40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
Mariner elog, Page 1 of 1 |
Not logged in |
 |
|
New entries since: | Wed Dec 31 16:00:00 1969 | |
+
Tue May 10 18:29:11 2022, rana, General, Suspension, Mariner Suspension Cryo shield Install / Removal steps
| +
Wed Dec 15 06:43:43 2021, Jiri Smetana, General, General, Lagrangian Model - Translation & Pitch
| +
Tue Nov 16 11:47:54 2021, Paco, General, Design specs, Estimate of in-air absorption near 2.05 um
| +
Thu Nov 4 00:42:05 2021, Koji, General, Suspension, Mariner Sus Design 
|
Tue Oct 26 08:09:08 2021, Jiri Smetana, General, General, Lagrangian Suspension Model - Extended Body 
| +
Fri Oct 15 14:31:15 2021, Radhika, General, Heat Load, Mariner cooldown model status + next steps 
| +
Thu Oct 14 04:17:36 2021, Jiri Smetana, General, General, Damping Loop (Point-Mass Pendulums) 8x
|
Tue Oct 12 12:44:44 2021, Jiri Smetana, General, General, New Damping Loop Model
|
Mon Oct 11 15:22:18 2021, Yehonathan, General, General, Microcomb alternatives   
| +
Fri Oct 1 14:11:23 2021, Paco, General, Design specs, TM Barrel coating emissivity  
| +
Fri Oct 1 11:52:06 2021, Paco, General, Design specs, HR coating emissivity 
| +
Fri Sep 24 11:02:41 2021, Koji, General, General, Actuation Feedback Model and Noise
| +
Thu Sep 9 20:42:34 2021, Paco, General, Design specs, Rerun HR coatings with n,k dispersion 
|
Thu Aug 26 17:40:41 2021, Stephen, General, Suspension, Selecting MOS-style frame 
|
Tue Aug 24 08:15:37 2021, Jiri Smetana, General, General, Actuation Feedback Model  
|
Tue Aug 17 17:48:57 2021, Koji, General, Equipment, Crackle SW model
|
Fri Aug 6 04:34:43 2021, Koji, General, General, Theoretical Cooling Time Limit
|
Tue Jul 27 11:38:25 2021, Paco, General, Design specs, DOPO single pass PDC efficiency
| +
Wed Jul 7 16:32:27 2021, Stephen, General, Equipment, Overall Dimensions for Mariner Suspension Test Chamber Concept
|
Wed Jun 30 16:21:53 2021, Stephen, General, Design specs,
|
Tue Jun 22 22:28:09 2021, Koji, General, Design specs, Test Mass wedge design   
| +
Fri Jun 4 11:09:27 2021, Paco, General, Design specs, HR coating tolerance analysis
|
Fri May 7 17:50:31 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 update   
|
Tue Apr 27 12:28:43 2021, Nina Vaidya & Shruti Maliakal, General, Design specs, Arm Cavity Design 2021 
|
Fri Apr 23 10:41:22 2021, Aidan, General, Design specs, 2 um photodiode requirements
|
Fri Mar 5 11:05:13 2021, Stephen, General, Design specs, Feasibility of 6" optic size in CAD 
|
Fri Jun 5 11:13:50 2020, Raymond, General, Heat Load, Steady state heat load example
|
Thu May 21 12:10:03 2020, Stephen, General, Resources, Ongoing Mariner Resources
|
Thu May 21 11:51:44 2020, Koji, General, General, Mariner Elog Test
|
|