40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, Page 2 of 3  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  50   Wed Dec 15 06:43:43 2021 Jiri SmetanaGeneralGeneralLagrangian Model - Translation & PitchI've checked the validity of my state
space model in a couple of ways so that we
have confidence in the results that it gives.
  
  53   Thu Jun 16 14:04:30 2022 JuanGeneralSuspensionTable for Mariner Suspension CryoToday we looked at possible locations for
where we will be setting up Mariner Suspension
and Cryo chamber. The first option was the
  
  56   Mon Jun 27 08:22:22 2022 JuanGeneralGeneralGeneral Update/ Need to do taskI've managed to cut and crimp wires
for the power board for coil driver. I will
begin adding components to the coil driver
 coildrive.jpg 
  58   Tue Jul 5 21:06:47 2022 JuanGeneralGeneralWork Update Update of my current work I have finished
one coil driver board and started on the
last two that I need here is the progress
 IMG-5362.jpgIMG-5361.jpg 
  59   Thu Jul 7 10:23:04 2022 JuanGeneralGeneralUpdate Almost done with coil driver boards   IMG-5378.jpgIMG-5379.jpg 
  61   Fri Jul 8 17:09:10 2022 JuanGeneralGeneralCoil Driver and Sat AmpAll three coil driver boards are complete
and have been tested. Modification for all
4 sat amp have been completed. Ideally, I
 IMG-5434.jpgIMG-5421.jpgIMG-5420.jpg 
  64   Mon Jul 11 17:39:17 2022 JuanGeneralGeneralCoil driver chassis Finished all 3 Coil Drover chassis
and power lines still need to install the
rear cables will do that after I finish Sat
 IMG-5493.jpgIMG-5494.jpg 
  65   Wed Jul 13 13:16:33 2022 JuanGeneralGeneralFinished coil driver and sat amp I have finished all coil driver and sat
amp chassis they all seem to be functioning
properly.
 IMG-5553.jpg 
  69   Fri Jul 22 13:47:47 2022 JuanGeneralGeneralUpdateJust a general update of what I have been
up to deriving Lagrange for double pendulum
system and also been looking at code that
  
  70   Tue Jul 26 14:17:44 2022 JuanGeneralGeneralOSEMS actuators we have 23 OSEMS they look all full built
and I will try and test them this week and
or next week.
 8x 
  72   Thu Aug 4 11:26:55 2022 JuanGeneralGeneralSat AmpSat amp seems to be working just fine.
There does seem to be a saturation issue
with one of the outputs we may need to change
 IMG-6153.jpg 
  74   Mon Aug 8 13:00:56 2022 JuanGeneralGeneralSat Amp testing of OSEMSIn the following test, a single Sat Amp
chassis that holds Sat Amp Board S1106078
and S1106077
 OSEMs.xlsx 
  57   Sat Jul 2 09:22:39 2022 Juan GeneralGeneralProgress update I've completed one coil driver board. 
Hopefully next week I can finish the
other 2 boards and make the modifications
 IMG-5220.jpg 
  75   Mon Aug 15 16:37:51 2022 Juan GeneralGeneralUpdate on Sat Amp and OSEMsSat
Amp 

 IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png 
  1   Thu May 21 11:51:44 2020 KojiGeneralGeneralMariner Elog TestThe first entry of the Mariner elog post   
  16   Tue Jun 22 22:28:09 2021 KojiGeneralDesign specsTest Mass wedge designThe
ETM wedge of 0.5deg will allow us to separate
the AR reflections. We will be OK with the
 wedge.pdfLayout.pdfETM.pdfITM.pdf 
  20   Fri Aug 6 04:34:43 2021 KojiGeneralGeneralTheoretical Cooling Time LimitI was thinking about how fast we can cool
the test mass. No matter how we improve the
emissivity of the test mass and the cryostat,
 cooling_curves.pdf 
  21   Tue Aug 17 17:48:57 2021 KojiGeneralEquipmentCrackle SW modelAs a kickoff of the mariner sus cryostat
design, I made a tentative crackle chamber
model in SW.
 Screen_Shot_2021-08-17_at_17.44.32.png 
  29   Fri Sep 24 11:02:41 2021 KojiGeneralGeneralActuation Feedback Model and NoiseWe had a meeting with the code open in
ZOOM. Here are some points we discussed:


