40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, all entries  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  74   Mon Aug 8 13:00:56 2022 JuanGeneralGeneralSat Amp testing of OSEMSIn the following test, a single Sat Amp
chassis that holds Sat Amp Board S1106078
and S1106077
 OSEMs.xlsx 
  73   Thu Aug 4 13:44:56 2022 Jennifer HritzGeneralOptical ContactingSuccess with slowly heatingYesterday, I did two rounds of slowly heating
4 samples to the maximum hot plate temperature.
This was to formally test if my success
 PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg 
  72   Thu Aug 4 11:26:55 2022 JuanGeneralGeneralSat AmpSat amp seems to be working just fine.
There does seem to be a saturation issue
with one of the outputs we may need to change
 IMG-6153.jpg 
  71   Wed Jul 27 14:50:20 2022 Jennifer HritzGeneralOptical ContactingBonding without liquids and narrowing down heating issueI have found that, after cleaning the glass
with methanol (or even sometimes with just a dry
lense-cleaning cloth), I can get glass slides to
 PXL_20220727_214658230.jpgPXL_20220727_214241668.mp4 
  70   Tue Jul 26 14:17:44 2022 JuanGeneralGeneralOSEMS actuators we have 23 OSEMS they look all full built
and I will try and test them this week and
or next week.
 8x 
  69   Fri Jul 22 13:47:47 2022 JuanGeneralGeneralUpdateJust a general update of what I have been
up to deriving Lagrange for double pendulum
system and also been looking at code that
  
  68   Fri Jul 22 13:36:55 2022 PacoGeneralDesign specsHR coating updateHere are some corner plots to analyze the
sensitivity of the designs in the previous
elog to a 1% gaussian
 ETM_corner.pdfITM_corner.pdf 
  67   Mon Jul 18 18:34:29 2022 PacoGeneralDesign specsHR coating updateI've been running the HR coating optimization
for mariner TMs. Relative to the specifications
found here
 ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf 
  66   Thu Jul 14 14:55:01 2022 Jennifer HritzGeneralOptical ContactingTesting isopropanol and methanolNote that I am just testing out different
techniques, so I have not set up the thermocouples
to precisely measure the temperatue.
 PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg 
  65   Wed Jul 13 13:16:33 2022 JuanGeneralGeneralFinished coil driver and sat amp I have finished all coil driver and sat
amp chassis they all seem to be functioning
properly.
 IMG-5553.jpg 
  64   Mon Jul 11 17:39:17 2022 JuanGeneralGeneralCoil driver chassis Finished all 3 Coil Drover chassis
and power lines still need to install the
rear cables will do that after I finish Sat
 IMG-5493.jpgIMG-5494.jpg 
  63   Mon Jul 11 17:27:39 2022 Jennifer HritzGeneralOptical ContactingFirst successful bondNote that the slides have "GLOBE"
printed on one side. I always bond the opposite
using the opposite side without the text.
 PXL_20220712_223449788.MP.jpg 
  62   Mon Jul 11 16:24:31 2022 Jennifer HritzGeneralOptical ContactingBaselining the temperature output of the Oster hot plateThis was performed last Friday (7/8).

I secured a thermocouple perpendicular
against the hotplate and recorded the
 PXL_20220708_230038748.jpgPXL_20220708_230234841.MP.jpg 
  61   Fri Jul 8 17:09:10 2022 JuanGeneralGeneralCoil Driver and Sat AmpAll three coil driver boards are complete
and have been tested. Modification for all
4 sat amp have been completed. Ideally, I
 IMG-5434.jpgIMG-5421.jpgIMG-5420.jpg 
  60   Thu Jul 7 15:20:04 2022 ranaGeneralOptical Contactingsome useful linksFor our optical contacting, Jennifer and
I are starting out with glass (microscope
slides), with the setup in the EE shop next
  
