIGHT.jpg
    Reply  Tue Jul 26 00:01:59 2022, Koji, General, General, OMC #002 delamination check 2 IMG_1106.JPGIMG_1107.JPGIMG_1110.JPG
Message ID: 426     Entry time: Tue Jul 26 00:01:59 2022     In reply to: 414
Author: Koji 
Type: General 
Category: General 
Subject: OMC #002 delamination check 2 

More epoxy delamination check:

DCPD R (Attachment 1): Found half delaminated

DCPD T (Attachment 2): Found half delaminated

QPD1/QPD2 (Attachment 3): Looks fine

------

In total we need to fix bonding of three invar bases (including the one for the cable bracket)

Attachment 1: IMG_1106.JPG  1.858 MB  Uploaded Tue Jul 26 01:11:49 2022  | Show | Hide all | Show all
Attachment 2: IMG_1107.JPG  267 kB  Uploaded Tue Jul 26 01:11:58 2022  | Hide | Hide all | Show all
IMG_1107.JPG
Attachment 3: IMG_1110.JPG  2.849 MB  Uploaded Tue Jul 26 01:12:01 2022  | Hide | Hide all | Show all
IMG_1110.JPG
ELOG V3.1.3-