40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, all entries  Not logged in ELOG logo
Entry  Thu May 21 11:51:44 2020, Koji, General, General, Mariner Elog Test 
Entry  Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources 
Entry  Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example Heat_Load_Sketch.pdf
Entry  Fri Mar 5 11:05:13 2021, Stephen, General, Design specs, Feasibility of 6" optic size in CAD 4in_from_20210305_easm.png6in_from_20210305_easm.png
Entry  Fri Apr 23 10:41:22 2021, Aidan, General, Design specs, 2 um photodiode requirements 
Entry  Tue Apr 27 12:28:43 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 Arm_Cavity_Design_04232021.pptxArm_HOM_optimization.ipynb
Entry  Fri May 7 17:50:31 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 update Arm_Cavity_Design_05072021_with_tolerances.pptxHOMhelper.pyArm_HOManalysis.ipynbHOMplot.py
   +  Reply  Fri Jun 4 11:09:27 2021, Paco, General, Design specs, HR coating tolerance analysis 
Entry  Tue Jun 22 22:28:09 2021, Koji, General, Design specs, Test Mass wedge design wedge.pdfLayout.pdfETM.pdfITM.pdf
Entry  Wed Jun 30 16:21:53 2021, Stephen, General, Design specs,  
   +  Reply  Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept 
Entry  Tue Jul 27 11:38:25 2021, Paco, General, Design specs, DOPO single pass PDC efficiency singlepass_eff_overest.pdf
Entry  Fri Aug 6 04:34:43 2021, Koji, General, General, Theoretical Cooling Time Limit cooling_curves.pdf
Entry  Tue Aug 17 17:48:57 2021, Koji, General, Equipment, Crackle SW model Screen_Shot_2021-08-17_at_17.44.32.png
Entry  Tue Aug 24 08:15:37 2021, Jiri Smetana, General, General, Actuation Feedback Model actuator_feedback_diagram.pngbode_servo.pngbode_plant.png
Entry  Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame no_sos_cad_screenshot.pngvault_check_in_of_mariner_suspension_cad.png
   +  Reply  Thu Sep 9 20:42:34 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion ETM210909190218.pdfITMLayers210909204021.pdf
   +  Reply  Fri Sep 24 11:02:41 2021, Koji, General, General, Actuation Feedback Model and Noise ground.m
   +  Reply  Fri Oct 1 11:52:06 2021, Paco, General, Design specs, HR coating emissivity ETM_210409_120913_emissivity.pdfinterpolated_n_k.pdf
   +  Reply  Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity stack_1.pdfstack_2.pdfstack_3.pdf
Entry  Mon Oct 11 15:22:18 2021, Yehonathan, General, General, Microcomb alternatives ELMO_specs.pngHNLF_specs.pngSimulationResults1.pngSimulationResults3.png
Entry  Tue Oct 12 12:44:44 2021, Jiri Smetana, General, General, New Damping Loop Model 
   +  Reply  Thu Oct 14 04:17:36 2021, Jiri Smetana, General, General, Damping Loop (Point-Mass Pendulums) 8x
   +  Reply  Fri Oct 15 14:31:15 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps VaryingISA.pdfVaryingTMl.pdf
Entry  Tue Oct 26 08:09:08 2021, Jiri Smetana, General, General, Lagrangian Suspension Model - Extended Body comparison_xg.pngcomarison_F.png
   +  Reply  Thu Nov 4 00:42:05 2021, Koji, General, Suspension, Mariner Sus Design Screen_Shot_2021-11-04_at_12.38.46_AM.pngScreen_Shot_2021-11-04_at_12.39.53_AM.png
   +  Reply  Tue Nov 16 11:47:54 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um PP_broadened_spectrum.pdf
   +  Reply  Wed Dec 15 06:43:43 2021, Jiri Smetana, General, General, Lagrangian Model - Translation & Pitch 
   +  Reply  Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 
   +  Reply  Thu Jun 23 21:11:03 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
