40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, Page 1 of 3  Not logged in ELOG logo
Entry  Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame no_sos_cad_screenshot.pngvault_check_in_of_mariner_suspension_cad.png
    Reply  Wed Nov 3 02:52:49 2021, Koji, General, Suspension, Mariner Sus Design 
    Reply  Thu Nov 4 00:42:05 2021, Koji, General, Suspension, Mariner Sus Design Screen_Shot_2021-11-04_at_12.38.46_AM.pngScreen_Shot_2021-11-04_at_12.39.53_AM.png
Entry  Thu May 5 19:56:25 2022, Koji, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 40m_Mariner_Suspension-0062.png40m_Mariner_Suspension.mp4
    Reply  Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps 
Entry  Thu Jun 16 14:04:30 2022, Juan, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 16 19:43:36 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
    Reply  Thu Jun 23 21:11:03 2022, Koji, General, Suspension, Table for Mariner Suspension Cryo 
Entry  Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources 
Entry  Thu Jul 7 15:20:04 2022, rana, General, Optical Contacting, some useful links 
Entry  Mon Jul 11 16:24:31 2022, Jennifer Hritz, General, Optical Contacting, Baselining the temperature output of the Oster hot plate PXL_20220708_230038748.jpgPXL_20220708_230234841.MP.jpg
Entry  Mon Jul 11 17:27:39 2022, Jennifer Hritz, General, Optical Contacting, First successful bond PXL_20220712_223449788.MP.jpg
Entry  Thu Jul 14 14:55:01 2022, Jennifer Hritz, General, Optical Contacting, Testing isopropanol and methanol PXL_20220714_220953206.MP_2.jpgPXL_20220714_220940258.MP_2.jpgPXL_20220714_222105409.jpgPXL_20220713_003923957.jpg
Entry  Wed Jul 27 14:50:20 2022, Jennifer Hritz, General, Optical Contacting, Bonding without liquids and narrowing down heating issue PXL_20220727_214658230.jpgPXL_20220727_214241668.mp4
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Wed Sep 28 22:11:31 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides thor_lab_slides_first_bond_PXL_20220929_045352675.MP.jpgthor_lab_slides_after_attempting_to_expand_bond_area_PXL_20220929_045510075.MP.jpg
Entry  Thu Sep 29 18:36:40 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides (continued) before_heat_PXL_20220930_011031420.MP.jpgset_up_PXL_20220930_011050114.MP.jpgright_after_heating_PXL_20220930_014301900.MP.jpgafter_4ish_hours_of_cooling_PXL_20220930_063533904.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Sat Oct 1 23:00:03 2022, Jennifer Hritz, General, Optical Contacting, (RESULTS!) Quick test heat and pressure test samples_before_AND_after_pressure_PXL_20221002_054158446.MP.jpgsamples_before_AND_after_heat_w_pressure_PXL_20221002_053842185.MP.jpg
Entry  Sun Oct 2 23:23:07 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure before_time_on_left_pressure_on_right_PXL_20221003_061828860.MP.jpgset_up_time_vs_pressure_PXL_20221003_062018249.MP.jpgin_progress_time_vs_pressure_PXL_20221003_062117715.MP.jpg
Entry  Mon Oct 3 23:32:30 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure (Update) pressure_v_time_samples_both.jpg
Entry  Tue Oct 4 22:15:23 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #1 PWM_Test_#1_(first_300_sec).pdfframe_from_pwm_test1_video_PXL_20221005_064240498_exported_231444.jpg
Entry  Wed Oct 5 23:24:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #2 PWM_Test_#2.pdfPWM_Test_#2_(comparison).pdf
Entry  Fri Oct 7 00:21:24 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #3 PWM_Test_#3.pdfPWM_Test_#3_(comparison).pdfhot_plate_cycler_v1.zipPWM_tests_1-3.zip
Entry  Fri Oct 7 21:20:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 progress PWM_Test_#2_(log_comparison).pdfPWM_Test_#3_(log_comparison).pdf
Entry  Sat Oct 8 23:22:25 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 PWM_v2_Test_#1.pdf
