    Reply  Fri Oct 1 11:52:06 2021, Paco, General, Design specs, HR coating emissivity ETM_210409_120913_emissivity.pdfinterpolated_n_k.pdf
[Paco, Nina, Aidan]

Updated the stack emissivity code to use the Kitamura paper fused silica dispersion which has a prominent 20 um absorption peak which wasn't
there before... (data was up to 15 um, and extrapolated smoothly beyond). The updated HR stack emissivities are in Attachments #1 - #2. A weird feature
Entry  Fri Oct 1 12:01:24 2021, Paco, General, Design specs, TM Barrel coating emissivity stack_1.pdfstack_2.pdfstack_3.pdfinterpolated_n_k.pdf
[Paco, Nina, Aidan]

We ran our stack emissivity calculation on different AR stacks to try and make a decision for the TM barrel coatings. This code has yet to be
validated by cross checking against tmm as suggested by Chris. The proposed layer structures by Aidan and Nina are:
    Reply  Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity stack_1.pdfstack_2.pdfstack_3.pdf
Agree with this. Quickly running tmm on the same "stacks" gave the Attachment
#1-3. (Ignore the vertical axis units... will post corrected plots) and extend the wavelength range to 100 um.
Entry  Fri Nov 5 11:51:50 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um HITRAN_line_strenghts.pdfbroadened_spectrum.pdfPP_broadened_spectrum.pdf
[Paco]

I used the HITRAN database to download the set of ro-vibrational absorption lines of CO2 (carbon dioxide) near 2.05 um. The lines are plotted
for reference vs wavenumber in inverse cm in Attachment #1.
    Reply  Tue Nov 16 11:47:54 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um PP_broadened_spectrum.pdf
[Paco]

There was an error in the last plot of the previous log. This was correctly pointed out by rana's pointing out that the broadening from air
should be independent of the CO2 concentration, so nominally both curves should coincide with each other. Nevertheless, this doesn't affect the earlier
Entry  Mon Jul 18 18:34:29 2022, Paco, General, Design specs, HR coating update ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf
I've been running the HR coating optimization for mariner TMs. Relative to the specifications found here
we now are aiming for


ITM HR coating of 2000 ppm @ 2050.15 nm, and 1000 ppm @ 1550 nm
ETM HR coating of 25 ppm @ 2050.15 nm, and 1000 ppm @ 1550
    Reply  Fri Jul 22 13:36:55 2022, Paco, General, Design specs, HR coating update ETM_corner.pdfITM_corner.pdf
Here are some corner plots to analyze the sensitivity of the designs in the previous elog
to a 1% gaussian distributed perturbation using MCMC.

Attachment #1 shows the ETM corner plot  
Entry  Fri Sep 24 13:12:00 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps 
*Note: the current modeling script can be found at: CryoEngineering/MarinerCooldownEstimation.ipynb

Nina pointed me to the current mariner cooldown estimation script (path above) and we have since met a few times to discuss upgrades/changes.
Nina's hand calculations were mostly consistent with the existing model, so minimal changes were necessary. The material properties and geometric
    Reply  Wed Sep 29 16:15:19 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps Heat_Load_Sketch_geometry.pdfHeat_Load_Sketch_diagram.pdfheating_cooling_P_vs_T.pdfCooldownTM_radiative.pdf
Attachment 1 is a geometric diagram that reflects the current state of the ITM cooldown model, introduced in [30].
The inner shield is assumed to be held at 77K for simplicity, and 2 heat sources are considered: laser heating, and radiative heating from the room-temperature
snout opening. The view factor Fij between the snout opening and test mass (modeled as 2 coaxial parallel discs separated by length L -
    Reply  Tue Oct 5 17:46:14 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps Heat_Load_Sketch_all.pdfVaryingISA.pdfCooldownTM.pdf
Building on [32], I added a copper cold finger to conductively cool the inner shield, instead
of holding the inner shield fixed at 77K. The cold finger draws cooling power from a cyro cooler or "cold bath" held at 60K, for simplicity.
I added an outer shield and set its temperature to 100K. The outer shield supplies some radiative heating to the inner shield, but blocks out 295K heating,
    Reply  Fri Oct 15 13:45:55 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps VaryingTMl.pdf
I used the same model in [37] to consider how test mass length affects the cooldown. Attachment
1 plots the curves for TM length=100mm and 150mm. The coupling between the test mass and inner shield is proportional to the area of the test mass, and
therefore increases with increasing length. Choosing l=100mm (compared to 150mm) thus reduces the radiative cooling of the test mass. The cooldown time
    Reply  Fri Oct 15 14:31:15 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps VaryingISA.pdfVaryingTMl.pdf
I reran the cooldown model, setting the emissivity of the inner surface of the inner shield to 0.7 (coating), and the emissivity of the outer surface
to 0.03 (polished Al). Previously, the value for both surfaces was set to 0.3 (rough aluminum). 