Entry  Mon Jun 27 08:22:22 2022, Juan, General, General, General Update/ Need to do task coildrive.jpg
Entry  Sat Jul 2 09:22:39 2022, Juan , General, General, Progress update  IMG-5220.jpg
Entry  Tue Jul 5 21:06:47 2022, Juan, General, General, Work Update  IMG-5362.jpgIMG-5361.jpg
Entry  Thu Jul 7 10:23:04 2022, Juan, General, General, Update  IMG-5378.jpgIMG-5379.jpg
Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
Entry  Fri Jul 8 17:09:10 2022, Juan, General, General, Coil Driver and Sat Amp IMG-5434.jpgIMG-5421.jpgIMG-5420.jpg
Entry  Mon Jul 11 16:24:31 2022, Jennifer Hritz, General, Optical Contacting, Baselining the temperature output of the Oster hot plate PXL_20220708_230038748.jpgPXL_20220708_230234841.MP.jpg
Entry  Mon Jul 11 17:27:39 2022, Jennifer Hritz, General, Optical Contacting, First successful bond PXL_20220712_223449788.MP.jpg
Entry  Mon Jul 11 17:39:17 2022, Juan, General, General, Coil driver chassis  IMG-5493.jpgIMG-5494.jpg
Entry  Wed Jul 13 13:16:33 2022, Juan, General, General, Finished coil driver and sat amp  IMG-5553.jpg
Entry  Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg
Entry  Fri Jul 22 13:47:47 2022, Juan, General, General, Update 
Entry  Tue Jul 26 14:17:44 2022, Juan, General, General, OSEMS actuators  8x
Entry  Wed Jul 27 14:50:20 2022, Jennifer Hritz, General, Optical Contacting, Bonding without liquids and narrowing down heating issue PXL_20220727_214658230.jpgPXL_20220727_214241668.mp4
Entry  Thu Aug 4 11:26:55 2022, Juan, General, General, Sat Amp IMG-6153.jpg
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
Entry  Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS OSEMs.xlsx
Entry  Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
   +  Reply  Tue Aug 23 17:10:50 2022, Paco, General, Design specs, New corner plots ITM_corner.pdfETM_corner.pdf
   +  Reply  Wed Sep 7 10:42:12 2022, Radhika, General, Heat Load, Mariner TM Cooldown model SnoutLengthCooldownTM.pdf
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Wed Sep 28 22:11:31 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides thor_lab_slides_first_bond_PXL_20220929_045352675.MP.jpgthor_lab_slides_after_attempting_to_expand_bond_area_PXL_20220929_045510075.MP.jpg
Entry  Thu Sep 29 18:36:40 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides (continued) before_heat_PXL_20220930_011031420.MP.jpgset_up_PXL_20220930_011050114.MP.jpgright_after_heating_PXL_20220930_014301900.MP.jpgafter_4ish_hours_of_cooling_PXL_20220930_063533904.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Sat Oct 1 23:00:03 2022, Jennifer Hritz, General, Optical Contacting, (RESULTS!) Quick test heat and pressure test samples_before_AND_after_pressure_PXL_20221002_054158446.MP.jpgsamples_before_AND_after_heat_w_pressure_PXL_20221002_053842185.MP.jpg
Entry  Sun Oct 2 23:23:07 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure before_time_on_left_pressure_on_right_PXL_20221003_061828860.MP.jpgset_up_time_vs_pressure_PXL_20221003_062018249.MP.jpgin_progress_time_vs_pressure_PXL_20221003_062117715.MP.jpg
Entry  Mon Oct 3 23:32:30 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure (Update) pressure_v_time_samples_both.jpg
Entry  Tue Oct 4 22:15:23 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #1 PWM_Test_#1_(first_300_sec).pdfframe_from_pwm_test1_video_PXL_20221005_064240498_exported_231444.jpg
Entry  Wed Oct 5 23:24:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #2 PWM_Test_#2.pdfPWM_Test_#2_(comparison).pdf