Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
Entry  Thu Oct 27 22:12:21 2022, rana, General, Optical Contacting, plotting and PID 
Entry  Tue Jul 5 21:06:47 2022, Juan, General, General, Work Update  IMG-5362.jpgIMG-5361.jpg
Entry  Thu Oct 20 22:43:05 2022, Jennifer Hritz, General, Optical Contacting, Wired the thermocouples backwards wrong_correct_polarization_PXL_20221022_054250498_20221022_055117337.MP.jpg
Entry  Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png
Entry  Thu Jul 7 10:23:04 2022, Juan, General, General, Update  IMG-5378.jpgIMG-5379.jpg
Entry  Fri Jul 22 13:47:47 2022, Juan, General, General, Update 
Entry  Fri Aug 6 04:34:43 2021, Koji, General, General, Theoretical Cooling Time Limit cooling_curves.pdf
Entry  Wed Oct 19 21:51:10 2022, Jennifer Hritz, General, Optical Contacting, The trials and tribulations of the thermocouples thermocouple_connector_test_ciruit_PXL_20221020_035719119.MP.jpgcorrect_assembly_PXL_20221020_042855181.MP.jpgresistance_through_broken_and_fixed_connector_PXL_20221020_035951538_20221020_041939698.MP.jpgbroken_and_fixed_thermocouple_PXL_20221020_042242792_20221020_042201775.MP.jpgthermocouples_and_thermometers_room_temp.zip
Entry  Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg
Entry  Mon Oct 17 23:17:25 2022, Jennifer Hritz, General, Optical Contacting, Testing PWM code with actual samples first_real_PWM_test_samples_before_PXL_20221018_071840794.MP.jpgfirst_real_PWM_test_set_up_PXL_20221018_071943406.MP.jpgfirst_real_PWM_test_in_action_PXL_20221018_072832135.mp4
Entry  Tue Jun 22 22:28:09 2021, Koji, General, Design specs, Test Mass wedge design wedge.pdfLayout.pdfETM.pdfITM.pdf
Entry  Thu Jun 16 14:04:30 2022, Juan, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 16 19:43:36 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 23 21:11:03 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
Entry  Fri Oct 1 12:01:24 2021, Paco, General, Design specs, TM Barrel coating emissivity stack_1.pdfstack_2.pdfstack_3.pdfinterpolated_n_k.pdf
    Reply  Fri Oct 1 13:24:40 2021, Aidan, General, Design specs, TM Barrel coating emissivity 
    Reply  Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity stack_1.pdfstack_2.pdfstack_3.pdf
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
Entry  Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example Heat_Load_Sketch.pdf
Entry  Thu Mar 4 17:04:52 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I ETM_coating_candidates.pdfITM_coating_candidates.pdf
    Reply  Wed Mar 17 19:51:42 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I ETM_R_210317_1927.pdfETM_Layers_210317_1927.pdfETM_nominal_cornerPlt.pdf
    Reply  Wed Mar 17 21:24:27 2021, gautam, General, Design specs, Silicon TM dichroic coatings for phase I 
    Reply  Wed Mar 24 17:42:50 2021, Paco, General, Design specs, Silicon TM dichroic coatings for phase I 
Entry  Tue Oct 18 19:33:38 2022, Jennifer Hritz, General, Optical Contacting, Setting up thermocouples first_real_PWM_test_samples_before_after_PXL_20221018_080838426.MP.jpgK_Type_connector_PXL_20221019_000708969.MP.jpgthermocouple_plates_PXL_20221019_003002817.MP.jpg
Entry  Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame no_sos_cad_screenshot.pngvault_check_in_of_mariner_suspension_cad.png
Entry  Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS OSEMs.xlsx
Entry  Thu Aug 4 11:26:55 2022, Juan, General, General, Sat Amp IMG-6153.jpg
Entry  Sun Oct 16 14:20:32 2022, Jennifer Hritz, General, Optical Contacting, Samples after 2 weeks under pressure 2_weeks_pressure_PXL_20221004_190652540_20221017_074745619.jpg
Entry  Thu Sep 9 11:25:30 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion etm_updated.pdfitm_updated.pdf
    Reply  Thu Sep 9 20:42:34 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion ETM210909190218.pdfITMLayers210909204021.pdf
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Sat Jul 2 09:22:39 2022, Juan , General, General, Progress update  IMG-5220.jpg
Entry  Sat Oct 22 21:18:56 2022, Jennifer Hritz, General, Optical Contacting, PWM v3.0 PWM_plates_-_increase_280°C_in_10_minutes.pdf
Entry  Fri Oct 21 22:22:37 2022, Jennifer Hritz, General, Optical Contacting, PWM v2.6 on new thermocouple set up PWM_plates_-_increase_180°C_in_10_minutes.pdf
Entry  Tue Oct 25 18:55:38 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 very slow heating 
Entry  Mon Oct 24 21:23:22 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 longer off times in cycle PWM_plates_-_1000_ms_on_9000_ms_off.pdf
Entry  Wed Oct 26 21:27:23 2022, Jennifer, General, Optical Contacting, PWM 3.1 (more) very slow heating 
Entry  Sun Oct 23 21:01:40 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.0 (+280°C in 5) PWM_plates_-_increase_280°C_in_5_minutes.pdf
Entry  Fri May 7 09:57:18 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept mariner_suspension_test_chamber_concept.jpg
    Reply  Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept 
Entry  Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources 
Entry  Tue Jul 26 14:17:44 2022, Juan, General, General, OSEMS actuators  8x
    Reply  Tue Aug 23 17:10:50 2022, Paco, General, Design specs, New corner plots ITM_corner.pdfETM_corner.pdf
Entry  Tue Oct 12 12:44:44 2021, Jiri Smetana, General, General, New Damping Loop Model 
Entry  Mon Oct 11 15:22:18 2021, Yehonathan, General, General, Microcomb alternatives ELMO_specs.pngHNLF_specs.pngSimulationResults1.pngSimulationResults3.png
Entry  Fri Sep 24 13:12:00 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps 
    Reply  Mon Sep 27 17:01:53 2021, rana, General, Heat Load, Mariner cooldown model status + next steps 
ELOG V3.1.3-