Entry  Sat Mar 26 17:39:50 2016, Koji, Electronics, Characterization, HQEPD dark noise PD_dark_current.pdf
    Reply  Sat Mar 26 18:22:24 2016, Koji, Electronics, Characterization, Baking / Contamination tests of the PDs 
       Reply  Tue Apr 5 18:22:40 2016, Koji, Electronics, Characterization, Baking / Contamination tests of the PDs QE_after_air_bake.pdf
          Reply  Tue Apr 5 21:20:15 2016, Koji, Electronics, Characterization, More dark noise measurement PD_dark_current.pdf
Message ID: 260     Entry time: Tue Apr 5 21:20:15 2016     In reply to: 259
Author: Koji 
Type: Electronics 
Category: Characterization 
Subject: More dark noise measurement 

All survived PDs have been measured.

Attachment 1: PD_dark_current.pdf  1.924 MB  Uploaded Tue Apr 5 22:20:40 2016  | Show | Show all