  59   Thu Jul 7 10:23:04 2022 JuanGeneralGeneralUpdate Almost done with coil driver boards   IMG-5378.jpgIMG-5379.jpg 
  58   Tue Jul 5 21:06:47 2022 JuanGeneralGeneralWork Update Update of my current work I have finished
one coil driver board and started on the
last two that I need here is the progress
 IMG-5362.jpgIMG-5361.jpg 
  57   Sat Jul 2 09:22:39 2022 Juan GeneralGeneralProgress update I've completed one coil driver board. 
Hopefully next week I can finish the
other 2 boards and make the modifications
 IMG-5220.jpg 
  56   Mon Jun 27 08:22:22 2022 JuanGeneralGeneralGeneral Update/ Need to do taskI've managed to cut and crimp wires
for the power board for coil driver. I will
begin adding components to the coil driver
 coildrive.jpg 
  55   Thu Jun 23 21:11:03 2022 KojiGeneralSuspensionTable for Mariner Suspension CryoTable moving effort in the OMC lab: See
https://nodus.ligo.caltech.edu:8081/OMC_Lab/412

 
  
  54   Thu Jun 16 19:43:36 2022 KojiGeneralSuspensionTable for Mariner Suspension Cryo- B246/QIL Skyhook


Find the base of Skyhook.
It should be in the storage room (B246).
  
  53   Thu Jun 16 14:04:30 2022 JuanGeneralSuspensionTable for Mariner Suspension CryoToday we looked at possible locations for
where we will be setting up Mariner Suspension
and Cryo chamber. The first option was the
  
  52   Tue May 10 18:29:11 2022 ranaGeneralSuspensionMariner Suspension Cryo shield Install / Removal steps    
  51   Thu May 5 19:56:25 2022 KojiGeneralSuspensionMariner Suspension Cryo shield Install / Removal stepsDoes this work? Is this insane?  40m_Mariner_Suspension-0062.png40m_Mariner_Suspension.mp4 
  50   Wed Dec 15 06:43:43 2021 Jiri SmetanaGeneralGeneralLagrangian Model - Translation & PitchI've checked the validity of my state
space model in a couple of ways so that we
have confidence in the results that it gives.
  
  49   Wed Nov 17 09:27:04 2021 Jiri SmetanaGeneralGeneralLagrangian Model - Translation & PitchI've been having a look at the transfer
functions for the translation and pitch of
both masses. I'm attaching the plot of
 plant_all_tfs.png 
  48   Tue Nov 16 11:47:54 2021 PacoGeneralDesign specsEstimate of in-air absorption near 2.05 um[Paco]

There was an error in the last
plot of the previous log. This was correctly
 PP_broadened_spectrum.pdf 
  47   Fri Nov 5 11:51:50 2021 PacoGeneralDesign specsEstimate of in-air absorption near 2.05 um[Paco]

I used the HITRAN database to download
the set of ro-vibrational absorption lines
 HITRAN_line_strenghts.pdfbroadened_spectrum.pdfPP_broadened_spectrum.pdf 
  46   Thu Nov 4 00:42:05 2021 KojiGeneralSuspensionMariner Sus DesignSome more progress:

- Shaved the height of the top
clamp blocks. We can extend the suspension
 Screen_Shot_2021-11-04_at_12.38.46_AM.pngScreen_Shot_2021-11-04_at_12.39.53_AM.png 
  45   Wed Nov 3 02:52:49 2021 KojiGeneralSuspensionMariner Sus DesignAll parameters are temporary:

