Thu May 21 11:51:44 2020, Koji, General, General, Mariner Elog Test
|
Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources
|
Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example
|
Fri Mar 5 11:05:13 2021, Stephen, General, Design specs, Feasibility of 6" optic size in CAD 
|
Fri Apr 23 10:41:22 2021, Aidan, General, Design specs, 2 um photodiode requirements
|
Tue Apr 27 12:28:43 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 
|
Fri May 7 17:50:31 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 update   
|
Thu Mar 4 17:04:52 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I 
|
Wed Mar 17 19:51:42 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I  
|
Wed Mar 17 21:24:27 2021, gautam, General, Design specs, Silicon TM dichroic coatings for phase I
|
Wed Mar 24 17:36:46 2021, Paco, General, Design specs, Least common multiple stacks and varL cost
|
Fri Apr 2 19:59:53 2021, Paco, General, Design specs, Differential evolution strategies
|
Fri Jun 4 11:09:27 2021, Paco, General, Design specs, HR coating tolerance analysis
|
Wed Mar 24 17:42:50 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I
|
Tue Jun 22 22:28:09 2021, Koji, General, Design specs, Test Mass wedge design   
|
Wed Jun 30 16:21:53 2021, Stephen, General, Design specs,
|
Fri May 7 09:57:18 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept
|
Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept
|
Tue Jul 27 11:38:25 2021, Paco, General, Design specs, DOPO single pass PDC efficiency
|
Fri Aug 6 04:34:43 2021, Koji, General, General, Theoretical Cooling Time Limit
|
Tue Aug 17 17:48:57 2021, Koji, General, Equipment, Crackle SW model
|
Tue Aug 24 08:15:37 2021, Jiri Smetana, General, General, Actuation Feedback Model  
|
Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame 
|
Thu Sep 9 11:25:30 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion 
|
Thu Sep 9 20:42:34 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion 
|
Wed Sep 15 09:15:21 2021, Jiri Smetana, General, General, Actuation Feedback Model and Noise    
|
Thu Sep 16 10:02:47 2021, Jiri Smetana, General, General, Actuation Feedback Model and Noise
|
Fri Sep 24 11:02:41 2021, Koji, General, General, Actuation Feedback Model and Noise
|
Sun Sep 19 18:52:58 2021, Paco, General, Design specs, HR coating emissivity 
|
Fri Oct 1 11:52:06 2021, Paco, General, Design specs, HR coating emissivity 
|
Fri Oct 1 12:01:24 2021, Paco, General, Design specs, TM Barrel coating emissivity   
|
Fri Oct 1 13:24:40 2021, Aidan, General, Design specs, TM Barrel coating emissivity
|
Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity  
|
Mon Oct 11 15:22:18 2021, Yehonathan, General, General, Microcomb alternatives   
|
Tue Oct 12 12:44:44 2021, Jiri Smetana, General, General, New Damping Loop Model
|
Tue Oct 12 12:49:42 2021, Jiri Smetana, General, General, Damping Loop (Point-Mass Pendulums)    
|
Thu Oct 14 04:17:36 2021, Jiri Smetana, General, General, Damping Loop (Point-Mass Pendulums) 8x
|
Fri Sep 24 13:12:00 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps
|
Mon Sep 27 17:01:53 2021, rana, General, Heat Load, Mariner cooldown model status + next steps
|
Wed Sep 29 16:15:19 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps   
|
Tue Oct 5 17:46:14 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps  
|
Fri Oct 15 13:45:55 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps
|
Fri Oct 15 14:31:15 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps 
|
Tue Oct 26 08:09:08 2021, Jiri Smetana, General, General, Lagrangian Suspension Model - Extended Body 
|
Wed Nov 3 02:52:49 2021, Koji, General, Suspension, Mariner Sus Design
|
Thu Nov 4 00:42:05 2021, Koji, General, Suspension, Mariner Sus Design 
|
Fri Nov 5 11:51:50 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um  
|
Tue Nov 16 11:47:54 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um
|
Wed Nov 17 09:27:04 2021, Jiri Smetana, General, General, Lagrangian Model - Translation & Pitch
|
Wed Dec 15 06:43:43 2021, Jiri Smetana, General, General, Lagrangian Model - Translation & Pitch
|
Thu May 5 19:56:25 2022, Koji, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 
|
Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps
|
Thu Jun 16 14:04:30 2022, Juan, General, Suspension, Table for Mariner Suspension Cryo
|
Thu Jun 16 19:43:36 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo
|
Thu Jun 23 21:11:03 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo
|
Mon Jun 27 08:22:22 2022, Juan, General, General, General Update/ Need to do task
|
Sat Jul 2 09:22:39 2022, Juan , General, General, Progress update
|
Tue Jul 5 21:06:47 2022, Juan, General, General, Work Update 
|
Thu Jul 7 10:23:04 2022, Juan, General, General, Update 
|
Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links
|
Fri Jul 8 17:09:10 2022, Juan, General, General, Coil Driver and Sat Amp  
|
Mon Jul 11 16:24:31 2022, Jennifer Hritz, General, Optical Contacting, Baselining the temperature output of the Oster hot plate 
|
Mon Jul 11 17:27:39 2022, Jennifer Hritz, General, Optical Contacting, First successful bond
|
Mon Jul 11 17:39:17 2022, Juan, General, General, Coil driver chassis 
|
Wed Jul 13 13:16:33 2022, Juan, General, General, Finished coil driver and sat amp
|
Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol   
|
Fri Jul 22 13:47:47 2022, Juan, General, General, Update
|
Tue Jul 26 14:17:44 2022, Juan, General, General, OSEMS actuators 8x
|
Wed Jul 27 14:50:20 2022, Jennifer Hritz, General, Optical Contacting, Bonding without liquids and narrowing down heating issue 
|
Thu Aug 4 11:26:55 2022, Juan, General, General, Sat Amp
|
Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating 
|
Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS
|
Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs    
|
Mon Jul 18 18:34:29 2022, Paco, General, Design specs, HR coating update   
|
Fri Jul 22 13:36:55 2022, Paco, General, Design specs, HR coating update 
|
Tue Aug 16 09:58:23 2022, Paco, General, Design specs, HR coating update 6x
|
Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test 
|
|