Entry  Mon Jul 18 18:34:29 2022, Paco, General, Design specs, HR coating update ETM_R.pdfITM_R.pdfETM_Layers.pdfITM_Layers.pdf
    Reply  Fri Jul 22 13:36:55 2022, Paco, General, Design specs, HR coating update ETM_corner.pdfITM_corner.pdf
       Reply  Tue Aug 16 09:58:23 2022, Paco, General, Design specs, HR coating update 6x
          Reply  Tue Aug 23 17:10:50 2022, Paco, General, Design specs, New corner plots ITM_corner.pdfETM_corner.pdf
Message ID: 78     Entry time: Tue Aug 23 17:10:50 2022     In reply to: 76
Author: Paco 
Type: General 
Category: Design specs 
Subject: New corner plots 

Instead of varying individual layer thicknesses using the MC sampler, I made sure both the thickness and index of refractions are varied as a global systematic error to estimate the design sensitivity. The results for ITM/ETM respectively, with 1e5 samples this time, are in Attachments 1-2 below.

Attachment 1: ITM_corner.pdf  824 kB  Uploaded Tue Aug 23 18:12:21 2022  | Hide | Hide all
ITM_corner.pdf
Attachment 2: ETM_corner.pdf  788 kB  Uploaded Tue Aug 23 18:12:35 2022  | Hide | Hide all
ETM_corner.pdf