Test mass size: D150mm x L140mm
Intermediate mass size W152.4mm x
  
  44   Tue Oct 26 08:09:08 2021 Jiri SmetanaGeneralGeneralLagrangian Suspension Model - Extended BodyI've been testing out the extended
body lagrangian models and I'm trying
to understand the ground motion and force
 comparison_xg.pngcomarison_F.png 
  43   Fri Oct 15 14:31:15 2021 RadhikaGeneralHeat LoadMariner cooldown model status + next stepsI reran the cooldown model, setting the
emissivity of the inner surface of the inner
shield to 0.7 (coating), and the emissivity
 VaryingISA.pdfVaryingTMl.pdf 
  42   Fri Oct 15 13:45:55 2021 RadhikaGeneralHeat LoadMariner cooldown model status + next stepsI used the same model in [37]
to consider how test mass length affects
the cooldown. Attachment 1 plots the curves
 VaryingTMl.pdf 
  41   Thu Oct 14 04:17:36 2021 Jiri SmetanaGeneralGeneralDamping Loop (Point-Mass Pendulums)Here are the DAC and residual displacement
spectra for different suspension heights
ranging from 450 mm to 600 mm. I aimed to
 8x 
  40   Tue Oct 12 12:49:42 2021 Jiri SmetanaGeneralGeneralDamping Loop (Point-Mass Pendulums)Now that I have correct phase and amplitude
behaviour for my MIMO state space model of
the suspension and the system is being correctly
 servo.pngopen_loop.pngclosed_loop.pngnoise.pnglength_change.png 
  39   Tue Oct 12 12:44:44 2021 Jiri SmetanaGeneralGeneralNew Damping Loop ModelI've ironed out the issues with my
MATLAB model so that it now shows correct
phase behaviour. The problem seems to arise
  
  38   Mon Oct 11 15:22:18 2021 YehonathanGeneralGeneralMicrocomb alternativesFollowing our discussion at the Friday
JC meeting, I gathered several resources
and made a small simulation to show how frequency
 ELMO_specs.pngHNLF_specs.pngSimulationResults1.pngSimulationResults3.png 
  37   Tue Oct 5 17:46:14 2021 RadhikaGeneralHeat LoadMariner cooldown model status + next stepsBuilding on [32],
I added a copper cold finger to conductively
cool the inner shield, instead of holding
 Heat_Load_Sketch_all.pdfVaryingISA.pdfCooldownTM.pdf 
  36   Fri Oct 1 14:11:23 2021 PacoGeneralDesign specsTM Barrel coating emissivityAgree with this.
Quickly running tmm on the same "stacks"
gave the Attachment #1-3. (Ignore the
 stack_1.pdfstack_2.pdfstack_3.pdf 
  35   Fri Oct 1 13:24:40 2021 AidanGeneralDesign specsTM Barrel coating emissivityI have to question whether this passes
a sanity test. Surely in the case of Stack
2, the 10um thick Ta2O5 will absorb the majority
  
  34   Fri Oct 1 12:01:24 2021 PacoGeneralDesign specsTM Barrel coating emissivity[Paco, Nina, Aidan]

We ran our stack emissivity calculation
on different AR stacks to try and make a
 stack_1.pdfstack_2.pdfstack_3.pdfinterpolated_n_k.pdf 
  33   Fri Oct 1 11:52:06 2021 PacoGeneralDesign specsHR coating emissivity[Paco, Nina, Aidan]

Updated the stack emissivity code
to use the Kitamura paper fused silica dispersion
 ETM_210409_120913_emissivity.pdfinterpolated_n_k.pdf 
  32   Wed Sep 29 16:15:19 2021 RadhikaGeneralHeat LoadMariner cooldown model status + next stepsAttachment 1 is a geometric diagram that
reflects the current state of the ITM cooldown
model, introduced in [30].
 Heat_Load_Sketch_geometry.pdfHeat_Load_Sketch_diagram.pdfheating_cooling_P_vs_T.pdfCooldownTM_radiative.pdf 
  31   Mon Sep 27 17:01:53 2021 ranaGeneralHeat LoadMariner cooldown model status + next stepsHow
about a diagram so that we can understand
  
  30   Fri Sep 24 13:12:00 2021 RadhikaGeneralHeat LoadMariner cooldown model status + next steps*Note: the current modeling script can
be found at: CryoEngineering/MarinerCooldownEstimation.ipynb