Entry  Sun Oct 9 21:55:53 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 & 2 PWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Mon Oct 10 15:34:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.1,2,3 Test #1 and v2.3 Test #2 PWM_v2.1_test1_max_rate_reached_and_peak_heat.jpg
Entry  Tue Oct 11 23:59:07 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #1 and 2 PWM_v2.3_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2.3_Test_#2_-_increase_180°C_in_7_minutes.pdfPWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Wed Oct 12 23:26:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #3 PWM_v2.3_Test_#3_-_increase_180°C_in_20_minutes.pdf
Entry  Thu Oct 13 20:56:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.4,5 Test #3 PWM_v2.3_Test_#3_-_increase_180°C_in_20_minutes.pdf
Entry  Fri Oct 14 21:36:52 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #3 PWM_v2_Test_#3_-_increase_180°C_in_20_minutes.pdfPWM_v2.6_Test_#3_-_increase_180°C_in_20_minutes.pdfcycler_v1_graphs.zipcycler_v2_graphs.ziphot_plate_cycler_v1-2.6.zip
Entry  Sat Oct 15 21:59:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #1, 2, 3 PWM_v2.6_Test_#1_2_3_-_increase_180°C_in_10_7_20_minutes.pdfPWM_v2.6_tests_data.zip
Entry  Sun Oct 16 14:20:32 2022, Jennifer Hritz, General, Optical Contacting, Samples after 2 weeks under pressure 2_weeks_pressure_PXL_20221004_190652540_20221017_074745619.jpg
Entry  Mon Oct 17 23:17:25 2022, Jennifer Hritz, General, Optical Contacting, Testing PWM code with actual samples first_real_PWM_test_samples_before_PXL_20221018_071840794.MP.jpgfirst_real_PWM_test_set_up_PXL_20221018_071943406.MP.jpgfirst_real_PWM_test_in_action_PXL_20221018_072832135.mp4
Entry  Tue Oct 18 19:33:38 2022, Jennifer Hritz, General, Optical Contacting, Setting up thermocouples first_real_PWM_test_samples_before_after_PXL_20221018_080838426.MP.jpgK_Type_connector_PXL_20221019_000708969.MP.jpgthermocouple_plates_PXL_20221019_003002817.MP.jpg
Entry  Wed Oct 19 21:51:10 2022, Jennifer Hritz, General, Optical Contacting, The trials and tribulations of the thermocouples thermocouple_connector_test_ciruit_PXL_20221020_035719119.MP.jpgcorrect_assembly_PXL_20221020_042855181.MP.jpgresistance_through_broken_and_fixed_connector_PXL_20221020_035951538_20221020_041939698.MP.jpgbroken_and_fixed_thermocouple_PXL_20221020_042242792_20221020_042201775.MP.jpgthermocouples_and_thermometers_room_temp.zip
Entry  Thu Oct 20 22:43:05 2022, Jennifer Hritz, General, Optical Contacting, Wired the thermocouples backwards wrong_correct_polarization_PXL_20221022_054250498_20221022_055117337.MP.jpg
Entry  Fri Oct 21 22:22:37 2022, Jennifer Hritz, General, Optical Contacting, PWM v2.6 on new thermocouple set up PWM_plates_-_increase_180°C_in_10_minutes.pdf
Entry  Sat Oct 22 21:18:56 2022, Jennifer Hritz, General, Optical Contacting, PWM v3.0 PWM_plates_-_increase_280°C_in_10_minutes.pdf
Entry  Sun Oct 23 21:01:40 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.0 (+280°C in 5) PWM_plates_-_increase_280°C_in_5_minutes.pdf
Entry  Mon Oct 24 21:23:22 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 longer off times in cycle PWM_plates_-_1000_ms_on_9000_ms_off.pdf
Entry  Tue Oct 25 18:55:38 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 very slow heating 
Entry  Wed Oct 26 21:27:23 2022, Jennifer, General, Optical Contacting, PWM 3.1 (more) very slow heating 
Entry  Thu Oct 27 22:12:21 2022, rana, General, Optical Contacting, plotting and PID 
Entry  Sat Jan 7 17:08:47 2023, Sophia Adams, General, Optical Contacting,  
Entry  Mon Jan 9 16:18:50 2023, Sophia Adams, General, Optical Contacting,  arduinoRoomTempReading.jpg
Entry  Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example Heat_Load_Sketch.pdf
ELOG V3.1.3-