The code requires another
 ground.m 
  45   Wed Nov 3 02:52:49 2021 KojiGeneralSuspensionMariner Sus DesignAll parameters are temporary:

Test mass size: D150mm x L140mm
Intermediate mass size W152.4mm x
  
  46   Thu Nov 4 00:42:05 2021 KojiGeneralSuspensionMariner Sus DesignSome more progress:

- Shaved the height of the top
clamp blocks. We can extend the suspension
 Screen_Shot_2021-11-04_at_12.38.46_AM.pngScreen_Shot_2021-11-04_at_12.39.53_AM.png 
  51   Thu May 5 19:56:25 2022 KojiGeneralSuspensionMariner Suspension Cryo shield Install / Removal stepsDoes this work? Is this insane?  40m_Mariner_Suspension-0062.png40m_Mariner_Suspension.mp4 
  54   Thu Jun 16 19:43:36 2022 KojiGeneralSuspensionTable for Mariner Suspension Cryo- B246/QIL Skyhook


Find the base of Skyhook.
It should be in the storage room (B246).
  
  55   Thu Jun 23 21:11:03 2022 KojiGeneralSuspensionTable for Mariner Suspension CryoTable moving effort in the OMC lab: See
https://nodus.ligo.caltech.edu:8081/OMC_Lab/412

 
  
  120   Mon Jan 9 21:03:53 2023 KojiGeneralGeneralHeavy item transport - preparation1) Paco cleared the path in the DOPO lab.
We'll need a flat dolly or wooden bars
(covered with a mylar sheet) to place the
 DOPO.jpgCAML.jpgQIL.jpg 
  121   Tue Jan 10 23:30:25 2023 KojiGeneralGeneralHeavy item transport - preparation[JC, Stephen, Paco, Gabriele, Aidan,
Radhika, Koji]

We have successfully extracted
 PXL_20230110_214532535.jpgPXL_20230110_221731553.jpgPXL_20230110_222947057.MP.jpg 
  122   Thu Jan 12 11:38:26 2023 KojiGeneralGeneralHow to move the large engine hoist through the narrow doorSee the attachments.  PXL_20230110_223009017.jpgPXL_20230110_223015483.MP.jpgPXL_20230110_223026446.MP.jpgPXL_20230110_223035480.MP.jpg 
  123   Thu Jan 12 11:54:08 2023 KojiGeneralGeneralHeavy item transport[JC, Koji]

Caltech transport came in this
morning. They first went to the OMC lab and
 7x 
  124   Thu Jan 12 15:36:22 2023 KojiGeneralGeneralCrane configuration for the suspension test chamberI made a quick investigation of the crane
configuration for the suspension test chamber.

Conclusions:
 crane_config.pdf 
  12   Tue Apr 27 12:28:43 2021 Nina Vaidya & Shruti MaliakalGeneralDesign specsArm Cavity Design 2021Rana’s code: R_c = 57.3

-->New code with optimization:
sweeping through a range of R_c, using a
 Arm_Cavity_Design_04232021.pptxArm_HOM_optimization.ipynb 
  14   Fri May 7 17:50:31 2021 Nina Vaidya & Shruti MaliakalGeneralDesign specsArm Cavity Design 2021 updateHere are the final slides with all the
results on the Arm Cavity Design, please
review. 
 Arm_Cavity_Design_05072021_with_tolerances.pptxHOMhelper.pyArm_HOManalysis.ipynbHOMplot.py 
  4   Thu Mar 4 17:04:52 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IHave been using the 40m
Coatings repo code by Gautam (with some
modifications to make dichroic designs under
 ETM_coating_candidates.pdfITM_coating_candidates.pdf 
  6   Wed Mar 17 19:51:42 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IUpdate on ETM

New optima are
being found using the same basic code with
some modifications, which I summarize below;
 ETM_R_210317_1927.pdfETM_Layers_210317_1927.pdfETM_nominal_cornerPlt.pdf 
  8   Wed Mar 24 17:36:46 2021 PacoGeneralDesign specsLeast common multiple stacks and varL costUpdate on ETM/ITM coating design;

