Entry  Sun Apr 14 23:58:49 2019, Koji, General, General, OMC(004): PZT sub-assembly post air-bake inspection 
    Reply  Mon Apr 15 00:08:32 2019, Koji, General, General, OMC(004): PZT sub-assembly post air-bake inspection (Sub-assy #7) 6x
    Reply  Mon Apr 15 00:39:04 2019, Koji, General, General, OMC(004): PZT sub-assembly post air-bake inspection (Sub-assy #8) 8x
    Reply  Mon Apr 15 01:07:30 2019, Koji, General, General, OMC(004): PZT sub-assembly post air-bake inspection (Sub-assy #9) 7x
    Reply  Mon Apr 15 01:23:45 2019, Koji, General, General, OMC(004): PZT sub-assembly post air-bake inspection (Sub-assy #10)  IMG_7589.jpgIMG_7590.jpgIMG_7591.jpgIMG_7592.jpg
Message ID: 334     Entry time: Mon Apr 15 01:07:30 2019     In reply to: 331
Author: Koji 
Type: General 
Category: General 
Subject: OMC(004): PZT sub-assembly post air-bake inspection (Sub-assy #9) 

Sub-ASSY #9

The most fractured unit among four.

Attachment #1: Mounting Block SN017

Attachment #2: Two large removals well visbile. The bottom right corener was chipped.

Attachment #3: Another view of the chipping.

Attachment #4: PZT-mounting block bonding look very good.

Attachment #5: Another view of the PZT-mounting block bonding. Looks very good too.

Attachment #6: Fractures bonded on the fixture.

Attachment #7: Front view. The mirror-PZT bonding look just fine.

 

Attachment 1: IMG_7594.jpg  783 kB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7594.jpg
Attachment 2: IMG_7595.jpg  885 kB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7595.jpg
Attachment 3: IMG_7596.jpg  770 kB  Uploaded Mon Apr 15 02:19:33 2019  | Show | Hide all | Show all
Attachment 4: IMG_7597.jpg  838 kB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7597.jpg
Attachment 5: IMG_7598.jpg  840 kB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7598.jpg
Attachment 6: IMG_7600.jpg  1.460 MB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7600.jpg
Attachment 7: IMG_7618.jpg  416 kB  Uploaded Mon Apr 15 02:19:33 2019  | Hide | Hide all | Show all
IMG_7618.jpg
ELOG V3.1.3-