Nina pointed me to the current
  
  29   Fri Sep 24 11:02:41 2021 KojiGeneralGeneralActuation Feedback Model and NoiseWe had a meeting with the code open in
ZOOM. Here are some points we discussed:


The code requires another
 ground.m 
  28   Sun Sep 19 18:52:58 2021 PacoGeneralDesign specsHR coating emissivity[Paco, Nina]

We have been working on an estimate
of the wavelength dependent emissivity for
 ETM_210409_120913_emissivity.pdfinterpolated_TF_k.pdf 
  27   Thu Sep 16 10:02:47 2021 Jiri SmetanaGeneralGeneralActuation Feedback Model and NoiseHere's the DAC voltage spectrum with
its associated RMS.

Also, for clarity, this model is
 DAC_voltage.png 
  26   Wed Sep 15 09:15:21 2021 Jiri SmetanaGeneralGeneralActuation Feedback Model and NoiseI've implemented a more extensive feedback
model that uses proper conversions between
metres, volts, counts etc. and includes all
 displacement_asd.pngservo.pngsystem_loop.mground_freq.txtground_xx.txt 
  25   Thu Sep 9 20:42:34 2021 PacoGeneralDesign specsRerun HR coatings with n,k dispersion[Paco]

Alright, I've done a re-optimization
targetting a wider T band around 2128 nm.
 ETM210909190218.pdfITMLayers210909204021.pdf 
  24   Thu Sep 9 11:25:30 2021 PacoGeneralDesign specsRerun HR coatings with n,k dispersion[Paco]

I've re-run the HR coating
designs for both ETM and ITM using interpolated
 etm_updated.pdfitm_updated.pdf 
  23   Thu Aug 26 17:40:41 2021 StephenGeneralSuspensionSelecting MOS-style frame[Koji, Stephen]

Kind of a silly post, and not very
scientific, but we are sticking to it. During
 no_sos_cad_screenshot.pngvault_check_in_of_mariner_suspension_cad.png 
  22   Tue Aug 24 08:15:37 2021 Jiri SmetanaGeneralGeneralActuation Feedback ModelI'm posting a summary of the work I've
done on the Lagrangian analysis of the Mariner
suspension design and a state space model
 actuator_feedback_diagram.pngbode_servo.pngbode_plant.png 
  21   Tue Aug 17 17:48:57 2021 KojiGeneralEquipmentCrackle SW modelAs a kickoff of the mariner sus cryostat
design, I made a tentative crackle chamber
model in SW.
 Screen_Shot_2021-08-17_at_17.44.32.png 
  20   Fri Aug 6 04:34:43 2021 KojiGeneralGeneralTheoretical Cooling Time LimitI was thinking about how fast we can cool
the test mass. No matter how we improve the
emissivity of the test mass and the cryostat,
 cooling_curves.pdf 
  19   Tue Jul 27 11:38:25 2021 PacoGeneralDesign specsDOPO single pass PDC efficiencyHere is a set of curves describing the
single-pass downconversion efficiency in
the 20 mm long PPKTP crystals for the DOPO.
 singlepass_eff_overest.pdf 
  18   Wed Jul 7 16:32:27 2021 StephenGeneralEquipmentOverall Dimensions for Mariner Suspension Test Chamber ConceptWIP - Stephen to check on new suspension
dimensions and fit into 40m chamber
  
  17   Wed Jun 30 16:21:53 2021 StephenGeneralDesign specs [Stephen, Koji]

WIP - check layout of 60 cm suspension
in chamber at 40m, will report here
  
  16   Tue Jun 22 22:28:09 2021 KojiGeneralDesign specsTest Mass wedge designThe
ETM wedge of 0.5deg will allow us to separate
the AR reflections. We will be OK with the
 wedge.pdfLayout.pdfETM.pdfITM.pdf 
  15   Fri Jun 4 11:09:27 2021 PacoGeneralDesign specsHR coating tolerance analysisThe HR coating specifications are:


ETM
  
  14   Fri May 7 17:50:31 2021 Nina Vaidya & Shruti MaliakalGeneralDesign specsArm Cavity Design 2021 updateHere are the final slides with all the
results on the Arm Cavity Design, please
review. 
 Arm_Cavity_Design_05072021_with_tolerances.pptxHOMhelper.pyArm_HOManalysis.ipynbHOMplot.py 
  13   Fri May 7 09:57:18 2021 StephenGeneralEquipmentOverall Dimensions for Mariner Suspension Test Chamber ConceptKoji, Stephen

Putting together Koji's design
work with Stephen's CAD, we consider
 mariner_suspension_test_chamber_concept.jpg 
  12   Tue Apr 27 12:28:43 2021 Nina Vaidya & Shruti MaliakalGeneralDesign specsArm Cavity Design 2021Rana’s code: R_c = 57.3

-->New code with optimization:
sweeping through a range of R_c, using a
 Arm_Cavity_Design_04232021.pptxArm_HOM_optimization.ipynb 
  11   Fri Apr 23 10:41:22 2021 AidanGeneralDesign specs2 um photodiode requirementsMCT HgCdTe requirements: https://docs.google.com/spreadsheets/d/1lajp17yusbkacHEMSobChKepiqKYesHWIJ6L7fgr-yY/edit?usp=sharing

 
  
  10   Fri Apr 2 19:59:53 2021 PacoGeneralDesign specsDifferential evolution strategiesDifferential evolution strategies 'benchmarking'
for thin film optimization

Since
I have been running the ETM/ITM coatings
 diffevostrategies.pdf 
  9   Wed Mar 24 17:42:50 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IYeah, the magnitudes are the inverse weighted
scalar costs (so they lie on the appropriate
relative scale) and indeed larger enclosed
  
  8   Wed Mar 24 17:36:46 2021 PacoGeneralDesign specsLeast common multiple stacks and varL costUpdate on ETM/ITM coating design;

-
Following what seemed like a good, intuitive
suggestion from Anchal, I implemented a parameter
 ETM_Layers_210323_0925.pdf 
  7   Wed Mar 17 21:24:27 2021 gautamGeneralDesign specsSilicon TM dichroic coatings for phase II guess you have tried it already - but
does enforcing the stacks to be repeating
bilayer pairs of the same thickness fail
  
  6   Wed Mar 17 19:51:42 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IUpdate on ETM

New optima are
being found using the same basic code with
some modifications, which I summarize below;
 ETM_R_210317_1927.pdfETM_Layers_210317_1927.pdfETM_nominal_cornerPlt.pdf 
  5   Fri Mar 5 11:05:13 2021 StephenGeneralDesign specsFeasibility of 6" optic size in CAD6" vs 4" optic size comparison
using CAD - worth hopping into the 3D geometry
using the link below, but also posting a
 4in_from_20210305_easm.png6in_from_20210305_easm.png 
  4   Thu Mar 4 17:04:52 2021 PacoGeneralDesign specsSilicon TM dichroic coatings for phase IHave been using the 40m
Coatings repo code by Gautam (with some
modifications to make dichroic designs under
 ETM_coating_candidates.pdfITM_coating_candidates.pdf 
  3   Fri Jun 5 11:13:50 2020 RaymondGeneralHeat LoadSteady state heat load exampleAttached is a cartoon partial view into
the heat load experienced by the Mariner
assembly.
 Heat_Load_Sketch.pdf 
  2   Thu May 21 12:10:03 2020 StephenGeneralResourcesOngoing Mariner ResourcesOngoing points of updates/content (list
to be maintained and added)
Mariner
  
  1   Thu May 21 11:51:44 2020 KojiGeneralGeneralMariner Elog TestThe first entry of the Mariner elog post   
ELOG V3.1.3-