72
|
Thu Aug 4 11:26:55 2022 |
Juan | General | General | Sat Amp | Sat amp seems to be working just fine.
There does seem to be a saturation issue
with one of the outputs we may need to change |
|
74
|
Mon Aug 8 13:00:56 2022 |
Juan | General | General | Sat Amp testing of OSEMS | In the following test, a single Sat Amp
chassis that holds Sat Amp Board S1106078
and S1106077 |
|
3
|
Fri Jun 5 11:13:50 2020 |
Raymond | General | Heat Load | Steady state heat load example | Attached is a cartoon partial view into
the heat load experienced by the Mariner
assembly. |
|
30
|
Fri Sep 24 13:12:00 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | *Note: the current modeling script can
be found at: CryoEngineering/MarinerCooldownEstimation.ipynb
Nina pointed me to the current |
|
31
|
Mon Sep 27 17:01:53 2021 |
rana | General | Heat Load | Mariner cooldown model status + next steps | How
about a diagram so that we can understand |
|
32
|
Wed Sep 29 16:15:19 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | Attachment 1 is a geometric diagram that
reflects the current state of the ITM cooldown
model, introduced in [30]. |
   |
37
|
Tue Oct 5 17:46:14 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | Building on [32],
I added a copper cold finger to conductively
cool the inner shield, instead of holding |
  |
42
|
Fri Oct 15 13:45:55 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | I used the same model in [37]
to consider how test mass length affects
the cooldown. Attachment 1 plots the curves |
|
43
|
Fri Oct 15 14:31:15 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | I reran the cooldown model, setting the
emissivity of the inner surface of the inner
shield to 0.7 (coating), and the emissivity |
 |
60
|
Thu Jul 7 15:20:04 2022 |
rana | General | Optical Contacting | some useful links | For our optical contacting, Jennifer and
I are starting out with glass (microscope
slides), with the setup in the EE shop next |
|
62
|
Mon Jul 11 16:24:31 2022 |
Jennifer Hritz | General | Optical Contacting | Baselining the temperature output of the Oster hot plate | This was performed last Friday (7/8).
I secured a thermocouple perpendicular
against the hotplate and recorded the |
 |
63
|
Mon Jul 11 17:27:39 2022 |
Jennifer Hritz | General | Optical Contacting | First successful bond | Note that the slides have "GLOBE"
printed on one side. I always bond the opposite
using the opposite side without the text. |
|
66
|
Thu Jul 14 14:55:01 2022 |
Jennifer Hritz | General | Optical Contacting | Testing isopropanol and methanol | Note that I am just testing out different
techniques, so I have not set up the thermocouples
to precisely measure the temperatue. |
   |
71
|
Wed Jul 27 14:50:20 2022 |
Jennifer Hritz | General | Optical Contacting | Bonding without liquids and narrowing down heating issue | I have found that, after cleaning the glass
with methanol (or even sometimes with just a dry
lense-cleaning cloth), I can get glass slides to |
 |
73
|
Thu Aug 4 13:44:56 2022 |
Jennifer Hritz | General | Optical Contacting | Success with slowly heating | Yesterday, I did two rounds of slowly heating
4 samples to the maximum hot plate temperature.
This was to formally test if my success |
 |
2
|
Thu May 21 12:10:03 2020 |
Stephen | General | Resources | Ongoing Mariner Resources | Ongoing points of updates/content (list
to be maintained and added)
Mariner |
|
23
|
Thu Aug 26 17:40:41 2021 |
Stephen | General | Suspension | Selecting MOS-style frame | [Koji, Stephen]
Kind of a silly post, and not very
scientific, but we are sticking to it. During |
 |
45
|
Wed Nov 3 02:52:49 2021 |
Koji | General | Suspension | Mariner Sus Design | All parameters are temporary:
Test mass size: D150mm x L140mm
Intermediate mass size W152.4mm x |
|
46
|
Thu Nov 4 00:42:05 2021 |
Koji | General | Suspension | Mariner Sus Design | Some more progress:
- Shaved the height of the top
clamp blocks. We can extend the suspension |
 |
51
|
Thu May 5 19:56:25 2022 |
Koji | General | Suspension | Mariner Suspension Cryo shield Install / Removal steps | Does this work? Is this insane? |
 |
52
|
Tue May 10 18:29:11 2022 |
rana | General | Suspension | Mariner Suspension Cryo shield Install / Removal steps | |
|
53
|
Thu Jun 16 14:04:30 2022 |
Juan | General | Suspension | Table for Mariner Suspension Cryo | Today we looked at possible locations for
where we will be setting up Mariner Suspension
and Cryo chamber. The first option was the |
|
54
|
Thu Jun 16 19:43:36 2022 |
Koji | General | Suspension | Table for Mariner Suspension Cryo | - B246/QIL Skyhook
Find the base of Skyhook.
It should be in the storage room (B246). |
|
55
|
Thu Jun 23 21:11:03 2022 |
Koji | General | Suspension | Table for Mariner Suspension Cryo | Table moving effort in the OMC lab: See
https://nodus.ligo.caltech.edu:8081/OMC_Lab/412
|
|