Attachment 1: TM cooldown, varying area of the inner shield. Now, the marginal improvement in cooldown once the IS area reaches 0.22 m2 is
Entry  Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example Heat_Load_Sketch.pdf
Attached is a cartoon partial view into the heat load experienced by the Mariner assembly.

The omnigraffle file with more explicit arrow labelling in the 'layers' tab is available here.
The dashed red lines along to top represent vacuum chamber radiation incident on all sides of the OS/IS, not just from the top. Off picture to the right
Entry  Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources 
Ongoing points of updates/content (list to be maintained and added)
Mariner Chat Channel
Mariner Git Repository 
Entry  Fri Mar 5 11:05:13 2021, Stephen, General, Design specs, Feasibility of 6" optic size in CAD 4in_from_20210305_easm.png6in_from_20210305_easm.png
6" vs 4" optic size comparison using CAD - worth hopping into the 3D geometry using the link below, but also posting a couple of images below.

1) We can adjust all parameters relating to the suspension frame except the beam height. Is there enough clearance under the optic for the internal
shield?
Entry  Fri May 7 09:57:18 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept mariner_suspension_test_chamber_concept.jpg
Koji, Stephen

Putting together Koji's design work with Stephen's CAD, we consider the size of a test chamber for the Mariner suspension.

Koji's design uses a 6" x 6" Si optic, with an overall height of about 21.5".
Entry  Wed Jun 30 16:21:53 2021, Stephen, General, Design specs,  
[Stephen, Koji]

WIP - check layout of 60 cm suspension in chamber at 40m, will report here

WIP - also communicate the
    Reply  Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept 
WIP - Stephen to check on new suspension dimensions and fit into 40m chamber
Entry  Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame no_sos_cad_screenshot.pngvault_check_in_of_mariner_suspension_cad.png
[Koji, Stephen]

Kind of a silly post, and not very scientific, but we are sticking to it. During our check in today we discussed Mariner suspension frame design
concept, and we chose to proceed with MOS-style (4 posts, rectangular footprint).
Entry  Mon Oct 11 15:22:18 2021, Yehonathan, General, General, Microcomb alternatives ELMO_specs.pngHNLF_specs.pngSimulationResults1.pngSimulationResults3.png
Following our discussion at the Friday JC meeting, I gathered several resources and made a small simulation to show how frequency combs might be generated
on platforms other than microcombs or mode-locked lasers.

Indeed, frequency combs generated directly from a mode-locked laser are expensive as they require ultra-broadband operation (emitting few fs
    Reply  Wed Mar 17 21:24:27 2021, gautam, General, Design specs, Silicon TM dichroic coatings for phase I 
I guess you have tried it already - but does enforcing the stacks to be repeating bilayer pairs of the same thickness fail miserably? When doing
this for the PR3 optic @1064nm, I found that the performance of a coating in which the layers are repeating bilayers (so only 2 thicknesses + the cap and
end are allowed to vary) was not that much worse than the one in which all 38 thicknesses were allowed to vary arbitrarily. Although you are aiming for
    Reply  Mon Sep 27 17:01:53 2021, rana, General, Heat Load, Mariner cooldown model status + next steps 
How about a diagram so that we can understand
what this model includes?
    Reply  Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 


cool
Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
For our optical contacting, Jennifer and I are starting out with glass (microscope slides), with the setup in the EE shop next to the drill press (photos
from Jennifer to follow).

Some interesting links: