40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Mariner elog  Not logged in ELOG logo
Message ID: 75     Entry time: Mon Aug 15 16:37:51 2022
Author: Juan  
Type: General 
Category: General 
Subject: Update on Sat Amp and OSEMs 

Sat Amp 

- Changes to sat amp 15.8 k ohm resistors instead of 16k The change has been made on Sat Amp - S1103733 & S1103732 ONLY Channel 4 and 2 have been changed on both boards.

OSEM

- I developed a test bed for our OSEM to measure force 

I will attach images of the setup and some of the results from 3 different OSEMs.

Future Work

- For the current test bed, we are using a clear plastic bin although not ideal it manages to get the job done and works for now there could be a better solution for this,
- Next step for OSEM we want to use 40 m single pendulum to test OSEM and measure the transfer function.

Attachment 1: IMG-6458.jpg  3.215 MB  Uploaded Mon Aug 15 18:16:06 2022  | Hide | Hide all
IMG-6458.jpg
Attachment 2: IMG-6355.jpg  3.750 MB  Uploaded Mon Aug 15 18:16:17 2022  | Hide | Hide all
IMG-6355.jpg
Attachment 3: IMG-6459.jpg  3.056 MB  Uploaded Mon Aug 15 18:18:15 2022  | Hide | Hide all
IMG-6459.jpg
Attachment 4: IMG-6460.jpg  2.628 MB  Uploaded Mon Aug 15 18:18:15 2022  | Hide | Hide all
IMG-6460.jpg
Attachment 5: OSEMdata.png  23 kB  Uploaded Mon Aug 15 18:20:22 2022  | Hide | Hide all
OSEMdata.png