40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
Mariner elog, Page 2 of 2
Not logged in
List
|
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
General
74 Entries
Goto page
Previous
1
, 2
All
ID
Date
Author
Type
Category
Subject
Text
51
Thu May 5 19:56:25 2022
Koji
General
Suspension
Mariner Suspension Cryo shield Install / Removal steps
Does this work? Is this insane?
52
Tue May 10 18:29:11 2022
rana
General
Suspension
Mariner Suspension Cryo shield Install / Removal steps
53
Thu Jun 16 14:04:30 2022
Juan
General
Suspension
Table for Mariner Suspension Cryo
Today we looked at possible locations for
where we will be setting up Mariner Suspension
and Cryo chamber. The first option was the
54
Thu Jun 16 19:43:36 2022
Koji
General
Suspension
Table for Mariner Suspension Cryo
- B246/QIL Skyhook
Find the base of Skyhook.
It should be in the storage room (B246).
55
Thu Jun 23 21:11:03 2022
Koji
General
Suspension
Table for Mariner Suspension Cryo
Table moving effort in the OMC lab: See
https://nodus.ligo.caltech.edu:8081/OMC_Lab/412
56
Mon Jun 27 08:22:22 2022
Juan
General
General
General Update/ Need to do task
I've managed to cut and crimp wires
for the power board for coil driver. I will
begin adding components to the coil driver
57
Sat Jul 2 09:22:39 2022
Juan
General
General
Progress update
I've completed one coil driver board.
Hopefully next week I can finish the
other 2 boards and make the modifications
58
Tue Jul 5 21:06:47 2022
Juan
General
General
Work Update
Update of my current work I have finished
one coil driver board and started on the
last two that I need here is the progress
59
Thu Jul 7 10:23:04 2022
Juan
General
General
Update
Almost done with coil driver boards
60
Thu Jul 7 15:20:04 2022
rana
General
Optical Contacting
some useful links
For our optical contacting, Jennifer and
I are starting out with glass (microscope
slides), with the setup in the EE shop next
61
Fri Jul 8 17:09:10 2022
Juan
General
General
Coil Driver and Sat Amp
All three coil driver boards are complete
and have been tested. Modification for all
4 sat amp have been completed. Ideally, I
62
Mon Jul 11 16:24:31 2022
Jennifer Hritz
General
Optical Contacting
Baselining the temperature output of the Oster hot plate
This was performed last Friday (7/8).
I secured a thermocouple perpendicular
against the hotplate and recorded the
63
Mon Jul 11 17:27:39 2022
Jennifer Hritz
General
Optical Contacting
First successful bond
Note that the slides have "GLOBE"
printed on one side. I always bond the opposite
using the opposite side without the text.
64
Mon Jul 11 17:39:17 2022
Juan
General
General
Coil driver chassis
Finished all 3 Coil Drover chassis
and power lines still need to install the
rear cables will do that after I finish Sat
65
Wed Jul 13 13:16:33 2022
Juan
General
General
Finished coil driver and sat amp
I have finished all coil driver and sat
amp chassis they all seem to be functioning
properly.
66
Thu Jul 14 14:55:01 2022
Jennifer Hritz
General
Optical Contacting
Testing isopropanol and methanol
Note that I am just testing out different
techniques, so I have not set up the thermocouples
to precisely measure the temperatue.
67
Mon Jul 18 18:34:29 2022
Paco
General
Design specs
HR coating update
I've been running the HR coating optimization
for mariner TMs. Relative to the specifications
found here
68
Fri Jul 22 13:36:55 2022
Paco
General
Design specs
HR coating update
Here are some corner plots to analyze the
sensitivity of the designs in the previous
elog to a 1% gaussian
69
Fri Jul 22 13:47:47 2022
Juan
General
General
Update
Just a general update of what I have been
up to deriving Lagrange for double pendulum
system and also been looking at code that
70
Tue Jul 26 14:17:44 2022
Juan
General
General
OSEMS actuators
we have 23 OSEMS they look all full built
and I will try and test them this week and
or next week.
8x
71
Wed Jul 27 14:50:20 2022
Jennifer Hritz
General
Optical Contacting
Bonding without liquids and narrowing down heating issue
I have found that, after cleaning the glass
with methanol (or even sometimes with just a dry
lense-cleaning cloth), I can get glass slides to
72
Thu Aug 4 11:26:55 2022
Juan
General
General
Sat Amp
Sat amp seems to be working just fine.
There does seem to be a saturation issue
with one of the outputs we may need to change
73
Thu Aug 4 13:44:56 2022
Jennifer Hritz
General
Optical Contacting
Success with slowly heating
Yesterday, I did two rounds of slowly heating
4 samples to the maximum hot plate temperature.
This was to formally test if my success
74
Mon Aug 8 13:00:56 2022
Juan
General
General
Sat Amp testing of OSEMS
In the following test, a single Sat Amp
chassis that holds Sat Amp Board S1106078
and S1106077
Goto page
Previous
1
, 2
All
ELOG V3.1.3-