40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, Page 2 of 2  Not logged in ELOG logo
Entry  Thu May 5 19:56:25 2022, Koji, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 40m_Mariner_Suspension-0062.png40m_Mariner_Suspension.mp4
    Reply  Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 
Entry  Thu Jun 16 14:04:30 2022, Juan, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 16 19:43:36 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 23 21:11:03 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
Entry  Mon Jun 27 08:22:22 2022, Juan, General, General, General Update/ Need to do task coildrive.jpg
Entry  Sat Jul 2 09:22:39 2022, Juan , General, General, Progress update  IMG-5220.jpg
Entry  Tue Jul 5 21:06:47 2022, Juan, General, General, Work Update  IMG-5362.jpgIMG-5361.jpg
Entry  Thu Jul 7 10:23:04 2022, Juan, General, General, Update  IMG-5378.jpgIMG-5379.jpg
Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
Entry  Fri Jul 8 17:09:10 2022, Juan, General, General, Coil Driver and Sat Amp IMG-5434.jpgIMG-5421.jpgIMG-5420.jpg
Entry  Mon Jul 11 16:24:31 2022, Jennifer Hritz, General, Optical Contacting, Baselining the temperature output of the Oster hot plate PXL_20220708_230038748.jpgPXL_20220708_230234841.MP.jpg
Entry  Mon Jul 11 17:27:39 2022, Jennifer Hritz, General, Optical Contacting, First successful bond PXL_20220712_223449788.MP.jpg
Entry  Mon Jul 11 17:39:17 2022, Juan, General, General, Coil driver chassis  IMG-5493.jpgIMG-5494.jpg
Entry  Wed Jul 13 13:16:33 2022, Juan, General, General, Finished coil driver and sat amp  IMG-5553.jpg
Entry  Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg
Entry  Mon Jul 18 18:34:29 2022, Paco, General, Design specs, HR coating update ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf
    Reply  Fri Jul 22 13:36:55 2022, Paco, General, Design specs, HR coating update ETM_corner.pdfITM_corner.pdf
Entry  Fri Jul 22 13:47:47 2022, Juan, General, General, Update 
Entry  Tue Jul 26 14:17:44 2022, Juan, General, General, OSEMS actuators  8x
Entry  Wed Jul 27 14:50:20 2022, Jennifer Hritz, General, Optical Contacting, Bonding without liquids and narrowing down heating issue PXL_20220727_214658230.jpgPXL_20220727_214241668.mp4
Entry  Thu Aug 4 11:26:55 2022, Juan, General, General, Sat Amp IMG-6153.jpg
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
Entry  Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS OSEMs.xlsx
Entry  Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png
    Reply  Tue Aug 16 09:58:23 2022, Paco, General, Design specs, HR coating update 6x
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
    Reply  Tue Aug 23 17:10:50 2022, Paco, General, Design specs, New corner plots ITM_corner.pdfETM_corner.pdf
Entry  Fri Aug 26 14:24:57 2022, Radhika, General, Heat Load, Mariner TM Cooldown model 6x
    Reply  Mon Aug 29 15:44:46 2022, Radhika, General, Heat Load, Mariner TM Cooldown model VaryingSnoutparams.pdfMarinerTMCooldown_snout_optimal.pdf
    Reply  Wed Sep 7 10:42:12 2022, Radhika, General, Heat Load, Mariner TM Cooldown model SnoutLengthCooldownTM.pdf
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Wed Sep 28 22:11:31 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides thor_lab_slides_first_bond_PXL_20220929_045352675.MP.jpgthor_lab_slides_after_attempting_to_expand_bond_area_PXL_20220929_045510075.MP.jpg
Entry  Thu Sep 29 18:36:40 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides (continued) before_heat_PXL_20220930_011031420.MP.jpgset_up_PXL_20220930_011050114.MP.jpgright_after_heating_PXL_20220930_014301900.MP.jpgafter_4ish_hours_of_cooling_PXL_20220930_063533904.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Sat Oct 1 23:00:03 2022, Jennifer Hritz, General, Optical Contacting, (RESULTS!) Quick test heat and pressure test samples_before_AND_after_pressure_PXL_20221002_054158446.MP.jpgsamples_before_AND_after_heat_w_pressure_PXL_20221002_053842185.MP.jpg
ELOG V3.1.3-