40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog, Page 1 of 2  Not logged in ELOG logo
Entry  Fri Aug 25 13:25:05 2023, Radhika, General, General, Summary of JPL/Ball cryocooler discussion 
Entry  Wed Aug 23 16:34:47 2023, Sophia Adams, General, Optical Contacting, Matlab Cantilever Geometry Optimization optimizingParameters.mRectangularCantilever.mph
Entry  Wed Aug 23 11:13:58 2023, Sophia Adams, General, Optical Contacting, Matlab fminsearch Cantilever Geometry Optimization fminsearch_fvalplot.figfminsearch_graph.pdf
Entry  Tue Aug 22 10:16:54 2023, Sophia Adams, General, Optical Contacting, Matlab fminsearch Cantilever Geometry Optimization getEnergy.mgetRatio.mfminSearch.m
    Reply  Tue Aug 22 12:12:05 2023, Sophia Adams, General, Optical Contacting, Matlab fminsearch Cantilever Geometry Optimization 
       Reply  Tue Aug 22 13:14:22 2023, Sophia Adams, General, Optical Contacting, Matlab fminsearch Cantilever Geometry Optimization 
Entry  Fri Aug 26 14:24:57 2022, Radhika, General, Heat Load, Mariner TM Cooldown model 6x
    Reply  Mon Aug 29 15:44:46 2022, Radhika, General, Heat Load, Mariner TM Cooldown model VaryingSnoutparams.pdfMarinerTMCooldown_snout_optimal.pdf
       Reply  Wed Sep 7 10:42:12 2022, Radhika, General, Heat Load, Mariner TM Cooldown model SnoutLengthCooldownTM.pdf
          Reply  Wed Apr 12 12:03:34 2023, Radhika, General, Heat Load, Mariner TM Cooldown model MarinerTMCooldown_LN2_OS.pdfTMPowerBudget.pdfmariner_block_diagram_joints.pdf
             Reply  Fri Jun 2 11:31:29 2023, Radhika, General, Heat Load, Mariner TM Cooldown model MarinerITMCooldown_2023-05-31_ref.pdfMarinerTMPowerBudget.pdfMarinerTotalCoolingPower.pdfMariner_ITM_SUS_blockdiagram4.pdf
                Reply  Fri Jun 23 15:37:39 2023, Radhika, General, Heat Load, Mariner TM Cooldown model MarinerCooldown_withLN2.pdfMarinerITMCooldown_halfCstrapL.pdf
                   Reply  Fri Aug 4 17:07:41 2023, Radhika, General, Heat Load, Mariner TM Cooldown model VoyagerITMCooldown_with_LN2.pdfVoyagerITMCooldown_2023-05-31_ref.pdf
Entry  Mon Jun 26 13:53:40 2023, Sophia Adams, General, Optical Contacting, cantilever geometry to find the quality factor of a silicon bond Picture1.jpg
Entry  Fri Mar 24 20:27:46 2023, Jennifer Hritz, General, Optical Contacting, Controlling hot plate and recording temperature with one Arduino one_arduino_to_rule_them_all.png
Entry  Mon Feb 6 15:36:39 2023, Jennifer Hritz, General, Optical Contacting, Papers on making Q measurements of bonds 
Entry  Thu Feb 2 17:28:37 2023, Sophia Adams, General, Optical Contacting, Test of Temperature Reading of One Plate bokeh_plot.pngIMG_3135.jpg
Entry  Mon Jan 9 21:03:53 2023, Koji, General, General, Heavy item transport - preparation DOPO.jpgCAML.jpgQIL.jpg
    Reply  Tue Jan 10 23:30:25 2023, Koji, General, General, Heavy item transport - preparation PXL_20230110_214532535.jpgPXL_20230110_221731553.jpgPXL_20230110_222947057.MP.jpg
       Reply  Thu Jan 12 11:38:26 2023, Koji, General, General, How to move the large engine hoist through the narrow door PXL_20230110_223009017.jpgPXL_20230110_223015483.MP.jpgPXL_20230110_223026446.MP.jpgPXL_20230110_223035480.MP.jpg
          Reply  Thu Jan 12 11:54:08 2023, Koji, General, General, Heavy item transport 7x
             Reply  Thu Jan 12 15:36:22 2023, Koji, General, General, Crane configuration for the suspension test chamber crane_config.pdf
Entry  Mon Jan 9 16:18:50 2023, Sophia Adams, General, Optical Contacting,  arduinoRoomTempReading.jpg
Entry  Sat Jan 7 17:08:47 2023, Sophia Adams, General, Optical Contacting,  