-
Following what seemed like a good, intuitive
suggestion from Anchal, I implemented a parameter
 ETM_Layers_210323_0925.pdf 
  9   Wed Mar 24 17:42:50 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IYeah, the magnitudes are the inverse weighted
scalar costs (so they lie on the appropriate
relative scale) and indeed larger enclosed
  
  10   Fri Apr 2 19:59:53 2021 PacoGeneralDesign specsDifferential evolution strategiesDifferential evolution strategies 'benchmarking'
for thin film optimization

Since
I have been running the ETM/ITM coatings
 diffevostrategies.pdf 
  15   Fri Jun 4 11:09:27 2021 PacoGeneralDesign specsHR coating tolerance analysisThe HR coating specifications are:


ETM
  
  19   Tue Jul 27 11:38:25 2021 PacoGeneralDesign specsDOPO single pass PDC efficiencyHere is a set of curves describing the
single-pass downconversion efficiency in
the 20 mm long PPKTP crystals for the DOPO.
 singlepass_eff_overest.pdf 
  24   Thu Sep 9 11:25:30 2021 PacoGeneralDesign specsRerun HR coatings with n,k dispersion[Paco]

I've re-run the HR coating
designs for both ETM and ITM using interpolated
 etm_updated.pdfitm_updated.pdf 
  25   Thu Sep 9 20:42:34 2021 PacoGeneralDesign specsRerun HR coatings with n,k dispersion[Paco]

Alright, I've done a re-optimization
targetting a wider T band around 2128 nm.
 ETM210909190218.pdfITMLayers210909204021.pdf 
  28   Sun Sep 19 18:52:58 2021 PacoGeneralDesign specsHR coating emissivity[Paco, Nina]

We have been working on an estimate
of the wavelength dependent emissivity for
 ETM_210409_120913_emissivity.pdfinterpolated_TF_k.pdf 
  33   Fri Oct 1 11:52:06 2021 PacoGeneralDesign specsHR coating emissivity[Paco, Nina, Aidan]

Updated the stack emissivity code
to use the Kitamura paper fused silica dispersion
 ETM_210409_120913_emissivity.pdfinterpolated_n_k.pdf 
  34   Fri Oct 1 12:01:24 2021 PacoGeneralDesign specsTM Barrel coating emissivity[Paco, Nina, Aidan]

We ran our stack emissivity calculation
on different AR stacks to try and make a
 stack_1.pdfstack_2.pdfstack_3.pdfinterpolated_n_k.pdf 
  36   Fri Oct 1 14:11:23 2021 PacoGeneralDesign specsTM Barrel coating emissivityAgree with this.
Quickly running tmm on the same "stacks"
gave the Attachment #1-3. (Ignore the
 stack_1.pdfstack_2.pdfstack_3.pdf 
  47   Fri Nov 5 11:51:50 2021 PacoGeneralDesign specsEstimate of in-air absorption near 2.05 um[Paco]

I used the HITRAN database to download
the set of ro-vibrational absorption lines
 HITRAN_line_strenghts.pdfbroadened_spectrum.pdfPP_broadened_spectrum.pdf 
  48   Tue Nov 16 11:47:54 2021 PacoGeneralDesign specsEstimate of in-air absorption near 2.05 um[Paco]

There was an error in the last
plot of the previous log. This was correctly
 PP_broadened_spectrum.pdf 
  67   Mon Jul 18 18:34:29 2022 PacoGeneralDesign specsHR coating updateI've been running the HR coating optimization
for mariner TMs. Relative to the specifications
found here
 ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf 
  68   Fri Jul 22 13:36:55 2022 PacoGeneralDesign specsHR coating updateHere are some corner plots to analyze the
sensitivity of the designs in the previous
elog to a 1% gaussian
 ETM_corner.pdfITM_corner.pdf 
  76   Tue Aug 16 09:58:23 2022 PacoGeneralDesign specsHR coating updateA couple of coating stacks with better
tolerance (transmission +- 10%). Attachments
#1-2 show the spectral reflectivities
 6x 
  78   Tue Aug 23 17:10:50 2022 PacoGeneralDesign specsNew corner plotsInstead of varying individual layer thicknesses
using the MC sampler, I made sure both the
thickness and index of refractions are varied
 ITM_corner.pdfETM_corner.pdf 
ELOG V3.1.3-