40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, Page 2 of 3  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Wed Jul 13 13:16:33 2022, Juan, General, General, Finished coil driver and sat amp  IMG-5553.jpg
Entry  Fri Jul 22 13:47:47 2022, Juan, General, General, Update 
Entry  Tue Jul 26 14:17:44 2022, Juan, General, General, OSEMS actuators  8x
Entry  Thu Aug 4 11:26:55 2022, Juan, General, General, Sat Amp IMG-6153.jpg
Entry  Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS OSEMs.xlsx
Entry  Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png
Entry  Sat Jan 7 16:07:13 2023, , General, General,  
Entry  Mon Jan 9 21:03:53 2023, Koji, General, General, Heavy item transport - preparation DOPO.jpgCAML.jpgQIL.jpg
    Reply  Tue Jan 10 23:30:25 2023, Koji, General, General, Heavy item transport - preparation PXL_20230110_214532535.jpgPXL_20230110_221731553.jpgPXL_20230110_222947057.MP.jpg
    Reply  Thu Jan 12 11:38:26 2023, Koji, General, General, How to move the large engine hoist through the narrow door PXL_20230110_223009017.jpgPXL_20230110_223015483.MP.jpgPXL_20230110_223026446.MP.jpgPXL_20230110_223035480.MP.jpg
    Reply  Thu Jan 12 11:54:08 2023, Koji, General, General, Heavy item transport 7x
    Reply  Thu Jan 12 15:36:22 2023, Koji, General, General, Crane configuration for the suspension test chamber crane_config.pdf
Entry  Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example Heat_Load_Sketch.pdf
Entry  Fri Sep 24 13:12:00 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps 
    Reply  Mon Sep 27 17:01:53 2021, rana, General, Heat Load, Mariner cooldown model status + next steps 
    Reply  Wed Sep 29 16:15:19 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps Heat_Load_Sketch_geometry.pdfHeat_Load_Sketch_diagram.pdfheating_cooling_P_vs_T.pdfCooldownTM_radiative.pdf
    Reply  Tue Oct 5 17:46:14 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps Heat_Load_Sketch_all.pdfVaryingISA.pdfCooldownTM.pdf
    Reply  Fri Oct 15 13:45:55 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps VaryingTMl.pdf
    Reply  Fri Oct 15 14:31:15 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps VaryingISA.pdfVaryingTMl.pdf
Entry  Fri Aug 26 14:24:57 2022, Radhika, General, Heat Load, Mariner TM Cooldown model 6x
    Reply  Mon Aug 29 15:44:46 2022, Radhika, General, Heat Load, Mariner TM Cooldown model VaryingSnoutparams.pdfMarinerTMCooldown_snout_optimal.pdf
    Reply  Wed Sep 7 10:42:12 2022, Radhika, General, Heat Load, Mariner TM Cooldown model SnoutLengthCooldownTM.pdf
    Reply  Wed Apr 12 12:03:34 2023, Radhika, General, Heat Load, Mariner TM Cooldown model MarinerTMCooldown_LN2_OS.pdfTMPowerBudget.pdfmariner_block_diagram_joints.pdf
Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
Entry  Mon Jul 11 16:24:31 2022, Jennifer Hritz, General, Optical Contacting, Baselining the temperature output of the Oster hot plate PXL_20220708_230038748.jpgPXL_20220708_230234841.MP.jpg
Entry  Mon Jul 11 17:27:39 2022, Jennifer Hritz, General, Optical Contacting, First successful bond PXL_20220712_223449788.MP.jpg
Entry  Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg
Entry  Wed Jul 27 14:50:20 2022, Jennifer Hritz, General, Optical Contacting, Bonding without liquids and narrowing down heating issue PXL_20220727_214658230.jpgPXL_20220727_214241668.mp4
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Wed Sep 28 22:11:31 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides thor_lab_slides_first_bond_PXL_20220929_045352675.MP.jpgthor_lab_slides_after_attempting_to_expand_bond_area_PXL_20220929_045510075.MP.jpg
Entry  Thu Sep 29 18:36:40 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides (continued) before_heat_PXL_20220930_011031420.MP.jpgset_up_PXL_20220930_011050114.MP.jpgright_after_heating_PXL_20220930_014301900.MP.jpgafter_4ish_hours_of_cooling_PXL_20220930_063533904.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Sat Oct 1 23:00:03 2022, Jennifer Hritz, General, Optical Contacting, (RESULTS!) Quick test heat and pressure test samples_before_AND_after_pressure_PXL_20221002_054158446.MP.jpgsamples_before_AND_after_heat_w_pressure_PXL_20221002_053842185.MP.jpg
Entry  Sun Oct 2 23:23:07 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure before_time_on_left_pressure_on_right_PXL_20221003_061828860.MP.jpgset_up_time_vs_pressure_PXL_20221003_062018249.MP.jpgin_progress_time_vs_pressure_PXL_20221003_062117715.MP.jpg
Entry  Mon Oct 3 23:32:30 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure (Update) pressure_v_time_samples_both.jpg
Entry  Tue Oct 4 22:15:23 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #1 PWM_Test_#1_(first_300_sec).pdfframe_from_pwm_test1_video_PXL_20221005_064240498_exported_231444.jpg
Entry  Wed Oct 5 23:24:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #2 PWM_Test_#2.pdfPWM_Test_#2_(comparison).pdf
Entry  Fri Oct 7 00:21:24 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #3 PWM_Test_#3.pdfPWM_Test_#3_(comparison).pdfhot_plate_cycler_v1.zipPWM_tests_1-3.zip
Entry  Fri Oct 7 21:20:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 progress PWM_Test_#2_(log_comparison).pdfPWM_Test_#3_(log_comparison).pdf
Entry  Sat Oct 8 23:22:25 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 PWM_v2_Test_#1.pdf
Entry  Sun Oct 9 21:55:53 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 & 2 PWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Mon Oct 10 15:34:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.1,2,3 Test #1 and v2.3 Test #2 PWM_v2.1_test1_max_rate_reached_and_peak_heat.jpg
Entry  Tue Oct 11 23:59:07 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #1 and 2 PWM_v2.3_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2.3_Test_#2_-_increase_180°C_in_7_minutes.pdfPWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Wed Oct 12 23:26:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #3 PWM_v2.3_Test_#3_-_increase_180°C_in_20_minutes.pdf
Entry  Thu Oct 13 20:56:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.4,5 Test #3 PWM_v2.3_Test_#3_-_increase_180C_in_20_minutes.pdf
Entry  Fri Oct 14 21:36:52 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #3 PWM_v2_Test_#3_-_increase_180°C_in_20_minutes.pdfPWM_v2.6_Test_#3_-_increase_180°C_in_20_minutes.pdfcycler_v1_graphs.zipcycler_v2_graphs.ziphot_plate_cycler_v1-2.6.zip
Entry  Sat Oct 15 21:59:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #1, 2, 3 PWM_v2.6_Test_#1_2_3_-_increase_180C_in_10_7_20_minutes.pdfPWM_v2.6_tests_data.zip
Entry  Sun Oct 16 14:20:32 2022, Jennifer Hritz, General, Optical Contacting, Samples after 2 weeks under pressure 2_weeks_pressure_PXL_20221004_190652540_20221017_074745619.jpg
ELOG V3.1.3-