Entry  Sat Jan 7 16:07:13 2023, , General, General,  
Entry  Thu Oct 27 22:12:21 2022, rana, General, Optical Contacting, plotting and PID 
Entry  Thu Oct 27 19:54:20 2022, Jennifer Hritz, , ,  
Entry  Wed Oct 26 21:27:23 2022, Jennifer, General, Optical Contacting, PWM 3.1 (more) very slow heating 
Entry  Tue Oct 25 18:55:38 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 very slow heating 
Entry  Mon Oct 24 21:23:22 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.1 longer off times in cycle PWM_plates_-_1000_ms_on_9000_ms_off.pdf
Entry  Sun Oct 23 21:01:40 2022, Jennifer Hritz, General, Optical Contacting, PWM 3.0 (+280C in 5) PWM_plates_-_increase_280°C_in_5_minutes.pdf
Entry  Sat Oct 22 21:18:56 2022, Jennifer Hritz, General, Optical Contacting, PWM v3.0 PWM_plates_-_increase_280C_in_10_minutes.pdf
Entry  Fri Oct 21 22:22:37 2022, Jennifer Hritz, General, Optical Contacting, PWM v2.6 on new thermocouple set up PWM_plates_-_increase_180C_in_10_minutes.pdf
Entry  Thu Oct 20 22:43:05 2022, Jennifer Hritz, General, Optical Contacting, Wired the thermocouples backwards wrong_correct_polarization_PXL_20221022_054250498_20221022_055117337.MP.jpg
Entry  Wed Oct 19 21:51:10 2022, Jennifer Hritz, General, Optical Contacting, The trials and tribulations of the thermocouples thermocouple_connector_test_ciruit_PXL_20221020_035719119.MP.jpgcorrect_assembly_PXL_20221020_042855181.MP.jpgresistance_through_broken_and_fixed_connector_PXL_20221020_035951538_20221020_041939698.MP.jpgbroken_and_fixed_thermocouple_PXL_20221020_042242792_20221020_042201775.MP.jpgthermocouples_and_thermometers_room_temp.zip
Entry  Tue Oct 18 19:33:38 2022, Jennifer Hritz, General, Optical Contacting, Setting up thermocouples first_real_PWM_test_samples_before_after_PXL_20221018_080838426.MP.jpgK_Type_connector_PXL_20221019_000708969.MP.jpgthermocouple_plates_PXL_20221019_003002817.MP.jpg
Entry  Mon Oct 17 23:17:25 2022, Jennifer Hritz, General, Optical Contacting, Testing PWM code with actual samples first_real_PWM_test_samples_before_PXL_20221018_071840794.MP.jpgfirst_real_PWM_test_set_up_PXL_20221018_071943406.MP.jpgfirst_real_PWM_test_in_action_PXL_20221018_072832135.mp4
Entry  Sun Oct 16 14:20:32 2022, Jennifer Hritz, General, Optical Contacting, Samples after 2 weeks under pressure 2_weeks_pressure_PXL_20221004_190652540_20221017_074745619.jpg
Entry  Sat Oct 15 21:59:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #1, 2, 3 PWM_v2.6_Test_#1_2_3_-_increase_180C_in_10_7_20_minutes.pdfPWM_v2.6_tests_data.zip
Entry  Fri Oct 14 21:36:52 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.6 Test #3 PWM_v2_Test_#3_-_increase_180°C_in_20_minutes.pdfPWM_v2.6_Test_#3_-_increase_180°C_in_20_minutes.pdfcycler_v1_graphs.zipcycler_v2_graphs.ziphot_plate_cycler_v1-2.6.zip
Entry  Thu Oct 13 20:56:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.4,5 Test #3 PWM_v2.3_Test_#3_-_increase_180C_in_20_minutes.pdf
Entry  Wed Oct 12 23:26:48 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #3 PWM_v2.3_Test_#3_-_increase_180°C_in_20_minutes.pdf
Entry  Tue Oct 11 23:59:07 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.3 Test #1 and 2 PWM_v2.3_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2.3_Test_#2_-_increase_180°C_in_7_minutes.pdfPWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Mon Oct 10 15:34:13 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2.1,2,3 Test #1 and v2.3 Test #2 PWM_v2.1_test1_max_rate_reached_and_peak_heat.jpg
Entry  Sun Oct 9 21:55:53 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 & 2 PWM_v2_Test_#1_-_increase_180°C_in_10_minutes.pdfPWM_v2_Test_#2_-_increase_180°C_in_7_minutes.pdf
