31
|
Mon Sep 27 17:01:53 2021 |
rana | General | Heat Load | Mariner cooldown model status + next steps | How
about a diagram so that we can understand |
|
52
|
Tue May 10 18:29:11 2022 |
rana | General | Suspension | Mariner Suspension Cryo shield Install / Removal steps | |
|
60
|
Thu Jul 7 15:20:04 2022 |
rana | General | Optical Contacting | some useful links | For our optical contacting, Jennifer and
I are starting out with glass (microscope
slides), with the setup in the EE shop next |
|
114
|
Thu Oct 27 22:12:21 2022 |
rana | General | Optical Contacting | plotting and PID | The Arduino / AC PWM interface looks good.
I recommend that you maintain the code in
GitHub and post a link to the repo whenever |
|
7
|
Wed Mar 17 21:24:27 2021 |
gautam | General | Design specs | Silicon TM dichroic coatings for phase I | I guess you have tried it already - but
does enforcing the stacks to be repeating
bilayer pairs of the same thickness fail |
|
38
|
Mon Oct 11 15:22:18 2021 |
Yehonathan | General | General | Microcomb alternatives | Following our discussion at the Friday
JC meeting, I gathered several resources
and made a small simulation to show how frequency |
   |
2
|
Thu May 21 12:10:03 2020 |
Stephen | General | Resources | Ongoing Mariner Resources | Ongoing points of updates/content (list
to be maintained and added)
Mariner |
|
5
|
Fri Mar 5 11:05:13 2021 |
Stephen | General | Design specs | Feasibility of 6" optic size in CAD | 6" vs 4" optic size comparison
using CAD - worth hopping into the 3D geometry
using the link below, but also posting a |
 |
13
|
Fri May 7 09:57:18 2021 |
Stephen | General | Equipment | Overall Dimensions for Mariner Suspension Test Chamber Concept | Koji, Stephen
Putting together Koji's design
work with Stephen's CAD, we consider |
|
17
|
Wed Jun 30 16:21:53 2021 |
Stephen | General | Design specs | | [Stephen, Koji]
WIP - check layout of 60 cm suspension
in chamber at 40m, will report here |
|
18
|
Wed Jul 7 16:32:27 2021 |
Stephen | General | Equipment | Overall Dimensions for Mariner Suspension Test Chamber Concept | WIP - Stephen to check on new suspension
dimensions and fit into 40m chamber |
|
23
|
Thu Aug 26 17:40:41 2021 |
Stephen | General | Suspension | Selecting MOS-style frame | [Koji, Stephen]
Kind of a silly post, and not very
scientific, but we are sticking to it. During |
 |
118
|
Sat Jan 7 17:08:47 2023 |
Sophia Adams | General | Optical Contacting | | I am getting started on building the arduino
circuit as well as setting up my computer
so I can communicate between jupyter notebook |
|
119
|
Mon Jan 9 16:18:50 2023 |
Sophia Adams | General | Optical Contacting | | |
|
3
|
Fri Jun 5 11:13:50 2020 |
Raymond | General | Heat Load | Steady state heat load example | Attached is a cartoon partial view into
the heat load experienced by the Mariner
assembly. |
|
30
|
Fri Sep 24 13:12:00 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | *Note: the current modeling script can
be found at: CryoEngineering/MarinerCooldownEstimation.ipynb
Nina pointed me to the current |
|
32
|
Wed Sep 29 16:15:19 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | Attachment 1 is a geometric diagram that
reflects the current state of the ITM cooldown
model, introduced in [30]. |
   |
37
|
Tue Oct 5 17:46:14 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | Building on [32],
I added a copper cold finger to conductively
cool the inner shield, instead of holding |
  |
42
|
Fri Oct 15 13:45:55 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | I used the same model in [37]
to consider how test mass length affects
the cooldown. Attachment 1 plots the curves |
|
43
|
Fri Oct 15 14:31:15 2021 |
Radhika | General | Heat Load | Mariner cooldown model status + next steps | I reran the cooldown model, setting the
emissivity of the inner surface of the inner
shield to 0.7 (coating), and the emissivity |
 |
79
|
Fri Aug 26 14:24:57 2022 |
Radhika | General | Heat Load | Mariner TM Cooldown model | Here I describe the current radiative cooldown
model for a Mariner test mass, using parameters
from the most recent CAD model. A diagram |
6x |
80
|
Mon Aug 29 15:44:46 2022 |
Radhika | General | Heat Load | Mariner TM Cooldown model | Here is a more detailed analysis of varying
the length and radius of the snout.
Attachment 1 plots the heat load |
 |
81
|
Wed Sep 7 10:42:12 2022 |
Radhika | General | Heat Load | Mariner TM Cooldown model | The attached plot (upper) compares the
heat load delivered to the test mass from
various snout lengths (end to end), as a |
|
4
|
Thu Mar 4 17:04:52 2021 |
Paco | General | Design specs | Silicon TM dichroic coatings for phase I | Have been using the 40m
Coatings repo code by Gautam (with some
modifications to make dichroic designs under |
 |
6
|
Wed Mar 17 19:51:42 2021 |
Paco | General | Design specs | Silicon TM dichroic coatings for phase I | Update on ETM
New optima are
being found using the same basic code with
some modifications, which I summarize below; |
  |
8
|
Wed Mar 24 17:36:46 2021 |
Paco | General | Design specs | Least common multiple stacks and varL cost | Update on ETM/ITM coating design;
-
Following what seemed like a good, intuitive
suggestion from Anchal, I implemented a parameter |
|
9
|
Wed Mar 24 17:42:50 2021 |
Paco | General | Design specs | Silicon TM dichroic coatings for phase I | Yeah, the magnitudes are the inverse weighted
scalar costs (so they lie on the appropriate
relative scale) and indeed larger enclosed |
|
10
|
Fri Apr 2 19:59:53 2021 |
Paco | General | Design specs | Differential evolution strategies | Differential evolution strategies 'benchmarking'
for thin film optimization
Since
I have been running the ETM/ITM coatings |
|
15
|
Fri Jun 4 11:09:27 2021 |
Paco | General | Design specs | HR coating tolerance analysis | The HR coating specifications are:
ETM |
|
19
|
Tue Jul 27 11:38:25 2021 |
Paco | General | Design specs | DOPO single pass PDC efficiency | Here is a set of curves describing the
single-pass downconversion efficiency in
the 20 mm long PPKTP crystals for the DOPO. |
|
24
|
Thu Sep 9 11:25:30 2021 |
Paco | General | Design specs | Rerun HR coatings with n,k dispersion | [Paco]
I've re-run the HR coating
designs for both ETM and ITM using interpolated |
 |
25
|
Thu Sep 9 20:42:34 2021 |
Paco | General | Design specs | Rerun HR coatings with n,k dispersion | [Paco]
Alright, I've done a re-optimization
targetting a wider T band around 2128 nm. |
 |
28
|
Sun Sep 19 18:52:58 2021 |
Paco | General | Design specs | HR coating emissivity | [Paco, Nina]
We have been working on an estimate
of the wavelength dependent emissivity for |
 |
33
|
Fri Oct 1 11:52:06 2021 |
Paco | General | Design specs | HR coating emissivity | [Paco, Nina, Aidan]
Updated the stack emissivity code
to use the Kitamura paper fused silica dispersion |
 |
34
|
Fri Oct 1 12:01:24 2021 |
Paco | General | Design specs | TM Barrel coating emissivity | [Paco, Nina, Aidan]
We ran our stack emissivity calculation
on different AR stacks to try and make a |
   |
36
|
Fri Oct 1 14:11:23 2021 |
Paco | General | Design specs | TM Barrel coating emissivity | Agree with this.
Quickly running tmm on the same "stacks"
gave the Attachment #1-3. (Ignore the |
  |
47
|
Fri Nov 5 11:51:50 2021 |
Paco | General | Design specs | Estimate of in-air absorption near 2.05 um | [Paco]
I used the HITRAN database to download
the set of ro-vibrational absorption lines |
  |
48
|
Tue Nov 16 11:47:54 2021 |
Paco | General | Design specs | Estimate of in-air absorption near 2.05 um | [Paco]
There was an error in the last
plot of the previous log. This was correctly |
|
67
|
Mon Jul 18 18:34:29 2022 |
Paco | General | Design specs | HR coating update | I've been running the HR coating optimization
for mariner TMs. Relative to the specifications
found here |
   |
68
|
Fri Jul 22 13:36:55 2022 |
Paco | General | Design specs | HR coating update | Here are some corner plots to analyze the
sensitivity of the designs in the previous
elog to a 1% gaussian |
 |
76
|
Tue Aug 16 09:58:23 2022 |
Paco | General | Design specs | HR coating update | A couple of coating stacks with better
tolerance (transmission +- 10%). Attachments
#1-2 show the spectral reflectivities |
6x |
78
|
Tue Aug 23 17:10:50 2022 |
Paco | General | Design specs | New corner plots | Instead of varying individual layer thicknesses
using the MC sampler, I made sure both the
thickness and index of refractions are varied |
 |
12
|
Tue Apr 27 12:28:43 2021 |
Nina Vaidya & Shruti Maliakal | General | Design specs | Arm Cavity Design 2021 | Rana’s code: R_c = 57.3
-->New code with optimization:
sweeping through a range of R_c, using a |
 |
14
|
Fri May 7 17:50:31 2021 |
Nina Vaidya & Shruti Maliakal | General | Design specs | Arm Cavity Design 2021 update | Here are the final slides with all the
results on the Arm Cavity Design, please
review. |
   |
1
|
Thu May 21 11:51:44 2020 |
Koji | General | General | Mariner Elog Test | The first entry of the Mariner elog post |
|
16
|
Tue Jun 22 22:28:09 2021 |
Koji | General | Design specs | Test Mass wedge design | The
ETM wedge of 0.5deg will allow us to separate
the AR reflections. We will be OK with the |
   |
20
|
Fri Aug 6 04:34:43 2021 |
Koji | General | General | Theoretical Cooling Time Limit | I was thinking about how fast we can cool
the test mass. No matter how we improve the
emissivity of the test mass and the cryostat, |
|
21
|
Tue Aug 17 17:48:57 2021 |
Koji | General | Equipment | Crackle SW model | As a kickoff of the mariner sus cryostat
design, I made a tentative crackle chamber
model in SW. |
|
29
|
Fri Sep 24 11:02:41 2021 |
Koji | General | General | Actuation Feedback Model and Noise | We had a meeting with the code open in
ZOOM. Here are some points we discussed:
The code requires another |
|
45
|
Wed Nov 3 02:52:49 2021 |
Koji | General | Suspension | Mariner Sus Design | All parameters are temporary:
Test mass size: D150mm x L140mm