Entry  Sat Oct 8 23:22:25 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 test #1 PWM_v2_Test_#1.pdf
Entry  Fri Oct 7 21:20:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM v2 progress PWM_Test_#2_(log_comparison).pdfPWM_Test_#3_(log_comparison).pdf
Entry  Fri Oct 7 00:21:24 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #3 PWM_Test_#3.pdfPWM_Test_#3_(comparison).pdfhot_plate_cycler_v1.zipPWM_tests_1-3.zip
Entry  Wed Oct 5 23:24:08 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #2 PWM_Test_#2.pdfPWM_Test_#2_(comparison).pdf
Entry  Tue Oct 4 22:15:23 2022, Jennifer Hritz, General, Optical Contacting, Hot plate PWM Test #1 PWM_Test_#1_(first_300_sec).pdfframe_from_pwm_test1_video_PXL_20221005_064240498_exported_231444.jpg
Entry  Mon Oct 3 23:32:30 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure (Update) pressure_v_time_samples_both.jpg
Entry  Sun Oct 2 23:23:07 2022, Jennifer Hritz, General, Optical Contacting, Cause of improved bond: time or pressure before_time_on_left_pressure_on_right_PXL_20221003_061828860.MP.jpgset_up_time_vs_pressure_PXL_20221003_062018249.MP.jpgin_progress_time_vs_pressure_PXL_20221003_062117715.MP.jpg
Entry  Sat Oct 1 23:00:03 2022, Jennifer Hritz, General, Optical Contacting, (RESULTS!) Quick test heat and pressure test samples_before_AND_after_pressure_PXL_20221002_054158446.MP.jpgsamples_before_AND_after_heat_w_pressure_PXL_20221002_053842185.MP.jpg
Entry  Fri Sep 30 21:51:31 2022, Jennifer Hritz, General, Optical Contacting, Quick test heat and pressure test pressure_set_up_PXL_20221001_040539385.MP.jpgsamples_before_pressure_PXL_20221001_040441662.MP.jpgheat_w_pressure_set_up_PXL_20221001_033228622.MP.jpgsamples_before_heat_w_pressure_PXL_20221001_034620991.MP.jpg
Entry  Thu Sep 29 18:36:40 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides (continued) before_heat_PXL_20220930_011031420.MP.jpgset_up_PXL_20220930_011050114.MP.jpgright_after_heating_PXL_20220930_014301900.MP.jpgafter_4ish_hours_of_cooling_PXL_20220930_063533904.jpg
Entry  Wed Sep 28 22:11:31 2022, Jennifer Hritz, General, Optical Contacting, Looked at Thor Lab slides thor_lab_slides_first_bond_PXL_20220929_045352675.MP.jpgthor_lab_slides_after_attempting_to_expand_bond_area_PXL_20220929_045510075.MP.jpg
Entry  Tue Sep 27 22:29:34 2022, Jennifer Hritz, General, Optical Contacting, Razor test apparatus disassembly pictures razor_before_PXL_20220817_211123631.MP.jpgrazor_after_PXL_20220911_062818511.MP.jpg
Entry  Mon Jul 18 18:34:29 2022, Paco, General, Design specs, HR coating update ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf
    Reply  Fri Jul 22 13:36:55 2022, Paco, General, Design specs, HR coating update ETM_corner.pdfITM_corner.pdf
       Reply  Tue Aug 16 09:58:23 2022, Paco, General, Design specs, HR coating update 6x
          Reply  Tue Aug 23 17:10:50 2022, Paco, General, Design specs, New corner plots ITM_corner.pdfETM_corner.pdf
Entry  Tue Aug 16 19:54:29 2022, Jennifer Hritz, General, Optical Contacting, Razor blade test PXL_20220817_023737796.MP.jpgPXL_20220817_023741865.MP.jpg
Entry  Mon Aug 15 16:37:51 2022, Juan , General, General, Update on Sat Amp and OSEMs IMG-6458.jpgIMG-6355.jpgIMG-6459.jpgIMG-6460.jpgOSEMdata.png
Entry  Mon Aug 8 13:00:56 2022, Juan, General, General, Sat Amp testing of OSEMS OSEMs.xlsx
Entry  Thu Aug 4 13:44:56 2022, Jennifer Hritz, General, Optical Contacting, Success with slowly heating PXL_20220803_232203193.jpgPXL_20220804_002433906.jpg
ELOG V3.1.3-